Introduction. There are controversies in the literature about thoracoplasty and its effect on lung function changes. The aim of the study was to evaluate the effect and outcome of thoracoplasty in conjunction with pedicle screw construct in the treatment of thoracic
The routine use of intraoperative vancomycin powder to prevent postoperative wound infections has not been borne out in the literature in the pediatric spine population. The goal of this study is to determine the impact of vancomycin powder on postoperative wound infection rates and determine its potential impact on microbiology. A retrospective analysis of the Harms Study Group database of 1269
7% of
Orthopaedic paediatric deformities, globally, are often corrected later than initial identification due to resource constraints (bed availability, investigative modalities, surgical skill set). The study aims to analyse experiences and challenges met with running a flagship scoliosis surgery week in a tertiary public health care facility, with the goal of reducing patient waiting time on the waiting list. In this retrospective study, patients from an existing deformity correction waiting list were selected for a 5 day scoliosis surgery week. Investigations relevant to clinical findings were carried out and patients were scheduled on a “one patient per day” surgery list. Inclusion criteria was any patient with
The purpose of this study is to evaluate risk factors for distal construct failure (DCF) in posterior spinal instrumented fusion (PSIF) in
This study aimed to identify factors associated with increased rates of blood transfusion in patients with
Despite the myriad new spinal instrumentation systems, scoliosis can rarely be fully corrected, especially when the curves are stiff. A novel superelastic nickel-titanium (nitinol) rod that maximises the ability to slowly correct spinal deformities by utilising the viscoelastic properties of the spine has been developed. This parallel, double-blinded, randomised controlled trial compared the safety and efficacy of these new rods to conventional titanium rods in 23 patients with
The etiology of
Rapid discharge pathways (RDP) have been implemented throughout most areas of orthopaedics. The primary goal of these pathways is to standardize the post-surgical hospital course for patients in order to decrease hospital length-of-stay (LOS). Surgical treatment of
To examine the effect of lateral spine curvature on somatosensory evoked potentials (SSEP) in patients with
Aim. Nasal colonization with S.aureus (SA) is a risk factor for developing nosocomial infections in cardiac surgery. However, the risk in orthopedic surgery remains unclear, especially in
The evolution of operative technology has allowed correction of complex spinal deformities. Neurological deficits following spinal instrumentation is a devastating complication and the risk is especially high in those with complex sagittal and coronal plane deformities. Prior to intraoperative evoked potential monitoring, spinal cord function was tested using the Stagnara Wake up test, typically performed after instrumentation once the desired correction has been achieved. This test is limited as it does not reflect the timeframe in which the problem occurred and it may be dangerous to some patients. Intraoperative neuromonitoring allows timely feedback of the effect of instrumentation and curve correction on the spinal cord. Pedicle screws that are malpositioned can result in poor fixation or neuronal injury. Evoked EMG monitoring can aid in accurate placement. A positive EMG response can alert the surgeon to a potential pedicle breech and allow them to reassess the placement of their hardware intraoperatively. The stimulation threshold is affected by the amount of surrounding bone acting as an insulator to electrical conduction and is variable in different regions of the spine. In the non-deformed, lumbar spine stimulation thresholds have been established. Such guidelines have not been well-developed for the thoracic spine, or for severely scoliotic spines. Thus our primary objective was to compare the stimulation threshold of the apical pedicle on the concave side to the stimulation threshold of the pedicles at the upper and lower instrumented levels. Intraoperative EMG stimulation thresholds were done at 192 apical pedicles on the concave side of the deformity and then compared to those thresholds found at 169 terminal level pedicles. Only pedicles for which a stimulation threshold was found were reported and excluded those where a breech was suspected. The lowest stimulation required for an EMG response was documented to a maximum stimulation of 20 mA. The mean threshold at the apex was 16.62 milliamps (mA) compared to 18.25mA at the terminal levels. This was compared with the t-test and showed a statistically significant difference (p<0.05). In this study we report only the thresholds for the concave side, the pedicle that is most likely to be reduced in size. The threshold for stimulation is reduced compared to those seen at the highest and lowest instrumented level. Most of the apexes are located in the mid-thoracic spine with the highest instrumented levels being in the high thoracic spine and the lowest levels being in the lumbar spine. This study provides preliminary evidence that the apical, concave pedicle has a lower threshold than the end pedicles and one cannot rely on established thresholds from different areas of the spine. The surgeon should be cognisant of these differences when instrumenting at the apical level. Ongoing work is examining the convex apex threshold as well as the relationship between the effect of age and a diagnosis other than
Revision surgery and surgery in previously operated areas are associated with an increased infection risk. In such situations, aggressive surgical debridement may be necessary to control and eradicate the infection. Full thickness defects resulting from such debridement present as a challenge. In most cases, an association of various methods, both surgical and non-surgical, is necessary. Our goal is to describe the use of vaccum dressings as an effective way to deal with extensive and infected dorsolumbar surgical defects, while avoiding the use of myocutaneous flaps. This is a retrospective and descriptive case report based on data from clinical records, patient observation and analysis of complementary exams. We present the case of a 57-years-old obese woman with prior history of double approach with posterior instrumentation and spine arthrodesis (D3 to L4) due to severe dorsolumbar
Summary. Optimum position of pedicle screws can be determined preoperatively by CT based planning. We conducted a comparative study in order to analyse manually determined pedicle screw plans and those that were obtained automatically by a computer software and found an agreement in plans between both methods, yet an increase in fastening strengths was observed for automatically obtained plans. Hypothesys. Automatic planning of pedicle screw positions and sizing is not inferior to manual planning. Design. Prospective comparative study. Introduction. Preoperative planning in spinal deformity surgery starts by a proper selection of implant anchors throughout the instrumented spine, where pedicle screws provide the optimum choice for bone fixation. In the case of severe spinal deformities, dysplastic pedicles can limit screw usage, and therefore studying the anatomy of vertebrae from preoperative images can aid in achieving the safest screw position through optimal fastening strength. The purpose of this study is to compare manually and automatically obtained preoperative pedicle screw plans. Materials and Methods. CT scans of 17 deformed thoracic spines were studied by two experienced spine deformity surgeons, who placed 316 pedicle screws in 3D using a software positioning tool by aiming for the safest trajectory that permitted the largest possible screw sizes. The resulting manually obtained screw sizes, trajectory angles, entry points and normalised fastening strengths were compared to those obtained automatically by a dedicated computer software that, basing on vertebral anatomy and bone density in 3D, determined optimal screw sizes and trajectories. Results. Statistically significant differences were observed between manually and automatically obtained plans for screw sizes (p < 0.05) and trajectory angles (p < 0.001). However, for automatically obtained plans, screws were not smaller in diameter (p < 0.05) or shorter in length (p < 0.001), while screw normalised fastening strengths were higher (p < 0.001). Conclusions. In comparison to manual planning, automatically obtained plans did not result in smaller screw diameters or shorter screw lengths, which is in agreement with the definition of the pull-out strength, but in different screw trajectory angles, which is reflected by higher normalised fastening strengths. Captions. Fig. 1. Visual comparison among automatically obtained (green colour) and manually defined pedicle screw placement plans by two experienced spine surgeons (red and blue colour) for three different patients with
Subjects. A prospective study of 127 patients who underwent posterior spinal arthrodesis and segmental spinal instrumentation with iliac crest bone graft for correction of
Introduction. Idiopathic scoliosis is a lateral curvature of the spine >10° as measured on a frontal plane radiograph by the Cobb angle. Important variables in assessing the risk of curve progression include a young age at presentation, female sex, a large amount of growth remaining, the rate of growth, the curve magnitude, and the curve location. Curves >20° have an inherently low risk of progression. Surgery is indicated for curves >50° or rapidly progressing curves. The timing of surgery is paramount in order to intervene in cases where rapid progression is evident to prevent further deterioration. There is a greater likelihood for more complex surgery to be required in major curves. At present, there are severe restrictions on resources to cater for patients with scoliosis. As a result, patients spend excessive periods on waiting lists prior to having their procedure. The aim of this study is to analyse the progression of curves of patients while on the waiting list and assess the cost implications of curve deterioration. Methods. A retrospective analysis of 40 cases of
The accuracy of pedicle screw placement is essential for successful spinal reconstructive surgery. The authors of several previous studies have described the use of image-based navigational templates for pedicle screw placement. These are designed based on a pre-operative computed tomographic (CT) image that fits into a unique position on an individual's bone, and holes are carefully designed to guide the drill or the pedicle probe through a pre-planned trajectory. The current study was conducted to optimise navigational template design and establish its designing method for safe and accurate pedicle screw placement. Thin-section CT scans were obtained from 10 spine surgery patients including 7 patients with