Advertisement for orthosearch.org.uk
Results 1 - 19 of 19
Results per page:
The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 956 - 962
1 Jul 2014
Ahearn N Oppy A Halliday R Rowett-Harris J Morris SA Chesser TJ Livingstone JA

Unstable bicondylar tibial plateau fractures are rare and there is little guidance in the literature as to the best form of treatment. We examined the short- to medium-term outcome of this injury in a consecutive series of patients presenting to two trauma centres. Between December 2005 and May 2010, a total of 55 fractures in 54 patients were treated by fixation, 34 with peri-articular locking plates and 21 with limited access direct internal fixation in combination with circular external fixation using a Taylor Spatial Frame (TSF). At a minimum of one year post-operatively, patient-reported outcome measures including the WOMAC index and SF-36 scores showed functional deficits, although there was no significant difference between the two forms of treatment. Despite low outcome scores, patients were generally satisfied with the outcome. We achieved good clinical and radiological outcomes, with low rates of complication. In total, only three patients (5%) had collapse of the joint of > 4 mm, and metaphysis to diaphysis angulation of greater than 5º, and five patients (9%) with displacement of > 4 mm. All patients in our study went on to achieve full union. This study highlights the serious nature of this injury and generally poor patient-reported outcome measures following surgery, despite treatment by experienced surgeons using modern surgical techniques. Our findings suggest that treatment of complex bicondylar tibial plateau fractures with either a locking plate or a TSF gives similar clinical and radiological outcomes. Cite this article: Bone Joint J 2014;96-B:956–62


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 330 - 330
1 Sep 2012
London N Hayes D Waller C Smith J Williams R
Full Access

Introduction. Osteoarthritis (OA) represents a leading cause of disability and a growing burden on healthcare budgets. OA is particularly vexing for young, active patients who have failed less invasive therapies but are not yet candidates for arthroplasty. Often, patients suffering in this wide therapeutic gap face a debilitating spiral of disease progression, increasing pain, and decreasing activity until they become suitable arthroplasty patients. An implantable load absorber was evaluated for the treatment of medial knee OA in this patient population. Joint overload has been cited as a contributor to OA onset or progression. In response, the KineSpring® System (Moximed, Inc, USA) has been designed to reduce the load acting on the knee. The absorber is implanted in the subcutaneous tissue without violating the joint capsule, thus preserving the option of future arthroplasty. The implant is particularly useful for young, active patients, given the reversibility of the procedure and the preservation of normal flexibility and range of motion. Methods and Results. The KineSpring System was implanted in 55 patients, with the longest duration exceeding two years. The treated group had medial knee OA, included younger OA sufferers (range 31–68 years), with a mean BMI > 30kg/m2. Acute implant success, adverse events, and clinical outcomes using validated patient reported outcomes tools were recorded at baseline, post-op, 2 and 6 weeks, and 3, 6, 12 and 24 months post-op. All patients were successfully implanted with a mean procedure time of 76.4 min (range 54–153 minutes). Mean hospital length of stay was 1.7 days (range 1–3 days), and patients recovered rapidly, achieving full weight bearing within 1–2 wks and normal range of motion by 6 weeks. Most patients experienced pain relief and functional improvement with 85% (35/41) reporting none or mild pain on the WOMAC pain subscale and 90% (37/41) reporting functional impairment as none on mild on the WOMAC function subscale at the latest follow-up visit (mean 9.3 ± 3.5 months). Clinically meaningful and statistically significant pain reduction and functional improvement were noted with baseline WOMAC pain scores (0–100 scale) improving from 42.4 to 16.1 (p<0.001) and WOMAC function (0–100 scale) improving from 42.0 to 14.7 (p<0.001) at latest follow-up. Patients reported satisfaction with the implant and its appearance. Conclusions. The KineSpring System preserves natural knee anatomy and kinematics while providing pain reduction and resumption of high activity levels that have proven durable. This device, with these excellent results, fills a major gap in treatment options for young and active OA patients


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 542 - 542
1 Sep 2012
Wurster M Wurster M Pätzold R Gonschorek O Bühren V
Full Access

Introduction. Proximal tibial fractures frequently present in combination with other injuries which also have to be treated surgically. Recent publications do not consider isolated proximal tibial fracture (mono-injury) and combined injuries which include tibial fractures as two seperate medical entities. We therefore asessed the influence of additional injuries on treatment and outcome of the proximal tibial fractures. Methods. We admitted 84 patients which were consecutively treated in our department from 01.01.2007 to 31.12.2009. Only C1 to C3 fractures (x-ray, ct-scan), according to AO classification with subsequent open reduction and internal plate osteosynthesis were included. Additionally we looked for additional injuries cause by the accident, numbers of operations and strategie of operative treatement, traumaspecific vs. postsurgical complications and inpatient days. At the follow-up investigations one year post surgery, Lysholm- and WOMAC-Score as well as Tegner-Activity-Index were used. Results. The study includes 84 patients with 85 proximal tibia-C-fractures. Four fractures were classified as C1, 15 as C2 and 66 as C3. In 57 cases there was an isolated tibial fracture (I), 27 patients had combined injuries (C). The average age was 51,2 (I) and 55,4 (C), the gender ratio 36m/21f (I) versus 15m/12f (C). In 39 cases people had a recreational accident, 27 persons were involved in traffic accidents, 11 persons suffered from occupational injuries and 7 people got injured in their domestic environment. The average number of surgery the patients underwent was 2,32 (I) against 2,34 (C). Osteosynthesis was performed in 46% (I) vs. 50% (C) in one operation, subse-quently the other patients needed further surgical treatement. Autogen or allogen bonegrafts respectively artificial bone was used in 49,1% (I) vs. 42,8% (C). Traumaspecific problems such as compartment-syndrome or vessel-/nerve-injury occured in 31,6% (I) vs 25% (C), postsurgical complications appeared in 28% (I) vs 33,3% (C). The hospitalisation was 24 (I) vs 45 (C) days. Until the end of 2009, 54% of the patients could be included in our follow up, the average follow up was 15 months. The Lysholm-Score was 66,61 (I) vs 56,75 (C), the Tegner-Activity-Index was 4 (I) vs 1,41 (C), the WOMAC A was 90,2 (I) vs 68,6 (C), the WOMAC B was 77,6 (I) vs 65 (C) and the WOMAC C was 88,2 (I) vs. 72,9 (C). Conclusion. Concerning AO-Classification, complication rates and treatment data, both groups seem to be almost indentical in this study. In comparison to this we found a difference in the knee-joint-scores one year after trauma. Our figures show, that additional injuries do have a considerable influence in pain, stability and activity level of the knee/patient one year after trauma


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 352 - 352
1 Sep 2012
Nicodemo A Governale G Stucchi A Valente A Cuocolo C Massè A
Full Access

Introduction. Between 2002–2009 we operatively treated 193 acetabular fracture. Among these 44 both-columns fractures according to the classification of Letournel and Judet have been reviewed in order to evaluate the results. These fractures are rare, difficult to treat and often have poor clinical results. Patients and Methods. 44 cases of ORIF of displaced both columns fractures have been studied at a mean 37 months follow-up (range, 13 to 76 months) after the injury. 40 hips were operated with the ilioinguinal approach alone, 1 with Kocker Langenbeck and Smith petersen combined. The 3 remaining hips were operated with a double Kocher-Langenbeck and ilioinguinal approach. Every case was evalueted on X-rays according to Matta criteria and clinically with the Harris hip score and the WOMAC score. Results. The mean Harris hip score has been 85,8% (range 30%–100%) while the mean WOMAC score has been 88,3 points (range 39,1–100). The main complications were 4 early post-traumatic arthritis operated by hip replacement. One patient instead developed a gastric carcinoma. Discussion. The rate of anatomical reduction decreased with the complexity of the fracture, the age, and the interval between the injury and the reduction. The clinical result was adversely affected by associated injuries of the femoral head, an older age of the patient. It was positively affected by an anatomical reduction and postoperative congruity between the femoral head and the acetabular roof. Conclusions. These findings indicate that in many patients who have a complex acetabular fracture the hip joint can be preserved and post-traumatic osteoarthritis can be avoided if an anatomical reduction is achieved. Both column acetabular fractures can be reduced with a combined surgical approaches or with ilioinguinal alone. We used the ilioinguinal approach alone in 91% of cases reaching good results, even comparing Letournel and Matta's results. Surgeon experience and a long learning curve can help in decision making and in obtaining an anatomical reduction with a low rate of post-operative complications


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 144 - 144
1 Sep 2012
Bruni D Raspugli G Iacono F Lo Presti M Zaffagnini S Marcacci M
Full Access

Background. The reported outcomes of unicompartmental knee replacement (UKR) for spontaneous osteonecrosis of the knee (SPONK) often derive from small series with an average followup of 5 years, enabling to generate meaningful conclusions. Therefore, we determined the long-term functional results and the 10-years survivorship of the implant in all patients with advanced SPONK of the medial tibio-femoral compartment treated with a unicompartmental knee arthroplasty at our institute. Methods. We retrospectively evaluated 84 consecutive patients with late stage SPONK. All patients received a pre-operative MRI to confirm the diagnosis, to exclude any metaphyseal involvement and to assess the absence of significative degenerative changes in the lateral and PF compartment. Mean age at surgery was 66 years and mean body mass index (BMI) was 28.9. In all cases, SPONK involved the medial compartment; in 77 cases the medial femoral condyle (MFC) was involved, while in 7 cases the pathology site was the medial tibial plateau (MTP). Radiological evaluation was conducted by 3 different radiologists and clinical evaluation according to KSS and WOMAC score was performed by 3 fellows from outside institutions, with no previous clinical contact with the patients, at a mean followup of 98 months. Results. We found a significant improvement in VAS score for residual pain self-assessment and maximum knee flexion (p<0.0001). The 10-year Kaplan-Meier survivorship with revision for any reason as endpoint was 89%. Mean results at final observation point for global KSS and WOMAC score were 87.1 (range 45–100; standard deviation 13.8) and 12 (range 0–44; standard deviation 10.3), respectively. No patient had significant radiographic signs of osteoarthritis progression in the lateral compartment or in the patello-femoral compartment at final evaluation. Conclusions. Our findings suggest that medial UKR performed for late stage SPONK of the medial tibio-femoral compartment in selected patients provides satisfactory long term clinical and radiographical results, with a 10-years Kaplan-Meier survivorship of the implant of 89%


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 261 - 261
1 Sep 2012
Espandar R Mortazavi SMJ Kaseb MH Haghpanah B Yazdanian S
Full Access

Background. Medial opening-wedge high tibial osteotomy is one of the common surgical procedures in treatment of knee deformities. Many methods have been proposed to fill the medial side osseous gap. The results of using allograft as void filler compared to iliac crest autograft has not been subject to a randomized clinical trial. The purpose of this study was to examine the results of medial opening-wedge high tibial osteotomy using iliac crest allograft as compared to iliac crest autograft. Materials & Methods. Forty-six patients with genovarum deformity were enrolled based on specific inclusion and exclusion criteria and were randomly assigned into two groups. Medial opening-wedge high tibial osteotomy was done using iliac crest allograft (23 patients) or autograft (23 patients) and the osteotomy site was internally fixed using proximal tibial T-plate. All patients were followed-up to 12 months after surgery. Anatomical indices of proximal tibia, complications of treatment, and functional outcome (using WOMAC osteoarthritis index) were assessed for both groups. Results. The amount of correction (degrees), recurrence of the deformity and loss of correction and time to clinical or radiologic union were similar in both groups with no statistically significant difference. Duration of operation was significantly less in allograft group (66.6±3.6 versus 52.9±5.3 minutes, p<0.001). Incidence of surgical site infection did not significantly differ in two groups. No nonunion or delayed union was encountered in either group. Some patients reported more intense postoperative pain in iliac graft harvest site than tibial osteotomy site. Patients in both groups had statistically significant improvement in WOMAC index postoperatively (with no statistically significant difference between groups). Conclusions. According to the results of this study, iliac crest allograft may be safely used in medial opening-wedge high tibial osteotomy with comparable efficacy to iliac crest autograft in patients who do not accept the morbidity of autograft harvest


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 490 - 490
1 Sep 2012
Confalonieri N Manzotti A
Full Access

Introduction. The authors performed a short term prospective study of unicompartmental knee replacement (UKR) associated to patella-femoral arthroplasty (PFA) for the treatment of bicompartmental symptomatic knee arthritis. At the latest follow-up all the implants were matched to a similar computer assisted Total Knee Replacements (CAS-TKR) group implanted for the same indications. Hypothesis of the study was that this bicompartimental implants could achieve comparable outcomes to TKR with a more conservative surgery and a higher joint function. Materials and Methods. 19 cases of anteriomedial (12) or anterolateral (7) arthritis in 19 stable knees were prospectively involved in the study. All the knees underwent to a selective reconstruction using simultaneously both UKR and PFR using the same surgical technique. All bicompartmental implants were performed by the same surgeon. Surgical time, hospital staying and all intra and post operative complications were registered. At a minimum follow-up of 20 months, every single case was marched to a similar case where had been implanted a computer assisted cruciate retaining TKR. Criteria of matching were: sex, age, pre-operative range of motion and arthritis grade. In both the groups all the cases were assessed clinically using WOMAC, KKS and GIUM scores. All the knees were radiologically investigated using the same radiological protocol. Results. Intra operatively we did not registered any complication. No revision in both groups. The mean surgical time was 86 minutes (range: 78–121) in UKR+PFR group and 81 minutes (range: 71–112) in CAS-TKR group. There were no statistical significant differences in the hospital stay. No statistically significant difference was seen for the Knee Society, Functional and GIUM scores between the 2 groups. Statistically significant better WOMAC Function/Stiffness indexes were registered for the UKR+PFR group. CAS-TKR implants achieved a statistically better aligned mechanical axes. Conclusions. The results of this prospective short term prospective study suggest that UKR+PFR implant is a viable option for bicompartmental anteromedial arthritis at least as well as TKR but maintaining an higher level of function


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 15 - 15
1 Sep 2012
George A Hassaballa M Artz N Alhammali T Robinson J Porteus A Murray J
Full Access

Introduction. The legion knee revision system was designed as a follow and improvement to the Genesis II knee system- allowing for a surgeon directed femoral rotation as opposed to the in-built femoral rotation in the previous system. This is a prospective review of consecutive patients who underwent knee revision surgery using the legion knee system. Methods. Clinical and functional assessments were carried out preoperatively, one year and 2 years post op. Radiographic evaluation was done at 1 and 2years follow up. Standard knee scoring systems (American Knee Scores-AKS, and Oxford score were used for the clinical and functional evaluation of these patients. The WOMAC score was also used to assess for pain, stiffness and social function in these patients. The radiographic assessment included review of standing AP, lateral and skyline views. Figgie's method was used to measure the joint line reproduction. A difference of 5 mm (pre = op/post-op) was deemed satisfactory. Results. Seventy-five consecutive patients underwent revision knee system- 38 male: 34 females with a mean age of 71.2 (50–87 yrs.). Mean BMI-26.03, (Range 11–50). We had a 2-year follow up for 32 patients Surgery was carried out at a single centre and performed by members of the Bristol knee group. Indications for surgery in these patients- were aseptic loosening (38), instability (15), pain and stiffness (7), polyarthropathy (2), ligament laxity (3), peri-prosthetic fractures (3), and impingement (4). The mean American Knee scores, and WOMAC scores at, 1 year and 2 years follow up showed significant improvements in pain and function. It was also noted that the mean oxford knee score improved from 14/48 pre-operatively to 34/48 at 2yrs. Radiographic assessment showed a mean AP coronal femoral angle of 95.3 degrees (range 89.6–99.9 degrees), coronal tibial angle of 90.1 degrees (Range 88–92 degrees). The mean sagittal femoral and tibial angles were 88.4 and 90.4 degrees respectively. Mean Kappa value for the inter observer reliability for the radiographic assessment was 0.50 showing agreement, with standard error measurement of 1.2. The joint line was reproduced in all cases. Discussion. The short-term results with the Legion Knee revision system showed significant improvement in functional and pain scores in these patients irrespective of their indications for revision surgery. Overall the legion system has showed good outcome scores that match or beat published series on revisions. It also showed a good ability to restore joint line. Ongoing work needed to refine indications and realistic outcomes for different diagnoses


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 55 - 55
1 Sep 2012
Martin A Cip J Mayr E Benesch T Waibel R Von Strempel A Widemschek M
Full Access

Background. Computer-assisted navigation systems for total knee arthroplasty (TKA) were introduced to improve implantation accuracy and to optimize ligament balancing. Several comparative studies in the literature confirmed an effect on the component position and other studies could not confirm these results. For ligament balancing most studies found no significant influence on the clinical outcome using a navigation system for TKA. In the literature there were no reports of mid-term results after navigated TKA. With our study we wanted to show if the use of a navigation system for TKA will have an influence on the component's position and on the clinical results at 5-year follow up. Methods. We enrolled 200 patients in a prospective randomized study with a minimum follow up of 5 years. 100 TKA were operated on without using a navigation system (Group A) and 100 surgeries (Group B) were done with computer assistance. Radiological investigation by standard radiographs including a long-leg X-ray was performed with a follow up rate in Group A of 86.2% versus 80.2% in Group B. We measured the mechanical axis of the leg, lateral distal femoral angel (LDFA), medial proximal tibial angle (MPTA), tibial slope and the alpha-angle of the patella. Clinical investigation was performed with a follow up rate in Group A of 85.7% versus 79.8% in Group B including the parameters for the range of motion (ROM), ligament balancing, anterior drawer test, feeling of instability, anterior knee pain, effusion, WOMAC Score, Insall Score and HSS Knee Score. Results. In both groups there was no aseptic loosening or difference in TKA survival rate (Group A 95.4% versus Group B 98.85% 5-year survival rate, p = 0.368). With the navigation technique the mechanical axis of the limb in the frontal plane was improved (p = 0.015; Group B: 1.67 ° ± 1.6° versus 2,44 ° ± 2.2 ° in Group A). 90% of the Group B and 81% of the Group A were within 3 ° varus/valgus deformity of the mechanical axis of the limb (p = 0.157). The accuracy of tibial slope was higher in the Group B (p = 0.001). More patients of the Group B (95% versus 79%) were within a deviation of 3 °, −7 ° tibial slope (p = 0.007). The mean deviation of 90 ° LDFA was higher (p = 0.034) in the Group A (1.89 ° versus 1.36 ° in Group B). Mean deviation of 90 ° MPTA, mean MPTA, mean LDFA and patella alpha angle were similar in both groups (p 0.253). There was no difference in ROM, ligament balancing, anterior drawer test, anterior knee pain or feeling of instability (p 0.058). Insall Knee Score total (181 Group A/191 Group B) and HSS Knee Score total (91 Group A/93 Group B) was higher with the navigated procedure in Group B (p 0.026). WOMAC total and HSS grades were similar in both groups (p 0.070). Conclusions. The accuracy of the mechanical axis of the limb and the tibial slope was higher with the navigated procedure. TKA survival rate and clinical outcomes were similar in both groups at 5-year follow up


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1735 - 1742
1 Dec 2020
Navarre P Gabbe BJ Griffin XL Russ MK Bucknill AT Edwards E Esser MP

Aims

Acetabular fractures in older adults lead to a high risk of mortality and morbidity. However, only limited data have been published documenting functional outcomes in such patients. The aims of this study were to describe outcomes in patients aged 60 years and older with operatively managed acetabular fractures, and to establish predictors of conversion to total hip arthroplasty (THA).

Methods

We conducted a retrospective, registry-based study of 80 patients aged 60 years and older with acetabular fractures treated surgically at The Alfred and Royal Melbourne Hospital. We reviewed charts and radiological investigations and performed patient interviews/examinations and functional outcome scoring. Data were provided by the Victorian Orthopaedic Trauma Outcomes Registry (VOTOR). Survival analysis was used to describe conversion to THA in the group of patients who initially underwent open reduction and internal fixation (ORIF). Multivariate regression analyses were performed to identify factors associated with conversion to THA.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 40 - 40
1 Apr 2013
Paetzold R Spiegl U Wurster M Augat P Gutsfeld P Gonschorek O Buehren V
Full Access

Alpine ski sports changed rapidly in the last decade. Complex fractures of the proximal tibia, typically seen in high energy trauma, has been seen more frequently and more often related to alpine skiing. The aim of our study was to identify reasons for proximal tibia fracture in alpine skiing and observe the outcome. All patients with proximal tibia fractures related to alpine skiing, which were treated in our two trauma centers were included. The patients received a questionnaire at the emergency department, dealing with accident details and the skiing habits. The fractures were classified according to the AO fracture classification scheme. The follow up was performed at least one year after trauma with the Lysholm, the Tegner activity, as well as the WOMAC VAS Score. Between 2007 and 2010 a total of 188 patients with proximal tibia fractures caused by alpine skiing were treated. 43 patients had a type A, 96 patients a type B and 49 a type C injury. The incidence was increasing over the period continuously. The main trauma mechanism was an accident without a third party involvement with an increased rotational and axial compression impact. All outcome scores were related to fracture severity with significant worse results for the type C fractures. In conclusion, proximal tibia fractures are an increasing and serious injury during alpine skiing. Further technical progress in skiing material should focus on these knee injuries in future


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 264 - 264
1 Sep 2012
Malhi A Bohm E Hedden D Burnell C Turgeon T
Full Access

Introduction. The purpose of this study was to compare the clinical outcomes and complications following bilateral simultaneous total knee arthroplasty in high body mass index (BMI) patients(>30kg/m. 2. ) to those of patients with a BMI<30 kg/m. 2. . Materials and Methods. Using data from an academic arthroplasty database and review of clinic charts we obtained health related quality of life (SF-12), and disease specific functional outcome scores (WOMAC or Oxford Knee Score). We also assessed length of hospital stay, ASA grade and transfusion requirements. Sixty six patients had a BMI<30 and 151 patients had a BMI>30. Results. Most cases were performed under combined spinal/epidural anaesthesia. We could find no appreciable difference in length of hospital stay, ASA grade or transfusion requirements between the two subgroups. Furthermore, were unable to detect any significant differences in post operative SF-12, WOMAC or Oxford Knee scores. There appeared to be no significant increase in the rate of medical complications between the two subgroups, and while there may have been a slight trend towards higher procedure related complications in the high BMI group, this did not reach statistical significance. Conclusions. In our study increased BMI appears to have no negative effects as regards functional outcomes, hospital stay or transfusion requirements for bilateral sequential knee arthroplasty. However there may be an increase in procedural/device related complications which could result in increased revision rates in these patients


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 344 - 344
1 Sep 2012
Torres A Fairen M Mazon A Asensio A Meroño A Blanco A Ballester J
Full Access

Between July 2000 and December 2002, 263 consecutive patients across 5 surgical centers underwent to a revision surgery of a failed acetabular component in which TM acetabular components were used. There were 150 women and 113 men with a mean age of 69.5 years. The indication for acetabular revision was aseptic loosening in 186 cases (70.7%). Clinical evaluations were performed using the Harris hip score, the WOMAC and UCLA activity scale. Implant and screw position, polyethylene wear, radiolucent lines, gaps, and osteolysis were assessed. Preoperatively, acetabular bone deficiency was categorized using the classification of Paprosky et al. Statistical analysis was performed using nonparametric correlations. Standard life table was constructed, and the survival rate was calculated by means of Kaplan-Meier method. The overall mean follow-up was 73.6 months (range, 60–84 months), and no patient was lost to follow-up. The preoperative HHS rating improved from a mean of 43.6 ± 11.4 before revision, to a mean of 82.1 ± 10.7. None of the patients was re-revised for loosening. The cumulative prosthesis survival was 99.2% at 5 years. There was no correlation found between the various degrees of acetabular bony defect and the magnitude of clinical results (independent of pre-revision Paprosky grade). The use of component augments allowed us to minimize the volume of morsellized allograft used for defect repair. TM acetabular component demonstrates promising midterm results similar to those reported by other authors


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 458 - 458
1 Sep 2012
Raman R Shaw C Johnson G Sharma H Day N Dutta A
Full Access

Introduction. Viscosupplementation is used widely to provide symptomatic relief to patients with knee OA. This study aimed to compare the efficacy and safety of the standard (3×2ml) and single (1×6ml) dosing regimens of hylan G-F 20. Methods. Prospective, randomized, blinded (reviewers), comparative independent study. Inclusion criteria was OA knee pain e 60mm on a 100mm VAS; no prior intra articular (IA) injection. Patients were randomised to recieve 1 × 6mL or 3 × 2mL hylan G-F 20. Follow-up at 1, 6, 12, 26 and 52 weeks. Analgesics prohibited for 24 hours prior to follow-up assessments and NSAID_s for 26 wks. All adverse events (AE) were recorded. Primary outcome measure: Target knee pain (VAS) at 26 weeks. Secondary outcome measures included WOMAC, Oxford knee score, SF12. Results. 412 patients were randomized (1 × 6mL N=194, 3 × 2 mL N=218). There were no significant differences in age, gender or grade of OA. Injection and/or treatment-related AE (all mild/moderate) were reported in 10.5% (3 × 2 mL) and 9.1% (1 × 6 mL) of patients Significant pain reduction was observed in both groups at 26 weeks (3 × 2 mL: 50% (mean) decrease, 1 × 6mL: 45%). There were no significant differences between groups for any of the primary or secondary outcome measures at 26 weeks. Discussion and Conclusion. Single dose of 6 mL hylan G-F 20 offer comparable safety and efficacy to 3 × 2 mL at 26 weeks. It provides both the patients and physicians a choice with the potential additional benefits of reduced operational costs


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 39 - 39
1 Sep 2012
Lee MC Lee SM Seong SC Lee S Jang J Lee JK Shim SH
Full Access

Summary. UC TKA showed similar anteroposterior translation and more femoral external rotation of earlier onset when compared to PS TKA. Introduction. Recently highly conforming ultracongruent TKA has been reintroduced with improved wear characteristics and lower complications. The purpose of the study was to assess kinematics and clinical outcome of posterior stabilized and ultracongruent rotating-platform mobile bearing TKA. Methods. Ninety patients with primary osteoarthritis of the knee were randomized to undergo computer assisted TKA with PS(n = 45) or UC(n = 45) prostheses and were followed up for a minimum 2 years. The passive kinematic evaluation was performed before and after implantation with a navigation system. Three parameters of tibiofemoral relationship (anterior/posterior translation, varus/valgus alignment and rotation) were recorded from 0° to 120° of flexion. The patients were clinically and radiographically evaluated at final follow-up. Results. Paradoxical anterior translation of the femur was observed from 0° to 70° of flexion in PS(8.7mm) and 0° to 85° in UC knees(10.4mm, p = 0.064). The distance of femoral roll-back was 6.7mm and 5.5mm, but never reached the starting point. Paradoxical internal rotation of the femur was found from 0° to 62° of flexion in PS(9.9°) and 0° to 47° in UC knees(5.6°, p = 0.002). UC knees showed more external rotation of the femur during flexion from 0° to 120°(5.7:11.0, p = 0.048). There was no significant difference in the maximal flexion(123.3°:125.5°, p = 0.366), AKS knee scores(95.9:92.0, p = 0.101), AKS function scores(86.2:82.9, p = 0.435) and WOMAC index scores(13.4:15.9, p = 0.268). There was no progressive radiolucent line or loosening in all knees. Discussion and Conclusion. UC TKA showed similar anteroposterior translation and more femoral external rotation of earlier onset when compared to PS TKA. There was no difference in clinical outcome between two designs. UC TKA showed comparable kinematic and clinical results to PS TKA


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 361 - 369
1 Mar 2018
Sprague S Bhandari M Heetveld MJ Liew S Scott T Bzovsky S Heels-Ansdell D Zhou Q Swiontkowski M Schemitsch EH

Aims

The primary aim of this prognostic study was to identify baseline factors associated with physical health-related quality of life (HRQL) in patients after a femoral neck fracture. The secondary aims were to identify baseline factors associated with mental HRQL, hip function, and health utility.

Patients and Methods

Patients who were enrolled in the Fixation using Alternative Implants for the Treatment of Hip Fractures (FAITH) trial completed the 12-item Short Form Health Survey (SF-12), Western Ontario and McMaster Universities Arthritis Index, and EuroQol 5-Dimension at regular intervals for 24 months. We conducted multilevel mixed models to identify factors potentially associated with HRQL.


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 690 - 695
1 May 2016
Dodd A Osterhoff G Guy P Lefaivre KA

We performed a systematic review of the literature pertaining to the functional outcomes of the surgical management of acetabular fractures. A total of 69 articles met our inclusion criteria, revealing that eight generic outcome instruments were used, along with five specific instruments. The majority of studies reported outcomes using a version of the d’Aubigne and Postel score, which has not been validated for use in acetabular fracture. Few validated outcome measures were reported. No psychometric testing of outcome instruments was performed. The current assessment of outcomes in surgery for acetabular fractures lacks scientific rigour, and does not give reliable outcome data for either scientific comparison or patient counselling.

Take home message: The use of non-validated functional outcome measures is a major limitation of the current literature pertaining to surgical management of acetabular fractures; future studies should use validated outcome measures to ensure the legitimacy of the reported results.

Cite this article: Bone Joint J 2016;98-B:690–5.


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 95 - 100
1 Jan 2013
Chémaly O Hebert-Davies J Rouleau DM Benoit B Laflamme GY

Early total hip replacement (THR) for acetabular fractures offers accelerated rehabilitation, but a high risk of heterotopic ossification (HO) has been reported. The purpose of this study was to evaluate the incidence of HO, its associated risk factors and functional impact. A total of 40 patients with acetabular fractures treated with a THR weres retrospectively reviewed. The incidence and severity of HO were evaluated using the modified Brooker classification, and the functional outcome assessed. The overall incidence of HO was 38% (n = 15), with nine severe grade III cases. Patients who underwent surgery early after injury had a fourfold increased chance of developing HO. The mean blood loss and operating time were more than twice that of those whose surgery was delayed (p = 0.002 and p < 0.001, respectively). In those undergoing early THR, the incidence of grade III HO was eight times higher than in those in whom THR was delayed (p = 0.01). Only three of the seven patients with severe HO showed good or excellent Harris hip scores compared with eight of nine with class 0, I or II HO (p = 0.049). Associated musculoskeletal injuries, high-energy trauma and head injuries were associated with the development of grade III HO.

The incidence of HO was significantly higher in patients with a displaced acetabular fracture undergoing THR early compared with those undergoing THR later and this had an adverse effect on the functional outcome.

Cite this article: Bone Joint J 2013;95-B:95–100.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1347 - 1350
1 Oct 2006
Karn NK Singh GK Kumar P Shrestha B Singh MP Gowda MJ

We conducted a randomised controlled trial to compare external fixation of trochanteric fractures of the femur with the more costly option of the sliding hip screw. Patients in both groups were matched for age (mean 67 years, 50 to 100) and gender. We excluded all pathological fractures, patients presenting at more than one week, fractures with subtrochanteric extension or reverse obliquity, multiple fractures or any bone and joint disease interfering with rehabilitation. The interval between injury and operation, the duration of surgery, the amount of blood loss, the length of hospital stay and the cost of treatment were all significantly higher in the sliding hip screw group (p < 0.05). The time to union, range of movement, mean Harris hip scores and Western Ontario and McMaster University knee scores were comparable at six months. The number of patients showing shortening or malrotation was too small to show a significant difference between the groups. Pin-track infection occurred in 18 patients (60%) treated with external fixation, whereas there was a single case of wound infection (3.3%) in the sliding hip screw group.