Total temporomandibular joint (TMJ) replacements reduce pain and improve quality of life in patients suffering from end-stage TMJ disorders, such as osteoarthritis and trauma. Jaw kinematics measurements following TMJ arthroplasty provide a basis for evaluating implant performance and jaw function. The aim of this study is to provide the first measurements of three-dimensional kinematics of the jaw in patients following
Background. The current average tariff of a total knee replacement (TKR) is £5500. The approximate cost of each knee prosthesis is £2500. Therefore, length of patient stay (LOS) and the cost of patient rehabilitation influence the total costs significantly. Previous studies have shown a mean LOS of between 5 and 9.4 days for patients undergoing primary unilateral TKR but none looked at the factors influencing length of stay following bilateral primary total knee replacements (BTKR) at the same sitting. Objectives. To identify significant factors that influence the LOS following BTKR at the same sitting in a single centre in the UK. Methods. This was a retrospective single-centre study performed at the Princess Royal Hospital which performed a total of 25 BTKR. Surgical and patient factors that may influence LOS were recorded and analysed. Results. The mean LOS was 10 days with a median of 9 days. 64% were discharged within 10 days. Those staying longer were classified as long stayers. Being a female (0.65, p< 0.05), having a higher Charlson index (0.68, p< 0.05) and having a post-operative blood transfusion (0.59, p< 0.05) were the only significant factors that influenced LOS. Post-operative acute kidney injury (AKI), underlying diagnosis such as rheumatoid arthritis, BMI, age, worse pre-operative oxford knee scores and type of implant did not influence LOS. Conclusion. Factors influencing LOS following BTKR shown in our study seems to be the same as those influencing unilateral TKRs as identified in the literature. This should be taken into consideration when comparing
To prevent the reported side effects of rhBMP-2, an important cytokine with bone forming capacity, the sustained release of rhBMP-2 is highly important. Synthetic copolymer polylactic acid-polyethylene glycol (PLA-PEG) is already shown to be a good carrier for rhBMP-2. The nano-sized hydroxyapatite (nHAp) is mentioned to be superior to conventional hydroxyapatite due to its decreased particle size which increases the surface area, so protein-cell adhesion and mechanical properties concomitantly. In the literature no study is reported with PLA-PEG / rhBMP-2/ nHAp for bone regeneration. In this study, we assessed the controlled release profile of rhBMP-2 from the novel biomaterial of PLA-PEG / rhBMP-2 / nHAp in vitro and evaluated the bone forming capacity of the composite in rat posterolateral spinal fusion (PSF) model in vivo. Composites were prepared via addition of rhBMP-2 (0µg, 3µg or 10µg) and nHAp (12.5mg) into PLA-PEG (5mg) + acetone solution and shaping. The release kinetics of the cytokine from the composites with 5µg BMP-2 was investigated by ELISA. The effect of nHAp and nHAp with rhBMP-2 on cell differentiation (rat BMSC cells, passage 3) was tested with ALP staining. In vivo bone formation was investigated by PSF on L4-L5 in a total of 36 male SD rats and weekly µCT results and histology at 8. th. weeks post operation were used for assessment of the bone formation. All animal experiments was approved by the institutional review board confirming to the laws and regulations of Japan. The composite showed an initial burst release in the first 24 hours (51.7% of the total released rhBMP-2), but the release was continued for the following 21 days. Thus, the sustained release of rhBMP-2 from the composite was verified. ALP staining results showed nHAp with rhBMP-2 contributed better on differentiation than nHAp itself. µCT and histology demonstrated that spinal fusion was achieved either one or both transverse processes in almost all BMP 3µg and BMP 10µg treated animals. On the contrary, only small or no bone formation was observed in the BMP0µg group (bilateral non-union /
An increase in metal ion levels is seen after implantation of all MoM hip prosthesis due to release from the surface directly, more so during articulation and corrosion of the bearing surfaces. The bearing surfaces in MoM prosthesis consist of cobalt, chromium and molybdenum. Several case-reports of cobalt toxicity due to a MoM prosthesis have been published in the last decade. Cobalt intoxication may lead to a variety of symptoms: neuro-ocular toxicity (tinnitus, vertigo, deafness, blindness, convulsions, headaches and peripheral neuropathy), cardiotoxicity and thyroid toxicity. Nausea, anorexia and unexplained weight loss have been described. Systemic effects from metal ions even with well functioning implants or with ion concentrations lower than those associated with known adverse effects may exist and warrant investigation. The aim of this study is to investigate self-reported systemic complaints in association with cobalt ion concentrations in patients with any type of MoM hip prosthesis. A cohort study was conducted. Patients with both
Background. The second generation metal-on-metal (MoM) prosthesis of the hip became a worldwide success in the 90s. However, after the placement of a MoM prosthesis the cobalt ion concentrations raise significantly. This may lead to systemic complaints and even cobalt toxicity. Methods. Sixty-one patients (26F/35M) with both an
Systemic metal ion monitoring (Co;Cr) has proven to be a useful screening tool for implant performance to detect failure at an early stage in metal-on-metal hip arthroplasty. Several clinical studies have reported elevated metal ion levels after total knee arthroplasty (TKA), with fairly high levels associated with rotating hinge knees (RHK) and megaprostheses. 1. In a knee simulator study, Kretzer. 2. , demonstrated volumetric wear and corrosion of metallic surfaces. However, prospective in vivo data are scarce, resulting in a lack of knowledge of how levels evolve over time. The goal of this study was to measure serum Co and Cr levels in several types TKA patients prospectively, evaluate the evolution in time and investigate whether elevated levels could be used as an indicator for implant failure. The study was conducted at Ghent University hospital. 130 patients undergoing knee arthroplasty were included in the study, 35 patients were lost due to logistic problems. 95 patients with 124 knee prostheses had received either a TKA (primary or revision) (69 in 55 patients), a unicompartimental knee arthroplasty (7 UKA), a RHK (revision −7 in 6 patients) or a megaprosthesis (malignant bone tumours − 28 in 27 patients). The TKA, UKA and RHK groups were followed prospectively, with serum Co and Cr ions measured preoperatively, at 3,6 and 12 months postoperatively. In patients with a megaprosthesis, metal ions were measured at follow-up (cross-sectional study design). In primary knees, we did not observe an increase in serum metal ion levels at 3, 6 or 12 months. Two patients with a hip arthroplasty had elevated preTKA Co and Cr levels. There was no difference between
Introduction. The goal of joint-preserving surgery for the treatment of osteonecrosis of the femoral head (ONFH) is to delay or prevent osteoarthritic development. Bone marrow is a source of osteogenic progenitors that are key elements in the process of bone formation and fracture healing. We established an easy-to-use method using a conventional manual blood bag centrifugation technique traditionally used for extracting buffy coats, for concentration of nucleated cells and platelets from clinical bone marrow aspirates to obtain osteogenic progenitors and growth factors. However, it is unclear whether the surgical goals are really achieved and if so in which patients. The purpose of this study was to identify demographic, clinical, and radiographic factors predicting total hip arthroplasty (THA) conversion after CABMAT for the treatment of idiopathic ONFH. Methods. We retrospectively reviewed 123 patients (213 hips) who had CABMAT between 2003 and 2010. Sixty-five subjects (115 hips) were male and 58 (98 hips) were female with an average age at the time of CABMAT of 40.1 years. Of the 213 hips, 143 hips in 78 patients had corticosteroid-induced ONFH, 46 hips in 27 patients had alcohol-associated, and 24 hips in 18 patients had no etiological factors could be detected. The mean follow-up period was 60.5 months. The endpoint of evaluation was set as the time point which the patient required additional surgery (THA) depending on the spontaneous hip pain, x-ray change, and social back ground. The following factors were investigated: age, sex, body mass index (BMI),
Post-mortem retrieval of canine, cemented femoral components was analysed to assess the performance of these implants in the dog as a model for human total hip replacement (THR). Mechanical testing and radiological analysis were performed to determine the stability of the implant and the quality of the cement. Thirty-eight implants from 29 dogs were retrieved after time intervals ranging from 0.67 to 11.67 years. The incidence of aseptic loosening was 63.2%, much higher than in human patients (6% in post-mortem studies). Failure of the femoral implants began with debonding at the cement-metal interface, similar to that in implants in man. The incidence of aseptic loosening was much lower in bilateral than in unilateral implants. Significant differences were observed for three different designs of implant. While the dog remains the animal model of choice for THR, results from this study provide insight into interspecies differences in the performance of implants. For example, the performance of THR in dogs should be compared with that in young rather than in elderly human patients.
We carried out a cross-sectional study with analysis of the demographic, clinical and laboratory characteristics of patients with metal-on-metal hip resurfacing, ceramic-on-ceramic and metal-on-polyethylene hip replacements. Our aim was to evaluate the relationship between metal-on-metal replacements, the levels of cobalt and chromium ions in whole blood and the absolute numbers of circulating lymphocytes. We recruited 164 patients (101 men and 63 women) with hip replacements, 106 with metal-on-metal hips and 58 with non-metal-on-metal hips, aged <
65 years, with a pre-operative diagnosis of osteoarthritis and no pre-existing immunological disorders. Laboratory-defined T-cell lymphopenia was present in13 patients (15%) (CD8+ lymphopenia) and 11 patients (13%) (CD3+ lymphopenia) with unilateral metal-on-metal hips. There were significant differences in the absolute CD8+ lymphocyte subset counts for the metal-on-metal groups compared with each control group (p-values ranging between 0.024 and 0.046). Statistical modelling with analysis of covariance using age, gender, type of hip replacement, smoking and circulating metal ion levels, showed that circulating levels of metal ions, especially cobalt, explained the variation in absolute lymphocyte counts for almost all lymphocyte subsets.