Cranio-cervical connection is a well-established biomechanical concept. However, literature of this connection and its impact on cervical alignment is scarce. Chin incidence (CI) is defined as a complementary to the angle between chin
Femoral neck fractures account for half of all hip fractures and are recognized as a major public health problem associated with a high socioeconomic burden. Whilst internal fixation is preferred over arthroplasty for physiologically younger patients, no consensus exists about the optimal fixation device yet. The recently introduced implant Femoral Neck System (FNS) (DePuy Synthes, Zuchwil, Switzerland) was developed for dynamic fixation of femoral neck fractures and provides angular stability in combination with a minimally invasive surgical technique. Alternatively, the Hansson Pin System (HPS) (Swemac, Linköping, Sweden) exploits the advantages of internal buttressing. However, the obligate peripheral placement of the pins, adjacent to either the inferior or posterior cortex, renders the instrumentation more challenging. The aim of this study was to evaluate the biomechanical performance of FNS versus HPS in a Pauwels II femoral neck fracture model with simulated posterior comminution. Forty-degree Pauwels II femoral neck fractures AO 31-B2.1 with 15° posterior wedge were simulated in fourteen paired fresh-frozen human cadaveric femora, followed by instrumentation with either FNS or HPS in pair-matched fashion. Implant positioning was quantified by measuring the shortest distances between implant and inferior cortex (DI) as well as posterior cortex (DP) on anteroposterior and axial X-rays, respectively. Biomechanical testing was performed in 20° adduction and 10° flexion of the specimens in a novel setup with simulated iliopsoas muscle tension. Progressively increasing cyclic loading was applied until construct failure. Interfragmentary femoral head-to-shaft movements, namely varus deformation, dorsal
Adult Spine Deformity (ASD) is a degenerative condition of the adult spine leading to altered spine curvatures and mechanical balance. Computational approaches, like Finite Element (FE) Models have been proposed to explore the etiology or the treatment of ASD, through biomechanical simulations. However, while the personalization of the models is a cornerstone, personalized FE models are cumbersome to generate. To cover this need, we share a virtual cohort of 16807 thoracolumbar spine FE models with different spine morphologies, presented in an online user-interface platform (SpineView). To generate these models, EOS images are used, and 3D surface spine models are reconstructed. Then, a Statistical Shape Model (SSM), is built, to further adapt a FE structured mesh template for both the bone and the soft tissues of the spine, through mesh morphing. Eventually, the SSM deformation fields allow the personalization of the mean structured FE model, leading to generate FE meshes of thoracolumbar spines with different morphologies. Models can be selectively viewed and downloaded through SpineView, according to personalized user requests of specific morphologies characterized by the geometrical parameters: Pelvic Incidence; Pelvic Tilt; Sacral Slope; Lumbar Lordosis; Global
Several emerging reports suggest an important involvement of the hindfoot alignment in the outcome of knee osteotomy. At present, studies lack a comprehensive overview. Therefore, we aimed to systematically review all biomechanical and clinical studies investigating the role of the hindfoot alignment in the setting of osteotomies around the knee. A systematic literature search was conducted on multiple databases combining “knee osteotomy” and “hindfoot/ankle alignment” search terms. Articles were screened and included according to the PRISMA guidelines. A quality assessment was conducted using the Quality Appraisal for Cadaveric Studies (QUACS) - and modified methodologic index for non-randomized studies (MINORS) scales. Three cadaveric, fourteen retrospective cohort and two case-control studies were eligible for review. Biomechanical hindfoot characteristics were positively affected (n=4), except in rigid subtalar joint (n=1) or talar
Biomedical imaging is essential in the diagnosis of musculoskeletal pathologies and postoperative evaluations. In this context, Cone-Beam technology-based Computed Tomography (CBCT) can make important contributions in orthopaedics. CBCT relies on divergent cone X-rays on the whole field of view and a rotating source-detector element to generate three-dimensional (3D) volumes. For the lower limb, they can allow acquisitions under real loading conditions, taking the name Weight-Bearing CBCT (WB-CBCT). Assessments at the foot, ankle, knee, and at the upper limb, can benefit from it in situations where loading is critical to understanding the interactions between anatomical structures. The present study reports 4 recent applications using WB-CBCT in an orthopaedic centre. Patient scans by WB-CBCT were collected for examinations of the lower limb in monopodal standing position. An initial volumetric reconstruction is obtained, and the DICOM file is segmented to obtain 3D bone models. A reference frame is then established on each bone model by virtual landmark palpation or principal component analysis. Based on the variance of the model point cloud, this analysis automatically calculates longitudinal, vertical and mid-lateral axes. Using the defined references, absolute or relative orientations of the bones can be calculated in 3D. In 19 diabetic patients, 3D reconstructed bone models of the foot under load were combined with plantar pressure measurement. Significant correlations were found between bone orientations, heights above the ground, and pressure values, revealing anatomic areas potentially prone to ulceration. In 4 patients enrolled for total ankle arthroplasty, preoperative 3D reconstructions were used for prosthetic design customization, allowing prosthesis-bone mismatch to be minimized. 20 knees with femoral ligament reconstruction were acquired with WB-CBCT and standard CT (in unloading). Bone reconstructions were used to assess congruency angle and patellar
A risk factor for patellofemoral instability is trochlear dysplasia. Trochleoplasty is a surgical procedure used to reshape the trochlear groove to improve patellar stability. This study seeks to compare pre-op MRI measurements and post operative MRI measurements for patients who have undergone trochleoplasty in correlation with their clinical outcomes scores. Data was collected from a database of patients known to have trochlear dysplasia who underwent trochleoplasty. Radiological Data was collected pre-op and subsequent post op MRI data collected included TT-TG, Patella
Introduction and Objective. It is widely accepted that interfragmentary strain stimulus promotes callus formation during secondary bone healing. However, the impact of the temporal variation of mechanical stimulation on fracture healing is still not well understood. Moreover, the minimum strain value that initiates callus formation is unknown. The goal of this study was to develop an active fixation system that allows for in vivo testing of varying temporal distribution of mechanical stimulation and that enables detection of the strain limit that initiates callus formation. Materials and Methods. We employed a previously established wedge defect model at the sheep tibia. The model incorporates two partial osteotomies directed perpendicularly to each other, thus creating a bone fragment in the shape of a wedge. The defect was instrumented with an active fixator that
Objectives. There are various pin-in-plaster methods for treating fractures
of the distal radius. The purpose of this study is to introduce
a modified technique of ‘pin in plaster’. Methods. Fifty-four patients with fractures of the distal radius were
followed for one year post-operatively. Patients were excluded if
they had type B fractures according to AO classification, multiple
injuries or pathological fractures, and were treated more than seven
days after injury. Range of movement and functional results were
evaluated at three and six months and one and two years post-operatively.
Radiographic parameters including radial inclination,
The CCI mobile bearing ankle implant used at our orthopedic department 2010–2013, was abandoned due to failures and findings of bone loss at revision. The aim of this study was to a) Determine our true revision rate, b) Investigate accuracy of measuring prevalence, size and location of periprosthetic bone cysts through X-ray and CT and c) Relate these findings to implant alignment and patient reported outcome measurements (PROMs). 51 primary surgeries were performed, prior to this study 8 had been revised. Out of 43 un-revised patients, 36 were enrolled and underwent evaluation with metal artefact reduction CT-scans and conventional X-ray. They filled out 3 PROMs; SEFAS, SF-12, EQ-5D. Cyst volume larger than 0.1 ml was measured using VITREA volume tools for CT-scans and calculation of spherical volume for X-rays; using AP- and lateral projections. Location of lesions was recorded, according to their position relative to the implant. Medial-/lateral- and anterior-/posterior
Limited information is published regarding the activity level after gracilis autograft reconstruction, and usually a knee-injury based score is used rather than a specific ankle PROM. The purpose of this study was to investigate the activity level and functional results after lateral ankle gracilis autograft reconstruction in patients with severe lateral ankle instability. The hypothesis was that patients would regain their pre-injury Tegner activity level or one level below and secondary to compare a specific ankle activity score, instability and function score. Finally, donor site and graft complications, clinical stability and range of motion were measured. All 69 patients (50 women, 19 men) recorded at the hospital with severe instability who underwent reconstruction of the anterior talofibular and the calcaneofibular ligament with a gracilis autograft and were minimum 6 months post-operative, were invited to participate in the study. Outcomes measures included the Tegner Activity level (1–10), Ankle Activity Score (0–10) recorded as pre-injury and at follow up. The Karlsson Petterson Ankle Function Score (0–100) and Visual Analog Score (VAS)(0–10) recorded pre-operatively and at follow up. All pre-injury and pre-operative data were recalled retrospectively from memory. Identification of functional ankle instability (IDFAI)(0–37) was recorded at follow up. The clinical tests, Anterior drawer test (0–4), Talar
Abstract. Optical motion capture (OMC) is the current gold standard for motion analysis, however measuring patellofemoral kinematics is not possible using the technique. One approach to measuring in-vivo kinematics is to use biplane video X-ray (BVX) and 3D models generated from MRI to track the movement of the patellar. Understanding how the patellar is moving during different loaded dynamic activities can help with understanding the effects of different interventions when treating disease or injury. Objective. To develop a protocol and compare patellofemoral kinematics for different activities using biplane video X-ray (BVX). Methods. Two healthy volunteers performed level walk, lunge, and stair ascent activities while simultaneous capturing BVX and synchronised OMC. Participants undertook MR imaging (Magnetom 3T Prisma, Siemens) which was manually segmented into 3D bone models (Simpleware Scan IP, Synopsis). Bone position and orientation for the patellar and femur were calculated by manual matching of 3D Bone models to X-Rays (DSX Suite, C-Motion, Inc.). Patellofemoral kinematics were calculated using Visual 3D (C-Motion, Inc.). Results. Initial results show that patellar flexion(+) (PF) was greatest during lunge (52.1º) compared with stair ascent (49.4º) and stance phase of gait (5.4º), however stair ascent had the largest PF range of motion (ROM) of 48.8º. The lunge activity had the greatest ROM for patellar lateral rotation (12.8º) compared with stair ascent (8.7º) and gait (3.7º). Patellar lateral (+)
Surgical treatment of fragility sacrum fractures with percutaneous sacroiliac (SI) screw fixation is associated with high failure rates in terms of screw loosening, cut-through and turn-out. The latter is a common cause for complications, being detected in up to 20% of the patients. The aim of this study was to develop a new screw-in-screw concept and prototype implant for fragility sacrum fracture fixation and test it biomechanically versus transsacral and SI screw fixations. Twenty-seven artificial pelves with discontinued symphysis and a vertical osteotomy in zone 1 after Denis were assigned to three groups (n = 9) for implantation of their right sites with either an SI screw, the new screw-in-screw implant, or a transsacral screw. All specimens were biomechanically tested to failure in upright position with the right ilium constrained. Validated setup and test protocol were used for complex axial and torsional loading, applied through the S1 vertebral body. Interfragmentary movements were captured via optical motion tracking. Screw motions in the bone were evaluated by means of triggered anteroposterior X-rays. Interfragmentary movements and implant motions in terms of pull-out, cut-through,
Summary Statement. We measured scapulothoracic motions during humeral abduction with different humeral rotations in healthy subjects and whole cadaver models and clarified that humeral rotation significantly influenced scapular kinematics. Introduction. Scapular dyskinesis has been observed in various shoulder disorders such as impingement syndrome or rotator cuff tears. However, the relationship between scapular kinematics and humeral positions remains unclear. We hypothesised that humeral rotation would influence scapular motions during humeral abduction and measured scapular motion relative to the thorax in the healthy subjects and whole cadavers. Methods. Healthy Subjects: Twenty-four shoulders of twelve healthy subjects without shoulder disorders were enrolled. Three electromagnetic sensors were attached on the skin over the sternum, scapula and humerus. Scapular motions during scapular plane abduction (abduction) were measured. The measurements were performed with four hand positions, palm up, thumb up, palm down and thumb down. The elbow was kept extended in all measurements. Each measurement took 5 seconds and repeated three times. Cadavers: Twelve shoulders from 6 fresh whole cadavers were used. A cadaver was set in sitting position on a wooden chair without interrupting scapular motions. Electromagnetic sensors were attached on the thorax, scapula and humerus rigidly with transcortical pins. The elbow was kept in extended position by holding the forearm and the arm was moved passively. The measurements were performed during scapular plane abduction and scapular kinematics were measured in four hand positions, 1: thumb up, 2; palm up, 3; palm down, 4; thumb down as well as the healthy subjects. Each measurement took 5 seconds and repeated three times. Data Analysis: The coordinate system and rotation angles of the thorax, scapula and humerus were decided following ISB recommendation. A one-way analysis of variance was used to test the differences in 4 arm positions. Dunnet's multiple post hoc tests were used to identify the difference between thumb up model (neutral rotation) and other three arm positions. Results. Scapular posterior
Purpose. The purpose of this study is to compare radiographic outcomes of patients treated with dorsal spanning plates with previously reported normal values of radiographic distal radius anatomy and compare the results to prior publications for both external fixation and internal fixation with volar locked plates. Methods. Patients with complex distal radius fractures including dorsal marginal impaction pattern necessitating dorsal distraction plating at the discretion of the senior authors (MAT and MAI) from 5/30/2013 to 12/29/2015 were identified and included in the study. Retrospective chart and radiograph review was performed on nineteen patients, eleven male and eight female, with mean age of 47.83 years (22–82). No patients were excluded from the study. Results. All fractures united prior to plate removal. The average time the plate was in place was 80.5 days (49–129). Follow up radiographs showed average radial inclination of 20.5° (13.2°–25.5°), radial height of 10.7mm (7.5mm–14mm), ulnar variance of −0.3mm (−2.1mm–3.1mm), and volar
Purpose. Addressing posterior tibial plateau fractures is increasingly recognized as an important prognostic factor for functional outcome. The treatment of posterior tibial plateau fractures is rather demanding and the implants are still standard, off-the-shelf implants. This emphasizes the need for a more thorough morphological study of the posterior tibial plateau, in order to treat these posterior fractures more adequately. We aimed to demonstrate anatomical variations of the tibia in order to develop better implants. Method. After approval of the ethical committee 22 historically available CT scans of intact left tibia”s were segmented using Mimics (Materialise, Belgium). In order to perform principal component analysis, corresponding meshes are necessary. Mesh correspondence was achieved by deforming one selected source tibia to every other target tibia, through non rigid registration. The non-rigid registration algorithm was based on the algorithm described by Amberg et al (ref). After performing the non-rigid registration, principal component analysis was performed in Matlab (Mathworks, USA). Results. The first 3 components account for 98,1% of the anatomical shape variation of the tibia. The first principal component accounts for 95,4, the second accounts for 1,6% and the third component accounts for the remaining 1,1% of variation. In the first principal component the most marked variation was the length and the shaft width. Shorter tibia”s have a steeper and more angled posterior medial and lateral plateau as where longer tibia”s have a more rounded posterior tibia plateau. On the distal end, the tip of the medial malleolus is more prominent in shorter tibia”s than in longer tibia”s. The orientation of the tibiofibular joint is directed more posteriorly in larger tibias where it is orientated more laterally in smaller tibia”s. The slope of the medial and lateral tibia plateau is not related to the length or width of the plateau. The second principal component shows a relationship between a valgus shaped tibia shaft and its relation to a relatively smaller medial plateau”s compared with straight tibia”s of the same length. Valgus shaped, small tibia shafts have more posteriorly
Background. Trabecular metal (TM) cones are designed to fill up major bone defects in total knee arthroplasty. Tibial components can be implanted in combination with a stem, but it is unclear if this is necessary after reconstruction with a TM cone. Implanting a stem may give extra stability, but may also have negative side-effects. Aim of this study was to investigate stability and strain distribution of a tibial plateau reconstruction with a TM cone while the tibal component is implanted with and without a stem, and whether prosthetic stability was influenced by bone mineral density (BMD). Methods. Tibial revision arthroplasties were performed after reconstruction of an AORI 2B bone defect with TM cones. Plateaus were implanted in seven pairs of cadaveric tibiae; of each pair, one was implanted with and the other without stem. All specimens were loaded to one bodyweight alternating between the medial and lateral tibia plateau. Implant-bone micro motions, bone strains, BMD and correlations were measured and/or calculated. Results. Tibial components without a stem showed only more varus
Dual mobility (DM) bearing implants reduce the incidence of dislocation following total hip arthroplasty (THA) and as such they are used for the treatment of hip instability in both primary and revision cases. The aim of this study was to compare lower limb muscle activity of patients who underwent a total hip arthroplasty (THA) with a dual mobility (DM) or a common cup (CC) bearing compared to healthy controls (CON) during a sit to stand task. A total of 21 patients (12 DM, 9 CC) and 12 CON were recruited from the local Hospital. The patients who volunteered for the study were randomly assigned to either a DM or a CC cementless THA after receiving informed consent. All surgeries were performed by the same surgeon using the direct anterior approach. Participants underwent electromyography (EMG) and motion analysis while completing a sit-to-stand task. Portable wireless surface EMG probes were placed on the vastus lateralis, rectus femoris, biceps femoris, semitendinosus (ST), gluteus medius and tensor fasciae latae muscles of the affected limb in the surgical groups and the dominant limb in the CON group. Motion capture was used to record lower limb kinematics and kinetics. Muscle strength was recorded using a hand-held dynamometer during maximal voluntary isometric contraction (MVIC) testing. Peak linear envelope (peakLE) and total muscle activity (iEMG) were extrapolated and normalized to the MVIC and time cycle for the sit to stand task. Using iEMG, quadriceps-hamstrings muscle co-activation index was calculated for the task. Nonparametric Kruskal Wallace ANOVA tests and Wilcoxon rank sum tests were used to identify where significant (p < 0.05) differences occurred. The DM group had greater iEMG of the ST muscle compared to the CC (p=0.045) and the CON (p=0.015) groups. The CC group had lower iEMG for hamstring muscles compared to the DM (p=0.041) group. The DM group showed lower quadriceps-hamstrings co-activation index compared to the CON group and it approached significance (p=0.054). The CC group had greater anterior pelvis
Total knee arthroplasty (TKA) is a common orthopaedic procedure with over 1,500 done in 2016 in Ireland alone. 96% of all TKAs are due to pain in the knee associated with osteoarthritis. According to the UK National Joint Registry (NJR), there is a 0.47%, 1.81%, 2.63% and 4.34% probability risk of undergoing a revision TKA within one, three, five and ten years respectively post-index surgery. A variety of reasons for failure of TKA have been described in the literature including infection, aseptic loosening, pain, instability, implant wear, mal-alignment, osteolysis, dislocation, peri-prosthetic fracture and implant fracture. The NexGen Posterior Stabilised Fixed has NJR revision rates of 0.44%, 1.61% and 2.54% at years one, three and five respectively. A retrospective review was carried out of 350 NexGen TKAs that were performed directly by, or under the supervision of, a fellowship trained arthroplasty surgeon in a dedicated orthopaedic hospital between April 2013 and December 2015. 26 (7.4%) of these were revised as of 31 December 2017. Three were for septic arthritis with the remaining 23 (6.6%) for aseptic loosening. Patients typically started to experience symptoms of medial tibial pain with supra-patellar swelling from a combination of effusion and synovial thickening at 12–24 months. Inflammatory markers were normal in all cases. Radiographs of symptomatic knee replacements showed bone loss on the medial tibia with a
Background. Complications such as dislocations, impingement and early wear following total hip arthroplasty (THA) increase with acetabular cup implant malorientation. These errors are more common with low-volume centres or in novice hands. Currently, this skill is most commonly taught during real surgery with an expert trainer, but simulated training may offer a safer and more accessible solution. This study investigated if a novel MicronTracker® enhanced Microsoft HoloLens® augmented reality (EAR) headset was as effective as one-on-one expert surgeon (ES) training for teaching novice surgeons hip cup orientation skill. Methods. Twenty-four medical students were randomly assigned to EAR or ES training groups. Participants used a modified sawbone/foam pelvis model for hip cup orientation simulation. A validated EAR headset measured the orientation of acetabular cup implants and displayed this in the participant”s field of view. The system calculated the difference between planned and achieved orientation as a solid-angle error. Six different inclination and anteversion combinations, related to hypothetical patient-specific anatomy, were used as target orientations. Learning curves were measured over four sessions, each one week apart. Error in orientations of non-taught angles and during a concealed pelvic tilt were measured to assess translation of skills. A post-test questionnaire was used for qualitative analysis of procedure understanding and participant experience. Results. Novice surgeons of similar experience in both groups performed with a similar error prior to training (ES: 15.7°±6.9°, EAR: 14.2°±7.1°, p>0.05). During training, EAR participants were guided to significantly better orientation errors than ES (ES: 6.0°±3.4°, EAR: 1.1°±0.9°, p<0.001). After four training sessions, the orientation error in both groups significantly reduced (ES: 15.7°±6.9° to 8.2°±4.6°, p<0.001; EAR: 14.2°±7.0° to 9.6°±5.7°, p<0.001). Participants in both groups achieved the same levels of orientation accuracy in non-taught angles and when the pelvis was
Total Shoulder Arthroplasty (TSA) is a solution to fixing shoulder complications and restoring normal shoulder functionality. Shoulder arthritis is one of the common indicators of TSA. Studies suggest that 15% and 7% of the total Rheumatoid Arthritis (RA) and Osteoarthritis (OA) patients respectively, in sub-Saharan Africa, have degenerated shoulders. These patients are implanted with a Total Shoulder Prosthesis (TSP). There are limited literature available on the morphometric features of African shoulders. Previous studies have indicated that differences in shoulder surface geometry of the European and African populations, exists. This study aims at identifying the structural differences of the humeral articulating surfaces between South African and Swiss data sets. The South African data set included the Computerised Tomography (CT) scans of cadavers sourced from the University of Cape Town and the Swiss data set included the cadaver CT scans obtained from the SICAS Medical Image Repository. Sixty reconstructed models of humerus were generated from these scans of 30 (bilateral) healthy cadavers (15 South African and 15 Swiss) using Mimics®. The humeral articulating surfaces were separated from the shaft by performing in-silico surgery using SOLIDWORKS®, according to the guidelines provided orthopaedic surgeons. A Matlab code was generated to determine the superior-inferior (S-I) and the anterior-posterior (A-P) circular diameter and the peak points (PPs) of the articulating surfaces. The PPs were defined as the highest point on the articulating surface, which is most likely to be in contact with the glenoid. The S-I diameter was found to be significantly greater (p<0.01) than the A-P diameter for both the data sets (average difference = 5.02mm). Both the average A-P and S-I diameter for the Swiss data set were significantly larger (p = 0.02 and p = 0.03) than the South African data set by 2.36 mm and 2.70 mm respectively. The PPs were found to lie at an off-set from the origin. in case of the Swiss data set the average PP lie on the superior-posterior (S-P) quadrant and for the South African data set the average PP was found to lie on the anterior-inferior (A-I) quadrant. The A-P variation on the position of PP was highly significant (p = 0.003). The results obtained in this study sheds light on the observed morphological variations between the South African and Swiss data sets. The observed circular diameter values are similar to the literature. The observed results suggest that the average TSP needed for the Swiss data set would have been larger than the ones needed for the South African data set. PP is a novel feature which has not been studied extensively. The fact that the average Swiss data set PP lie in the S-P quadrant might suggest that these humeral heads are more retroverted and superiorly