Advertisement for orthosearch.org.uk
Results 1 - 20 of 25
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 290 - 290
1 Sep 2012
Cho BK Kim YM
Full Access

Introduction. This study was performed prospectively and randomly to compare clinical outcomes of modified-Brostrom procedure using single and double suture anchor for chronic lateral ankle instability. Material & Methods. Forty patients were followed up for more than 2 years after modified-Brostrom procedure for chronic lateral ankle instability. Twenty modified-Brostrom procedures with single suture anchor and 20 procedures with double suture anchor randomly assigned were performed by one surgeon. The mean age was 30.6 years, and the mean follow-up period was 2.6 years. The clinical evaluation was performed according to the Karlsson scale and Sefton grading system. The measurement of talar tilt angle and anterior talar translation was performed through anterior and varus stress radiographs. Results. At the last follow-up, the Karlsson scale had improved significantly from preoperative average 45.4 points to 90.5 points in single suture anchor group, from 46.2 points to 91.3 points in double suture anchor group. There were 8 excellent, 10 good, and 2 fair results according to the Sefton grading system in single anchor group, and 9 excellent, 8 good, 3 fair results in double anchor group. Therefore, 18 cases (90%) in single anchor group and 17 cases (85%) in double anchor group achieved satisfactory results. Talar tilt angle had improved significantly from preoperative average 15.7° to 6.1° in single anchor group, from 16.8° to 4.2° in double anchor group. There was significant difference in postoperative talar tilt angle between single and double anchor group. Conclusion. Significant differences in clinical and functional outcomes were not found between single and double suture anchor technique. On stress radiographs for evaluation of mechanical stability, modified-Brostrom procedure using double anchor showed less talar tilt angle than single anchor technique


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 249 - 253
1 Feb 2014
Euler SA Hengg C Kolp D Wambacher M Kralinger F

Antegrade nailing of proximal humeral fractures using a straight nail can damage the bony insertion of the supraspinatus tendon and may lead to varus failure of the construct. In order to establish the ideal anatomical landmarks for insertion of the nail and their clinical relevance we analysed CT scans of bilateral proximal humeri in 200 patients (mean age 45.1 years (sd 19.6; 18 to 97) without humeral fractures. The entry point of the nail was defined by the point of intersection of the anteroposterior and lateral vertical axes with the cortex of the humeral head. The critical point was defined as the intersection of the sagittal axis with the medial limit of the insertion of the supraspinatus tendon on the greater tuberosity. The region of interest, i.e. the biggest entry hole that would not encroach on the insertion of the supraspinatus tendon, was calculated setting a 3 mm minimal distance from the critical point. This identified that 38.5% of the humeral heads were categorised as ‘critical types’, due to morphology in which the predicted offset of the entry point would encroach on the insertion of the supraspinatus tendon that may damage the tendon and reduce the stability of fixation.

We therefore emphasise the need for ‘fastidious’ pre-operative planning to minimise this risk.

Cite this article: Bone Joint J 2014;96-B:249–53.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 497 - 497
1 Sep 2012
Spalazzi J Baldini T Efird C Traub S Hiza E Cook S Rioux-Forker D Mccarty E
Full Access

Summary. Strong mechanical fixation is critical to the success of rotator cuff repairs. In this comparative study in cadaveric shoulders, single-tendon full-thickness supraspinatus tears were repaired using two different types of PEEK knotless suture anchors-ReelX STT (Stryker) and Opus Magnum PI (Arthrocare)-using a single-row technique in both instances. Cyclic testing was performed followed by loading until mechanical failure. No significant difference was observed in gap formation, measured as the distance between the supraspinatus tendon and bone at the repair site, during cyclic loading. However, the maximum load was statistically higher for repairs with the ReelX anchor. Purpose. The objective of this study was to compare the gap formation during cyclic loading and maximum repair strength of single-row full thickness supraspinatus repairs performed using two different types of PEEK knotless suture anchors in a cadaveric model. Methods. Nine matched pairs of cadaveric shoulders were used in this study. All soft tissue was removed except for the supraspinatus, and a full thickness tear was formed. Single-row repairs were performed with two anchors per repair using either the Opus Magnum PI (Arthrocare) or the ReelX STT (Stryker). The specimens were mounted to an Instron at 45° to simulate an anatomic direction of load, and fiducial markers were placed on the repair in anterior and posterior positions. A 10 N preload was applied and held for 60 seconds, and then the tendon was cycled from 10 N to 90 N at 0.25 Hz for 500 cycles, followed by load to failure at 1 mm/s. A video digitizing system was used to track the markers and measure gap formation during loading. Gap formation was calculated by subtracting the distance between the markers at 10 N preload from the maximum displacement at 5 and 500 cycles. Paired t-tests were used to compare the cyclic displacement and max load. Results. One specimen from each of two matched pairs (one from each anchor group) failed during cyclic loading, leaving seven matched pairs for analysis. No significant difference was found in cyclic displacement between the two groups in either anterior or posterior positions at 5 and 500 cycles. However, maximum load to failure was significantly greater for repairs performed with the ReelX STT anchors (289N ± 57N) as compared to the OPUS anchors (178N ± 36N), with a p=0.009. Conclusions. These results suggest that the anchor type chosen for cuff repairs may affect the overall stability of the repair. Achieving stable fixation is critical for promoting healing of the tendon back to bone and to the long-term success of the repair, and using anchors that provide stronger fixation may decrease the occurrence of post-surgical tears and instability. The ReelX STT anchor outperformed the Opus Magnum PI anchor in terms of supporting significantly higher loads before failure, potentially leading to stronger repairs clinically


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 556 - 556
1 Sep 2012
Heikenfeld R Listringhaus R Godolias G
Full Access

Aim. The purpose of this study was to evaluate the results after arthroscopic reconstruction of isolated SSP lesions. Does double row repair in smaller lesions lead to better results and a lower retear rate?. Method. 80 patients with an isolated full thickness SSP tear were divided into 2 groups. Group 1 (27 men, 13 Frauen, average age 57 y.) was repaired using a single row technique with 2 anchors (Mitek Fastin) with arthroscopic Mason-Allen stiches. Group 2 was repaired using a double row technique using 1 medial anchor (Mitek Fastin) and 2 lateral anchors (Versalok). PreOP an ultrasound and MRI was obtained as well as standard x-rays (a.p., outlet-view, transaxial). Included to this study were only patients matching the following criteria: intraoperative cartilage lesions ≤ Outerbridge Grade2, fatty degeneration ≤ Goutallier Grade 2, ap extent of the tear < 2,5 cm. Prospective follow up after 6, 12 and 24 months using UCLA and Constant Score as well as MRI at last follow up. Results. 37 patients in group 1 and 36 patients in group 2 were completely evaluated. Both groups showed improvement in Constant Score from 49,3 to 89,4 in group 1 (single row) compared to 47,6 and 90,7 in group 2 (Double Row). MRI at last follow up showed 4 retears in the single row group and 3 retears in the double row group. 1 shoulder in the double row group needed revision due to a loose anchor. Discussion. We could not find any significant difference between clinical results and retear rate using a single or double row suture anchor configuration in isolated full thickness SSP tears


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 545 - 545
1 Sep 2012
Adib F Reddy C Guidi E Nirschl R Ochiai D Wolff A Wellborn C
Full Access

Introduction. Superior Labral Anterior Posterior Tears are being treated surgically in increasing numbers. Stiffness is the most common complication. We reviewed 115 cases of SLAP repairs to try and identify preoperative risk factors if any for stiffness. Methods. Retrospective cohort study of 115 patients who underwent SLAP repair. All patients failed attempts at conservative therapy including NSAIDS, Physical Therapy and cortisone injections. Results. Age ranged from 16–71 years, with an average age of 46. Male 84, Female 31. patient charts and operative notes were examined from 2004–2009. We used an average of 1.64 anchors per case; we performed arthroscopic Mumford on 15 patients, subscap repair (4), 19 cases with concomitant SLAP repair and Arthroscopic rotator cuff repair Other procedures included Biceps tenotomy and tenodesis, chondroplasty, Microfracture, removal of loose bodies, synovectomy and lysis of adhesions. Twelve patients underwent revision surgery(10%) We had 5 cases of stiffness which required lysis of adhesions and synovectomy, 4 cases had previous SLAP and concomitant rotator cuff repair done at the index surgery, 4 cases had arthrosis noted at index surgery and underwent chondroplasty and 2 of them underwent micro fracture. During the revision surgery 4 had also a concomitant cuff tear (new) which required repair Average time from index surgery to revision was 11 months, the patients who developed adhesive Capsulitis and stiffness the average age was 56 years. We had 2 titanium metal anchors pull out and present as loose bodies with one of the anchor causing chondral damage, we stopped using metal anchors and we have not had this problem recur since.5 cases had Mumford procedure done during the revision surgery.5 cases needed repeat SLAP repairs and by increasing use of biceps tenotomy this incidence should decrease. Conclusions. Our large retrospective case series shows an acceptable complication rate. Stiffness (5%) is still the most common complication especially in patients older than 50, withpreexisting Glenohumeral arthritis and concomitant rotator cuff tears. Hopefully our early aggressive mobilization will decrease this incidence


Bone & Joint Open
Vol. 3, Issue 12 | Pages 953 - 959
23 Dec 2022
Raval P See A Singh HP

Aims

Distal third clavicle (DTC) fractures are increasing in incidence. Due to their instability and nonunion risk, they prove difficult to treat. Several different operative options for DTC fixation are reported but current evidence suggests variability in operative fixation. Given the lack of consensus, our objective was to determine the current epidemiological trends in DTC as well as their management within the UK.

Methods

A multicentre retrospective cohort collaborative study was conducted. All patients over the age of 18 with an isolated DTC fracture in 2019 were included. Demographic variables were recorded: age; sex; side of injury; mechanism of injury; modified Neer classification grading; operative technique; fracture union; complications; and subsequent procedures. Baseline characteristics were described for demographic variables. Categorical variables were expressed as frequencies and percentages.


Bone & Joint Open
Vol. 5, Issue 3 | Pages 218 - 226
15 Mar 2024
Voigt JD Potter BK Souza J Forsberg J Melton D Hsu JR Wilke B

Aims

Prior cost-effectiveness analyses on osseointegrated prosthesis for transfemoral unilateral amputees have analyzed outcomes in non-USA countries using generic quality of life instruments, which may not be appropriate when evaluating disease-specific quality of life. These prior analyses have also focused only on patients who had failed a socket-based prosthesis. The aim of the current study is to use a disease-specific quality of life instrument, which can more accurately reflect a patient’s quality of life with this condition in order to evaluate cost-effectiveness, examining both treatment-naïve and socket refractory patients.

Methods

Lifetime Markov models were developed evaluating active healthy middle-aged male amputees. Costs of the prostheses, associated complications, use/non-use, and annual costs of arthroplasty parts and service for both a socket and osseointegrated (OPRA) prosthesis were included. Effectiveness was evaluated using the questionnaire for persons with a transfemoral amputation (Q-TFA) until death. All costs and Q-TFA were discounted at 3% annually. Sensitivity analyses on those cost variables which affected a change in treatment (OPRA to socket, or socket to OPRA) were evaluated to determine threshold values. Incremental cost-effectiveness ratios (ICERs) were calculated.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 496 - 496
1 Sep 2012
Huber M Zweymueller K Lintner F
Full Access

Background. Continual implant stability is an important factor for the long-term success of cementless hip replacements. The increasing lifespan of patients causes a higher frequency of osteoporosis which may result in implant loosening due to bone loss. This study aimed to evaluate stability of long living implants in patients with advanced age. Patients and methods. Nine cementless stems made of Titanium-alloy including adjacent bone tissue obtained post mortem were evaluated by radiologic-microradigraphical, histological and morphometrical analysis. The percentage of the surface area covered by bone (BICI=bone implant contact index) was determined. The age of seven women and two men ranged between 81 and 92 years. The time in situ ranged between 10 and 20 years. From the entire length of the femora bearing implants 5 transverse segments were excised, dehydrated, embedded in methylmethacrylate. After the grinding procedure, the sections were evaluated by light microscopy and morphometrical analysis. The autopsy findings were recorded. Atherosclerosis and their related diseases were evident in all cases. Results. The femora of all female patients revealed features of high bony atrophy with concomitant transformation of the corticalis into spongy bone, whereas in male patients minor to moderate atrophic bone changes in the proximal femoral area without implication of the corticalis could be observed. All of the cementless stems made of Titanium-alloy showed osteointegration. The stabilization of the implant resulted in the forceps-like encasement of the edges of the implant within the cortical anchoring and by the development of compensatory bony hypertrophy. The BICI ranged between 35 und 63 percent. Conclusion. Elderly patients provided with cementless hip replacments revealed stable implants in spite of marked bone atrophy and an implantation period up to 20 years. Simultaneously, severe atherosclerosis and their related diseases, which may contribute to bone loss, were evident. The present findings may result from the favoring properties of cementless endoprostheses made of titanium alloy, cortical prosthesis anchoring, and self regulating bone processes. Pharmacologic and therapeutic consequences together with geriatric assessment should be required to preserve functionality and mobility


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 274 - 274
1 Sep 2012
Morgan S Abdalla S Jarvis A
Full Access

Introduction. Trends in hallux valgus surgery continue to evolve. Basal metatarsal osteotomy theoretically provides the greatest correction, but is under-represented in the literature. This paper reports our early experience with a plate-fixed, opening- wedge basal osteotomy, combined with a new form of distal soft tissue correction (in preference to Akin phalangeal osteotomy). Materials and Methods. Thirty-three patients are reported here. The basal metatarsal osteotomy is fixed with the ‘Low Profile’ Arthrex titanium plate. No bone graft or filler is required, providing the osteotomy is within about 12mm of the base. Distal soft tissue correction comprised a full lateral release, and then proximal advancement of a complete capsular ‘sleeve’ on the medial side. The plate serves as a rigid anchoring point for the tensioning stitches. Using this technique, almost any degree of hallux valgus can be corrected, and there is even potential for over-correction. Functional outcome was assessed using the Manchester-Oxford foot and ankle score (MOXF). Radiographically the intermetatarsal angle was evaluated pre-operatively and at least 6 months postoperatively. Patients’ satisfaction and complication rates were recorded. Results. Clinical 87% (29 of 33) reported high satisfaction with the functional and cosmetic outcome. The opening basal wedge osteotomy slightly lengthens the first ray and as result none of our patients developed transfer metatarsalgia. Results. Radiology Hallux valgus angle (HVA) and inter-metatarsal angle (IMA) were measured on pre- and post-operative weight bearing radiographs. The radiological correction seen was very striking The mean correction of the IMA was 14 degrees; mean HVA correction was … degrees. Complications. One osteotomy was too distal, leading to a non-union, which required revision and bone grafting. Swelling and stiffness were seen in some patients, but these problems resolved steadily, with physiotherapy if needed. Discussion. This operation is a combined proximal/distal, bone/soft tissue procedure. It can obtain correction of almost any degree of hallux valgus. The slight first- ray lengthening is an advantage, as it neutralizes potential second ray problems. However, this is a very early result and long-term outcomes are as yet unknown


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 918 - 924
1 Jul 2020
Rosslenbroich SB Heimann K Katthagen JC Koesters C Riesenbeck O Petersen W Raschke MJ Schliemann B

Aims

There is a lack of long-term data for minimally invasive acromioclavicular (AC) joint repair. Furthermore, it is not clear if good early clinical results can be maintained over time. The purpose of this study was to report long-term results of minimally invasive AC joint reconstruction (MINAR) and compare it to corresponding short-term data.

Methods

We assessed patients with a follow-up of at least five years after minimally invasive flip-button repair for high-grade AC joint dislocation. The clinical outcome was evaluated using the Constant score and a questionnaire. Ultrasound determined the coracoclavicular (CC) distance. Results of the current follow-up were compared to the short-term results of the same cohort.


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 55 - 63
1 Jan 2020
Hagberg K Ghassemi Jahani S Kulbacka-Ortiz K Thomsen P Malchau H Reinholdt C

Aims

The aim of this study was to describe implant and patient-reported outcome in patients with a unilateral transfemoral amputation (TFA) treated with a bone-anchored, transcutaneous prosthesis.

Methods

In this cohort study, all patients with a unilateral TFA treated with the Osseointegrated Prostheses for the Rehabilitation of Amputees (OPRA) implant system in Sahlgrenska University Hospital, Gothenburg, Sweden, between January 1999 and December 2017 were included. The cohort comprised 111 patients (78 male (70%)), with a mean age 45 years (17 to 70). The main reason for amputation was trauma in 75 (68%) and tumours in 23 (21%). Patients answered the Questionnaire for Persons with Transfemoral Amputation (Q-TFA) before treatment and at two, five, seven, ten, and 15 years’ follow-up. A prosthetic activity grade was assigned to each patient at each timepoint. All mechanical complications, defined as fracture, bending, or wear to any part of the implant system resulting in removal or change, were recorded.


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 527 - 534
1 Apr 2018
Hansson E Hagberg K Cawson M Brodtkorb TH

Aims

The aim of this study was to compare the cost-effectiveness of treatment with an osseointegrated percutaneous (OI-) prosthesis and a socket-suspended (S-) prosthesis for patients with a transfemoral amputation.

Patients and Methods

A Markov model was developed to estimate the medical costs and changes in quality-adjusted life-years (QALYs) attributable to treatment of unilateral transfemoral amputation over a projected period of 20 years from a healthcare perspective. Data were collected alongside a prospective clinical study of 51 patients followed for two years.


The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1677 - 1680
1 Dec 2017
Herron J Hutchinson R Lecky F Bouamra O Edwards A Woodford M Eardley WGP

Aims

To compare the early management and mortality of older patients sustaining major orthopaedic trauma with that of a younger population with similar injuries.

Patients and Methods

The Trauma Audit Research Network database was reviewed to identify eligible patients admitted between April 2012 and June 2015. Distribution and severity of injury, interventions, comorbidity, critical care episodes and mortality were recorded. The population was divided into young (64 years or younger) and older (65 years and older) patients.


The Bone & Joint Journal
Vol. 99-B, Issue 8 | Pages 1095 - 1101
1 Aug 2017
Fuglesang HFS Flugsrud GB Randsborg PH Oord P Benth JŠ Utvåg SE

Aims

This is a prospective randomised controlled trial comparing the functional outcomes of plate fixation and elastic stable intramedullary nailing (ESIN) of completely displaced mid-shaft fractures of the clavicle in the active adult population.

Patients and Methods

We prospectively recruited 123 patients and randomised them to either plate fixation or ESIN. Patients completed the Quick Disabilities of the Arm, Shoulder and Hand (DASH) score at one to six weeks post-operatively. They were followed up at six weeks, three and six months and one year with radiographs, and their clinical outcome was assessed using both the DASH and the Constant Score.


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 508 - 515
1 Apr 2017
Haefeli PC Marecek GS Keel MJB Siebenrock KA Tannast M

Aims

The aims of this study were to determine the cumulative ten-year survivorship of hips treated for acetabular fractures using surgical hip dislocation and to identify factors predictive of an unfavourable outcome.

Patients and Methods

We followed up 60 consecutive patients (61 hips; mean age 36.3 years, standard deviation (sd) 15) who underwent open reduction and internal fixation for a displaced fracture of the acetabulum (24 posterior wall, 18 transverse and posterior wall, ten transverse, and nine others) with a mean follow-up of 12.4 years (sd 3).


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 983 - 987
1 Jul 2013
Soliman O Koptan W Zarad A

In Neer type II (Robinson type 3B) fractures of the distal clavicle the medial fragment is detached from the coracoclavicular ligaments and displaced upwards, whereas the lateral fragment, which is usually small, maintains its position. Several fixation techniques have been suggested to treat this fracture. The aim of this study was to assess the outcome of patients with type II distal clavicle fractures treated with coracoclavicular suture fixation using three loops of Ethibond. This prospective study included 14 patients with Neer type II fractures treated with open reduction and coracoclavicular fixation. Ethibond sutures were passed under the coracoid and around the clavicle (UCAC loop) without making any drill holes in the proximal or distal fragments. There were 11 men and three women with a mean age of 34.57 years (29 to 41). Patients were followed for a mean of 24.64 months (14 to 31) and evaluated radiologically and clinically using the Constant score. Fracture union was obtained in 13 patients at a mean of 18.23 weeks (13 to 23) and the mean Constant score was 96.07 (91 to 100). One patient developed an asymptomatic fibrous nonunion at one year. This study suggests that open reduction and internal fixation of unstable distal clavicle fractures using UCAC loops can provide rigid fixation and lead to bony union. This technique avoids using metal hardware, preserves the acromioclavicular joint and provides adequate stability with excellent results.

Cite this article: Bone Joint J 2013;95-B:983–7.


Bone & Joint Research
Vol. 5, Issue 5 | Pages 191 - 197
1 May 2016
Kienast B Kowald B Seide K Aljudaibi M Faschingbauer M Juergens C Gille J

Objectives

The monitoring of fracture healing is a complex process. Typically, successive radiographs are performed and an emerging calcification of the fracture area is evaluated. The aim of this study was to investigate whether different bone healing patterns can be distinguished using a telemetric instrumented femoral internal plate fixator.

Materials and Methods

An electronic telemetric system was developed to assess bone healing mechanically. The system consists of a telemetry module which is applied to an internal locking plate fixator, an external reader device, a sensor for measuring externally applied load and a laptop computer with processing software. By correlation between externally applied load and load measured in the implant, the elasticity of the osteosynthesis is calculated. The elasticity decreases with ongoing consolidation of a fracture or nonunion and is an appropriate parameter for the course of bone healing. At our centre, clinical application has been performed in 56 patients suffering nonunion or fracture of the femur.


Bone & Joint Research
Vol. 2, Issue 2 | Pages 26 - 32
1 Feb 2013
Neumann H Schulz AP Gille J Klinger M Jürgens C Reimers N Kienast B

Objectives

Osteochondral injuries, if not treated adequately, often lead to severe osteoarthritis. Possible treatment options include refixation of the fragment or replacement therapies such as Pridie drilling, microfracture or osteochondral grafts, all of which have certain disadvantages. Only refixation of the fragment can produce a smooth and resilient joint surface. The aim of this study was the evaluation of an ultrasound-activated bioresorbable pin for the refixation of osteochondral fragments under physiological conditions.

Methods

In 16 Merino sheep, specific osteochondral fragments of the medial femoral condyle were produced and refixed with one of conventional bioresorbable pins, titanium screws or ultrasound-activated pins. Macro- and microscopic scoring was undertaken after three months.


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 1004 - 1006
1 Jul 2015
Middleton SD McNiven N Griffin EJ Anakwe RE Oliver CW

We define the long-term outcomes and rates of further operative intervention following displaced Bennett’s fractures treated with Kirschner (K-) wire fixation between 1996 and 2009. We retrospectively identified 143 patients (127 men and 16 women) with a mean age at the time of injury of 33.2 years (18 to 75). Electronic records were examined and patients were invited to complete the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire in addition to a satisfaction questionnaire. The time since injury was a mean of 11.5 years (3.4 to 18.5). In total 11 patients had died, one had developed dementia and 12 patients were lost to follow-up. This left 119 patients available for recruitment. Of these, 57 did not respond, leaving a study group of 62 patients. Patients reported excellent functional outcomes and high levels of satisfaction at follow-up. Median satisfaction was 94% (interquartile range 91.5 to 97.5) and the mean DASH score was 3.0 (0 to 38). None of the patients had undergone salvage procedures and none of the responders had changed occupation or sporting activities. Long-term patient reported outcomes following displaced Bennett’s fractures treated by closed reduction and K-wire fixation show excellent functional results and a high level of patient satisfaction. The rate of infection is low and similar to other surgical procedures with percutaneous K-wires.

Cite this article: Bone Joint J 2015;97-B:1004–6.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1697 - 1702
1 Dec 2013
Maroto MD Scolaro JA Henley MB Dunbar RP

Bicondylar tibial plateau fractures result from high-energy injuries. Fractures of the tibial plateau can involve the tibial tubercle, which represents a disruption to the extensor mechanism and logically must be stabilised. The purpose of this study was to identify the incidence of an independent tibial tubercle fracture in bicondylar tibial plateau fractures, and to report management strategies and potential complications. We retrospectively reviewed a prospectively collected orthopaedic trauma database for the period January 2003 to December 2008, and identified 392 bicondylar fractures of the tibial plateau, in which 85 tibial tubercle fractures (21.6%) were identified in 84 patients. There were 60 men and 24 women in our study group, with a mean age of 45.4 years (18 to 71). In 84 fractures open reduction and internal fixation was undertaken, either with screws alone (23 patients) or with a plate and screws (61 patients). The remaining patient was treated non-operatively. In all, 52 fractures were available for clinical and radiological assessment at a mean follow-up of 58.5 weeks (24 to 94). All fractures of the tibial tubercle united, but 24 of 54 fractures (46%) required a secondary procedure for their tibial plateau fracture. Four patients reported pain arising from prominent tubercle plates and screws, which in one patient required removal. Tibial tubercle fractures occurred in over one-fifth of the bicondylar tibial plateau fractures in our series. Fixation is necessary and can be reliably performed with screws alone or with a screw and plate, which restores the extensor mechanism and facilitates early knee flexion.

Cite this article: Bone Joint J 2013;95-B:1697–1702.