Advertisement for orthosearch.org.uk
Results 1 - 9 of 9
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 890 - 892
1 Sep 1999
Rickman M Saleh M Gaines PA Eyres K

Osteotomies are commonly carried out in orthopaedic surgery, particularly in limb reconstruction. Complications are uncommon provided that sufficient care is taken and a sound technique used. We describe three cases of formation of false aneurysm after osteotomy, with acute, delayed and asymptomatic onset. The diagnosis was supported by ultrasound investigation, and confirmed by angiography. Embolisation with coils was a successful method of treatment. We recommend a safe method of osteotomy with good bone exposure and adequate soft-tissue protection.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 5 - 5
1 Feb 2017
Habashy A Sumarriva G Chimento G
Full Access

Background. Intravenous and topical tranexamic acid (TXA) has become increasingly popular in total joint arthroplasty to decrease perioperative blood loss. In direct comparison, the outcomes and risks of either modality have been found to be equivalent. In addition, current literature has also demonstrated that topical TXA is safe and effective in the healthy population. To our knowledge, there is a scarcity of studies demonstrating the safety of topical TXA in high risk patient populations undergoing total joint arthroplasty or revision joint arthroplasty. The purpose of this study is to determine the safety of topical TXA in patients undergoing total or revision arthroplasty that are also on chronic anticoagulant or anti-platelet therapy. Methods. We performeded a retrospective review of patients undergoing primary and revision total hip or knee arthroplasties that received topical TXA (3g/100mL NS) from November 2012 to March 2015. All patients, regardless of co-morbidities, were included in the study population. Patients were divided into 3 groups:. Group 1: Patients without any antiplatelet or anticoagulant therapy within 90 days of surgery. Group 2: Patients receiving antiplatelet therapy (Aspirin and/or Plavix) within 90 days of surgery. Group 3: Patients receiving anti-coagulant therapy within 90 days of surgery (low molecular weight heparin, unfractionated heparin, warfarin, dabigatran, rivaroxaban, apixaban). Chart review analyzing ICD-9 and ICD-10 coding was then utilized to establish any peri-operative complications within the 30 day post-operative period in all groups. Complications amongst the groups were evaluated via chi-squared testing as well as multivariate linear regression. Review of current literature and CMS protocols were used to establish reportable peri-operative complications. Wound infections, thromboembolic events and vascular complications such as myocardial infarction, pulmonary embolism, deep venous thrombosis, stroke, aortic dissection were included. Results. During the study period, a total 1471 total joint arthroplasties were performed on 1324 patients (88.7% knee arthroplasty, 11.3% hip arthroplasty). Group 1 included 1033 patients who were not on any prior anti-platelet or anticoagulant therapy. Group 2 included 254 patients receiving chronic antiplatelet therapy 90 days prior to surgery. Group 3 included 184 patients receiving chronic anticoagulant therapy 90 days prior to surgery. No statistically significant differences were found between the groups for any of the included peri-operative complications. The most common complication occurring amongst all the groups was superficial wound infection, which occurred in a total of 60 (4.1%) patients in contrast to 18 (1.2%) patients who sustained an acute deep peri-prosthetic infection. Twenty (1.4%) patients sustained an ultrasound proven deep vein thrombosis, with the highest prevalence occurring in those patients receiving no anticoagulation prior to surgery (15/20, 75%), however this was not statistically significant following linear regression analysis. Conclusions. To our knowledge, this is the first study that demonstrates that topical tranexamic acid is safe to use in so-called high risk patients who are being treated prior to surgery with anti-platelet or anti-coagulation therapy


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 110 - 110
1 Jan 2016
Oshima Y Fetto J
Full Access

Introduction. Femoral neck fracture is a common injury in elderly patients. To restore the activity with an acceptable morbidity and to decrease of mortality, surgical procedures are thought to be superior to conservative treatments. Osteosynthesis with internal fixation for nondisplaced type, and hemiarthroplasty or total hip replacement (hip arthroplasties) for displaced type are commonly performed. Cemented arthroplasty has been preferred over non-cemented arthroplasty because of less postoperative pain, better mobility and excellent initial fixation of the implant, especially for osteoporotic and stove-pipe bones. However, pressurizing bone cement may cause cardiorespiratory and vascular complications, and occasionally death, which has been termed as “bone cement implantation syndrome”. To avoid the occurrence of this syndrome, non-cemented implants have been developed. However, most implants with the press fit concepts and flat wedge taper designs have a risk of intraoperative and early postoperative periprosthetic fracture. Recently, we have employed a non-cemented femoral component, which has a lateral expansion to the proximal body as compared to a conventional hip stem. Because of this shape, which is called a “lateral flare”, this stem provides a physiological loading on both the medial and lateral endosteal surfaces of the femur. This is in contrast to conventional hip stem which prioritizes loading on the medial and metaphyseal /dyaphyseal surfaces of the femur. Moreover, the cross section of this stem is trapezoid with the flat posterior surface. This shape provides the stem with rotational stability along the long axis of the femur, and maximizes loading transfer to the posterior aspect of the proximal femur. These mechanical features avoid the need for aggressive impaction of the stem at the time of insertion. It is necessary to only tap gently to achieve the secure initial implant fixation by a “rest fit”. Thus, this technique reduces the risk of fracture. Patients and methods. We employed this technique using a non-cemented lateral flare design device for displaced femoral neck fractures since 1996. Surgical procedures were performed with posterior approach under the spinal or epidural anesthesia. Full weight bearing ambulation with a walker was allowed on post-op day one. Results and discussion. Since that time, we have had no femoral fracture, no dislocation of the hip, nor severe complications intraoperatively and post operatively. There has been no evidence of radiographic aseptic loosening or axial migration of the stems during this time period. Conclusions. “Rest fit” surgical technique avoids complications associated with cemented and traditional non-cemented arthroplasties for displaced femoral neck fractures. It however requires specific geometric features to be included the designs of the femoral component to assure secure initiate fixation at the time of arthroplasty. Therefore, this lateral flare implants are effective for the treatment of the displaced type of femoral neck fracture


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_7 | Pages 12 - 12
1 Feb 2013
Tawari G Royston S Dennison M
Full Access

Introduction. Corrective femoral osteotomy in adults, as a closed procedure with the use of an intramedullary saw, is an elegant, minimally invasive technique for the correction of lower limb length inequalities or problems of torsion. Stabilisation following the osteotomy was achieved with a cephalo-medullary nail. We report the indications, results and complications following use of this technique. Aim. The aim of the study was to review consecutive patients who underwent closed femoral rotational or shortening osteotomy using an intramedullary saw over a ten-year period. Material & Methods. Forty femoral rotational and/or shortening osteotomies using an intramedullary saw were performed on thirty-six patients, between January 2001 and June 2011. The main indications were post-traumatic leg length discrepancies and congenital rotational abnormalities. Clinical & radiological follow up mean was 16.3 months. Results. Twenty one osteotomies were performed for femoral shortening with the mean correction of 3.5 cm. Nineteen osteotomies were performed for correction of torsion; there was a mean correction of 28.64 degrees with Internal rotation and 35 degrees with external rotation osteotomies. Fourteen patients required removal of locking screws. There were two patients with heterotrophic ossification, two patients with wound infection (one deep infection). One patient had a materiovigilance incidence and one patient had vascular complication requiring embolisation. The subjective results showed 37 osteotomies were satisfied with their operation, functional recovery and aesthetic appearance of the scars. Conclusion. Closed osteotomy of femur for correction of LLD and torsion using an intramedullary saw represents a reliable and effective procedure. Despite the complications, the original goal of the surgery was achieved in 37 of the 40 limbs treated. Patient satisfaction was achieved in 92.5 % of 40 osteotomies


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 244 - 244
1 Sep 2012
Jones M Mahmud T Narvani A Hamid I Lewis J Williams A
Full Access

Data was collected on 139 eligible patients a minimum of 18 months post surgery who had had 2 or more ligaments reconstructed. 63 patients were available for clinical follow up. It is the largest single surgeon series studied. 27% of injuries were high energy traffic accidents. 73% were low energy, mainly sports related. 63% of patients were delayed referrals to our unit. Of these nearly 48% had already undergone knee surgery, often more than 6 months post injury. 17% of all cases presented with failed ligament reconstructions. Of those patients followed up 19% were operated upon within 3 weeks of injury, 56% were delayed reconstructions with a mean time to surgery of 21 months and 25% were revision reconstructions. Time to follow up ranged from 18 months to 10 years. The median KOS ADL, KOS Sports Activity and Lysholm scores for uni-cruciate surgery were all better than those for bi-cruciate surgery. All results were better for acute rather than chronic cases, which in turn were better than those for revision cases. The Tegner score showed that only acute uni-cruciate reconstructions returned to their pre-injury level. TELOS stress radiographs demonstrated a mean post drawer of 5.9 mm side-to-side difference after reconstructions involving the PCL. IKDC grades showed 6% of knees were normal and 57% were nearly normal. 37% required further surgery, mainly to increase movement or for hardware removal. There was 1 deep infection and 2 cases of thrombosis. There were no vascular complications but 2 had transient nerve injuries. Multi-ligament surgery can produce good functional outcomes but the knee is never normal. There is an increased risk of PCL laxity post op. Early referral to a specialist unit is suggested as delayed referral to a specialist unit potentially subjects the patient to unnecessary surgery and may affect outcome


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 196 - 196
1 May 2012
Bucknill A Yew J Clifford J de Steiger R
Full Access

Percutaneous cannulated screw placement (PCSP) is a common method of fixation. In pelvic trauma neurovascular structures are in close proximity to the screw path. Pre-operative planning is needed to prevent injury. This study aims to the safety margin and accuracy of screw placement with computer navigation (CAS). A control had no pathology in the pelvis but CT scans were performed for suspected trauma. The treated group had pelvic and acetabular fractures and were treated with CAS PCSP at our institution. Using a new technique involving CT 3D modelling of the whole (3D) safe corridor, the dimensions of the Posterior elements (PE) of the pelvic ring and the anterior column of the acetabulum (AC) were measured in the control group. The accuracy of screw placement (deviation between the actual screw and planned screw) was measured in treated patient using a screenshot method and post-operative CTs. There were 22 control patients and 30 treated patients (40 screws). The mean ± (standard deviation, SD) minimum measurement of the safe corridor at the PE was 15.6 ± 2.3 mm (range 11.6 mm to 20.2 mm) and at the AC was 5.9 ±1.6 mm (range 3.0 mm to 10.0 mm). The mean ± (SD) accuracy of screw placement was 6.1 ± 5.3 mm and ranged from a displacement of 1.3 mm to 16.1 mm. There was a notable correlation between Body Mass Index, duration of surgery and inaccuracy of screw placement in some patients. The largest inaccuracy of screw placement was due to reduction of the fracture during screw insertion, causing movement of the bone fragments relative to the array and therefore also the computerised screw plan. There were no screw breakages, non-unions, neurological or vascular complications. CAS PCSP is a safe and accurate technique. However, the safe corridor is variable and often very narrow. We recommend that the dimensions of the safe corridor be assessed pre-operatively in every patient using 3D modelling to determine the number and size of screw that can be safely placed


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 167 - 167
1 May 2012
Chazono M Tanaka T Soshi S Inoue T Kida Y Nakamura Y Shinohara A Marumo K
Full Access

The use of cervical pedicle screws as anchors in posterior reconstruction surgery has not been widely accepted due to the neurological or vascular injury. We thus sought to investigate the accuracy of free-handed pedicle screw placement in the cervical and upper thoracic spine at the early stage of clinical application. Eight patients (five males and three females) were included in this study. Mean age was 63 years (31 to 78 years). There were three patients with rheumatoid arthritis, three with cervical fracture-dislocation, and two with spinal metastasis. Twenty-four pedicle screws (3.5 mm diameter: Vertex, Medtronic Sofamordanek) were placed into the pedicle from C2 to T2 level by free-handed technique2). Grade of breaching of pedicle cortex was divided into four groups (Grade 0–3). In addition, screw axis angle (SAA) were calculated from the horizontal and sagittal CT images and compared with pedicle transverse angle (PTA). Furthermore, perioperative complications were also examined. Our free-handed pedicle screw placement with carving technique is as follows: A longitudinal gutter was created at the lamina-lateral mass junction and then transverse gutter perpendicular to the longitudinal gutter was made at the lateral notch of lateral mass. The entry point of the pedicle screw was on the midline of lateral mass. Medial pedicle cortex through the ventral lamina was identified using the probes to create the hole within the pedicle. The hole was tapped and the screw was gently introduced into the pedicle to ensure the sagittal trajectory using fluoroscopy. In the transverse direction, 22 out of 24 screws (92%) were entirely contained within the pedicle (Grade 0). In contrast, only teo screws (8%) produced breaches less than half the screw diameter (Grade 1). In the sagittal direction, all screws were within the pedicle (Grade 0). Screw trajectories were not consistent with anatomical pedicle axis angle; the mean SAA were smaller than the mean PTA at all levels. The pedicle diameter ranged from 3.9 to 9.2 mm. The mean value gradually increased toward the caudal level. There were no neurological and vascular complications related to screw placement


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 143 - 143
1 Sep 2012
Kreshak JL Fabbri N Manfrini M Gebhardt M Mercuri M
Full Access

Purpose. Rotationplasty was first described in 1930 by Borggreve for treatment of limb shortening with knee ankylosis after tuberculosis. In 1948, Van Nes described its use for management of congenital defects of the femur and in the 1980s, Kotz and Salzer reported on patients with malignant bone tumors around the knee treated by rotationplasty as an alternative to above-knee amputation. Currently, rotationplasty is one of the options for surgical management of lower extremity bone sarcomas in skeletally immature patients but alternative limb salvage techniques, such as the use of expandable endoprosthesis, are also available. Despite rather satisfactory functional results have been uniformly associated with rotationplasty, concern still exists about the potential psychological impact of the new body imagerelated to the strange appearance of the rotated limb. Results of rotationplasty for sarcomas of the distal femur over a 20-year period were analyzed, focusing on long-term survival, function, quality of life and mental health. Method. Retrospective study of 73 children who had a rotationplasty performed at two institutions between 1984 and 2007 for a bone sarcoma of the distal femur; 42 males and 31 females, mean age at surgery 8.7 yrs (range 3–17). Four patients were converted to transfemoral amputation due to early vascular complication; 25 eventually died of their disease (mean survival 34 months, range 4–127). The 46 remaining survivors were evaluated for updated clinical outcome, MSTS score, gait analysis, SF-36 score, quality of life interview and psychological assessment at mean follow-up of 15 yrs (range 3–23). Results. Overall survival was 64%. All the survivors were disease-free at last follow-up. Four patients required hardware revision for nonunion and subsequently healed. Three patients refused participation in the long-term follow-up study. Mean MSTS score was 79 (range 64–88). SF-36 score was obtained in 35 patients (age > 16); male patients showed a trend toward greater activity and vitality. Compared to age-group norms, rotationplasty scores were lower for physical activity level (p <0.05) and higher for general health perception (p = 0.05) and mental health (p < 0.05). Conclusion. Rotationplasty remains a durable reconstructive option with good long-term function and acceptable psychological impact for children with bone sarcomas of the distal femur


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 3 - 3
1 Mar 2013
Alizadehkhaiyat O Kyriakos A Williams A Frostick S Al Mandhari A
Full Access

BACKGROUND. Reverse total shoulder arthroplasty (RTSA) provides an alternative to standard total shoulder arthroplasty in the treatment of selected complex shoulder problems including failed shoulder replacements. The purpose of this report is to present outcome of RTSA using Comprehensive Reverse System (CRS) as either primary or revision treatment choice. PATIENTS AND MATERIALS. Between September 2010 and April 2012, 54 patients (36 females, 18 males) with the mean age of 68.4 (±10) underwent RTSA-CRS. In 27 patients RTSA-CRS was performed as a revision due to failed previous arthroplasty. Primary underlying conditions included AVN (2), massive irreparable rotator cuff tear (2), primary osteoarthritis (7), post-traumatic osteoarthritis (2), rheumatoid arthritis (6), and rotator cuff arthropathy (8). It was not possible to complete the operation in 6 patients (4 revisions group 2 AVN cases) due to substantial glenoid erosion. Preoperative CT scan was performed in 50% of patients to assess the bony stock of the glenoid. In some patients ultrasound and MRI were performed to acquire additional information. A total of 46 patients were followed-up by means of antroposterior and axial plain X-rays, pain and satisfaction level (VAS/0–10), stiffness, Constant Score, Oxford Shoulder Score, SF-12 (Physical and mental Subscales), and range of movement for a mean duration of 6.5 months (±4.2). RESULTS. The table presents the pre- and postoperative outcome variables for both primary and revision RTSA-CRS groups. The majority of outcome measures indicated a considerable improvement in both groups during the short term follow-up. Significant correlations were noted in-between some key outcome variables. However; due to the short period of follow-up and continuity of collecting data, we intend to produce a more realistic picture of the results s and outcome of the RTSA-CRS in coming years. COMPLICATIONS. There was no vascular complication. Disassociation of glenosphere from the base-plate happened in one patient 8 weeks post-op due to technical mistake, this was repaired later with a satisfactory outcome. One case had enormous hematoma formation 72 hours post-op due to anticoagulants administration leading to second stage evacuation and increased stiffness of shoulder. One patient sustained deltoid partial rupture due to recurrent falls and managed by conservatively. Another patient sustained a type C periprosthetic fracture and was later revised to custom-made stem prosthesis. CONCLUSION. The results of this short-term report indicate a satisfactory and acceptable outcome for RTSA-CRS as reflected in the assessment tools in both primary and revision cases, however with superior results in the primary group. Long-term follow-up is essential to have a more rational assessment of the clinical outcome as well as associated complications