Results per page:
Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_19 | Pages 1 - 1
1 Nov 2017
Mthethwa J Keen J
Full Access

Enterococcus faecalis is a rare but recognized cause of prosthetic joint infection. It is notorious for formation of biofilm on prosthetic surfaces. We hypothesized that a ‘serum factor’ was responsible for transformation of E. faecalis from its planktonic form to a biofilm existence upon making contact with prostheses. Using a novel ‘proteomic approach’, we studied the protein expression profiles of this bacterium when grown on an artificial surface in a serum environment against a control. E.faecalis 628 transconjugant formed by conjugation clinical strain (E55) and laboratory strain (JH2-2) was used to inoculate each of rabbit serum (RS) and Brain Heart Infusion (BHI) agar as a control and grown for 24 hours. Proteins were harvested for analysis in fractions including cell surface, membrane and cytosolic proteins. Recovered proteins were separated using 2-dimentional polyacrylamide gel electrophoresis (2D PAGE). Gels were stained and spots of interest harvested. These were analyzed using MALDI mass spectrometry followed by peptide mass fingerprinting using online database searches. Two surface exclusion proteins Sea1 and PrgA were only expressed from the serum culture. These proteins are both encoded by genes very close to the gene for enterococcal aggregation substance PrgB, which plays an integral role in biofilm formation. PrgA and PrgB are both encoded by the prgQ operon and hence expressed simultaneously upon activation of the operon. This tendency for serum only protein expression suggests the possibility of a pheromone-like activator in serum that could be a potential therapeutic target for management of biofilm associated E. faecalis prosthetic infections


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_7 | Pages 7 - 7
1 May 2019
Turnbull G Ning E Faulds K Riches P Shu W Picard F Clarke J
Full Access

Antimicrobial resistance (AMR) is projected to result in 10 million deaths every year globally by 2050. Without urgent action, routine orthopaedic operations could become high risk and musculoskeletal infections incurable in a “post-antibiotic era.” However, current methods of studying AMR processes including bacterial biofilm formation are 2D in nature, and therefore unable to recapitulate the 3D processes within in vivo infection. Within this study, 3D printing was applied for the first time alongside a custom-developed bioink to bioprint 3D bacterial biofilm constructs from clinically relevant species including Staphylococcus aureus (MSSA), Methicillin-resistant staphylococcus aureus (MRSA), Escherichia coli and Pseudomonas aeruginosa. Bacterial viability and biofilm formation in bioprinted constructs was excellent, with confocal laser scanning microscopy (CSLM) used to demonstrate biofilm production and maturation over 28 days. Bioprinted 3D MRSA and MSSA biofilm constructs had greater resistance to antimicrobials than corresponding two-dimensional (2D) cultures. Thicker 3D E.coli biofilms had greater resistance to tetracycline than thinner constructs over 7 days of treatment. Raman spectroscopy was also adapted in a novel approach to non-invasively diagnose 3D bioprinted biofilm constructs located within a joint replacement model. In conclusion, mature bacterial biofilm constructs were reproducibly 3D bioprinted for the first time using clinically relevant bacteria. This methodology allows the study of antimicrobial biofilm penetration in 3D, and potentially aids future antimicrobial research, replicating joint infection more closely than current 2D culture models. Furthermore, by deploying Raman spectroscopy in a novel fashion, it was possible to diagnose 3D bioprinted biofilm infections within a joint replacement model


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_8 | Pages 8 - 8
1 Feb 2013
Guthrie H Martin K Taylor C Spear A Clasper J Watts S
Full Access

A 7-day randomised controlled pre-clinical trial utilising an existing extremity war wound model compared the efficacy of saline soaked gauze to commercially available dressings. The Flexor Carpi Ulnaris of anaesthetised rabbits was exposed to high-energy trauma using a computer-controlled jig and inoculated with 10. 6. Staphylococcus aureus 3 hours prior to application of dressing. Quantitative microbiological assessment demonstrated reduced bacterial counts in INADINE (Iodine) and ACTICOAT (Nanocrystalline Silver) groups and an increase in ACTIVON TULLE (Manuka Honey) group (2-way ANOVA p<0.05). Clinical observations were made throughout the study. Haematology and plasma cytokines were analysed at intervals. Post-mortem histopathology included subjective semi-quantitative assessment of pathology severity using light microscopy to grade muscle injury and lymph node activation. Tissue samples were also examined using scanning electron microscopy (SEM). There were no bacteraemias, abscesses, purulent discharge or evidence of contralateral axillary lymph node activation. There were no significant differences in animal behaviour, weight change, maximum body temperature or white blood cell count elevation nor in pathology severity in muscle or lymph nodes (Kruskal-Wallis). There was no evidence of bacterial penetration or biofilm formation on SEM. Interleukin-4 and Tumour Necrosis Factor α levels were significantly higher in the ACTIVON TULLE group (1-way ANOVA p<0.05). This time-limited study demonstrated a statistically significant reduction in Staphylococcus aureus counts in wounds dressed with INADINE and ACTICOAT and an increase in wounds dressed with ACTIVON TULLE. There was no evidence that any of these dressings cause harm but nor have we established any definite clinical advantage associated with the use of the dressings tested in this study


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XV | Pages 16 - 16
1 Apr 2012
Brown K Bing BL Guda T Guelcher SA Wenke JC
Full Access

Introduction. Despite the routine use of irrigation, debridement and systemic antibiotics, there is a high incidence of infection in severe open fractures. The synergistic use of local and systemic antibiotics appreciably reduces infection rates although the time window within which this is effective is unknown. The aim was to determine if delaying treatment of wounds causes higher levels of infection. Methods. A defect was created in the femurs of 90 Sprague-Dawley rats and inoculated with 105CFUs Staphylococcus aureus. At 2, 6 and 24 hours following contamination, the defect was irrigated and debrided. The experimental groups had either vancomycin or tobramycin impregnated PMMA beads placed within the segmental defect. The controls received no further treatment. Two weeks after wound closure, the bacteria within the femur were quantified. Results. Delaying irrigation and debridement resulted in significantly more bacteria (p<0.01) within the control group (2 hr < 6 hr <24 hr). Both locally delivered tobramycin and vancomycin significantly reduced the bacteria (p<0.05) when administered at the earlier time points (2 and 6 hours). Locally-delivered antibiotics were ineffective when delivered at 24 hours. Conclusion. Delaying treatment of contaminated defects reduces its effectiveness to eradicate infection. This is presumably because of the biofilm formation by the bacteria. Biofilms begin to form within a couple of hours and are mature within 12 hours. Early treatment of the wound allows the surgeon to physically remove the bacteria or have antibiotics present before a mature biofilm protects the bacteria


Bone & Joint Open
Vol. 2, Issue 2 | Pages 72 - 78
1 Feb 2021
Agni NR Costa ML Achten J O’Connor H Png ME Peckham N Dutton SJ Wallis S Milca S Reed M

Aims

Patients receiving cemented hemiarthroplasties after hip fracture have a significant risk of deep surgical site infection (SSI). Standard UK practice to minimize the risk of SSI includes the use of antibiotic-loaded bone cement with no consensus regarding type, dose, or antibiotic content of the cement. This is the protocol for a randomized clinical trial to investigate the clinical and cost-effectiveness of high dose dual antibiotic-loaded cement in comparison to low dose single antibiotic-loaded cement in patients 60 years and over receiving a cemented hemiarthroplasty for an intracapsular hip fracture.

Methods

The WHiTE 8 Copal Or Palacos Antibiotic Loaded bone cement trial (WHiTE 8 COPAL) is a multicentre, multi-surgeon, parallel, two-arm, randomized clinical trial. The pragmatic study will be embedded in the World Hip Trauma Evaluation (WHiTE) (ISRCTN 63982700). Participants, including those that lack capacity, will be allocated on a 1:1 basis stratified by recruitment centre to either a low dose single antibiotic-loaded bone cement or a high dose dual antibiotic-loaded bone cement. The primary analysis will compare the differences in deep SSI rate as defined by the Centers for Disease Control and Prevention within 90 days of surgery via medical record review and patient self-reported questionnaires. Secondary outcomes include UK Core Outcome Set for hip fractures, complications, rate of antibiotic prescription, resistance patterns of deep SSI, and resource use (more specifically, cost-effectiveness) up to four months post-randomization. A minimum of 4,920 patients will be recruited to obtain 90% power to detect an absolute difference of 1.5% in the rate of deep SSI at 90 days for the expected 3% deep SSI rate in the control group.


Aims

The Intraosseous Transcutaneous Amputation Prosthesis (ITAP) may improve quality of life for amputees by avoiding soft-tissue complications associated with socket prostheses and by improving sensory feedback and function. It relies on the formation of a seal between the soft tissues and the implant and currently has a flange with drilled holes to promote dermal attachment. Despite this, infection remains a significant risk. This study explored alternative strategies to enhance soft-tissue integration.

Materials and Methods

The effect of ITAP pins with a fully porous titanium alloy flange with interconnected pores on soft-tissue integration was investigated. The flanges were coated with fibronectin-functionalised hydroxyapatite and silver coatings, which have been shown to have an antibacterial effect, while also promoting viable fibroblast growth in vitro. The ITAP pins were implanted along the length of ovine tibias, and histological assessment was undertaken four weeks post-operatively.


Bone & Joint Research
Vol. 5, Issue 9 | Pages 427 - 435
1 Sep 2016
Stravinskas M Horstmann P Ferguson J Hettwer W Nilsson M Tarasevicius S Petersen MM McNally MA Lidgren L

Objectives

Deep bone and joint infections (DBJI) are directly intertwined with health, demographic change towards an elderly population, and wellbeing.

The elderly human population is more prone to acquire infections, and the consequences such as pain, reduced quality of life, morbidity, absence from work and premature retirement due to disability place significant burdens on already strained healthcare systems and societal budgets.

DBJIs are less responsive to systemic antibiotics because of poor vascular perfusion in necrotic bone, large bone defects and persistent biofilm-based infection. Emerging bacterial resistance poses a major threat and new innovative treatment modalities are urgently needed to curb its current trajectory.

Materials and Methods

We present a new biphasic ceramic bone substitute consisting of hydroxyapatite and calcium sulphate for local antibiotic delivery in combination with bone regeneration. Gentamicin release was measured in four setups: 1) in vitro elution in Ringer’s solution; 2) local elution in patients treated for trochanteric hip fractures or uncemented hip revisions; 3) local elution in patients treated with a bone tumour resection; and 4) local elution in patients treated surgically for chronic corticomedullary osteomyelitis.


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1279 - 1283
1 Sep 2015
Mahale YJ Aga N

In this retrospective observational cohort study, we describe 17 patients out of 1775 treated for various fractures who developed mycobacterium tuberculosis (MTB) infection after surgery. The cohort comprised 15 men and two women with a mean age of 40 years (24 to 70). A total of ten fractures were open and seven were closed. Of these, seven patients underwent intramedullary nailing of a fracture of the long bone, seven had fractures fixed with plates, two with Kirschner-wires and screws, and one had a hemiarthroplasty of the hip with an Austin Moore prosthesis. All patients were followed-up for two years. In all patients, the infection resolved, and in 14 the fractures united. Nonunion was seen in two patients one of whom underwent two-stage total hip arthroplasty (THA) and the other patient was treated using excision arthoplasty. Another patient was treated using two-stage THA. With only sporadic case reports in the literature, MTB infection is rarely clinically suspected, even in underdeveloped and developing countries, where pulmonary and other forms of TB are endemic. In developed countries there is also an increased incidence among immunocompromised patients. In this paper we discuss the pathogenesis and incidence of MTB infection after surgical management of fractures and suggest protocols for early diagnosis and management.

Cite this article: Bone Joint J 2015;97-B:1279–83.