Progressive
Eight-plates are used to correct varus-valgus deformity (VVD) or limb-length discrepancy (LLD) in children and adolescents. It was reported that these implants might create a bony deformity within the knee joint by change of the roof angle (RA) after epiphysiodesis of the proximal tibia following a radiological assessment limited to anteroposterior (AP) radiographs. The aim of this study was to analyze the RA, complemented with lateral knee radiographs, with focus on the tibial slope (TS) and the degree of deformity correction. A retrospective, single-centre study was conducted. The treatment group (n = 64 knees in 44 patients) was subclassified according to the implant location in two groups: 1) medial hemiepiphysiodesis; and 2) lateral hemiepiphysiodesis. A third control group consisted of 25 untreated knees. The limb axes and RA were measured on long standing AP leg radiographs. Lateral radiographs of 40 knees were available for TS analysis. The mean age of the patients was 10.6 years (4 to 15) in the treatment group and 8.4 years (4 to 14) in the control group. Implants were removed after a mean 1.2 years (0.5 to 3).Aims
Methods
Aims. Temporary hemiepiphysiodesis (HED) is applied to children and adolescents to correct
Between 1990 and 2001, 24 children aged between 15 months and 11 years presented with late orthopaedic sequelae after meningococcal septicaemia. The median time to presentation was 32 months (12 to 119) after the acute phase of the disease. The reasons for referral included
Aims. Osteofibrous dysplasia (OFD) is a rare benign lesion predominantly affecting the tibia in children. Its potential link to adamantinoma has influenced management. This international case series reviews the presentation of OFD and management approaches to improve our understanding of OFD. Methods. A retrospective review at three paediatric tertiary centres identified 101 cases of tibial OFD in 99 patients. The clinical records, radiological images, and histology were analyzed. Results. Mean age at presentation was 13.5 years (SD 12.4), and mean follow-up was 5.65 years (SD 5.51). At latest review, 62 lesions (61.4%) were in skeletally mature patients. The most common site of the tibial lesion was the anterior (76 lesions, 75.2%) cortex (63 lesions, 62.4%) of the middle third (52 lesions, 51.5%). Pain, swelling, and fracture were common presentations. Overall, 41 lesions (40.6%) presented with radiological deformity (> 10°): apex anterior in 97.6%. A total of 41 lesions (40.6%) were treated conservatively. Anterior bowing < 10° at presentation was found to be related to successful conservative management of OFD (p = 0.013, multivariable logistic regression). Intralesional excision was performed in 43 lesions (42.6%) and a wide excision of the lesion in 19 (18.8%). A high complication rate and surgical burden was found in those that underwent a wide excision regardless of technique employed. There was progression/recurrence in nine lesions (8.9%) but statistical analysis found no predictive factors. No OFD lesion transformed to adamantinoma. Conclusion. This study confirms OFD to be a benign bone condition with low rates of local progression and without malignant transformation. It is important to distinguish OFD from adamantinoma by a histological diagnosis. Focus should be on
Percutaneous physiodesis is an established technique for treating mild leg-length discrepancy and problems of expected extreme height.
We used the Ilizarov method in seven patients with severe congenital radial club hands who had had previous wrist surgery, to correct residual shortening and bowing of the ulna together with recurrent wrist deformity. The mean age at operation was 6.5 years. The mean ulnar shortening was 5.3 cm and the mean
The aim was to assess the long-term impact of humeral and forearm rodding on functional ability, grip strength, joint range of motion and
The traditional techniques involving an oblique
tunnel or triangular wedge resection to approach a central or mixed-type
physeal bar are hindered by poor visualisation of the bar. This
may be overcome by a complete transverse osteotomy at the metaphysis
near the growth plate or a direct vertical approach to the bar.
Ilizarov external fixation using small wires allows firm fixation
of the short physis-bearing fragment, and can also correct an associated angular
deformity and permit limb lengthening. . We accurately approached and successfully excised ten central-
or mixed-type bars; six in the distal femur, two in the proximal
tibia and two in the distal tibia, without damaging the uninvolved
physis, and corrected the associated
This study aimed to define the rates of lower limb angular correction using temporary hemiepiphysiodesis in differing skeletal pathologies. A retrospective review of 61 children (36M:25F) with
Septicaemia resulting from meningococcal infection is a devastating illness affecting children. Those who survive can develop late orthopaedic sequelae from growth plate arrests, with resultant complex deformities. Our aim in this study was to review the case histories of a series of patients with late orthopaedic sequelae, all treated by the senior author (CFB). We also describe a treatment strategy to address the multiple deformities that may occur in these patients. Between 1997 and 2009, ten patients (seven girls and three boys) were treated for late orthopaedic sequelae following meningococcal septicaemia. All had involvement of the lower limbs, and one also had involvement of the upper limbs. Each patient had a median of three operations (one to nine). Methods of treatment included a combination of angular deformity correction, limb lengthening and epiphysiodesis. All patients were skeletally mature at the final follow-up. One patient with bilateral below-knee amputations had satisfactory correction of her right amputation stump deformity, and has complete ablation of both her proximal tibial growth plates. In eight patients length discrepancy in the lower limb was corrected to within 1 cm, with normalisation of the mechanical axis of the lower limb. Meningococcal septicaemia can lead to late orthopaedic sequelae due to growth plate arrests. Central growth plate arrests lead to limb-length discrepancy and the need for lengthening procedures, and peripheral growth plate arrests lead to
McFarland fractures of the medial malleolus in
children, also classified as Salter–Harris Type III and IV fractures,
are associated with a high incidence of premature growth plate arrest.
In order to identify prognostic factors for the development of complications
we reviewed 20 children with a McFarland fracture that was treated
surgically, at a mean follow-up of 8.9 years (3.5 to 17.4). Seven
children (35%) developed premature growth arrest with
We performed limb lengthening and correction of deformity of nine long bones of the lower limb in six children (mean age, 14.7 years) with osteogenesis imperfecta (OI). All had femoral lengthening and three also had ipsilateral tibial lengthening.
Meningococcal septicaemia from meningococcal infection is a devastating illness affecting children. Advances in medical management have reduced the mortality rate to approximately 15 to 20% and children who survive can develop late orthopaedic sequelae from growth plate arrests with resultant complex deformities. Our aim in this study was to review and analyze the case histories of a series of patients with late orthopaedic sequelae, all treated by the senior author. We describe a treatment strategy to address the multiple deformities that may occur in these patients. Methods & Results Between 1990 and 2009, 12 patients were treated for late orthopaedic sequelae after meningococcal septicaemia by the senior author. There were 8 girls and 4 boys. All patients had lower limb involvement. 1 patient had involvement of the upper limb requiring treatment. Each patient had had a mean of 3 operations (range from 2 to 9). Methods of treatment included a combination of angular deformity correction, limb lengthening and epiphysiodesis. At final follow-up 9 of the 12 patients were skeletally mature. In 9 patients limb length discrepancy in the lower limb was corrected to within 1 cm, with normalization of the lower limb mechanical axis. Conclusion. Meningococcal septicaemia can lead to late orthopaedic sequelae due to growth plate arrests. Central growth plate arrests leads to limb length discrepancy, and partial growth plate arrests leads to an
Aims. Guided growth using eight-plates is commonly used for correction
of
Originally used for correction of angular malalignment, 2 hole plate epiphyseodesis has recently gained popularity in paediatric orthopaedic practice for the correction of leg length discrepancy. In this study we aim to assess the efficiency of guided growth plates in correcting leg length discrepancy. Thirty-three children treated for leg length discrepancy with guided growth plates (“8-Plate”, Orthofix, Inc and “I-Plate”, Orthopediatrics) in a tertiary referral centre were retrospectively analysed. Medial and Lateral plates were inserted for symmetrical growth reduction and patients were followed up with clinical and radiological assessment. Thirty patients had distal femoral epiphyseodesis and three had proximal tibial epiphyseodesis. Leg lengths and individual bone lengths were measured from pre and post – operative radiographs. The angle between the screws was measured from radiographs taken intra operatively and at the time of final follow up to assess screw divergence with growth. Efficiency was calculated as the ratio of growth inhibition achieved to the projected discrepancy at maturity if left untreated. At a mean follow up of 17 months (4–30 m) leg length discrepancy improved from a mean of 30 mm (50–15mm) to 13 mm (2.5–39mm) (p < 0.01). The angle between screws increased from 6 degrees to 26 degrees over the follow up period. Efficiency was found to be 66%. There were 5 patients with
Purpose. The purpose of this study was to assess the accuracy of three-dimensional camera technology when monitoring deformity correction by an Ilizarov frame and to compare it to manual measurements. Methods and Results. A model consisting of an Ilizarov frame built around an artificial tibia and fibula was used with retro-reflective markers placed on the frame and bones to allow for the positions of each to be detected by the camera system. Measurements made by the camera system were compared to measurements taken manually. In the assessment of frame lengthening, the camera system average error was 2% (SD 2%) compared to 7% (SD 6%) for manual measurement. In the assessment of bone lengthening, the camera system average error was 4% (SD 4%) compared to 34% (SD 8%) for manual measurement. The technology also demonstrated good accuracy in the measurement of
Aims. Meningococcal septicaemia can result in growth arrest and
The purpose of this study was to determine the oblique plane deformity in slipped upper femoral epiphysis. A retrospective radiographic review was undertaken in patients admitted with a slipped upper femoral epiphysis between March 2008 and October 2010. Patients in whom a CT scan had been performed in addition to plain radiographs were assessed further.
Peripheral limb ischaemia is rare in children. We have treated only 12 infants and children with this condition in the past 15 years at the Royal Hospital for Sick Children in Glasgow. There were nine neonates and three older children. Most were suffering from life-threatening illnesses or severe infection. Two were born with ischaemic arms with no apparent cause. We have analysed the factors leading to ischaemia, the outcome of the initial treatment and the later orthopaedic problems. Two required amputation of both legs, one of an arm, two of feet and one of toes. Two had skin grafts. All surgery was performed after demarcation was well established and delayed closure was used after amputation. Five children developed limb-length discrepancy or an