Advertisement for orthosearch.org.uk
Results 1 - 7 of 7
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 83 - 83
4 Apr 2023
Loukopoulou C Vorstius J Paxton J
Full Access

To ensure clinical relevance, the in vitro engineering of tissues for implantation requires artificial replacements to possess properties similar to native anatomy. Our overarching study is focussed on developing a bespoke bone-tendon in vitro model replicating the anatomy at the flexor digitorum profundus (FDP) tendon insertion site at the distal phalanx. Anatomical morphometric analysis has guided FDP tendon model design consisting of hard and soft tissue types. Here, we investigate potential materials for creation of the model's bone portion by comparison of two bone cements; brushite and genex (Biocomposites Ltd). 3D printed molds were prepared based on anatomical morphometric analysis of the FDP tendon insertion site and used to cast identical bone blocks from brushite and genex cements. Studies assessing the suitability of each cement type were conducted e.g. setting times, pH on submersion in culture medium and interaction with fibrin gels. Data was collected using qualitative imaging and qualitative measurements (N=3,n=6) for experimental conditions. Both brushite (BC) and genex (GC) cements could be cast into bespoke molds, producing individual blocks and were mixed/handled with appropriate setting times. On initial submersion in culture medium, BC caused a reduction in pH values (7.49 [control]) to 6.85) while GC remained stable (7.59). Reduction in pH value also affected fibrin gel interaction where gel was seen to be detaching/not forming around BC and medium discolouration was noted. This was not observed in GC. While GC outperformed BC in initial tests, repeated washing of BC led to pH stabilisation (7.5,3xwashes), consistent with their further use in this model. This study has compared BC and GC as materials for bone block production. Both materials show promise, and current work assessing material properties and cell proliferation are needed to inform our choice for use in our FDP-tendon-bone interface model. This research was supported by an ORUK Studentship award (ref:533). Genex was kindly provided by Biocomposites, Ltd


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 535 - 541
1 Apr 2008
Pendegrass CJ Sundar S Oddy MJ Cannon SR Briggs T Blunn GW

We used an in vivo model to assess the use of an autogenous cancellous bone block and marrow graft for augmenting tendon reattachment to metallic implants. We hypothesised that augmentation of the tendon-implant interface with a bone block would enable retention of the graft on the implant surface, enhance biological integration, and result in more consistent functional outcomes compared with previously reported morcellised graft augmentation techniques. A significant improvement in functional weight-bearing was observed between six and 12 weeks. The significant increase in ground reaction force through the operated limb between six and 12 weeks was greater than that reported previously with morcellised graft augmented reconstructions. Histological appearance and collagen fibre orientation with bone block augmentation more closely resembled that of an intact enthesis compared with the morcellised grafting technique. Bone block augmentation of tendon-implant interfaces results in more reliable functional and histological outcomes, with a return to pre-operative levels of weight-bearing by 24 weeks


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 117 - 117
1 Nov 2021
Longo UG
Full Access

The function of the upper extremity is highly dependent on correlated motion of the shoulder. The shoulder can be affected by several diseases. The most common are: rotator cuff tear (RCT), shoulder instability, shoulder osteoarthritis and fractures. Rotator cuff disease is a common disorder. It has a high prevalence rate, causing high direct and indirect costs. The appropriate treatment for RCT is debated. The American Academy Orthopaedic Surgeons guidelines state that surgical repair is an option for patients with chronic, symptomatic full-thickness RCT, but the quality of evidence is unconvincing. Thus, the AAOS recommendations are inconclusive. We are performing a randomized controlled trial to compare surgical and conservative treatment of RCT, in term of functional outcomes, rotator cuff integrity, muscle atrophy and fatty degeneration. Shoulder instability occurs when the head of the upper arm bone is forced out of the shoulder socket. Shoulder instabilities have been classified according to the etiology, the direction of instability, or on combinations thereof. The Thomas and Matsen classification, which is currently the most commonly utilized classification, divides shoulder instability events into the traumatic, unidirectional, Bankart lesion, and surgery (TUBS) and the atraumatic, multidirectional, bilateral, rehabilitation, and capsular shift (AMBRI) categories. The acquired instability overstress surgery (AIOS) category was then added. Surgical procedures for shoulder instability includes arthroscopic capsuloplasty, remplissage, bone block procedure or Latarjet procedure. Reverse total shoulder arthroplasty (RTSA) represents a good solution for the management of patients with osteoarthritis or fracture of the proximal humerus, with associated severe osteoporosis and RC dysfunction


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 17 - 17
1 Oct 2016
Leslie LJ Heaven G Swadener JG Junaid S Theivendran K Deshmukh SC
Full Access

Currently available fracture fixation devices that were originally developed for healthy bone are often not effective for patients with osteoporosis. Resulting outcomes are unsatisfactory, with longer recovery times, often requiring re-surgery for failed cases. One major issue is the design of bone screws, which can loosen or pull-out from osteoporotic bone. Design improvements are possible, but the development of new screws is a lengthy and expensive process due to the manufacture of the complex geometry involved. The aim of this research was to validate our currently available 3D printing technology in the design, manufacture and testing of screws. Three standard wood screw designs were reverse-engineered using computational modelling and then fabricated in polymeric resin using 3D rapid prototyping on a Stereolithography (SLA) machine. The original metal screws and the 3D screws (n=5 of each) were then inserted into a synthetic bone block (Sawbones, PCF5) representing the mechanical properties of severely osteoporotic cancellous bone. Pull-out tests were conducted in accordance with ASTM 543-13. The three metal screws exhibited pull-out strengths of 125, 74 and 118 N respectively. The 3D printed screws by comparison showed pull-out strengths approximately 15–20 % lower than their metal counterparts. However, when the results were normalised to the material tested, showing the relative changes to the first design, the pattern of results in the metal and 3D printed groups were almost identical (within 3 % of each other), showing excellent correlation. This study is the first to show that 3D Rapid Prototyping can be used in the pre-clinical testing of orthopaedic screws. The methodology provides a cheaper, faster development process for screws, allowing huge scope for development and improvement. Future work will include expanding the study to include more screw configurations as well as testing in higher density foams to compare performance in healthier bone


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1460 - 1465
1 Oct 2010
Rauh PB Clancy WG Jasper LE Curl LA Belkoff S Moorman CT

We evaluated two reconstruction techniques for a simulated posterolateral corner injury on ten pairs of cadaver knees. Specimens were mounted at 30° and 90° of knee flexion to record external rotation and varus movement. Instability was created by transversely sectioning the lateral collateral ligament at its midpoint and the popliteus tendon was released at the lateral femoral condyle. The left knee was randomly assigned for reconstruction using either a combined or fibula-based treatment with the right knee receiving the other. After sectioning, laxity increased in all the specimens. Each technique restored external rotatory and varus stability at both flexion angles to levels similar to the intact condition. For the fibula-based reconstruction method, varus laxity at 30° of knee flexion did not differ from the intact state, but was significantly less than after the combined method.

Both the fibula-based and combined posterolateral reconstruction techniques are equally effective in restoring stability following the simulated injury.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1257 - 1262
1 Sep 2009
Sundar S Pendegrass CJ Oddy MJ Blunn GW

We used demineralised bone matrix (DBM) to augment re-attachment of tendon to a metal prosthesis in an in vivo ovine model of reconstruction of the extensor mechanism at the knee. We hypothesised that augmentation of the tendon-implant interface with DBM would enhance the functional and histological outcomes as compared with previously reported control reconstructions without DBM. Function was assessed at six and 12 weeks postoperatively, and histological examination was undertaken at 12 weeks.

A significant increase of 23.5% was observed in functional weight-bearing at six weeks in the DBM-augmented group compared with non-augmented controls (p = 0.004). By 12 weeks augmentation with DBM resulted in regeneration of a more direct-type enthesis, with regions of fibrocartilage, mineralised fibrocartilage and bone. In the controls the interface was predominantly indirect, with the tendon attached to the bone graft-hydroxyapatite base plate by perforating collagen fibres.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1245 - 1251
1 Sep 2006
Pendegrass CJ Oddy MJ Sundar S Cannon SR Goodship AE Blunn GW

We examined the mechanical properties of Vicryl (polyglactin 910) mesh in vitro and assessed its use in vivo as a novel biomaterial to attach tendon to a hydroxyapatite-coated metal implant, the interface of which was augmented with autogenous bone and marrow graft. This was compared with tendon re-attachment using a compressive clamp device in an identical animal model. Two- and four-ply sleeves of Vicryl mesh tested to failure under tension reached 5.13% and 28.35% of the normal ovine patellar tendon, respectively. Four-ply sleeves supported gait in an ovine model with 67.05% weight-bearing through the operated limb at 12 weeks, without evidence of mechanical failure.

Mesh fibres were visible at six weeks but had been completely resorbed by 12 weeks, with no evidence of chronic inflammation. The tendon-implant neoenthesis was predominantly an indirect type, with tendon attached to the bone-hydroxyapatite surface by perforating collagen fibres.