Advertisement for orthosearch.org.uk
Results 1 - 20 of 23
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 957 - 963
1 Sep 2024
Baek CH Kim JG Kim BT

Aims. Favourable short-term outcomes have been reported following latissimus dorsi tendon transfer for patients with an irreparable subscapularis (SSC) tendon tear. The aim of this study was to investigate the long-term outcomes of this transfer in these patients. Methods. This was a retrospective study involving 30 patients with an irreparable SSC tear and those with a SSC tear combined with a reparable supraspinatus tear, who underwent a latissimus dorsi tendon transfer. Clinical scores and active range of motion (aROM), SSC-specific physical examination and the rate of return to work were assessed. Radiological assessment included recording the acromiohumeral distance (AHD), the Hamada grade of cuff tear arthropathy and the integrity of the transferred tendon. Statistical analysis compared preoperative, short-term (two years), and final follow-up at a mean of 8.7 years (7 to 10). Results. There were significant improvements in clinical scores, in the range and strength of internal rotation and aROM compared with the preoperative values in the 26 patients (87%) who were available for long-term follow-up. These improvements were maintained between short- and long-term follow-ups. Although there was a decreased mean AHD of 7.3 mm (SD 1.5) and an increased mean Hamada grade of 1.7 (SD 0.5) at final follow-up, the rate of progression of cuff tear arthropathy remained low-grade. Comparison between the isolated SSC and combined SSC and reparable supraspinatus tear groups showed no significant differences. At final follow-up, one patient (3.8%) had undergone revision surgery to a reverse shoulder arthroplasty (RSA). No neurological complications were associated with the procedure. Conclusion. Latissimus dorsi transfer for an irreparable SSC tendon tear resulted in a significant clinical improvement, particularly in pain, range and strength of internal rotation and aROM, which were maintained over a mean of 8.7 years following surgery. Given that this was a long-term outcome study, there was a low-grade progression in the rate of cuff tear arthropathy. Thus, the long-term clinical efficacy of latissimus dorsi tendon transfer in patients with irreparable SSC was confirmed as a joint-preserving procedure for these patients, suggesting it as an effective alternative to RSA in young, active patients without degenerative changes of the glenohumeral joint. Cite this article: Bone Joint J 2024;106-B(9):957–963


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 208 - 212
1 Feb 2006
Habermeyer P Magosch P Rudolph T Lichtenberg S Liem D

We describe 14 patients who underwent transfer of latissimus dorsi using a new technique through a single-incision. Their mean age was 61 years (47 to 76) and the mean follow-up was 32 months (19 to 42). The mean Constant score improved from 46.5 to 74.6 points. The mean active flexion increased from 119° to 170°, mean abduction from 118° to 169° and mean external rotation from 19° to 33°. The Hornblower sign remained positive in three patients (23%) as did the external rotation lag sign also in three patients (23%). No patient had a positive drop-arm sign at follow-up. No significant difference was noted between the mean pre- and postoperative acromiohumeral distance as seen on radiographs. An increased grade of osteoarthritis was found in three patients (23%). Electromyographic analysis showed activity of the transferred muscle in all patients


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 51 - 51
1 Jan 2013
Xypnitos F Sims A Weusten A Rangan A
Full Access

Background. Accurate and reproducible radiological assessment of shoulder replacement prostheses over time is important for identifying failure or to provide reassurance. A number of clearly defined radiological parameters have been described to help standardise the radiological assessment of prostheses. To our knowledge, this is the first study conducted to test the reproducibility and reliability of these measurements. Aim. The aim of this work was to test intraobserver reproducibility and interobserver reliability in the measurement of humeral component orientation (HCO), humeral head offset (HHO), humeral head size (HHS), humeral head height (HHH), and acromiohumeral distance (AHD.). Materials and methods. A cohort of 67 patients who had previously undergone shoulder replacement was identified. Two independent reviewers studied the same AP radiograph of each patient on two occasions, at an interval of one month. Results. There was strong agreement for measurements of humeral head size (ICC=0.83), moderate agreement for humeral head offset (0.66), humeral head height (0.68) and acromio-humeral distance (0.66) and fair agreement for humeral component orientation (0.44). Conclusions. Interobserver reliability and intraobserver reproducibility of radiological measurements are important factors to consider when designing longitudinal or multi-centre studies of shoulder replacement prostheses


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 159 - 159
1 Mar 2009
Gruber G Bernhardt G Clar H Wurnig C
Full Access

Background: An acromiohumeral interval narrower than six millimeters has been considered pathologic and strongly indicative for rotator cuff tears by numerous authors. This prospective study was conducted as an assessment of inter- and intraobserver variation in the radiographic measurement of the acromiohumeral interval and its critical value. Material and Methods: Thirty blinded, standardized anteroposterior shoulder radiographs were independently reviewed by five board certified orthopedic shoulder surgeons. The acromiohumeral distance, from the inferior anterior acromial aspect to the humeral head was measured in millimeters. The five investigators classified each film a second time in random order. Results: Finally the same 27 radiographs (90%) have been evaluated by five investigators at both examination time points. The results of three investigators showed significant intra-observer variation ranging from 4 to 11 millimeters for the same radiograph. Six investigator pairs showed significant inter-observer variation at both examination time points (p< 0.05). The maximum inter-observer difference for the same radiograph was 11 millimeters (ranging from 1 to 11, SD 0.3 – 4.2). Conclusion: In view of our results the assessment of the acromiohumeral interval using anteroposterior x-rays does not seem to be a reproducible method of measurement. Further investigations in combination with CT or MRI are necessary to ensure our findings


Purpose: The purpose of the study was to evaluate the clinical and radiological results of Copeland cementless surface replacement arthroplasty (CSRA) applied in patients with two main indications. Patients and Methods: The study was conducted on fifty shoulders in fifty patients between 2003 and 2005; 17 patients suffered from rotator cuff pathology. The patients were prospectively followed up clinically and radiologically for a mean of 12.7 months (range, 6–30 months). There were 30 female and 20 male shoulders. The mean age was 66.63 years (range, 21–85). The mean operative time was 44.6 minutes (range, 29–62 minutes). The clinical assessment was performed with the Constant score. Results: The constant score significantly improved from a mean of 15.52 points preoperatively to 57.02 points postoperatively. Of the patients, 96% considered the shoulder to be much better or better as a result of the operation. The Constant-Score improved in the group with degenerative arthritis from 16.32 point pre- to 62.25 postoperatively. In rotator cuff arthropathy the score improved from 14.19 to 53.06. Radiologically, the humeral offset, the lateral gleno-humeral offset (coracoid base to the greater tuberosity) as well as the acromiohumeral distance were significantly increased. No intra-or postoperative complications encountered. Conclusion: We conclude that the shoulder surface replacement arthroplasty allows good conservation of the bone stock and avoiding the complications encountered with the stemmed prostheses. In patients with rotator cuff arthropathy there are two main indications:. - patients below the age of 70, in order to avoid complications of the reverse prosthesis. - patients with still a goof active range of motion


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 294 - 294
1 Mar 2004
Postacchini F Gumina S
Full Access

Aims: We studied the prevalence of calciþc tendinopathy in asymptomatic subjects and the relationship between calciþc deposits and the anatomopathological characteristic of coracoacromial arch. Methods: 222 right-handed volunteers underwent x-ray examination of the right shoulder. We measured the acromiohumeral distance (AHD) and evaluated the acromion shape and the degenerative changes of the GH and AC joints. We measured the size of the deposits and classiþed the calciþcations based on their location, shape and neatness. The subjects with deposits were clinically evaluated and underwent a second x-ray study after 14 months. Results: 11 subjects (5%) had calciþcation. The latter was in the substance of supraspinatus in 5(mean age 45 yrs) and at cuff insertion in 6 (66 yrs). The deposits measured 0.7±0.3cm (avg). There were 3 linear and 2 beanlike intratendinous calciþcations and 5 linear and 1 beanlike deposits at tendon insertion. Calciþcations had well-deþned margins. AHD, acromion shape, arthritic of the GH or AC joint were unrelated to the presence of calciþcations. No subject showed evidence of cuff tear. Intratendinous deposit decreased in size in 2 cases and disappeared in 1. Conclusions: 5% of asymptomatic subjects have calciþcations. Calciþcations are always small and well-deþned. Morphology and changes of the cora-coacromial arch or the GH or AC joint donñt inßuence the deposition of calcium. Our study suggests that calciþcations may decrease in size or disappear without completion of Uhthoffñs cycle


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 229 - 229
1 May 2009
Bicknell R Boileau P Chuinard C
Full Access

The purpose of this study was to evaluate outcome following arthroscopic biceps tenotomy or tenodesis for massive irreparable rotator cuff tears associated with biceps lesions. This is a retrospective study of sixty-eight consecutive patients (mean age 68 ± 6 years) with seventy-two irreparable rotator cuff tears treated with arthroscopic biceps tenotomy (thirty-nine cases) or tenodesis (thirty-three cases). All patients were evaluated clinically and radiographically at a mean follow-up of thirty-five months (range, 24–52). Fifty-three patients (78%) were satisfied. Constant score improved from forty-six to sixty-seven points (p< 0.001). Presence of a healthy, intact teres minor on preoperative imaging correlated with increased postoperative external rotation (40 vs. 18°, p< 0.05) and higher Constant score (p< 0.05). Three patients with a pseudoparalyzed shoulder did not benefit from the procedure and did not regain active elevation above the horizontal level. By contrast, fifteen patients with painful loss of active elevation recovered active elevation. The acromiohumeral distance decreased 1 mm on average, and only one patient developed glenohumeral osteoarthritis. There was no difference between tenotomy and tenodesis (Constant Score sixty-one vs. seventy-three). A “Popeye” sign was clinically apparent in twenty-four tenotomy patients (61%), but none were bothered by it. Two patients required reoperation with a reverse prosthesis. Arthroscopic biceps tenotomy and tenodesis effectively treats severe pain or dysfunction caused by an irreparable rotator cuff tear associated with biceps pathology. Shoulder function is significantly lower if the teres minor is atrophic or fatty infiltrated. Pseudoparalysis or severe cuff arthropathy are contraindications


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 575 - 575
1 Oct 2010
Szabò I Edwards B Neyton L Nove-Josserand L Walch G
Full Access

The long head of the biceps tendon has been proposed as a source of pain in patients with rotator cuff tears. The purpose of this study is to evaluate the objective, subjective, and radiographic results of arthroscopic biceps tenotomy in selected patients with rotator cuff tears. Three hundred seven arthroscopic biceps tenotomies were performed in patients with full thickness rotator cuff tears. All patients had previously failed appropriate nonoperative management. Patients were selected for arthroscopic tenotomy if the tear was thought to be irreparable or the patient was older and not willing to participate in the rehabilitation required following rotator cuff repair. One hundred eleven shoulders underwent a concomitant acromioplasty. The mean age at surgery was 64.3 years. The mean preoperative radiographic acromiohumeral interval measured 6.6 mm. Patients were evaluated clinically and radiographically at a mean 57 months follow-up (range 24 to 168 months). The mean Constant score increased from 48.4 points preoperatively to 67.6 points postoperatively (p < 0.0001). Eighty-seven percent of patients were satisfied or very satisfied with the result. Nine patients underwent an additional surgical procedure (three for attempt at rotator cuff repair and six for reverse prostheses for cuff tear arthropathy). The acromiohumeral interval decreased by a mean. 1.3 mm during the follow-up period and was associated with longer duration of follow-up (p < 0.0001). Preoperatively, 38% of patients had glenohumeral arthritis; postoperatively, 67% of patients had glenohumeral arthritis. Concomitant acromioplasty was statistically associated with better subjective and objective results only in patients with an acromiohumeral distance greater than 6 mm. Fatty infiltration of the rotator cuff musculature had a negative influence on both the functional and radiographic results (p < 0.0001). Arthroscopic biceps tenotomy in the treatment of rotator cuff tears in selected patients yields good objective improvement and a high degree of patient satisfaction. Despite these improvements, arthroscopic tenotomy does not appear to alter the progressive radiographic changes that occur with long standing rotator cuff tears


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 281 - 281
1 Sep 2012
Arndt J Clavert P Daemgen F Dosch J Moussaoui A Penz C Kempf J
Full Access

Introduction. Latissimus dorsi transfer is a procedure used in massive irreparable posterosuperior rotator cuff tears, in young patient with severe pain and significant functional impairment. The purpose of this retrospective study was to evaluate its clinical, radiological and electromyographic results. Methods. Forteen massive irreparable posterosuperior rotator cuff tears were performed with latissimus dorsi transfer between 2000 and 2008, and were reviewed at an average follow-up of 56 months and minimum of 19 months. Five transfers were primary reconstructions, and nine were revision surgeries. Patients’ mean age was 52.7 years. Clinical outcomes were measured by the Constant score, pain level, active range of motion, and strength. Osteoarthritis and acromiohumeral distance were measured on standardized radiographs. Ultrasound examination evaluate the integrity of the tendon. Axial images in CT-scan looked for muscle atrophy of latissimus dorsi in comparison with the controlateral. Electromyographic activity was measured during active flexion, abduction, adduction and rotations. Results. Twelve patients were satisfied. At the last follow-up, the average pain level according to a 100 mm visual analog scale was 31. The mean age and gender-matched Constant and Murley score improved from 34 to 60 % (p=0.003), forward elevation from 89° to 132° (p=0.006), abduction from 92° to 104°, external rotation from 12° to 24° (p=0.015). Mean abduction and external rotation strength were measured at 2.5 kg. Osteoarthritis progressed, and mean acromio-humeral distance has a significant decrease from 7.5 mm to 4.4 mm (p=0.003). Ultrasound examination showed twelve transferred tendons healed to the greater tuberosity. CT-scan showed a small atrophy of the transferred muscle, with a measurement of the cross-sectional area of the muscle belly at the inferior angle of the scapula at 1405 mm2, versus 1644 mm2 for the controlateral (p=0.06). Electromyographic analysis demonstrated a significant higher electric activity on the operative side during abduction and external rotation, and significant lower activity during adduction and internal rotation in comparison with the nonoperative side. Conclusions. Latissimus dorsi transfer allows for significant pain relief and function improvement in irreparable posterosuperior rotator cuff tears at young patients. Its electric activity increase in abduction and external rotation shows that the transferred muscle can integrate a new function and act like an active muscle transfer, in addition to an interposition or tenodesis effect. However we didn't find any depression of the humeral head or strength improvement


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1619 - 1626
1 Oct 2021
Bi M Zhou K Gan K Ding W Zhang T Ding S Li J

Aims

The aim of this study is to provide a detailed description of cases combining bridging patch repair with artificial ligament “internal brace” reinforcement to treat irreparable massive rotator cuff tears, and report the preliminary results.

Methods

This is a retrospective review of patients with irreparable massive rotator cuff tears undergoing fascia lata autograft bridging repair with artificial ligament “internal brace” reinforcement technique between January 2017 and May 2018. Inclusion criteria were: patients treated arthroscopically for an incompletely reparable massive rotator cuff tear (dimension > 5 cm or two tendons fully torn), stage 0 to 4 supraspinatus fatty degeneration on MRI according to the Goutallier grading system, and an intact or reparable infraspinatus and/or subscapularis tendon of radiological classification Hamada 0 to 4. The surgical technique comprised two components: first, superior capsular reconstruction using an artificial ligament as an “internal brace” protective device for a fascia lata patch. The second was fascia lata autograft bridging repair for the torn supraspinatus. In all, 26 patients with a mean age 63.4 years (SD 6.2) were included.


Bone & Joint 360
Vol. 10, Issue 6 | Pages 29 - 32
1 Dec 2021


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 83 - 90
1 Jan 2022
Batten TJ Gallacher S Evans JP Harding RJ Kitson J Smith CD Thomas WJ

Aims

The use and variety of stemless humeral components in anatomical total shoulder arthroplasty (TSA) have proliferated since their advent in 2004. Early outcomes are reassuring but independent mid-term results are scarce. This independent study reports a consecutive series of 143 Eclipse stemless shoulder prostheses with a minimum five-year (5 to 10) follow-up.

Methods

Outcomes of 143 procedures undertaken for all indications in 131 patients were reviewed, with subset analysis of those for osteoarthritis (OA) (n = 99). The primary outcome was the Oxford Shoulder Score (OSS) at a minimum of five years. Secondary outcomes were ranges of motion and radiological analysis of humeral radiolucency, rotator cuff failure, and glenoid loosening.


Bone & Joint 360
Vol. 10, Issue 3 | Pages 20 - 23
1 Jun 2021


Bone & Joint Open
Vol. 2, Issue 1 | Pages 58 - 65
22 Jan 2021
Karssiens TJ Gill JR Sunil Kumar KH Sjolin SU

Aims

The Mathys Affinis Short is the most frequently used stemless total shoulder prosthesis in the UK. The purpose of this prospective cohort study is to report the survivorship, clinical, and radiological outcomes of the first independent series of the Affinis Short prosthesis.

Methods

From January 2011 to January 2019, a total of 141 Affinis Short prostheses were implanted in 127 patients by a single surgeon. Mean age at time of surgery was 68 (44 to 89). Minimum one year and maximum eight year follow-up (mean 3.7 years) was analyzed using the Oxford Shoulder Score (OSS) at latest follow-up. Kaplan-Meier survivorship analysis was performed with implant revision as the endpoint. Most recently performed radiographs were reviewed for component radiolucent lines (RLLs) and proximal humeral migration.


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1600 - 1608
1 Dec 2018
Bouaicha S Ernstbrunner L Jud L Meyer DC Snedeker JG Bachmann E

Aims

In patients with a rotator cuff tear, tear pattern and tendon involvement are known risk factors for the development of pseudoparalysis of the shoulder. It remains unclear, however, why similar tears often have very different functional consequences. The present study hypothesizes that individual shoulder anatomy, specifically the moment arms (MAs) of the rotator cuff (RC) and the deltoid muscle, as well as their relative recruitment during shoulder abduction, plays a central role in pseudoparalysis.

Materials and Methods

Biomechanical and clinical analyses of the pseudoparalytic shoulder were conducted based on the ratio of the RC/deltoid MAs, which were used to define a novel anatomical descriptor called the Shoulder Abduction Moment (SAM) index. The SAM index is the ratio of the radii of two concentric spheres based on the centre of rotation of the joint. One sphere captures the humeral head (numerator) and the other the deltoid origin of the acromion (denominator). A computational rigid body simulation was used to establish the functional link between the SAM index and a potential predisposition for pseudoparalysis. A retrospective radiological validation study based on these measures was also undertaken using two cohorts with and without pseudoparalysis and massive RC tears.


Bone & Joint 360
Vol. 9, Issue 1 | Pages 32 - 35
1 Feb 2020


Bone & Joint 360
Vol. 7, Issue 5 | Pages 21 - 24
1 Oct 2018


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 224 - 228
1 Feb 2014
Simone JP Streubel PH Athwal GS Sperling JW Schleck CD Cofield RH

We assessed the clinical results, radiographic outcomes and complications of patients undergoing total shoulder replacement (TSR) for osteoarthritis with concurrent repair of a full-thickness rotator cuff tear. Between 1996 and 2010, 45 of 932 patients (4.8%) undergoing TSR for osteoarthritis underwent rotator cuff repair. The final study group comprised 33 patients with a mean follow-up of 4.7 years (3 months to 13 years). Tears were classified into small (10), medium (14), large (9) or massive (0). On a scale of 1 to 5, pain decreased from a mean of 4.7 to 1.7 (p = < 0.0001), the mean forward elevation improved from 99° to 139° (p = < 0.0001), and the mean external rotation improved from 20° (0° to 75°) to 49° (20° to 80°) (p = < 0.0001). The improvement in elevation was greater in those with a small tear (p = 0.03). Radiographic evidence of instability developed in six patients with medium or large tears, indicating lack of rotator cuff healing. In all, six glenoid components, including one with instability, were radiologically at risk of loosening. Complications were noted in five patients, all with medium or large tears; four of these had symptomatic instability and one sustained a late peri-prosthetic fracture. Four patients (12%) required further surgery, three with instability and one with a peri-prosthetic humeral fracture.

Consideration should be given to performing rotator cuff repair for stable shoulders during anatomical TSR, but reverse replacement should be considered for older, less active patients with larger tears.

Cite this article: Bone Joint J 2014;96-B:224–8.


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1520 - 1524
1 Nov 2014
van der Zwaal P Pijls BG Thomassen BJW Lindenburg R Nelissen RGHH van de Sande MAJ

The purpose of this study was to evaluate the natural history of rheumatoid disease of the shoulder over an eight-year period. Our hypothesis was that progression of the disease is associated with a decrease in function with time.

A total of 22 patients (44 shoulders; 17 women, 5 men, (mean age 63)) with rheumatoid arthritis were followed for eight years. All shoulders were assessed using the Constant score, anteroposterior radiographs (Larsen score, Upward-Migration-Index (UMI)) and ultrasound (US). At final follow-up, the Short Form-36, disabilities of the arm, shoulder and hand (DASH) Score, erythrocyte sedimentation rate and use of anti-rheumatic medication were determined.

The mean Constant score was 72 points (50 to 88) at baseline and 69 points (25 to 100) at final follow-up. Radiological evaluation showed progressive destruction of the peri-articular structures with time. This progression of joint and rotator cuff destruction was significantly associated with the Constant score. However, at baseline only the extent of rotator cuff disease and the UMI could predict the Constant score at final follow-up.

A plain anteroposterior radiograph of the shoulder is sufficient to assess any progression of rheumatoid disease and to predict functional outcome in the long term by using the UMI as an indicator of rotator cuff degeneration.

Cite this article: Bone Joint J 2014;96-B:1520–4.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 577 - 583
1 May 2012
Smith CD Guyver P Bunker TD

The outcome of an anatomical shoulder replacement depends on an intact rotator cuff. In 1981 Grammont designed a novel large-head reverse shoulder replacement for patients with cuff deficiency. Such has been the success of this replacement that it has led to a rapid expansion of the indications. We performed a systematic review of the literature to evaluate the functional outcome of each indication for the reverse shoulder replacement. Secondary outcome measures of range of movement, pain scores and complication rates are also presented.