Advertisement for orthosearch.org.uk
Results 1 - 20 of 282
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 33 - 33
1 Feb 2012
Karthikeyan S Rai S Drew S
Full Access

Introduction. In patients with shoulder pain one of the important initial determinations is to assess the integrity of the rotator cuff. Clinical examination is often inconclusive. Compared with MRI and arthrography, ultrasound allows dynamic evaluation, is non-invasive, less expensive, less time-consuming and more acceptable to patients. The aim of the present study was to evaluate the accuracy of high resolution shoulder ultrasonography compared with arthroscopy in a series of consecutive patients with clinically suspected rotator cuff disease. Materials and methods. 100 shoulders in 99 consecutive patients with shoulder pain who had undergone standardised pre-operative ultrasonography and subsequent arthroscopy between May 2004 and March 2006 were included in the study. There were 53 males and 46 females with a mean age of 59 years. The mean time interval between the ultrasonographic and the arthroscopic examinations was 227 days. For full thickness tears ultrasonography showed a sensitivity of 100%, specificity 83%, positive predictive value 80%, negative predictive value 100% and accuracy 90%. Ultrasonography showed a sensitivity of 83% in detecting partial thickness tears, specificity 94%, positive predictive value 86%, negative predictive value 93% and accuracy 91%. Discussion. The use of high resolution shoulder ultrasonography to diagnose rotator cuff tears has achieved only limited acceptance by orthopaedic surgeons. Refinements in scanning technique, modern equipment with improved resolution capabilities and clarification of criteria for diagnosing rotator cuff tears have improved the accuracy of shoulder ultrasonography. Conclusion. In our experience ultrasonography is found to be a highly accurate technique for detecting rotator cuff tears. However the success of an ultrasonographic examination is heavily dependent on the experience of the operator


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 358 - 358
1 Jul 2008
Karthikeyan S Rai S Drew S
Full Access

The use of high resolution ultrasonography for the detection of rotator cuff tears has achieved only limited acceptance by orthopaedic surgeons. Uncertainty about the accuracy of ultrasonography may be a contributing factor. The purpose of this study was to evaluate the accuracy of high-resolution ultrasonography compared to shoulder arthroscopy in the detection of rotator cuff tears. 100 consecutive patients with shoulder pain in whom arthroscopic surgery was planned underwent standardized preoperative ultrasonography. The ultrasound examinations were done by a single experienced musculoskeletal radiologist using a standard protocol. The findings at ultrasound were classified into intact cuff, tendinopathy, partial-thickness tear, and full-thickness rotator cuff tears. The size of the tear was measured in centimetres. The location was designated as subscapularis, supraspinatus, infraspinatus, or a combination. All of the subsequent shoulder arthroscopies were done by a single surgeon. The presence or absence of a rotator cuff tear and the size and extent of the tear when present were recorded. We then compared the ultrasonographic findings with the definitive operative findings. For the detection of rotator cuff tears, ultrasound had a sensitivity of 95% and a specificity of 94%; accuracy 95%. There was 100% sensitivity for full thickness tears (specificity 91% and accuracy 95%), while for partial-thickness tears there was a sensitivity of 80%, (specificity 98% and accuracy 95%). In experienced hands, ultrasound is a highly accurate diagnostic method for detecting rotator cuff tears. The results of this study compare favourably with the published results of magnetic resonance imaging for the investigation of this condition. Furthermore, dynamic imaging and comparison with the opposite shoulder is possible with ultrasonography


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 421 - 422
1 May 1993
Kosuwon W Mahaisavariya B Saengnipanthkul S Laupattarakasem W Jirawipoolwon P

We used ultrasonography in ten children with pulled elbow to compare measurements of the radiocapitellar distance (RCD) on the affected and the unaffected sides. Similar measurements were made in a group of ten age-matched normal children. The mean RCD in pronation of the affected and normal sides in the patients with pulled elbows was 7.2 mm +/- 0.7 and 3.8 mm +/- 0.5, respectively (p < 0.0001). In the normal children the mean RCD in pronation was 4.5 mm +/- 0.5. We conclude that ultrasonography is of value for documenting pulled elbow in children


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 6 | Pages 762 - 765
1 Jun 2009
Toros T Karabay N Özaksar K Sugun TS Kayalar M Bal E

We prospectively studied 26 consecutive patients with clinically documented sensory or motor deficiency of a peripheral nerve due to trauma or entrapment using ultrasound, and in 19 cases surgical exploration of the nerves was undertaken. The ultrasonographic diagnoses were correlated with neurological examination and the surgical findings. Reliable visualisation of injured nerves on ultrasonography was achieved in all patients. Axonal swelling and hypoechogenity of the nerve was diagnosed in 15 cases, loss of continuity of a nerve bundle in 17, the formation of a neuroma of a stump in six, and partial laceration of a nerve with loss of the normal fascicular pattern in five. The ultrasonographic findings were confirmed at operation in those who had surgery. Ultrasound may be used for the evaluation of peripheral nerve injuries in the upper limb. High-resolution ultrasound can show the exact location, extent and type of lesion, yielding important information that might not be obtainable by other diagnostic aids


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 4 | Pages 635 - 639
1 Jul 1991
Futami T Kasahara Y Suzuki S Ushikubo S Tsuchiya T

We used ultrasonography to examine 36 children suffering from transient synovitis and 12 children with early Perthes' disease. Widening of the joint space was revealed by ultrasonography in all affected hips with either disease. In the patients with transient synovitis, capsular distension was attributed to synovial effusion, while in the patients with Perthes' disease it was produced by thickening of the synovial membrane. Neither capsular distension nor thickening of the joint cartilage was seen in the contralateral normal hip in the patients with transient synovitis, but they were common in early Perthes' disease. Ultrasonography may provide significant diagnostic clues to differentiate early Perthes' from transient synovitis


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 1 - 1
1 May 2017
Malahias M Babis G Kaseta M Chytas D Kazas S Nikolaou V
Full Access

Introduction. We investigated whether grey scale early ultrasonography could be used for the accurate initial diagnosis of non displaced occult scaphoid fractures. Methods. This is a prospective blind clinical study that includes 36 patients that came to the emergency room with suspected clinical symptoms for scaphoid fracture but negative initial X-ray's. After that, a high resolution ultrasonography (without Doppler) was performed. Both wrists of each patient were examined, for comparison. After 14 days, new X-rays were performed, which compared to the early sonographic results of the patients. Results. 25 out of the 36 patients that were included in the study found with subperiosteal hematoma, while 11 of them had also cortical discontinuity. Besides, follow-up X-rays were diagnostic of fracture in 22 patients. 7 patients were ultrasound-positive for fracture but their late X-ray's remained negative, while 4 patients were ultrasound-negative with positive X-ray's. We performed a CT scan on these 11 patients, where we found early ultrasound's sensitivity: 87.5%, specificity: 75%, positive prognostic value: 84% and negative prognostic value: 72%. On the other hand, late X-ray's had sensitivity: 87.5%, specificity: 91%, positive prognostic value: 95% and negative prognostic value: 78% in the detection of occult fractures. Conclusion. The use of early scaphoid ultrasound in the E.R. is valuable in the hands of the orthopaedic surgeon and decongests the radiology department and the national health system from further specific and expensive imaging studies. So, this examination offers the possibility to reduce the time of diagnosis of these occult fractures, so as to provide early and correct treatment. Level of Evidence. II


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 128 - 128
1 Nov 2018
Zadran S Christensen K Petersen T Rasmussen S
Full Access

Acute lateral ankle sprain accounts for 85% of sprains. The lateral sprain is associated with other ligament injuries e.g. medial and syndesmosis sprain. Long-term, approximately 20% of acute lateral sprains develop into chronic lateral ankle instability (CLAI) which includes persistent pain, and recurring ankle sprains. This study evaluated the grade of an ankle ligament injury by ultrasonography (US) and compared the findings to the outcome of patient-reported questionnaires. 48 subjects (18–40 years) diagnosed with an ankle sprain attended a clinical and US examination of ankle ligaments within two weeks after the sprain. Evaluation was done by US of acute lateral ligament injuries (ATFL, CFL), syndesmosis injury (AiTFL), and medial injury (dPT, TCt) only in participants with the positive clinical signs of medial injury. Participants were then mailed a questionnaire (PROMQ) every third month for a year. 29 women and 19 men participated with a mean age at 26.50 years. One-year follow-ups need to be analyzed further for final results. Temporary results include data based on the initial 26 patients: Two clinical signs statistically correlated. Multiple logistic regression analysis confirmed the results. Positive palpated tenderness AiTFL predicted with partial ruptured ATFL and reported pain during active plantar flexion of ankle predicted with normal CFL confirmed by the US. Patients with partial rupture of ATFL presented with tenderness at AiTFL point. Patients presenting with intact CFL reported pain during active plantar flexion. Compared to the US findings, the overall examinations were inconclusive in predicting ATFL, CFL, AiTFL, and medial ligament injuries


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 321 - 324
1 Mar 1998
Bar-On E Meyer S Harati G Porat S

Ultrasonography of the hip was performed sequentially by two different examiners in 75 infants. The ultrasound strips were reviewed twice by three paediatric orthopaedic surgeons and classified by the Graf method. The intraobserver and interobserver agreement between the interpretations was analysed using simple and weighted kappa coefficients calculated for agreement on the Graf classification and for grouping as normal (types 1A to 2A), and abnormal requiring treatment (types 2B to 4). When examining the same ultrasound strip, intraobserver agreement for the Graf classification was substantial (mean kappa 0.61), but interobserver agreement was only moderate (kappa 0.50). For the grouping into normal and abnormal, the mean kappa value for intraobserver agreement was 0.67 and for interobserver agreement 0.57. Because of the significant differences in agreement between normal and abnormal hips, we analysed a subgroup of those with at least one abnormal interpretation. Intraobserver agreement within this subgroup showed moderate reliability (kappa 0.41), but interobserver agreement was only fair (kappa 0.28). Interpretations of two different strips performed sequentially showed significantly lower agreement with an intraobserver kappa value of 0.29 and an interobserver value of 0.28. In the subgroup with at least one abnormal reading, the intraobserver kappa was 0.09 and the interobserver 0.1. Our findings suggest that both the technique of performing ultrasonography and the interpretation of the image may influence the result


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 6 | Pages 884 - 889
1 Nov 1991
Kallio P Lequesne G Paterson D Foster B Jones

We used ultrasonography to study 26 hips with slipped capital femoral epiphyses. In recently slipped epiphyses the ultrasound image revealed a step at the anterior physeal outline (mean 6.4 mm), diminished distance between the anterior acetabular rim and the femoral metaphysis (mean 4.3 mm) and an effusion. As metaphyseal remodelling progressed the physeal step decreased. The femoral neck appeared straighter in hips which had been symptomatic for longer than three weeks. It was possible to measure posterior epiphyseal displacement without projectional errors and the method was accurate in diagnosing minimal slip and in staging displacement. The suggested criteria are, less than 7 mm for a mild slip, 7 to 11 mm for a moderate slip and more than 11 mm for a severe slip. We recommend ultrasonography for the diagnosis, staging and follow-up management of slipped upper femoral epiphysis


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 112 - 112
1 Jul 2002
Hansson G Aurell Y
Full Access

The value of ultrasonography (US) was assessed for studying the position of the navicular and the cuboid in children with clubfeet (CF). In most studies on the management of CF, more than 50% of the patients have required surgical treatment for correcting foot deformities. In addition, repeat surgery is commonly needed for correction of residual foot deformities, especially persistent forefoot adduction usually due to medial displacement of the navicular and sometimes also the cuboid. These conditions have often been overlooked at the initial surgery. The authors examined 50 CF and 100 normal feet by US in children during the first year of life. With the transducer, the position of the navicular was studied along the medial border of the foot, and the position of the cuboid along the lateral border of the foot. The results indicated that 1) Severe medial displacement of the navicular towards the medial malleolus, which might not be possible to reveal by clinical examination, was commonly seen in children with CF and 2) severe medial displacement of the cuboid was seen considerably less frequently. Ultrasonography, using the most recent type of equipment, is a helpful tool when deciding if the navicular and the cuboid need to be re-aligned by open reduction in children with CF during the first year of life


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 383 - 383
1 Sep 2005
Sadun A Milgrom C Bloom R Jaber S
Full Access

Introduction The accuracy of ultrasonography has been reported to be high in diagnosing full thickness rotator cuff tears if measurements are made in both in the coronal and sagital planes. The purpose of this study is to determine how well pre-operative shoulder ultrasound rotator tear measurements when performed only in the coronal plane, the common practice in Israel, predicts the intra-operative surgical findings. Materials and Methods Fifty consecutive patients who underwent open rotator cuff repairs were included in the study. All patients underwent a pre-operative ultrasound by the same experienced musculoskeletal ultrasoundist. Rotator cuff tears were measured in the coronal plane only. This was compared with the tear size measured intra-operatively. Regression analysis was done between the two variables. Results The mean size of rotator cuff tears as determined by ultrasonography was 15.56±8.07mm and the measure size of the tears intraoperatively was 27.94±9.8 mm. The result of the regression analysis of the two variables was R2= 0.268405 for the first 25 patients and R2= 0.310309 for the second 25 patients. Discussion Using ultrasound it is easy to visualize the extent of rotator tears in the coronal plane, but more time consuming to measure the extent in the sagital plane, where the tear may have its greatest extension. Ultrasound measurements tear measurements in this study, made only in the coronal plane correlated poorly with intraoperative findings and only minimally improved over the time course of the study. Conclusion Proper assessment of a possible candidate for a rotator cuff repair should include an ultrasound with the tear size measured specifically in both the coronal and sagital planes


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 139 - 144
1 Jan 2017
Maranho DA Leonardo FHL Herrero CF Engel EE Volpon JB Nogueira-Barbosa MH

Aims. Our aim was to describe the mid-term appearances of the repair process of the Achilles tendon after tenotomy in children with a clubfoot treated using the Ponseti method. Patients and Methods. A total of 15 children (ten boys, five girls) with idiopathic clubfoot were evaluated at a mean of 6.8 years (5.4 to 8.1) after complete percutaneous division of the Achilles tendon. The contour and subjective thickness of the tendon were recorded, and superficial defects and its strength were assessed clinically. The echogenicity, texture, thickness, peritendinous irregularities and potential for deformation of the tendon were evaluated by ultrasonography. Results. The appearance of the Achilles tendon was slightly abnormal, with more thickening and less conspicuous contours than a normal tendon. Its strength was grossly normal, with no insufficiency of the triceps surae. Ultrasonographic findings revealed a mild fusiform thickening in 12 children (80%). The tissue at the site of the repair had a slightly hypoechoic, fibrillar quality with hyperechoic striation and the anterior contour was irregular and blurred. There was a focal narrowing within the healing tissue in two children. Conclusion. This mid-term evaluation of the ability of the Achilles tendon to repair after division suggests a combination of intrinsic and extrinsic mechanisms. There were minor abnormalities which did not appear to affect function. Cite this article: Bone Joint J 2017;99-B:139–44


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 358 - 364
1 May 1993
Eyres K Bell M Kanis J

We studied the quantity and rate of formation of new bone during lengthening of 17 limb segments in 10 patients using dual-energy X-ray absorptiometry (DEXA), ultrasonography and radiography. Whereas new bone was detected by both DEXA and ultrasonography within 1 to 2 weeks of distraction, it was not visible on the radiographs until 4 to 8 weeks. Limb alignment and gap measurement were accurately assessed by DEXA without the need for standard radiographs or scanograms. With ultrasound the distraction gap appeared as an echolucent window which narrowed progressively producing a hyper-reflecting line after which further consolidation could not be assessed. As measured by DEXA the density of the new bone at this stage was approximately 45% of control values and did not represent normal cortication. Whereas ultrasound could be used to identify defects in mineralisation and to determine when to dynamise the fixator system, DEXA could measure the quantity and rate of formation of bone throughout lengthening


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 330 - 330
1 Jul 2008
Martin DJ Patil S Byrne D Leach WJ
Full Access

Aim: We have carried out a prospective study to compare duplex ultrasonography and transcutaneous oxygen tension as predictors of wound healing after knee arthroplasty. Methods and Materials: 53 patients were included in the study. All underwent pre-operative duplex scans of their lower limbs. In addition, transcutaneous oxygen tension measurements were made adjacent to the proposed incision pre-operatively and on days 1, 3 and 7 post knee arthroplasty. Wound healing was assessed using the ASEPSIS wound score. Results: 4 wounds had evidence of delayed wound healing. Duplex ultrasonography was a poor predictor of such problems; however there was a significant correlation between pre-operative transcutaneous oxygen tension and post-operative wound scores. Conclusion: Pre-operative transcutaneous oxygen tension measurement is a better predictor of wound healing after knee replacement surgery than duplex ultrasonograph, and may be a useful adjunct to the investigation of patients at risk of wound problems post knee arthroplasty


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 16 - 16
1 May 2016
Sato A Takagi H Asai S
Full Access

Total knee arthroplasty (TKA) is one of the most successful surgeries to relieve pain and dysfunction caused by severe arthritis of the knee. Despite developments in prophylactic methods, deep venous thrombosis (DVT) and pulmonary embolism (PE) continue to be a serious complication following TKA. Otherwise DVT/PE is known to be a relatively low incidence in Asian patients, its accurate incidence is still controversial. Therefore, we prospectively investigated the incidence of DVT/PE after primary TKA by contrast enhanced computed tomography (CE-CT) and venous ultrasonography (US) in Japanese Patients. Methods. We prospectively investigated 51 patients who underwent primary TKA at the hospital from July 2013 to December 2013. All were of Japanese ethnicity. The mean age at the surgery was 74.9 years and average BMI was 26.0. There were 45 (88.2%) cases of osteoarthritis and 5 (9.8%) of rheumatoid arthritis. A single knee surgery team performed all operations with cemented type prostheses by utilizing pneumatic tourniquet. There were 21 cases of one-staged bilateral TKA and 30 of unilateral TKA. All patients were applied intermittent pneumatic compression (IPC) until 24 hours and graduated compression stockings for 3[高木1] weeks after the operation. Beginning from the day after the surgery, the patients were allowed walking with walker, along with the gradual range of motion exercise for physical thromboprophylaxis. Low-dose unfractionated heparin (LDUH) as a chemical thromboprophylaxis was administered subcutaneously for 3 days after the surgery. Informed consent was obtained regarding this thromboprophylaxis protocol. CE-CT and venous US were performed at the 4th day after surgery and images were read by a single senior radiologist team. The patients without DVT/PE by examination, they did not take additional chemical thromboprophylaxis. In cases of existence of DVT, continuous heparin administration and oral warfarin were applied and adjusted in appropriate dose for treatment. Warfarin was continued to be applied for at least three months until the patients had no symptoms and normal D-dimer level. In cases of PE, additional ultrasonic echocardiography (UCG) was performed, and then we consulted cardiologist to treat for PE. Results. CE-CT was performed in 42 patients (82.3%), otherwise nine patients (17.7%) could not take the examination because of exclusion criteria. There was no side-effect regard to contrast medium. The incidence of DVT and/or PE was 32 patients (62.7%), including two PE (3.9%), 21 DVT (41.1%) and nine both PE and DVT (17.6%). Six-teen patients were used LDUH routinely for 3 days after surgery. Five patients were used continuous heparin administration and oral warfarin instead of using LDUH because of medical co-morbidities. Additional continuous heparin administration and oral warfarin after LDUH use was needed in 26 patients. Three patients who had duodenal ulcer with chronic pancreatitis, massive PE with right heart strain and multiple DVT/PE with HIT antibody were needed another treatment. Conclusion. We prospectively investigated 51 patients for DVT/PE after primary TKA using CE-CT and venous US. The incidence of DVT/PE after primary TKA was 62.7%, including 21.5% of PE, as high frequency in Japanese patients


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1252 - 1258
1 Dec 2023
Tanabe H Baba T Ozaki Y Yanagisawa N Homma Y Nagao M Kaneko K Ishijima M

Aims

Lateral femoral cutaneous nerve (LFCN) injury is a potential complication after the direct anterior approach for total hip arthroplasty (DAA-THA). The aim of this study was to determine how the location of the fasciotomy in DAA-THA affects LFCN injury.

Methods

In this trial, 134 patients were randomized into a lateral fasciotomy (n = 67) or a conventional fasciotomy (n = 67) group. This study was a dual-centre, double-blind, prospective randomized controlled two-arm trial with parallel group design and a 1:1 allocation ratio. The primary endpoint was the presence of LFCN injury, which was determined by the presence of numbness, decreased sensation, tingling, jolt-like sensation, or pain over the lateral aspect of the thigh, excluding the surgical scar, using a patient-based questionnaire. The secondary endpoints were patient-reported outcome measures (PROMs) using the Western Ontario and McMaster Universities osteoarthritis index (WOMAC), Japanese Orthopaedic Association Hip Disease Evaluation Questionnaire (JHEQ), and the Forgotten Joint Score-12 (FJS-12). Assessments were obtained three months after surgery.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_III | Pages 257 - 257
1 Mar 2003
Hell Anna K Ruehmann O Peters G Lazovic D
Full Access

Introduction. In Mid-Europe developmental dysplasia of the hip (DDH) is diagnosed using the sonographic hip screening described by Graf. To learn the necessary standards three courses are mandatory. However, little is known about learning curves and measurement errors of doctors at different levels of training and experience. Material and Methods. Between 1997 and 2002 participants of the basic, advanced and final hip ultrasonogra-phy course were evaluated by a questionnaire and 34 normal and pathological sonograms. They were asked to measure the alpha and beta angle. “Normal” angles of each hip were created through the mean values of two experienced course organizers. Results. 186 doctors (40% orthopedic surgeons, 60% pediatricians) were evaluated. The group included 20% interns, 60% residents and 20% consultants. An average time of 6.3 months lay between the basic and the advanced, and of 16.7 months between the advanced and the final course. The evaluation of the sonograms according to Graf showed major inter-observer differences of up to 30°. Participants had more difficulties in evaluating a correct beta angle than an alpha angle. Sonographic pictures of minor quality and pathological hips produced more difficulties than pictures of Graf type I and II hips. In the basic course all measurements showed an average difference of 3,6°, in the advanced course of 3,1° and in the final course of 4,2°. The number of examinations between courses did not correlate with good measurements. Conclusion. Even participants of all three courses seem to develop major systemic errors if ultrasonography is regularly applied without supervision. Therefore, regular training and supervision should be mandatory in order to guarantee good quality


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 354 - 355
1 Mar 2004
Mariconda M Lotti G Longo C Ammendolia A Corrado B Milano C
Full Access

Aims: The purpose of this study is to evaluate the possible utility of a low-cost radiation-free technique for predicting degenerative changes in the lumbar spine. Methods: In 117 patients with low back pain or pain in the lower limb, ultrasonographic parameters (speed of sound, broadband ultrasound attenuation, stiffness) of the calcaneus were correlated with (1) evidence for degenerative changes and stenosis on magnetic resonance scans of the lumbar spine and (2) Oswestry Low Back Pain Disability Questionnaire Score. Linear and logistic regression as well as ROC curves analyses were used to evaluate the correlation. Results: Lumbar spine stenosis was associated with elevated calcaneal ultraso-nographic parameters. For the identiþcation of a narrowing of the lumbar spinal canal below 100mm2 of dural sac crosssectional area, speed of sound showed an 89% sensitivity in males older than 60. In these patients, we also found a signiþcant positive correlation between ultrasonographic parameters and scores on a MRI-based degenerative scale. No signiþcant correlation was found between disability score and lumbar spine degeneration or ultrasonographic parameters. Conclusions: Calcaneal ultrasonography is frequently used as a diagnostic test for osteoporosis. Its values are highly correlated with lumbar spine stenosis in elderly symptomatic males, and this low-cost radiation-free diagnostic method can be used to identify those patients needing more extensive diagnostic testing


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 327 - 327
1 May 2006
Martínez J Ríos J Martínez F Martínez-Almagro A
Full Access

Introduction and purpose: Our aim was to determine a morphometric relation between the long head of the brachial biceps and the bicipital groove with respect to the subscapular tendon, and its repercussion on functional imbalance of the shoulder. Materials and methods: For this analytical observational crossover study we took a sample of 30 right-handed, sedentary, duly informed male subjects. The morphometric study was carried out with ultrasonography using a cross-section of the long head of the brachial biceps. Results: In the dominant limb: 1. Bicipital groove (depth 2.6 mm, width 13.4 mm, internal angle 149.8°); 2. Long head of the brachial biceps (area 1.35 mm, internal angle 152.53°, echogenicity 97.95); 3. Subscapular thickness 4.53 mm. In the non-dominant limb: 1. Bicipital groove (depth 2.9 mm, width 12.5 mm, internal angle 145.73°); 2. Long head of the brachial biceps (area 1.07 mm, internal angle 141.32°, echogenicity 112.72); 3. Subscapular thickness 4.12 mm. Conclusions: The greater the thickness of the subscapular tendon: 1. Bicipital groove (greater width and internal angle, less echogenicity and depth); 2. Long head of the brachial biceps (greater area and internal angle, less echogenicity). Therefore, there is a greater risk of dislocation of the long head of the brachial biceps and functional instability of the shoulder


Previous investigations have postulated that the asymmetry of the breasts in female adolescents may be linked with the development of right convex thoracic scoliosis, although there is no correlation between breast asymmetry and curve type or scoliosis magnitude. This breast asymmetry is supposed to be linked with anatomic and functional asymmetry of the internal mammary artery that is the main supplier to the mammary gland. However, no measurements of anatomic and haemodynamic parameters of internal mammary artery have been made to justify or to reject the hypothesis of asymmetric blood flow volume to the breasts and costosternal junction in female adolescent scoliotics. Twenty female adolescents with right thoracic scoliosis and 16 comparable female individuals without spine deformity were included in this study. Standing roentgenograms of the whole spine were made in all scoliotics to measure scoliosis curve, vertebral rotation and concave and convex rib-vertebra-angle at three vertebrae (apical, one level above and one below the apical vertebra). The Color Doppler Ultrasonography was used to measure at the origin of internal mammary artery its lumen diameter, cross sectional area, time average mean flow and flow volume per minute in scoliotics and controls and were compared each other. The roentgenographic parameters were compared with the ultrasonographic parameters in the scoliotics to disclose any relationship. The reliability of color Doppler ultrasonography was high and the intraobserver variability low (ANOVA, P=0.92–0.94). There was no statistically significant difference in the ultrasonographic parameters of the internal mammary artery between right and left side in each individual as well as between scoliotics and controls. In scoliotics the right mammary artery time average mean velocity increases with the convex and concave rib-vertebra-angle one level above the apical vertebrae (P< 0.01), convex rib-vertebra angle one level below the apical vertebra (P< 0.05), and concave apical rib-vertebra angle (P< 0.01). The left internal mammary artery time average increases with only the convex rib-vertebra angle one level above the apical vertebra (P< 0.05). The right and left internal mammary artery flow volume increases with the convex rib-vertebra-angle one level above the apical vertebra (P< 0.05), while the right internal mammary artery flow volume increases furthermore with the apical concave rib-vertebra-angle (P< 0.01) and concave rib-vertebra angle one level above the apical vertebra (P< 0.01). The concave apical rib-vertebra-angle (P< 0.01) and concave rib-vertebra-angle one level above the apical vertebra (P< 0.01) increases with left internal mammary artery cross sectional area. We concluded that anatomic and haemodynamic flow parameters measured at the origin of internal mammary artery are significantly correlated with apical rib-vertebra-angle in female adolescents suffering from right convex idiopathic thoracic scoliosis. This study did not find any evidence for side-difference in vascularity of the anterior thorax wall thus could not justify previous theories for development of right thoracic scoliosis in female adolescents