We matched 78 patients with a loose cemented Charnley Elite Plus total hip replacement (THR) by age, gender, race, prosthesis and time from surgery with 49 patients with a well-fixed stable hip replacement, to determine if poor
Aims. The Exeter short stem was designed for patients with Dorr type A femora and short-term results are promising. The aim of this study was to evaluate the minimum five-year stem migration pattern of Exeter short stems in comparison with Exeter standard stems. Methods. In this case-control study, 25 patients (22 female) at mean age of 78 years (70 to 89) received cemented Exeter short stem (case group). Cases were selected based on Dorr type A femora and matched first by Dorr type A and then age to a control cohort of 21 patients (11 female) at mean age of 74 years (70 to 89) who received with cemented Exeter standard stems (control group). Preoperatively, all patients had primary hip osteoarthritis and no osteoporosis as confirmed by dual X-ray absorptiometry scanning. Patients were followed with radiostereometry for evaluation of stem migration (primary endpoint), evaluation of cement quality, and Oxford Hip Score. Measurements were taken preoperatively, and at three, 12, and 24 months and a minimum five-year follow-up. Results. At three months, subsidence of the short stem -0.87 mm (95% confidence interval (CI) -1.07 to -0.67) was lower compared to the standard stem -1.59 mm (95% CI -1.82 to -1.36; p < 0.001). Both stems continued a similar pattern of subsidence until five-year follow-up. At five-year follow-up, the short stem had subsided mean -1.67 mm (95% CI -1.98 to -1.36) compared to mean -2.67 mm (95% CI -3.03 to -2.32) for the standard stem (p < 0.001). Subsidence was not influenced by preoperative
The aim of the study was to investigate whether the primary stability of press-fit acetabular components can be improved by altering the impaction procedure. Three impaction procedures were used to implant acetabular components into human cadaveric acetabula using a powered impaction device. An impaction frequency of 1 Hz until complete component seating served as reference. Overimpaction was simulated by adding ten strokes after complete component seating. High-frequency implantation was performed at 6 Hz. The lever-out moment of the acetabular components was used as measure for primary stability. Permanent bone deformation was assessed by comparison of double micro-CT (µCT) measurements before and after impaction. Acetabular component deformation and impaction forces were recorded, and the extent of bone-implant contact was determined from 3D laser scans.Aims
Methods
The processes linking long-term bisphosphonate treatment to atypical fracture remain elusive. To establish a means of exploring this link, we have examined how long-term bisphosphonate treatment with prior ovariectomy modifies femur fracture behaviour and tibia mass and shape in murine bones. Three groups (seven per group) of 12-week-old mice were: 1) ovariectomized and 20 weeks thereafter treated weekly for 24 weeks with 100 μm/kg subcutaneous ibandronate (OVX+IBN); 2) ovariectomized (OVX); or 3) sham-operated (SHAM). Quantitative fracture analysis generated biomechanical properties for the femoral neck. Tibiae were microCT scanned and trabecular (proximal metaphysis) and cortical parameters along almost its whole length measured.Aims
Methods
Periprosthetic femoral fractures (PFFs) remain a major concern following cementless total hip arthroplasty (THA). This study aimed to evaluate the association between different types of cementless tapered stems and the risk of postoperative PFF. A retrospective review of primary THAs performed at a single center from January 2011 to December 2018 included 3,315 hips (2,326 patients). Cementless stems were classified according to their design geometry using the system proposed by Radaelli et al. The incidence of PFF was compared between flat taper porous-coated stems (type A), rectangular taper grit-blasted stems (type B1), and quadrangular taper hydroxyapatite-coated stems (type B2). Multivariate regression analyses were performed to identify independent factors related to PFF. The mean follow-up duration was 61 months (range, 12‒139 months). Overall, 45 (1.4%) postoperative PFFs occurred. The incidence of PFF was significantly higher in type B1 stems than in type A and type B2 stems (1.8 vs. 0.7 vs. 0.7%; P=0.022). Additionally, more surgical treatments (1.7 vs. 0.5 vs. 0.7%; P=0.013) and femoral revisions (1.2 vs. 0.2 vs. 0%; P=0.004) were required for PFF in type B1 stems. After controlling for confounding variables, older age (P<0.001), diagnosis of hip fracture (P<0.001), and use of type B1 stems (P=0.001) were significant factors associated with PFF. Type B1 rectangular taper stems were found to have higher risks for postoperative PFF and PFF requiring surgical management than type A and type B2 stems in THA. Femoral stem geometry should be considered when planning for cementless THA in elderly patients with compromised
Genetic skeletal disorders constitute a rare and heterogeneous bone diseases often leading to poor quality of life. Several surgical options are available. The surgeon must deal with specific features (bone deformity, previous procedures, abnormal
Post-operative peri-prosthetic femoral fracture (PO-PPFF) is one of the most relevant complications in primary Total Hip Arthroplasty (pTHA), accountable for a significant clinical and socio-economic burden both in revision and fixation settings. We retrospectively reviewed of our series of 1586 cementless total hip arthroplasty performed between 1999 and 2019 (achieving a minimum of 5-years follow-up) with different short stems. We have observed a cumulative low incidence of PO-PPFF of 0,33% (5 cases): we divided Po-PPFF in two groups: fracture occurred around a short stem (A) and around a standard shortened stem (B), according to French Hip & Knee Classification of Short Stems. Despite the length of observed period (mean follow-up 12 years, min 5 years max 24 years) a total of 1512 cases (mean age at surgery 61 years, max 74, min 40 years) were available to clinical and radiographic follow-up, being this population enrolled in elective surgery clinical protocols. Our data exceed the low incidence of post-operative femoral fracture around bone -preserving previously reported by Kim in 2018 (12 fracture out of 1089 cases:1.1%). No correlation have been observed among occurrence of PO-PPF age of the patient and no fracture occurred around cemented short stems despite patient's characteristics were unfavourable in term of age and
Studies have shown that 10–30% patients do not achieve optimal function outcomes after total hip replacement (THR). High quality randomised controlled trials (RCTs) evaluating the clinical and cost-effectiveness of techniques to improve functional outcomes after THR are lacking. We performed this study to evaluate the feasibility of a RCT comparing patient-reported functional outcomes after hybrid or fully cemented THR (ISRCTN11097021). Patients were recruited from two centres and randomised to receive either a fully cemented or hybrid THR. Data collection included Patient Reported Outcome Measures (PROMs), non-serious adverse events of special interest (AESI), serious adverse device effects (SADE) and NHS resource use. Qualitative interviews were undertaken to understand a) patient experiences of study processes and their reasons for taking part or not, and b) to understand surgeons’ perceptions of the study, factors affecting willingness to participate, and barriers to implementation of the future RCT findings. The target of 40 patients were successfully recruited for the feasibility RCT; the ratio of successful recruitment to eligible patients was 0.61 across both sites. Treatment crossovers occurred in four patients, all related to
Different techniques have been described to address massive bone loss of the acetabulum in revision hip surgery. aMace has gained popularity as it provides customization aiming to restore hip centre and provide good initial stability in cases of large non-contained defects. It takes into account quality of host bone. Its porous defect filling scaffold provides an excellent surface for osteointegration. Our aim was to assess the short and mid-term outcomes of patients who underwent revision surgery using aMace system. Ethical approval was obtained. A retrospective study included all patients who had aMace between June 2013 and October 2022 allowing for a minimum of 12-months follow-up. Patients’ demographics, indication, bone-loss severity, reconstruction details, re-operation, complications, mortality, pain and function were assessed. 52 cases were performed by 13 surgeons with median 51 months follow-up. Median age was 72.7 years. 86.5% were female. Average BMI was 25.3. Average ASA grade was 3. 65% were classified as Paprosky IIIB and 32% were IIIA. 73% were found to have poor
The incidence of hip fractures in the elderly is increasing. Minimally displaced and un-displaced hip fractures can be treated with either internal fixation or hemiarthroplasty. The aim was identifying the revision rate of internal fixation and hemiarthroplasty in patients 60 years or older with Garden I or II hip fractures and to identify risk factors associated with each method. A retrospective analysis was conducted from 2 Major Trauma Centres and 9 Trauma Units between 01/01/2015 and 31/12/2020. Patients managed conservatively, treated with a total hip replacement and missing data were excluded from the study. 1273 patients were included of which 26.2% (n=334) had cannulated hip fixation (CHF), 19.4% (n=247) had a dynamic hip screw (DHS) and 54.7% (n=692) had a hemiarthroplasty. 66 patients in total (5.2%) required revision surgery. The revision rates for CHF, DHS and hemiarthroplasty were 14.4%, 4%, 1.2% (p<0.001) respectively. Failed fixation was the most common reason for revision with the incidence increasing by 7-fold in the CHF group [45.8% (n=23) vs. 33.3% (n=3) in DHS; p<0.01]. The risk factors identified for CHF revision were age >80 (p<0.05), female gender (p<0.05) and smoking (p<0.05). The average length of hospital stay was decreased when using CHF compared to DHS and hemiarthroplasty (12.6 days vs 14.9 days vs 18.1 days respectively, p<0.001) and the 1 year mortality rate for CHF, DHS and hemiarthroplasty was 2.5%, 2% and 9% respectively. Fixation methods for Garden I and II hip fractures in elderly patients are associated with a higher revision rate than hemiarthroplasty. CHF has the highest revision rate at 14.4% followed by DHS and hemiarthroplasty. Female patients, patients over the age of 80 and patients with poor
Known risk factors for early periprosthetic femur fracture (PFF) following total hip arthroplasty (THA) include poor
Aims. The main aims were to identify risk factors predictive of a radiolucent line (RLL) around the acetabular component with an interface bioactive bone cement (IBBC) technique in the first year after THA, and evaluate whether these risk factors influence the development of RLLs at five and ten years after THA. Methods. A retrospective review was undertaken of 980 primary cemented THAs in 876 patients using cemented acetabular components with the IBBC technique. The outcome variable was any RLLs that could be observed around the acetabular component at the first year after THA. Univariate analyses with univariate logistic regression and multivariate analyses with exact logistic regression were performed to identify risk factors for any RLLs based on radiological classification of hip osteoarthritis. Results. RLLs were detected in 27.2% of patients one year postoperatively. In multivariate regression analysis controlling for confounders, atrophic osteoarthritis (odds ratio (OR) 2.17 (95% confidence interval (CI), 1.04 to 4.49); p = 0.038) and 26 mm (OR 3.23 (95% CI 1.85 to 5.66); p < 0.001) or 28 mm head diameter (OR 3.64 (95% CI 2.07 to 6.41); p < 0.001) had a significantly greater risk for any RLLs one year after surgery. Structural bone graft (OR 0.19 (95% CI 0.13 to 0.29) p < 0.001) and location of the hip centre within the true acetabular region (OR 0.15 (95% CI 0.09 to 0.24); p < 0.001) were significantly less prognostic. Improvement of the cement-bone interface including complete disappearance and poorly defined RLLs was identified in 15.1% of patients. Kaplan-Meier survival analysis for the acetabular component at ten years with revision of the acetabular component for aseptic loosening as the end point was 100.0% with a RLL and 99.1% without a RLL (95% CI 97.9 to 100). With revision of the acetabular component for any reason as the end point, the survival rate was 99.2% with a RLL (95% CI 97.6 to 100) and 96.5% without a RLL (95% CI 93.4 to 99.7). Conclusion. This study demonstrates that acetabular
First-time revision acetabular components have a 36% re-revision rate at 10 years in Australia, with subsequent revisions known to have even worse results. Acetabular component migration >1mm at two years following revision THA is a surrogate for long term loosening. This study aimed to measure the migration of porous tantalum components used at revision surgery and investigate the effect of achieving press-fit and/or three-point fixation within acetabular bone. Between May 2011 and March 2018, 55 patients (56 hips; 30 female, 25 male) underwent acetabular revision THR with a porous tantalum component, with a post-operative CT scan to assess implant to host bone contact achieved and Radiostereometric Analysis (RSA) examinations on day 2, 3 months, 1 and 2 years. A porous tantalum component was used because the defects treated (Paprosky IIa:IIb:IIc:IIIa:IIIb; 2:6:8:22:18; 13 with pelvic discontinuity) were either deemed too large or in a position preventing screw fixation of an implant with low coefficient of friction. Press-fit and three-point fixation of the implant was assessed intra-operatively and on postoperative imaging. Three-point acetabular fixation was achieved in 51 hips (92%), 34 (62%) of which were press-fit. The mean implant to host bone contact achieved was 36% (range 9–71%). The majority (52/56, 93%) of components demonstrated acceptable early stability. Four components migrated >1mm proximally at two years (1.1, 3.2, 3.6 and 16.4mm). Three of these were in hips with Paprosky IIIB defects, including 2 with pelvic discontinuity. Neither press-fit nor three-point fixation was achieved for these three components and the cup to host bone contact achieved was low (30, 32 and 59%). The majority of porous tantalum components had acceptable stability at two years following revision surgery despite treating large acetabular defects and poor
There is still little information on the histological characteristics of the acetabular bone tissue after failure of the primary prosthetic component. The purpose of this study is to characterize the viability and quality of the acetabular bone tissue in patients undergoing acetabular revision for aseptic loosening of uncemented components. 19 patients were enrolled: 14 hip revisions and 5 primary total hip arthroplasty. . Samples collecting. : three acetabular bone biopsy of patients were collected at the time of surgery with a 8G diameter needle after reaming. . Histological evaluation. : all samples, after removing the mineral component, were cut longitudinally with a thickness section of 5μm and colored with hematoxylin-eosin dichromic dye. Histological evaluation was done by optical microscopy with 40× magnification. Five
Background. The acknowledged benefit of the direct anterior (DA) approach is early functional return. Most surgeons in the U.S. use cementless femoral replacement given the negative track record of some cemented designs. However, delayed osseointegration of a femoral stem typically seen in older patients with poor
Objectives. Different criteria for assessing the reduction quality of trochanteric fractures have been reported. The Baumgaertner reduction quality criteria (BRQC) are relatively common and the Chang reduction quality criteria (CRQC) are relatively new. The objectives of the current study were to compare the reliability of the BRQC and CRQC in predicting mechanical complications and to investigate the clinical implications of the CRQC. Methods. A total of 168 patients were assessed in a retrospective observational study. Clinical information including age, sex, fracture side, American Society of Anesthesiologists (ASA) classification, tip-apex distance (TAD), fracture classification, reduction quality, blade position, BRQC, CRQC,
Osteoporosis can determine surgical strategy for total hip arthroplasty (THA), and perioperative fracture risk. The aims of this study were to use hip CT to measure femoral bone mineral density (BMD) using CT X-ray absorptiometry (CTXA), determine if systematic evaluation of preoperative femoral BMD with CTXA would improve identification of osteopenia and osteoporosis compared with available preoperative dual-energy X-ray absorptiometry (DXA) analysis, and determine if improved recognition of low BMD would affect the use of cemented stem fixation. Retrospective chart review of a single-surgeon database identified 78 patients with CTXA performed prior to robotic-assisted THA (raTHA) (Group 1). Group 1 was age- and sex-matched to 78 raTHAs that had a preoperative hip CT but did not have CTXA analysis (Group 2). Clinical demographics, femoral fixation method, CTXA, and DXA data were recorded. Demographic data were similar for both groups.Aims
Methods
Osteoporosis is common in total hip arthroplasty (THA) patients. It plays a substantial factor in the surgery’s outcome, and previous studies have revealed that pharmacological treatment for osteoporosis influences implant survival rate. The purpose of this study was to examine the prevalence of and treatment rates for osteoporosis prior to THA, and to explore differences in osteoporosis-related biomarkers between patients treated and untreated for osteoporosis. This single-centre retrospective study included 398 hip joints of patients who underwent THA. Using medical records, we examined preoperative bone mineral density measures of the hip and lumbar spine using dual energy X-ray absorptiometry (DXA) scans and the medications used to treat osteoporosis at the time of admission. We also assessed the following osteoporosis-related biomarkers: tartrate-resistant acid phosphatase 5b (TRACP-5b); total procollagen type 1 amino-terminal propeptide (total P1NP); intact parathyroid hormone; and homocysteine.Aims
Methods
The aim of this study was to assess the clinical and radiological results of patients who were revised using a custom-made triflange acetabular component (CTAC) for component loosening and pelvic discontinuity (PD) after previous total hip arthroplasty (THA). Data were extracted from a single centre prospective database of patients with PD who were treated with a CTAC. Patients were included if they had a follow-up of two years. The Hip Disability and Osteoarthritis Outcome Score (HOOS), modified Oxford Hip Score (mOHS), EurQol EuroQoL five-dimension three-level (EQ-5D-3L) utility, and Numeric Rating Scale (NRS), including visual analogue score (VAS) for pain, were gathered at baseline, and at one- and two-year follow-up. Reasons for revision, and radiological and clinical complications were registered. Trends over time are described and tested for significance and clinical relevance.Aims
Methods
Contemporary outcomes of primary total hip arthroplasties (THAs) with highly cross-linked polyethylene (HXLPE) liners in patients with inflammatory arthritis have not been well studied. This study examined the implant survivorship, complications, radiological results, and clinical outcomes of THA in patients with inflammatory arthritis. We identified 418 hips (350 patients) with a primary diagnosis of inflammatory arthritis who underwent primary THA with HXLPE liners from January 2000 to December 2017. Of these hips, 68% had rheumatoid arthritis (n = 286), 13% ankylosing spondylitis (n = 53), 7% juvenile rheumatoid arthritis (n = 29), 6% psoriatic arthritis (n = 24), 5% systemic lupus erythematosus (n = 23), and 1% scleroderma (n = 3). Mean age was 58 years (SD 14.8), 66.3% were female (n = 277), and mean BMI was 29 kg/m2 (SD 7). Uncemented femoral components were used in 77% of cases (n = 320). Uncemented acetabular components were used in all patients. Competing risk analysis was used accounting for death. Mean follow-up was 4.5 years (2 to 18).Aims
Methods