Advertisement for orthosearch.org.uk
Results 1 - 16 of 16
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 96 - 96
4 Apr 2023
Pastor T Kastner P Souleiman F Gehweiler D Link B Beeres F Babst R Gueorguiev B Knobe M
Full Access

Helical plates are preferably used for proximal humeral shaft fracture fixation and potentially avoid radial nerve irritation as compared to straight plates. Aims:(1) to investigate the safety of applying different long plate designs (straight, 45°-, 90°-helical and ALPS) in MIPO-technique to the humerus. (2) to assess and compare their distances to adjacent anatomical structures at risk. MIPO was performed in 16 human cadaveric humeri using either a straight plate (group1), a 45°-helical (group2), a 90°-helical (group3) or an ALPS (group4). Using CT-angiography, distances between brachial arteries and plates were evaluated. Following, all specimens were dissected, and distances to the axillary, radial and musculocutaneous nerve were evaluated. None of the specimens demonstrated injuries of the anatomical structures at risk after MIPO with all investigated plate designs. Closest overall distance (mm(range)) between each plate and the radial nerve was 1(1-3) in group1, 7(2-11) in group2, 14(7-25) in group3 and 6(3-8) in group4. It was significantly longer in group3 and significantly shorter in group1 as compared to all other groups, p<0.001. Closest overall distance (mm(range)) between each plate and the musculocutaneous nerve was 16(8-28) in group1, 11(7-18) in group2, 3(2-4) in group3 and 6(3-8) in group4. It was significantly longer in group1 and significantly shorter in group3 as compared to all other groups, p<0.001. Closest overall distance (mm(range)) between each plate and the brachial artery was 21(18-23) in group1, 7(6-7) in group2, 4(3-5) in group3 and 7(6-7) in group4. It was significantly longer in group1 and significantly shorter in group3 as compared to all other groups, p<0.021. MIPO with 45°- and 90°-helical plates as well as ALPS is safely feasible and showed a significant greater distance to the radial nerve compared to straight plates. However, distances remain low, and attention must be paid to the musculocutaneous nerve and the brachial artery when MIPO is used with ALPS, 45°- and 90°-helical implants. Anterior parts of the deltoid insertion will be detached using 90°-helical and ALPS implants in MIPO-technique


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 47 - 47
2 Jan 2024
Grammens J Pereira LF Danckaers F Vanlommel J Van Haver A Verdonk P Sijbers J
Full Access

Currently implemented accuracy metrics in open-source libraries for segmentation by supervised machine learning are typically one-dimensional scores [1]. While extremely relevant to evaluate applicability in clinics, anatomical location of segmentation errors is often neglected. This study aims to include the three-dimensional (3D) spatial information in the development of a novel framework for segmentation accuracy evaluation and comparison between different methods. Predicted and ground truth (manually segmented) segmentation masks are meshed into 3D surfaces. A template mesh of the same anatomical structure is then registered to all ground truth 3D surfaces. This ensures all surface points on the ground truth meshes to be in the same anatomically homologous order. Next, point-wise surface deviations between the registered ground truth mesh and the meshed segmentation prediction are calculated and allow for color plotting of point-wise descriptive statistics. Statistical parametric mapping includes point-wise false discovery rate (FDR) adjusted p-values (also referred to as q-values). The framework reads volumetric image data containing the segmentation masks of both ground truth and segmentation prediction. 3D color plots containing descriptive statistics (mean absolute value, maximal value,…) on point-wise segmentation errors are rendered. As an example, we compared segmentation results of nnUNet [2], UNet++ [3] and UNETR [4] by visualizing the mean absolute error (surface deviation from ground truth) as a color plot on the 3D model of bone and cartilage of the mean distal femur. A novel framework to evaluate segmentation accuracy is presented. Output includes anatomical information on the segmentation errors, as well as point-wise comparative statistics on different segmentation algorithms. Clearly, this allows for a better informed decision-making process when selecting the best algorithm for a specific clinical application


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 84 - 84
4 Apr 2023
Gehweiler D Pastor T Beeres F Kastner P Migliorini F Nebelung S Scaglioni M Souleiman F Link B Babst R Gueorguiev B Knobe M
Full Access

Helical plates potentially bypass the medial neurovascular structures of the thigh. Recently, two plate designs (90°- and 180°-helix) proved similar biomechanically behaviour compared to straight plates. Aims of this study were: (1) Feasibility of MIPO-technique with 90°- and 180°-helical plates on the femur, (2) Assessment of distances to adjacent anatomical structures at risk, (3) Comparison of these distances to using medial straight plates instead, (4) Correlation of measurements performed in anatomic dissection with CT-angiography. MIPO was performed in ten cadaveric femoral pairs using either a 90°-helical 14-hole-LCP (Group1) or a 180°-helical 15-hole-LCP-DF (Group2). CT angiography was used to evaluate the distances between the plates and the femoral arteries as well as the distances between the plates and the perforators. Subsequently, the specimens were dissected, and the distances were determined again manually. Finally, all helical plates were removed, and all measurements were repeated after application of straight medial plates (Group3). Closest overall distances between plates and femoral arteries were 15 mm (11 − 19 mm) in Group1, 22 mm (15 − 24 mm) in Group2 and 6 mm (1 − 8 mm) in Group3 with a significant difference between Group1 and Group3 (p < 0.001). Distances to the nearest perforators were 24 mm (15 − 32 mm) in Group1 and 2 mm (1 − 4 mm) in Group2. Measurement techniques (visual after surgery and CT-angiography) demonstrated a strong correlation of r. 2. = 0.972 (p < 0.01). MIPO with 90°- and 180°-helical plates is feasible and safe. Attention must be paid to the medial neurovascular structures with 90°-helical implants and to the proximal perforators with 180°-helical implants. Helical implants can avoid medial neurovascular structures compared to straight plates although care must be taken during their distal insertion. Measurements during anatomical dissection correlate with CT-angiography


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 48 - 48
17 Nov 2023
Williams D Swain L Brockett C
Full Access

Abstract. Objectives. The syndesmosis joint, located between the tibia and fibula, is critical to maintaining the stability and function of the ankle joint. Damage to the ligaments that support this joint can lead to ankle instability, chronic pain, and a range of other debilitating conditions. Understanding the kinematics of a healthy joint is critical to better quantify the effects of instability and pathology. However, measuring this movement is challenging due to the anatomical structure of the syndesmosis joint. Biplane Video Xray (BVX) combined with Magnetic Resonance Imaging (MRI) allows direct measurement of the bones but the accuracy of this technique is unknown. The primary objective is to quantify this accuracy for measuring tibia and fibula bone poses by comparing with a gold standard implanted bead method. Methods. Written informed consent was given by one participant who had five tantalum beads implanted into their distal tibia and three into their distal fibula from a previous study. Three-dimensional (3D) models of the tibia and fibula were segmented (Simpleware Scan IP, Synopsis) from an MRI scan (Magnetom 3T Prisma, Siemens). The beads were segmented from a previous CT and co-registered with the MRI bone models to calculate their positions. BVX (125 FPS, 1.25ms pulse width) was recorded whilst the participant performed level gait across a raised platform. The beads were tracked, and the bone position of the tibia and fibula were calculated at each frame (DSX Suite, C-Motion Inc.). The beads were digitally removed from the X-rays (MATLAB, MathWorks) allowing for blinded image-registration of the MRI models to the radiographs. The mean difference and standard deviation (STD) between bead-generated and image-registered bone poses were calculated for all degrees of freedom (DOF) for both bones. Results. The absolute mean tibia and fibula bone position differences (Table 1) between the bead and BVX poses were found to be less than 0.5 mm for both bones. The bone rotation differences were found to be less than 1° for all axes except for the fibula Z axis rotation which was found to be 1.46°. One study. 1. has reported the kinematics of the syndesmosis joint and reported maximum ranges of motion of 9.3°and translations of 3.3mm for the fibula. The results show that the accuracy of the methodology is sufficient to quantify these small movements. Conclusions. BVX combined with MRI can be used to accurately measure the syndesmosis joint. Future work will look at quantifying the accuracy of the talus to provide further understanding of normal ankle kinematics and to quantify the kinematics across a healthy population to act as a comparator for future patient studies. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 19 - 19
1 Dec 2022
Belvedere C Ruggeri M Berti L Ortolani M Durante S Miceli M Leardini A
Full Access

Biomedical imaging is essential in the diagnosis of musculoskeletal pathologies and postoperative evaluations. In this context, Cone-Beam technology-based Computed Tomography (CBCT) can make important contributions in orthopaedics. CBCT relies on divergent cone X-rays on the whole field of view and a rotating source-detector element to generate three-dimensional (3D) volumes. For the lower limb, they can allow acquisitions under real loading conditions, taking the name Weight-Bearing CBCT (WB-CBCT). Assessments at the foot, ankle, knee, and at the upper limb, can benefit from it in situations where loading is critical to understanding the interactions between anatomical structures. The present study reports 4 recent applications using WB-CBCT in an orthopaedic centre. Patient scans by WB-CBCT were collected for examinations of the lower limb in monopodal standing position. An initial volumetric reconstruction is obtained, and the DICOM file is segmented to obtain 3D bone models. A reference frame is then established on each bone model by virtual landmark palpation or principal component analysis. Based on the variance of the model point cloud, this analysis automatically calculates longitudinal, vertical and mid-lateral axes. Using the defined references, absolute or relative orientations of the bones can be calculated in 3D. In 19 diabetic patients, 3D reconstructed bone models of the foot under load were combined with plantar pressure measurement. Significant correlations were found between bone orientations, heights above the ground, and pressure values, revealing anatomic areas potentially prone to ulceration. In 4 patients enrolled for total ankle arthroplasty, preoperative 3D reconstructions were used for prosthetic design customization, allowing prosthesis-bone mismatch to be minimized. 20 knees with femoral ligament reconstruction were acquired with WB-CBCT and standard CT (in unloading). Bone reconstructions were used to assess congruency angle and patellar tilt and TT-TG. The values obtained show differences between loading and unloading, questioning what has been observed so far. Twenty flat feet were scanned before and after Grice surgery. WB-CBCT allowed characterization of the deformity and bone realignment after surgery, demonstrating the complexity and multi-planarity of the pathology. These applications show how a more complete and realistic 3D geometric characterization of the of lower limb bones is now possible in loading using WB-CBCT. This allows for more accurate diagnoses, surgical planning, and postoperative evaluations, even by automatisms. Other applications are in progress


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 120 - 120
1 Nov 2021
Gregori P Singh A Harper T Franceschi F Blaber O Horneff JG
Full Access

Introduction and Objective. Total shoulder replacement is a common elective procedure offered to patients with end stage arthritis. While most patients experience significant pain relief and improved function within months of surgery, some remain unsatisfied because of residual pain or dissatisfaction with their functional status. Among these patients, when laboratory workup eliminates infection as a possibility, corticosteroid injection (CSI) into the joint space, or on the periprosthetic anatomic structures, is a common procedure used for symptom management. However, the efficacy and safety of this procedure has not been previously reported in shoulder literature. Materials and Methods. A retrospective chart review identified primary TSA patients who subsequently received a CSI into a replaced shoulder from 2011 – 2018 by multiple surgeons. Patients receiving an injection underwent clinical exam, laboratory analysis to rule out infection, and radiographic evaluation prior to CSI. Demographic variables were recorded, and a patient satisfaction survey assessed the efficacy of the injection. Results. Of the 43 responders, 48.8% remembered the injection. The average time from index arthroplasty to injection was median 16.8 months. Overall, 61.9% reported decreased pain, 28.6% reported increased motion, and 28.6% reported long term decreased swelling. Improvement lasted greater than one month for 42.9% of patients, and overall 52.4% reported improvement (slight to great) in the shoulder following CSI. No patient developed a periprosthetic joint infection (PJI) within 2 years of injection. Conclusions. This study suggests that certain patients following TSA may benefit from a CSI. However, this should only be performed once clinical, radiographic, and laboratory examination has ruled out conditions unlikely to improve long term from a CSI. Given these findings, further study in a large, prospective trial is warranted to fully evaluate the benefits of CSI following TSA


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_3 | Pages 7 - 7
1 Apr 2015
Bhattacharyya R Ker A Fogg Q Joseph J
Full Access

Background:. The Lateral Intercondylar Ridge (LIR) gained notoriety with arthroscopic trans-tibial Anterior Cruciate Ligament (ACL) reconstruction where it was mistakenly used to position the ‘over the top’ guide resulting in graft malposition. With anatomic ACL reconstruction some surgeons use the same ridge to define the anterior margin of the ACL femoral insertion in order to guide graft placement. However there is debate about whether this ridge is a consistent and reliable anatomical structure. The aim of our study was to identify whether the LIR is a consistent anatomical structure and to define its relationship with the femoral ACL insertion. Methods:. In the first part, we studied 23 dry bone specimens. Using a digital microscribe, we created a 3D model of the medial surface of the lateral femoral condyle to evaluate whether there was an identifiable bony ridge. In the second part, we studied 7 cadaveric specimens with soft tissues intact. The soft tissues were dissected to identify the femoral ACL insertion. A 3D reconstruction of the femoral insertion and the surface allowed us to define the relationship between the LIR and the ACL insertion. Results:. All specimens (23 dry bones; 7 intact soft tissues) had a defined ridge on the medial surface of the lateral femoral condyle. The ridge extends from the apex point of the lateral intercondylar notch, where the posterior condyle meets the femoral shaft, and extends obliquely to the articular margin. The mean distance from the midpoint of the posterior condylar articular margin was 10.1 mm. The ridge was consistently located just anterior to the femoral ACL insertion. Conclusion:. This study shows that the LIR is a consistent anatomical structure that defines the anterior margin of the femoral ACL insertion. This supports its use as a landmark for femoral tunnel placement in ACL reconstruction surgery. Abstract 28


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_7 | Pages 17 - 17
1 Apr 2014
Bhattacharyya R Ker A Fogg Q Joseph J
Full Access

Background:. The term ‘resident's ridge’ originated from trans-tibial ACL reconstruction where a bony ridge on the medial surface of the lateral femoral condyle was mistakenly thought to represent the posterior articular margin of the condyle. This was then mistakenly used to position the ‘over the top’ guide resulting in graft malposition. With anatomical anteromedial ACL reconstruction some surgeons use the same ridge to define the anterior margin of the ACL femoral insertion in order to guide graft placement. However there is debate about whether this ridge is a consistent and reliable anatomical structure. There are no anatomical studies that define the features of the ‘resident's ridge’. Therefore, our aim was to identify whether the ‘resident's ridge’ is a consistent anatomical structure in non-operated human cadaveric femoral specimens. Methods:. Using a digital microscribe, we mapped the medial surface of the lateral femoral condyle in cadaveric human femora denuded of soft tissue. This technique creates an exact 3D model of surfaces and from this we evaluated whether there was an identifiable bony ‘residents ridge’. 23 cadaveric specimens were used. Results:. All 23 specimens had a defined identifiable ridge on the medial surface of the lateral femoral condyle. When viewed anatomically, the proximal extent of the ridge lies at the superior junction of the articular margin and the femoral shaft. From this point, the ridge forms an oblique line travelling proximal-to-distal and anterior-to-posterior to a point approximately 30–40% anterior to the posterior articular margin. The ridge therefore divides the medial surface into anterior 2/3. rd. and posterior 1/3. rd. when viewed anatomically. Conclusion:. This study shows that the “resident's ridge” is a consistent anatomical structure that defines the anterior margin of the ACL insertion. This therefore supports its use as a landmark for femoral tunnel placement in ACL reconstruction surgery


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 91 - 91
1 Nov 2021
Aljasim O Yener C Demirkoparan M Bilge O Küçük L Gunay H
Full Access

Introduction and Objective. Zone 2 flexor tendon injuries are still one of the challenges for hand surgeons. It is not always possible to achieve perfect results in hand functions after these injuries. There is no consensus in the literature regarding the treatment of zone 2 flexor tendon injuries, tendon repair and surgical technique to be applied to the A2 pulley. The narrow fibro-osseous canal structure in zone 2 can cause adhesions and loss of motion due to the increase in tendon volume due to surgical repair. Different surgical techniques have been defined to prevent this situation. In our study, in the treatment of zone 2 flexor tendon injuries; Among the surgical techniques to be performed in addition to FDP tendon repair; We aimed to compare the biomechanical results of single FDS slip repair, A2 pulley release and two different pulley plasty methods (Kapandji and V-Y pulley plasty). Materials and Methods. In our study, 12 human upper extremity cadavers preserved with modified Larssen solution (MLS) and amputated at the mid ½ level of the arm were used. A total of 36 fingers (second, third and the fourth fingers were used for each cadaver) were divided into four groups and 9 fingers were used for each group. With the finger fully flexed, the FDS and FDP tendons were cut right in the middle of the A2 pulley and repaired with the cruciate four-strand technique. The surgical techniques described above were applied to the groups. Photographs of fingers with different loads (50 – 700 gr) were taken before and after the application. Proximal interphalangeal (PIP) joint angle, PIP joint maximum flexion angle and bowstring distance were measured. The gliding coefficient was calculated by applying the PIP joint angle to the single-phase exponential association equation. Results. Gliding coefficient after repair increased by %21.46 ± 44.41, %62.71 ± 116.9, %26.8 ± 35.35 and %20.39 ± 28.78 in single FDS slip repair, A2 pulley release, V-Y pulley plasty and Kapandji plasty respectively. The gliding coefficient increased significantly in all groups after surgical applications (p<0.05). PIP joint maximum flexion angle decreased by %3.17 ± 7.92, %12.82 ± 10.94, %8.33 ± 3.29 and %7.35 ± 5.02 in single FDS slip repair, A2 pulley release, V-Y pulley plasty and Kapandji plasty respectively. PIP joint maximum flexion angle decreased significantly after surgery in all groups (p<0.05). However, there was no statistically significant difference between surgical techniques for gliding coefficient and PIP joint maximum flexion angle. Bowstring distance between single FDS slip repair, kapandji pulley plasty and V-Y pulley plasty showed no significant difference in most loads (p>0.05). Bowstring distance was significantly increased in the A2 pulley release group compared to the other three groups (p<0.05). Conclusion. Digital motion was negatively affected after flexor tendon repair. Similar results were found in terms of gliding coefficient and maximum flexion angle among different surgical methods. As single FDS slipe repair preserves the anatomical structure of the A2 pulley therefore we prefer it as an ideal method for zone 2 flexor tendon repair. However, resection of FDS slip may jeopardizes nutrition to the flexor digitorum profundus tendon which weakens the repair site. Therefore the results must be confirmed by an in vivo study before a clinical recommendation can be made. Keywords: Flexor tendon; injury; pulley plasty; cadaver;


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 39 - 39
1 Mar 2021
Pavan M Barbera C Galesso D Beninatto R Pluda S
Full Access

Osteoarthritis (OA) is a joint degenerative disease leading to chronic pain and disability, thus resulting in a major socioeconomic health burden. OA, which has long been believed to be a cartilage disease, is now considered a whole-joint disorder affecting various anatomical structures, including subchondral bone. Hyaluronic Acid (HA) is commonly used as intra-articular viscosupplementation therapy for its mechanical features and biological effects. Bisphosphonates (BPs) are antiresorptive agents inhibiting recruitment and maturation of osteoclast precursors and activity of mature osteoclasts in the bone. Pre-clinical evidences in the literature, show that intra-articular BPs could impact on OA progression, slowing down or reversing it. The combination of HA biological and mechanical role and Alendronate (ALD) antiresorptive effect could be an interesting strategy for OA treatment. This study describes the synthesis and characterization of FID-134, a new chemical derivative of HA conjugated with ALD by means of a covalent bond, cleavable in physiological condition. FID-134 was synthesized starting from 500 kDa HA: chemical structure and functionalization degree with ALD were investigated by NMR and ICP-OES. Kinetics of ALD release from FID-134 was determined in TRIS buffer at 37°C and compared to a simple mixture of HA+ALD. 20mg/mL formulations of FID-134 and HA+ALD were investigated for viscoelastic properties, in absence and presence of Ca. 2+. ions. The cytotoxicity of FID-134 and free ALD were tested on Saos-2 osteoblasts (ATCC HTB-85) and on primary bovine chondrocytes (PBC) at day 1, 3 and 7. The efficacy of FID-134 was assessed in an inflammatory arthritis in vitro model, where bovine cartilage biopsies were exposed to IL-1β/OSM (10ng/mL) for 3 weeks; at the same time, cartilage explants were treated with FID-134. Collagen release in the surnatants was quantified and compared to controls. FID-134 structure was confirmed by NMR and the 20% mol/mol functionalization degree was determined by ICP-OES. Only about 50% of total bound ALD was released from FID-134 within 7 days, resulting slower compared to HA+ALD mixture. In presence of Ca. 2+. ions, viscoelastic properties of FID-134 dramatically improved, while HA+ALD formulation remained unaffected. The cytotoxicity of ALD was evident at 100 μM on Saos-2 and PBC after 3 days, while no cytotoxicity was observed at 7 days with FID-134. In the cartilage explant model, a strong collagen release was detected in inflammatory conditions after 3 weeks; this tendency was reversed, and collagen release halved when FID-134 was added to the biopsies. The synthesized HA-ALD adduct, FID-134, opens the door for a new approach for OA treatment. The results suggest that FID-134 could be beneficial in cartilage degradation and in restoration of subchondral bone function. Finally, local administration and controlled BP release would likely overcome the drawbacks of ALD oral administration, such as unspecific features and long-term toxic side effects


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 20 - 20
1 Mar 2013
Bhattacharjee A Menan C Wright K Roberts S Richardson JB
Full Access

The potential of cells derived from human umbilical cord(UC) for orthopaedic cell engineering is evaluated by dissecting the UC into four distinct anatomical structures – cord lining (CL), Wharton's Jelly (WJ), umbilical cord artery (UCA) and umbilical cord vein (UCV). Cells from individual anatomical layers were grown by explant culture technique for 21 days. Tri-lineage differentiation and growth kinetics of cells from each layer were compared. Flowcytometry was done according to ISCT criteria to ascertain their surface antigen expressions. Cells from all four layers differentiated into bone, cartilage and fat. Osteogenic and chondrogenic differentiation was variable for each type of cells. All cells expressed surface antigens characteristic of mesenchymal stem cells (MSC). These cells can form a potential cell source in cell engineering to produce bone and cartilage although individual cell type needs to be characterised from each anatomical layer of UC and identify the best cell type for cell engineering


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 178 - 178
1 Jul 2014
Zheng K Scholes C Lynch J Parker D Li Q
Full Access

Summary Statement. An MRI-derived subject-specific finite element model of a knee joint was loaded with subject-specific kinetic data to investigate stress and strain distribution in knee cartilage during the stance phase of gait in-vivo. Introduction. Finite element analysis (FEA) has been widely used to predict the local stress and strain distribution at the tibiofemoral joint to study the effects of ligament injury, meniscus injury and cartilage defects on soft tissue loading under different loading conditions. Previous studies have focused on static FEA of the tibiofemoral joint, with few attempts to conduct subject-specific FEA on the knee during physical activity. In one FEA study utilising subject-specific loading during gait, the knee was simplified by using linear springs to represent ligaments. To address the gap that no studies have performed subject-specific FEA at the tibiofemoral joint with detailed structures, the present study aims to develop a highly detailed subject-specific FE model of knee joint to precisely simulate the stress distribution at knee cartilage during the stance phase of the gait cycle. Method. A detailed three-dimensional model of a healthy human knee was developed from MRI images of a living subject, including the main anatomical structures (bones, all principal ligaments, menisci and articular cartilages). The femur, tibia and fibula were considered as rigid bodies, while the menisci and articular cartilage were modelled as linearly elastic, isotropic and homogeneous while the ligaments were considered to be hyperelastic. Loading and boundary condition assignment was based on the kinematic and kinetic data recorded during gait analysis. Ten time intervals during the stance phase of gait were separately simulated to quantify the time–dependent stress distribution throughout the cycle from heel-strike to toe-off. Loading condition of the tibiofemoral joint varys during the gait cycle since the joint angle changes from extension to flextion, therefore different joint angles at relative time interval were determined to accurately simulate the varing loading condition. Results. The compressive stress and tensile strain distributions in the femoral cartilage, tibia cartilage and menisci of each selected time interval during the stance phase of gait cycle were quantified and corresponded to specific amount of varus/valgus knee moment obtained by inverse dynamics analysis of the kinematic and kinetic data from gait analysis. Therefore a correlation between stress/strain and the frontal movement was established and analysed. For example, at 10% of stance phase, the stress concentration was observed on the lateral compartment due to the valgus moment created at heel strike. At the next interval, the stress concentration shifted to the medial side as the frontal knee moment shifted to a varus orientation. Discussion. The results suggest that the stress distribution of tibiofemoral articular cartilage is qualitatively consistent with the valgus and varus moment observed during the stance phase of gait. The methods described could be applied to investigate the effects of injury and reconstruction on stress distribution within the tibiofemoral joint


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 53 - 53
1 May 2012
Alsousou J Larry L McNally E Noble A Willett K
Full Access

Purpose. Functional ultrasound Elastography (FUSE) of Tendo Achilles is an ultrasound technique utilising controlled, measurable movement of the foot to non-invasively evaluate TA elastic and load-deformation properties. The study purpose is to assess Achilles tendons, paratenon and bursa mechanical properties in healthy volunteers and establish an outcome tool for TA treatment. Methods. Forty asymptomatic Achilles tendons of 20 healthy volunteers were recruited (10 men and 10 women, age range 18-55). One patient with Acute Achilles rupture scanned to evaluate the tendon gap. Each volunteer answered the Foot and Ankle Outcome Score (FAOS) and Victorian Institute Sport Assessment score (VISA-A) questionnaires. The Achilles Tendons were divided into three thirds (total 120 Proximal, middle and distal thirds). Three longitudinal images of each third were obtained using portable US scan device (Z.one, Zonare Medical System Inc., USA, 8.5 MHz). Images processing was achieved using a MatLAb software (developed by the research team) in parallel Oxford university computers. Each 1/3rd Achilles tendon under went the following scans: . Free hand US scan. Free hand Compression decompression Elastography scan. Dorsal Flexion elastography. Planter flexion elastography. Zonare real-time Elastography. Elastography scan with the Oxford isometric dynamic foot and Ankle mover (OIDFA). B mode and elasticity images were derived from the raw ultrasound radio frequency data. The anatomical structures mechanical properties were evaluated by a quantitative score of different colours representing stiff tissue (blue) to more soft tissue (green, yellow, red). Results. The Achilles tendons showed mainly a hard structured pattern (82.5%) (99/120 tendon thirds) on sonoelastography; however, mild softening was found in 17.5% (21/120) of the tendons. Therefore, suggesting subclinical changes. The minimal lateral movement of the tendon produced by applying the FOAIDM resulted in well defined elasticity images with tendon in blue colour (stiff) and surrounding soft tissues. The average strain along the tendon was 2% (range 0-6%). The overall correlation (κ) between real-time sonoelastography and ultrasound findings was < 0.3. However, the correlation (κ) between FUSE UEI and US findings was 1.0. Patients with Achilles tendon rupture lateral strain and axial elastography images using FUSE methods revealed a larger gap with spreading of the haematoma along the paratenon. Conclusion. Our findings show that FUSE seems to be a sensitive method for assessment of TA mechanical properties. The B mode and elasticity images must be viewed simultaneously. FUSE method can easily identify the regeneration of ruptured TA. Elasticity and stiffness measurement may offer an invaluable tool to guide TA rupture and tendenopathy treatment and rehabilitation protocols


Bone & Joint 360
Vol. 7, Issue 5 | Pages 41 - 42
1 Oct 2018
Foy MA


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 169 - 175
1 Jan 2010
Dutton AQ Choong PF Goh JC Lee EH Hui JHP

We hypothesised that meniscal tears treated with mesenchymal stem cells (MSCs) together with a conventional suturing technique would show improved healing compared with those treated by a conventional suturing technique alone. In a controlled laboratory study 28 adult pigs (56 knees) underwent meniscal procedures after the creation of a radial incision to represent a tear. Group 1 (n = 9) had a radial meniscal tear which was left untreated. In group 2 (n = 19) the incision was repaired with sutures and fibrin glue and in group 3, the experimental group (n = 28), treatment was by MSCs, suturing and fibrin glue.

At eight weeks, macroscopic examination of group 1 showed no healing in any specimens. In group 2 no healing was found in 12 specimens and incomplete healing in seven. The experimental group 3 had 21 specimens with complete healing, five with incomplete healing and two with no healing. Between the experimental group and each of the control groups this difference was significant (p < 0.001).

The histological and macroscopic findings showed that the repair of meniscal tears in the avascular zone was significantly improved with MSCs, but that the mechanical properties of the healed menisci remained reduced.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 527 - 534
1 Apr 2008
Merican AM Amis AA

Anatomical descriptions of the lateral retinaculum have been published, but the attachments, name or even existence of its tissue bands and layers are ill-defined. We have examined 35 specimens of the knee. The deep fascia is the most superficial layer and the joint capsule is the deepest. The intermediate layer is the most substantial and consists of derivatives of the iliotibial band and the quadriceps aponeurosis. The longitudinal fibres of the iliotibial band merge with those of the quadriceps aponeurosis adjacent to the patella. These longitudinal fibres are reinforced by superficial arciform fibres and on the deep aspect by transverse fibres of the iliotibial band. The latter are dense and provide attachment of the iliotibial band to the patella and the tendon of vastus lateralis obliquus.

Our study identifies two important new findings which are a constant connection of the deep fascia to the quadriceps tendon superior and lateral to the patella, and, a connection of the deeper transverse fibres to the tendon of vastus lateralis obliquus.