Advertisement for orthosearch.org.uk
Results 1 - 9 of 9
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 124 - 124
11 Apr 2023
Woodford S Robinson D Lee P Abduo J Dimitroulis G Ackland D
Full Access

Total temporomandibular joint (TMJ) replacements reduce pain and improve quality of life in patients suffering from end-stage TMJ disorders, such as osteoarthritis and trauma. Jaw kinematics measurements following TMJ arthroplasty provide a basis for evaluating implant performance and jaw function. The aim of this study is to provide the first measurements of three-dimensional kinematics of the jaw in patients following unilateral and bilateral prosthetic TMJ surgeries. Jaw motion tracking experiments were performed on 7 healthy control participants, 3 unilateral and 1 bilateral TMJ replacement patients. Custom-made mouthpieces were manufactured for each participant's mandibular and maxillary teeth, with each supporting three retroreflective markers anterior to the participant's lip line. Participants performed 15 trials each of maximum jaw opening, lateral and protrusive movements. Marker trajectories were simultaneously measured using an optoelectronic tracking system. Laser scans taken of each dental plate, together with CT scans of each patient, were used to register the plate position to each participant's jaw geometry, allowing 3D condylar motion to be quantified from the marker trajectories. The maximum mouth opening capacity of joint replacement patients was comparable to healthy controls with average incisal inferior translations of 37.5mm, 38.4mm and 33.6mm for the controls, unilateral and bilateral joint replacement patients respectively. During mouth opening the maximum anterior translation of prosthetic condyles was 2.4mm, compared to 10.6mm for controls. Prosthetic condyles had limited anterior motion compared to natural condyles, in unilateral patients this resulted in asymmetric opening and protrusive movements and the capacity to laterally move their jaw towards their pathological side only. For the bilateral patient, protrusive and lateral jaw movement capacity was minimal. Total TMJ replacement surgery facilitates normal mouth opening capacity and lateral and inferior condylar movements but limits anterior condylar motion. This study provides future direction for TMJ implant design


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 110 - 110
1 Dec 2020
Kabariti R Roach R
Full Access

Background. The current average tariff of a total knee replacement (TKR) is £5500. The approximate cost of each knee prosthesis is £2500. Therefore, length of patient stay (LOS) and the cost of patient rehabilitation influence the total costs significantly. Previous studies have shown a mean LOS of between 5 and 9.4 days for patients undergoing primary unilateral TKR but none looked at the factors influencing length of stay following bilateral primary total knee replacements (BTKR) at the same sitting. Objectives. To identify significant factors that influence the LOS following BTKR at the same sitting in a single centre in the UK. Methods. This was a retrospective single-centre study performed at the Princess Royal Hospital which performed a total of 25 BTKR. Surgical and patient factors that may influence LOS were recorded and analysed. Results. The mean LOS was 10 days with a median of 9 days. 64% were discharged within 10 days. Those staying longer were classified as long stayers. Being a female (0.65, p< 0.05), having a higher Charlson index (0.68, p< 0.05) and having a post-operative blood transfusion (0.59, p< 0.05) were the only significant factors that influenced LOS. Post-operative acute kidney injury (AKI), underlying diagnosis such as rheumatoid arthritis, BMI, age, worse pre-operative oxford knee scores and type of implant did not influence LOS. Conclusion. Factors influencing LOS following BTKR shown in our study seems to be the same as those influencing unilateral TKRs as identified in the literature. This should be taken into consideration when comparing unilateral versus bilateral TKR results as well as when planning a local arthroplasty service


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 86 - 86
1 Dec 2020
Bal Z Kaito T Ishiguro H Okada R Kanayama S Kushioka J Kodama J Chijimatsu R Korkusuz P Dede EÇ Gizer M Yoshikawa H Korkusuz F
Full Access

To prevent the reported side effects of rhBMP-2, an important cytokine with bone forming capacity, the sustained release of rhBMP-2 is highly important. Synthetic copolymer polylactic acid-polyethylene glycol (PLA-PEG) is already shown to be a good carrier for rhBMP-2. The nano-sized hydroxyapatite (nHAp) is mentioned to be superior to conventional hydroxyapatite due to its decreased particle size which increases the surface area, so protein-cell adhesion and mechanical properties concomitantly. In the literature no study is reported with PLA-PEG / rhBMP-2/ nHAp for bone regeneration. In this study, we assessed the controlled release profile of rhBMP-2 from the novel biomaterial of PLA-PEG / rhBMP-2 / nHAp in vitro and evaluated the bone forming capacity of the composite in rat posterolateral spinal fusion (PSF) model in vivo. Composites were prepared via addition of rhBMP-2 (0µg, 3µg or 10µg) and nHAp (12.5mg) into PLA-PEG (5mg) + acetone solution and shaping. The release kinetics of the cytokine from the composites with 5µg BMP-2 was investigated by ELISA. The effect of nHAp and nHAp with rhBMP-2 on cell differentiation (rat BMSC cells, passage 3) was tested with ALP staining. In vivo bone formation was investigated by PSF on L4-L5 in a total of 36 male SD rats and weekly µCT results and histology at 8. th. weeks post operation were used for assessment of the bone formation. All animal experiments was approved by the institutional review board confirming to the laws and regulations of Japan. The composite showed an initial burst release in the first 24 hours (51.7% of the total released rhBMP-2), but the release was continued for the following 21 days. Thus, the sustained release of rhBMP-2 from the composite was verified. ALP staining results showed nHAp with rhBMP-2 contributed better on differentiation than nHAp itself. µCT and histology demonstrated that spinal fusion was achieved either one or both transverse processes in almost all BMP 3µg and BMP 10µg treated animals. On the contrary, only small or no bone formation was observed in the BMP0µg group (bilateral non-union / unilateral fusion/ bilateral fusion, BMP0µg group; 9/0/0, BMP3µg group; 1/0/11, BMP10µg group; 0/1/11). We developed a new technology for bone regeneration with BMP-2/PLA-PEG/nHAp composite. With this composite, the required dose of BMP-2 for spinal fusion in rats (10µg) was decreased to 1/3 (3µg) which can be explained by the superior properties of nano-sized hydroxyapatite and by the achievement of sustainable release of rhBMP-2 from the composite. This study is supported by Japanese Society of the Promotion of Science (JSPS) and Scientific and Technological Research Council of Turkey (TUBITAK). [Project No: 215S834]


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 124 - 124
1 Mar 2021
Jelsma J Schotanus M Kleinveld H Grimm B Heyligers I
Full Access

An increase in metal ion levels is seen after implantation of all MoM hip prosthesis due to release from the surface directly, more so during articulation and corrosion of the bearing surfaces. The bearing surfaces in MoM prosthesis consist of cobalt, chromium and molybdenum. Several case-reports of cobalt toxicity due to a MoM prosthesis have been published in the last decade. Cobalt intoxication may lead to a variety of symptoms: neuro-ocular toxicity (tinnitus, vertigo, deafness, blindness, convulsions, headaches and peripheral neuropathy), cardiotoxicity and thyroid toxicity. Nausea, anorexia and unexplained weight loss have been described. Systemic effects from metal ions even with well functioning implants or with ion concentrations lower than those associated with known adverse effects may exist and warrant investigation. The aim of this study is to investigate self-reported systemic complaints in association with cobalt ion concentrations in patients with any type of MoM hip prosthesis. A cohort study was conducted. Patients with both unilateral and bilateral, resurfacing and large head metal on metal total hip arthroplasties were included for the current study. Blood metal ion concentrations (cobalt and chromium) were measured by inductively coupled plasma mass spectrometry (ICP-MS). Based on the known cobalt toxicity symptoms of case-reports and toxicology reports a new non-validated questionnaire was developed. questions were subdivided in general questions/symptoms, vestibular symptoms, neurological symptoms, emotional health and cardio- and thyroid toxicity symptoms. Independent samples T test, Fishers Exact Test and Pearsons (R) correlation were used. Analysis was performed on two groups; a low cobalt ion concentration group and a high cobalt ion concentration group A total of 62 patients, 36 (58%) men and 26 (42%) women, were included with a mean age at surgery of 60.8 ± 9.3 years (41.6 – 78.1) and a mean follow up of 6.3 ± 1.4years (3.7 – 9.6). In these patients a total of 71 prosthesis were implanted: 53 unilateral and 9 bilateral. Of these, 44 were resurfacing and 27 large head metal on metal (LHMoM) total hip arthroplasties. Mean cobalt and chromium ion concentrations were 104 ± 141 nmol/L (9 – 833) and 95 ± 130nmol/L (6 – 592), respectively. Based on the different thresholds (120 – 170 or 220 nmol/L) the low cobalt ion concentration group consisted of 44 (71%), 51 (82%) or 55 (89%) subjects respectively. No differences were found in general characteristics, independently of the threshold. The composite score of vestibular symptoms (vision, hearing, tinnitus, dizziness) was significantly higher (p < .050) in all high cobalt ion concentrations groups, independent of the threshold value This study aimed to detect a trend in self-reported systemic complaints in patients with metal-on-metal hip arthroplasty due to raised cobalt ion concentrations. Vestibular symptoms were more common in high cobalt ion concentration groups independent of the three threshold levels tested. The upper limit of acceptable cobalt ion concentrations remains uncertain. With regards to proactively inquired, self-reported symptoms the threshold where effects may be present could be lower than values currently applied in clinical follow-up. It is unknown what exposure to elevated metal ion concentrations for a longer period of time causes with aging subjects. Further research with a larger cohort and a more standardized questionnaire is necessary to detect previously undiscovered or under-reported effects


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 47 - 47
1 Apr 2017
Jelsma J Senden R Schotanus M Kort N Grimm B Heyligers I
Full Access

Background. The second generation metal-on-metal (MoM) prosthesis of the hip became a worldwide success in the 90s. However, after the placement of a MoM prosthesis the cobalt ion concentrations raise significantly. This may lead to systemic complaints and even cobalt toxicity. Methods. Sixty-one patients (26F/35M) with both an unilateral and bilateral resurfacing or large-head MoM (LHMoM) hip prosthesis were included. At last follow-up (5.77 ± 1.57 yrs) cobalt concentrations in the blood were determined by ICP-MS. Based on the known cobalt toxicity symptoms we developed a non-validated questionnaire. Analysis was done on two groups; a low cobalt concentration group and a high cobalt concentration group. We used 170 nmol/L as the upper limit of well functioning prosthesis as defined by the Dutch Orthopaedic Society (NOV). Independent samples T test and Pearson correlation coefficient were done. Results. In 61 patients, 70 prosthesis were implanted: 44 resurfacings and 26 LHMoM. Mean cobalt and chromium ion concentrations were 110 ± 138 (9 – 833) and 104 ± 138 (6 – 592) nmol/L. The low cobalt concentration group consisted of 52 patients, while the high cobalt concentration group consisted of 9 hips. With respect to the systemic complaints, the subjects in the high or low group reported no significant differences. A trend towards more complaints with visual problems (75% vs 51.9%, P = .089) and dizziness (62.5% vs 38.9%, P = .098) was notable in the high cobalt concentration group. Conclusions. Metal on metal hip arthroplasty stays controversial for the possible side-effects. This study shows trends, but no significance, in systemic complaints from high cobalt ion concentrations. Complaints of neuro-ocular toxicity are most common. This is in correspondence with other literature, although the upper limit for cobalt ion concentrations remains uncertain. Level of Evidence. 2b. Disclosure. no financial or nonfinancial relationships to disclose


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 69 - 69
1 Jan 2017
Van Der Straeten C Banica T De Smet A Van Onsem S Sys G
Full Access

Systemic metal ion monitoring (Co;Cr) has proven to be a useful screening tool for implant performance to detect failure at an early stage in metal-on-metal hip arthroplasty. Several clinical studies have reported elevated metal ion levels after total knee arthroplasty (TKA), with fairly high levels associated with rotating hinge knees (RHK) and megaprostheses. 1. In a knee simulator study, Kretzer. 2. , demonstrated volumetric wear and corrosion of metallic surfaces. However, prospective in vivo data are scarce, resulting in a lack of knowledge of how levels evolve over time. The goal of this study was to measure serum Co and Cr levels in several types TKA patients prospectively, evaluate the evolution in time and investigate whether elevated levels could be used as an indicator for implant failure. The study was conducted at Ghent University hospital. 130 patients undergoing knee arthroplasty were included in the study, 35 patients were lost due to logistic problems. 95 patients with 124 knee prostheses had received either a TKA (primary or revision) (69 in 55 patients), a unicompartimental knee arthroplasty (7 UKA), a RHK (revision −7 in 6 patients) or a megaprosthesis (malignant bone tumours − 28 in 27 patients). The TKA, UKA and RHK groups were followed prospectively, with serum Co and Cr ions measured preoperatively, at 3,6 and 12 months postoperatively. In patients with a megaprosthesis, metal ions were measured at follow-up (cross-sectional study design). In primary knees, we did not observe an increase in serum metal ion levels at 3, 6 or 12 months. Two patients with a hip arthroplasty had elevated preTKA Co and Cr levels. There was no difference between unilateral and bilateral knee prostheses. In the revision group, elevated pre-revision levels were found in 2 failures for implant loosening. In both cases, ion levels decreased postoperatively. In revisions with a standard TKA, there was no significant increase in metal ions compared to primary knee arthroplasty. RHK were associated with a significant increase in Co levels even at short-term (3–12 months). The megaprosthesis group had the highest metal ion levels and showed a significant increase in Co and Cr with time in patients followed prospectively. With the current data, we could not demonstrate a correlation between metal ion levels, size of the implant or length of time in situ. In primary knee arthroplasty with a standard TKA or UKA, metal ion levels were not elevated till one year postoperatively. This suggests a different mechanism of metal ion release in comparison to metal-on-metal hip arthroplasties. In two cases of revision for implant loosening, pre-revision levels were elevated, possibly associated with component wear, and decreased after revision. With RHK, slightly elevated ion levels were found prospectively. Megaprostheses had significantly elevated Co and Cr levels, due to corrosion of large metallic surfaces and/or wear of components which were not perfectly aligned during difficult reconstruction after tumour resection. Further research is needed to assess the clinical relevance of metal ion levels in knee arthroplasty


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 349 - 349
1 Jul 2014
Hyodo K Yoshioka T Akaogi H Sugaya H Aoto K Wada H Sakai S Yamazaki M Mishima H
Full Access

Introduction. The goal of joint-preserving surgery for the treatment of osteonecrosis of the femoral head (ONFH) is to delay or prevent osteoarthritic development. Bone marrow is a source of osteogenic progenitors that are key elements in the process of bone formation and fracture healing. We established an easy-to-use method using a conventional manual blood bag centrifugation technique traditionally used for extracting buffy coats, for concentration of nucleated cells and platelets from clinical bone marrow aspirates to obtain osteogenic progenitors and growth factors. However, it is unclear whether the surgical goals are really achieved and if so in which patients. The purpose of this study was to identify demographic, clinical, and radiographic factors predicting total hip arthroplasty (THA) conversion after CABMAT for the treatment of idiopathic ONFH. Methods. We retrospectively reviewed 123 patients (213 hips) who had CABMAT between 2003 and 2010. Sixty-five subjects (115 hips) were male and 58 (98 hips) were female with an average age at the time of CABMAT of 40.1 years. Of the 213 hips, 143 hips in 78 patients had corticosteroid-induced ONFH, 46 hips in 27 patients had alcohol-associated, and 24 hips in 18 patients had no etiological factors could be detected. The mean follow-up period was 60.5 months. The endpoint of evaluation was set as the time point which the patient required additional surgery (THA) depending on the spontaneous hip pain, x-ray change, and social back ground. The following factors were investigated: age, sex, body mass index (BMI), unilateral or bilateral, etiological factors, preoperative classification and staging, visual analogue scale (VAS), JOA clinical score. The 213 hips were divided into two groups: a THA conversion (THA) group and a non-THA conversion (non-THA) group. A multivariate analysis was performed using a logistic regression model. Results. In this series, of the 213 hips, 51 hips (23.9%) in 37 patients converted THA. The mean age of patients in THA group was 43.0 years and that of non-THA group was 39.2 years. The mean duration between CABMAT and THA conversion was 26.9 months. Preoperatively, 11 of the 213 hips were classified as type A, 8 hips as type B, 78 hips as type C1, and 116 hips as type C2. 48 hips were classified as stage 1, 65 hips as stage 2, 58 as Stage 3A, 34 as Stage 3B, 8 as stage 4. Postoperatively, no hips in types A and B, 11 hips (14.1%) in type C1, 40 hips (34.5%) in type C2, and 8 hips (16.7%) in stage 1, 13 hips (25.0%) in stage 2, 14 hips (24.1%) in stage 3A, 11 hips (32.4%) in stage 3B, 5 hips (62.5%) in stage 4 were converted THA. Conclusions. The strongest predictors of THA conversion after CABMAT were type, the extent of necrotic area, and age. The results suggest that what factors determine the THA conversion after CABMAT and which patients of idiopathic ONFH are appropriate for CABMAT treatment. Further careful follow-up is needed clinically, and an additional treatment strategy to improve CABMAT is currently in progress


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 1 | Pages 120 - 127
1 Jan 2005
Skurla CP Pluhar GE Frankel DJ Egger EL James SP

Post-mortem retrieval of canine, cemented femoral components was analysed to assess the performance of these implants in the dog as a model for human total hip replacement (THR). Mechanical testing and radiological analysis were performed to determine the stability of the implant and the quality of the cement. Thirty-eight implants from 29 dogs were retrieved after time intervals ranging from 0.67 to 11.67 years. The incidence of aseptic loosening was 63.2%, much higher than in human patients (6% in post-mortem studies). Failure of the femoral implants began with debonding at the cement-metal interface, similar to that in implants in man. The incidence of aseptic loosening was much lower in bilateral than in unilateral implants. Significant differences were observed for three different designs of implant. While the dog remains the animal model of choice for THR, results from this study provide insight into interspecies differences in the performance of implants. For example, the performance of THR in dogs should be compared with that in young rather than in elderly human patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 6 | Pages 835 - 842
1 Jun 2009
Hart AJ Skinner JA Winship P Faria N Kulinskaya E Webster D Muirhead-Allwood S Aldam CH Anwar H Powell JJ

We carried out a cross-sectional study with analysis of the demographic, clinical and laboratory characteristics of patients with metal-on-metal hip resurfacing, ceramic-on-ceramic and metal-on-polyethylene hip replacements. Our aim was to evaluate the relationship between metal-on-metal replacements, the levels of cobalt and chromium ions in whole blood and the absolute numbers of circulating lymphocytes. We recruited 164 patients (101 men and 63 women) with hip replacements, 106 with metal-on-metal hips and 58 with non-metal-on-metal hips, aged < 65 years, with a pre-operative diagnosis of osteoarthritis and no pre-existing immunological disorders.

Laboratory-defined T-cell lymphopenia was present in13 patients (15%) (CD8+ lymphopenia) and 11 patients (13%) (CD3+ lymphopenia) with unilateral metal-on-metal hips. There were significant differences in the absolute CD8+ lymphocyte subset counts for the metal-on-metal groups compared with each control group (p-values ranging between 0.024 and 0.046). Statistical modelling with analysis of covariance using age, gender, type of hip replacement, smoking and circulating metal ion levels, showed that circulating levels of metal ions, especially cobalt, explained the variation in absolute lymphocyte counts for almost all lymphocyte subsets.