Advertisement for orthosearch.org.uk
Results 1 - 12 of 12
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 109 - 109
2 Jan 2024
Rahbek O Halloum A Rolfing J Kold S Abood A
Full Access

The concept of guided growth was proposed by Andry in 1741. In the last decades the concept has been widely used as implants has been introduced that can modulate the growth of the bone and pediatric longitudinal and angular deformities is widely treated by this technique. However, there is there is a huge variation in techniques and implants used and high-quality clinical trials is still lacking. Recently implants correcting rotational bony deformities have been proposed and clinical case series have been published. The current status of guided growth will be presented in this narrative review and preliminary experiences with rotational guided growth will be shared. Is guided growth to be considered a safe treatment at this time point?


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 66 - 66
14 Nov 2024
Tirta M Hjorth MH Jepsen JF Kold S Rahbek O
Full Access

Introduction. Epiphysiodesis, defined as the process of closing the growth plate (physis), have been used for several years as a treatment option of cases where the predicted leg-length discrepancy (LLD) falls between 2 to 5 cm. The aim of this study was to systematically review the existing literature on the effectiveness of three different epiphysiodesis techniques with implant usage for the treatment of leg-length discrepancy in the pediatric population. The secondary aim was to address the reported complications of staples, tension-band plates (TBP) and percutaneous epiphysiodesis screws (PETS). Method. This systematic review was performed according to PRISMA guidelines. We searched MEDLINE (PubMed), Embase, Cochrane Library, Web of Science and Scopus for studies on skeletally immature patients with LLD treated with epiphysiodesis with an implant. The extracted outcome categories were effectiveness of epiphysiodesis (LLD measurements pre/post-operatively, successful/unsuccessful) and complications that were graded on severity. Result. Forty-four studies (2184 patients) were included, from whom 578 underwent TBP, 455 PETS and 1048 staples. From pooled analysis of the studies reporting success rate, 64% (150/234) successful TBP surgeries (10 studies), 78% (222/284) successful PETS (9 studies) and 52% (212/407) successful Blount staples (8 studies). Severe complications rate was 7% for PETS, 17% for TBP and 16% for Blount staples. TBP had 43 cases of angular deformity (10%), Blount staples 184 (17%) while PETS only 18 cases (4%). Conclusion. Our results highlighted that PETS seems to be the most successful type of epiphysiodesis surgery with an implant, with higher success rate and lower severe complications than TBP or Blount staples


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 83 - 83
2 Jan 2024
Halloum A Kold S Rölfing J Abood A Rahbek O
Full Access

The aim of this scoping review is to understand the extent and type of evidence in relation to the use of guided growth for correcting rotational deformities of long bones. Guided growth is routinely used to correct angular deformities in long bones in children. It has also been proven to be a viable method to correct rotational deformities, but the concept is not yet fully examined. Databases searched include Medline, Embase, Cochrane Library, Web of Science and Google Scholar. All identified citations were uploaded into Rayyan.ai and screened by at least two reviewers. The search resulted in 3569 hits. 14 studies were included: 1 review, 3 clinical trials and 10 pre-clinical trials. Clinical trials: a total of 21 children (32 femurs and 5 tibiae) were included. Surgical methods were 2 canulated screws connected by cable, PediPlates obliquely oriented, and separated Hinge Plates connected by FiberTape. Rotation was achieved in all but 1 child. Adverse effects reported include limb length discrepancy (LLD), knee stiffness and rebound of rotation after removal of tethers. 2 pre-clinical studies were ex-vivo studies, 1 using 8-plates on Sawbones and 1 using a novel z-shaped plates on human cadaver femurs. There were 5 lapine studies (2 using femoral plates, 2 using tibial plates and 1 using an external device on tibia), 1 ovine (external device on tibia), 1 bovine (screws and cable on metacarp) and a case-report on a dog that had an external device spanning from femur to tibia. Rotation was achieved in all studies. Adverse effects reported include implant extrusions, LLD, articular deformities, joint stiffness and rebound. All included studies conclude that guided growth is a viable treatment for rotational deformities of long bones, but there is great variation in models and surgical methods used, and in reported adverse effects


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 33 - 33
17 Nov 2023
Goyal S Winson D Carpenter E
Full Access

Abstract. Objectives. Epiphysiodesis is a commonly used treatment for lower limb angular deformities. However, in recent years, distal tibial growth modulation using ‘eight plates’ or screws has emerged as an alternative treatment for paediatric foot and ankle disorders, such as CTEV. Our objective was to assess the efficacy of distal tibial modulation in correcting various paediatric foot and ankle disorders. Methods. This retrospective study analysed 205 cases of paediatric foot and ankle disorders treated between 2003 and 2022, including only cases where the eight plate or screw was fixed on the anterior surface of the distal tibia. Our aim was to measure post-operative changes in dorsiflexion, the distal tibial angle, and the tibiocalcaneal angle by examining clinical records and radiology reports. Results. We identified nine cases (nine feet) meeting the full inclusion criteria, comprising seven cases of CTEV, one case of arthrogryposis, and one case of cavovarus foot. The cohort consisted of five male and four female patients, with a mean age of 10 years and 9 months at the time of surgery. Seven cases involved the left tibia, and two cases involved the right tibia. The mean time between pre-operative X-ray to surgery was 168 days, and the mean turnaround time between surgery and post-operative X-ray was 588 days. A mean change in the distal tibial angle of 4.33 degrees was noted. However, changes in dorsiflexion were documented in only one case, which showed a change of 13 degrees. Notably, our average distal tibial angle was significantly lower than reported in the literature, at 4.33 degrees. Additionally, some studies in the literature used the Oxford Ankle Foot Questionnaire for Children to assess pre- and post-operative outcomes, but it is important to note that it is validated only for children aged 5 to 16. Furthermore, most cases reported an improved tibiocalcaneal angle except for an anomaly of 105 degrees. We assessed satisfactory patient outcomes using patient notes. Out of the 6 procured notes, one has been discharged. The rest are still under yearly or 6-monthly review and are at various stages, such as physiotherapy, removing the eight plate, or requiring further surgery. The most common presentations at review are plantaris deformity and pain. Conclusions. Our study suggests that distal tibial growth modulation can be an effective treatment option for selected paediatric foot and ankle disorders. However, due to the limited number of cases in our study, the lack of documentation of changes in dorsiflexion, and a lack of pre- and post-operative outcomes using a standardised method, further research is needed to investigate this procedure's long-term outcomes and potential complications. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 286 - 286
1 Jul 2014
Lee J Jeong C
Full Access

Summary Statement. The implantation of scaffold-free CTE from suspension culture into growth-plate defects resulted in a significant reduction in growth arrest of the rabbit tibia. Introduction. In childhood and adolescence, the growth plate injury can cause partial premature arrest of growth plate, which can make problems such as leg length discrepancy and angular deformity. Bone bridge resection and variable implantation materials such as fat, bone wax, silastic and craniopalst has been investigated. However, those procedures may show limitations including the control of bone growth and long term safety of implant materials in vivo. As an alternative, homogeneous or heterogeneous cartilage cells and stem cell transplants have been tried. In this method, scaffold for cell transplantation is needed. But, so far the most suitable scaffold has not been established. Recently, some authors generated a cartilage tissue equivalent (CTE) using a suspension culture with biophysical properties similar to native hyaline cartilage. Therefore we are able to transplant the CTE without scaffold to the physeal defect. The purpose of this study was to investigated the effects of a transplantation of a vitro-generated scaffold-free tissue-engineered cartilage tissue equivalent (CTE) using a suspension chondrocyte culture in a rabbit growth arrest model. Material and Method. Cartilage tissue equivalent culture. The CTE was generated by the suspension culture of chondrocytes (2 × 10. 7. /well/1 mL) which was isolated from articular cartilage of 5 weeks New Zealand white rabbit on a 24-well plate (2.4 cm. 2. /well) treated with poly HEMA (nunc, Roskide, Denmark) for up to 8 and 16 weeks. (2)Partial growth arrest animal model. An experimental model for growth arrest was created by excising the growth plate at the proximal medial side of tibia with the 4 mm in diameter and 4 mm in depth from 6-week-old New Zealand white rabbits. Two experimental groups were set to evaluate CTE implantation; group I, no implantation as controls; group II, implantation of CTE. (3) Evaluation of effect of the transplantation of CTE. Serial plain radiographs were performed at one week. The medial proximal tibial angle (MPTA) was measured for assessing the degree of angular deformity. Histologic examination using HE stain, Alcian bule and immunohistochemistry was done at 4 and 8 weeks after surgery. Results. Radiographic results: In group I, all damaged growth plates were arrested and angular deformities appeared 4 weeks later. In groups II, angular deformities were much less than in the control group. Histologic result: In group I, bone bridge formation was shown at the damaged growth plate at 4 weeks after surgery. In group II, regeneration of growth plates was recognised at 4 and 8 week after surgery. However, the thickness of regenerated growth plate at 8 weeks specimen was thinner than that of 4 weeks specimen. Discussion and Conclusion. The implantation of scaffold-free CTE from suspension culture into growth-plate defects resulted in a significant reduction in growth arrest of the rabbit tibia


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 96 - 96
1 Mar 2021
Abood A Rahbek O Moeller-Madsen B Kold S
Full Access

The use of retrograde femoral intramedullary nails in children for deformity correction is controversial. It is unknown if the injury to the central part of the growth plate results in premature bony union, leading to limb deformities or discrepancies. The aim of this study was to assess physeal healing and bone growth after insertion of a retrograde femoral nail thorough the centre of the physis in a skeletally immature experimental porcine model. Eleven immature pigs were included in the study. One leg was randomised for operation with a retrograde femoral nail (diameter 10.7 mm), whilst the non-operated contralateral remained as control. All nails were inserted centrally in coronal and sagittal plane under fluoroscopic guidance, and the nails spanned the physis. The nails were removed at 8 weeks. Both femora in all animals underwent MRI at baseline (pre-operatively), 8 weeks (after nail removal) and 16 weeks (before euthanasia). Femoral bone length was measured at 5 sites (anterior, posterior, central, lateral and medial) using 3d T1-weighted MRI. Growth was calculated after 8 weeks (growth with nail) and 16 weeks (growth without nail). Physeal cross-sectional area and percentage violated by the nail was determined on MRI. Operated side was compared to non-operated. Corresponding 95% confidence intervals were calculated. No differences in axial growth were observed between operated and non-operated sides. Mean growth difference was 0,61 mm [−0,78;2,01] whilst the nail was inserted into the bone and 0,72 mm [−1,04;1,65] after nail removal. No signs of angular bone deformities were found when comparing operated side to non-operated side. No premature bony healing at the physis occurred. Histology confirmed fibrous healing. Mean physeal violation was 5.72% [5.51; 5.93] by the femoral nail. The insertion of a retrograde femoral nail through the centre of an open physis might be a safe procedure with no subsequent growth arrest. However, experiments assessing the long term physeal healing and growth are needed


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 57 - 57
1 Dec 2020
Ateş YB Çullu E Çobanoğlu M
Full Access

Aim. To investigate the effect of the eight plate position in sagittal plane on tibial slope in temporary epiphysiodesis technique applied to the proximal tibia and whether there is a rebound effect after removing the plate. Method. Forty New Zealand rabbits (6 weeks old) were divided into four groups. In all groups, two 1.3 mm mini plates and cortical screws implantation were placed on both medial and lateral side of the proximal epiphysis of the right tibia. In Group 1 and 3, the plates were placed on anterior of the proximal tibial anatomical axis in the sagittal plane, and placed posteriorly in Group 2 and 4. The left tibia was examined as control in all groups. Group 1 and Group 2 were sacrificed after four week-follow-up. In Group 3 and Group 4, the implants were removed four weeks after index surgery and the rabbits were followed four more weeks to investigate the rebound effect. The tibial slope was measured on lateral X-rays every two weeks. Both medial and lateral plateau slopes were evaluated on photos of the dissected tibia. Results. In Group 1, right MTPA (medial tibial plateau angle) and left MTPA, right LTPA (lateral tibial plateau angle) and left LTPA, and right 4wTPPA (the tibial proximal posterior angle at 4th week) and left 4wTPPA values were compared with each other. There was a significant difference in MTPA, LTPA, and 4wTPPA in Group 1 (p: 0.003, 0.006, 0.004). In Group 1, the medial and lateral slope significantly decreased after 4 weeks. There was no significant difference in MTPA, LTP and 4wTPPA measurements in Group 2 (p= 0.719, 0.306, 0.446, respectively). In Group 2, the slope did not change in four weeks. There was a significant difference in MTPA, LTPA, 4wTPPA, and 8wTPPA (tibial proximal posterior angle at 8th week) in Group 3 (p= 0.005, 0.002, <0.001, <0.001, respectively). In Group 3, the slope decreased at 4th week and remained stabile during the next four week-follow up and no rebound effect was observed. There was no significant difference in MTPA, LTPA, 4wTPPA, and 8wTPPA measurements in Group 4 (p= 0.791, 0.116, 0.232, 0.924), respectively. In group 4, slope did not change at 4th week of index surgery and no rebound effect was observed in the next four week-follow up. Conclusion. If eight plates were placed on anterior of lateral proximal tibia axis on both medial and lateral side, the tibial slope would reduce, and remain stabile after implant removal. Care should be taken to place the plates on the line of proximal tibial axis in sagittal plane in temporary epiphysiodesis technique performed due to angular knee deformities. Changing the slope due to plate placement can be used as a secondary gain for patients who will benefit from slope change, such as adolescent ACL surgery


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 26 - 26
1 Aug 2013
Welsh F Martin D
Full Access

The aim is to report a rare technique for correction of intramedullary nail acute angular deformity. Intramedullary tibial nail fixation of diaphyseal tibial fractures is the gold standard treatment allowing early mobilisation whilst preserving the soft tissues around the fracture site. Most commonly, intramedullary nails fail by metal fatigue secondary to non union, without significant deformity of the metalwork. Plastic deformity of the nail can result following new acute trauma, particularly before bone union has occurred. This is a clinical challenge as a reamed intramedullary nail is designed to achieve three point fixation with close anatomical fit, such that removal of a bent nail is technically difficult and also risks further damage to bone and soft tissues. We report a case of a 20 year old patient treated with intramedullary nail fixation of a diaphyseal right tibial fracture who was subsequently assaulted 4 weeks post operatively. This produced an unacceptable deformation of the nail into 25 degrees valgus and procurvatum. To remove the nail, the authors used a previously reported but rare technique of partial (up to 50%) nail division on the convex surface of the apex using Midas Rex High Speed Drill to weaken the nail then manipulation to correct deformity with minimal stress. The technique produced minimal metal debris and allowed simple exchange nail replacement without further complication. The authors believe this is the first reported use of the technique from the United Kingdom


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 6 | Pages 979 - 983
1 Nov 1996
Simpson AHRW Cunningham JL Kenwright J

Axial forces were measured during limb lengthening in a series of ten patients with varying pathologies in order to assess the mechanical characteristics of the distracted tissues and the levels of axial force to which soft tissues are subjected during leg lengthening. The pattern of force was found to vary according to the underlying pathology. For post-traumatic shortening in adults both the peak and the resting forces rose steadily during lengthening reaching maximum forces of the order of 300 N. Patients with congenitally short limbs developed very high peak forces (in some cases over 1000 N) and also showed large amounts of force relaxation (typically 400 to 500 N). When very high levels of force were recorded, there was a higher complication rate. In particular, there was a high instance of angular deformity. This occurred because the loads encountered resulted in failure of some of the external fixation frames


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 7 | Pages 1070 - 1074
1 Sep 2002
Dumont CE Thalmann R Macy JC

We have assessed the influence of isolated and combined rotational malunion of the radius and ulna on the rotation of the forearm. Osteotomies were made in both the radius and the ulna at the mid-diaphyseal level of five cadaver forearms and stabilised with intramedullary metal implants. Malunion about the axis of the respective forearm bone was produced at intervals of 10°. The ranges of pronation and supination were recorded by a potentiometer under computer control. We examined rotational malunions of 10° to 80° of either the radius or ulna alone and combined rotational malunions of 20° to 60° of both the radius and ulna. Malunion of the ulna in supination had little effect on rotation of the forearm. Malunion of either the radius or of the ulna in pronation gave a moderate reduction of rotation of the forearm. By contrast, malunion of the radius in supination markedly reduced rotation of the forearm, especially with malunion greater than 60°. Combined rotational malunion produced contrasting results. A combination of rotational malunion of the radius and ulna in the same direction had an effect similar to that of an isolated malunion of the radius. A combination in the opposite direction gave the largest limitation of the range of movement. Clinically, rotational malunion may be isolated or part of a complex angular/rotational deformity and rotational malunion may lead to marked impairment of rotation of the forearm. A reproducible method for assessing rotational malunion is therefore needed


Bone & Joint Research
Vol. 3, Issue 11 | Pages 310 - 316
1 Nov 2014
Tomaszewski R Bohosiewicz J Gap A Bursig H Wysocka A

Objectives

The aim of this experimental study on New Zealand’s white rabbits was to investigate the transplantation of autogenous growth plate cells in order to treat the injured growth plate. They were assessed in terms of measurements of radiological tibial varus and histological characteristics.

Methods

An experimental model of plate growth medial partial resection of the tibia in 14 New Zealand white rabbits was created. During this surgical procedure the plate growth cells were collected and cultured. While the second surgery was being performed, the autologous cultured growth plate cells were grafted at the right tibia, whereas the left tibia was used as a control group.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 865 - 874
1 Jul 2012
Mills LA Simpson AHRW

This review is aimed at clinicians appraising preclinical trauma studies and researchers investigating compromised bone healing or novel treatments for fractures. It categorises the clinical scenarios of poor healing of fractures and attempts to match them with the appropriate animal models in the literature.

We performed an extensive literature search of animal models of long bone fracture repair/nonunion and grouped the resulting studies according to the clinical scenario they were attempting to reflect; we then scrutinised them for their reliability and accuracy in reproducing that clinical scenario.

Models for normal fracture repair (primary and secondary), delayed union, nonunion (atrophic and hypertrophic), segmental defects and fractures at risk of impaired healing were identified. Their accuracy in reflecting the clinical scenario ranged greatly and the reliability of reproducing the scenario ranged from 100% to 40%.

It is vital to know the limitations and success of each model when considering its application.