Advertisement for orthosearch.org.uk
Results 1 - 20 of 205
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 9 - 9
1 Jul 2022
Fleming T Torrie A Murphy T Dodds A Engelke D Curwen C Gosal H Pegrum J
Full Access

Abstract. INTRODUCTION. COVID-19 reduced availability of cross-sectional imaging, prompting the need to clinically justify pre-operative computed tomography (CT) in tibial plateau fractures (TPF). The study purpose was to establish to what extent does a CT alter the pre-operative plan in TPF compared to radiographs. There is a current paucity of evidence assessing its impact on surgical planning. METHODOLOGY. 50 consecutive TPF with preoperative CT were assessed by 4 consultant surgeons. Anonymised radiographs were assessed defining the column classification, planned setup, approach, and fixation technique. At a 1-month interval, randomised matched CT scans were assessed and the same data collected. A tibial plateau disruption score (TPDS) was derived for all 4 quadrants (no injury=0,split=1,split/depression=2 and depression=3). Radiograph and CT TPDS were assessed using an unpaired T-test. RESULTS. 26 female and 24 male patients, mean age 50.3, were included. Mean TPDS on radiographs and CT scans were 2.77 and 3.17 respectively. A significant higher net CT TPDS was observed of 0.4 (95%CI 0.10-0.71)[P=0.0093]. Both radiograph and CT TPDS ANOVA were significant (P<0.0001), showing high intraobserver variability for TPF classification. Fracture apex requiring fixation changed in 34% of cases between the radiographs and CT, whilst set-up and surgical approach changed in 27% and 28.5% of cases respectively. All surgeons agreed no CT was required in only 11 out of 50 cases. CONCLUSION. CT scanning in TPF significantly affects the classification, setup, approach and fixation technique when compared to radiographs alone and can justifiably be requested as part of pre-operative planning


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 861 - 867
1 Jul 2020
Hiranaka T Yoshikawa R Yoshida K Michishita K Nishimura T Nitta S Takashiba K Murray D

Aims. Cementless unicompartmental knee arthroplasty (UKA) has advantages over cemented UKA, including improved fixation, but has a higher risk of tibial plateau fracture, particularly in Japanese patients. The aim of this multicentre study was to determine when cementless tibial components could safely be used in Japanese patients based on the size and shape of the tibia. Methods. The study involved 212 cementless Oxford UKAs which were undertaken in 174 patients in six hospitals. The medial eminence line (MEL), which is a line parallel to the tibial axis passing through the tip of medial intercondylar eminence, was drawn on preoperative radiographs. Knees were classified as having a very overhanging medial tibial condyle if this line passed medial to the medial tibial cortex. They were also classified as very small if a size A/AA tibial component was used. Results. The overall rate of fracture was 8% (17 out of 212 knees). The rate was higher in knees with very overhanging condyles (Odds ratio (OR) 13; p < 0.001) and with very small components (OR 7; p < 0.001). The OR was 21 (p < 0.001) in those with both very overhanging condyles and very small components. In all, 69% of knees (147) had neither very overhanging nor very small components, and the fracture rate in these patients was 1.4% (2 out of 147 knees). Males had a significantly reduced risk of fracture (OR 0.13; p = 0.002), probably because no males required very small components and females were more likely to have very overhanging condyles (OR 3; p = 0.013). 31% of knees (66) were in males and in these the rate of fracture was 1.5% (1 out of 66 knees). Conclusion. The rate of tibial plateau fracture in Japanese patients undergoing cementless UKA is high. We recommend that cemented tibial fixation should be used in Japanese patients who require very small components or have very overhanging condyles, as identified from preoperative radiographs. In the remaining 69% of knees cementless fixation can be used. This approach should result in a low rate of fracture. Cite this article: Bone Joint J 2020;102-B(7):861–867


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1233 - 1236
1 Sep 2005
Gaston P Will EM Keating JF

We assessed the functional outcome following fracture of the tibial plateau in 63 consecutive patients. Fifty-one patients were treated by internal fixation, five by combined internal and external fixation and seven non-operatively. Measurements of joint movement and muscle function were made using a muscle dynamometer at three, six and 12 months following injury. Thirteen patients (21%) had a residual flexion contracture at one year. Only nine (14%) patients achieved normal quadriceps muscle strength at 12 months, while 19 (30%) achieved normal hamstring muscle strength. Recovery was significantly slower in patients older than 40 years of age. We conclude that there is significant impairment of movement and muscle function after fracture of the tibial plateau and that the majority of patients have not fully recovered one year after injury


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 7 | Pages 983 - 988
1 Sep 2003
Satku K Kumar VP Chong SM Thambyah A

The natural history of spontaneous osteonecrosis of the medial tibial plateau remains controversial and incomplete. We have studied 21 patients (aged between 53 and 77 years) with clinical and scintigraphic features of spontaneous osteonecrosis of the medial tibial plateau who were observed prospectively for at least three years (37 months to 8.5 years). The mean duration of follow-up was 5.6 years. The mean duration of symptoms at presentation was 4.7 weeks (3 days to 12 weeks). Radiographs of the affected knee at the first visit were normal in 15 patients and mildly arthritic in six. The characteristic radiographic lesion of osteonecrosis was noted at presentation in five of the mildly arthritic knees and during the evolution of the disease in eight of the radiographically normal knees. During the follow-up, subchondral sclerosis of the affected medial tibial plateau was noted in 16 knees. There are three distinct patterns of outcome: 1) acute extensive collapse of the medial tibial plateau in two knees within three months of onset; 2) rapid progression to varying degrees of osteoarthritis in 12 knees, in eight within a year, in all within two years and deterioration of the pre-existing osteoarthritis in three; and 3) complete resolution in four knees, two of which were normal at presentation and two mildly osteoarthritic. The two patients with acute extensive collapse and three who had rapid progression to severe osteoarthritis required total knee arthroplasty. We conclude that osteonecrosis of the medial tibial plateau progresses in most cases to significant degenerative disease of the knee


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 28 - 37
1 Jan 2024
Gupta S Sadczuk D Riddoch FI Oliver WM Davidson E White TO Keating JF Scott CEH

Aims. This study aims to determine the rate of and risk factors for total knee arthroplasty (TKA) after operative management of tibial plateau fractures (TPFs) in older adults. Methods. This is a retrospective cohort study of 182 displaced TPFs in 180 patients aged ≥ 60 years, over a 12-year period with a minimum follow-up of one year. The mean age was 70.7 years (SD 7.7; 60 to 89), and 139/180 patients (77.2%) were female. Radiological assessment consisted of fracture classification; pre-existing knee osteoarthritis (OA); reduction quality; loss of reduction; and post-traumatic OA. Fracture depression was measured on CT, and the volume of defect estimated as half an oblate spheroid. Operative management, complications, reoperations, and mortality were recorded. Results. Nearly half of the fractures were Schatzker II AO B3.1 fractures (n = 85; 47%). Radiological knee OA was present at fracture in 59/182 TPFs (32.6%). Primary management was fixation in 174 (95.6%) and acute TKA in eight (4.4%). A total of 13 patients underwent late TKA (7.5%), most often within two years. By five years, 21/182 12% (95% confidence interval (CI) 6.0 to 16.7) had required TKA. Larger volume defects of greater depth on CT (median 15.9 mm vs 9.4 mm; p < 0.001) were significantly associated with TKA requirement. CT-measured joint depression of > 12.8 mm was associated with TKA requirement (area under the curve (AUC) 0.766; p = 0.001). Severe joint depression of > 15.5 mm (hazard ratio (HR) 6.15 (95% CI 2.60 to 14.55); p < 0.001) and pre-existing knee OA (HR 2.70 (95% CI 1.14 to 6.37); p = 0.024) were independently associated with TKA requirement. Where patients with severe joint depression of > 15.5 mm were managed with fixation, 11/25 ultimately required TKA. Conclusion. Overall, 12% of patients aged ≥ 60 years underwent TKA within five years of TPF. Severe joint depression and pre-existing knee arthritis were independent risk factors for both post-traumatic OA and TKA. These features should be investigated as potential indications for acute TKA in older adults with TPFs. Cite this article: Bone Joint J 2024;106-B(1):28–37


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1227 - 1232
1 Sep 2005
Brouwer RW Bierma-Zeinstra SMA van Koeveringe AJ Verhaar JAN

Our aim was to compare the degree of patellar descent and alteration in angle of the inclination of the tibial plateau in lateral closing-wedge and medial opening-wedge high tibial osteotomy (HTO) in 51 consecutive patients with osteoarthritis of the medial compartment and varus malalignment. Patellar height was measured by the Insall-Salvati (IS) and the Blackburne-Peel (BP) ratios. The tibial inclination was determined by the Moore-Harvey (MH) method. Multivariate linear regression analysis was used to determine the influence of the type of HTO (closing vs opening wedge) on the post-operative patellar height or tibial inclination. The intra- and interobserver variability of these methods was determined before operation and at follow-up at one year. After an opening-wedge HTO the patellar height was significantly more decreased (mean post-operative difference: IS = 0.15; 95% confidence interval (CI) 0.06 to 0.23; BP = 0.11; 95% CI 0.05 to 0.18) compared with a closing-wedge HTO. The angle of tibial inclination differed significantly (mean post-operative difference MH = −6.40°; 95% CI −8.74 to −4.02) between the two HTO techniques, increasing after opening-wedge HTO and decreasing after closing-wedge HTO. There was no clinically-relevant difference in the intra- and interobserver variability of measurements of patellar height either before or after HTO


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 959 - 964
1 Nov 1998
Scheerlinck T Ng CS Handelberg F Casteleyn PP

We carried out percutaneous, arthroscopically- and fluoroscopically-assisted osteosynthesis of fractures of the tibial plateau in 52 patients, of whom 38 were assessed using the HSS knee score and standing radiographs. We reviewed 31 AO type-B fractures and seven type-C fractures after a mean follow-up of five years (1 to 14). Fixation was achieved using percutaneous screws and/or an external frame; 33 associated intra-articular injuries, diagnosed in 21 out of the 38 patients, were treated arthroscopically. Subjectively, 94.7% of the patients reviewed were satisfied. According to the HSS knee score 78.9% of the results were excellent, 13.2% good, 7.9% fair and none was poor. Narrowing of the joint space was found in 28.9% of the injured and 5.3% of the unaffected knees and axial deviation of 5° to 10° in 15.8% of the injured and 10.5% of the unaffected knees. Of the 52 fractures, reduction was incomplete in one, and in two secondary displacement occurred, of which one required corrective osteotomy. Deep-venous thrombosis occurred in four cases. The technique has proved to be safe but demanding. It facilitates diagnosis and appropriate treatment of associated intra-articular lesions


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 330 - 333
1 Mar 2008
Lankester BJA Cottam HL Pinskerova V Eldridge JDJ Freeman MAR

From a search of MRI reports on knees, 20 patients were identified with evidence of early anteromedial osteoarthritis without any erosion of bone and a control group of patients had an acute rupture of the anterior cruciate ligament. The angle formed between the extension and flexion facets of the tibia, which is known as the extension facet angle, was measured on a sagittal image at the middle of the medial femoral condyle.

The mean extension facet angle in the control group was 14° (3° to 25°) and was unrelated to age (Spearman’s rank coefficient, p = 0.30, r = 0.13). The mean extension facet angle in individuals with MRI evidence of early anteromedial osteoarthritis was 19° (13° to 26°, SD 4°). This difference was significant (Mann-Whitney U test, p < 0.001).

A wide variation in the extension facet angle was found in the normal control knees and an association between an increased extension facet angle and MRI evidence of early anteromedial osteoarthritis. Although a causal link has not been demonstrated, we postulate that a steeper extension facet angle might increase the duration of loading on the extension facet during the stance phase of gait, and that this might initiate failure of the articular cartilage.


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1118 - 1125
4 Oct 2022
Suda Y Hiranaka T Kamenaga T Koide M Fujishiro T Okamoto K Matsumoto T

Aims. A fracture of the medial tibial plateau is a serious complication of Oxford mobile-bearing unicompartmental knee arthroplasty (OUKA). The risk of these fractures is reportedly lower when using components with a longer keel-cortex distance (KCDs). The aim of this study was to examine how slight varus placement of the tibial component might affect the KCDs, and the rate of tibial plateau fracture, in a clinical setting. Methods. This retrospective study included 255 patients who underwent 305 OUKAs with cementless tibial components. There were 52 males and 203 females. Their mean age was 73.1 years (47 to 91), and the mean follow-up was 1.9 years (1.0 to 2.0). In 217 knees in 187 patients in the conventional group, tibial cuts were made orthogonally to the tibial axis. The varus group included 88 knees in 68 patients, and tibial cuts were made slightly varus using a new osteotomy guide. Anterior and posterior KCDs and the origins of fracture lines were assessed using 3D CT scans one week postoperatively. The KCDs and rate of fracture were compared between the two groups. Results. Medial tibial fractures occurred after surgery in 15 patients (15 OUKAs) in the conventional group, but only one patient (one OUKA) had a tibial fracture after surgery in the varus group. This difference was significant (6.9% vs 1.1%; p = 0.029). The mean posterior KCD was significantly shorter in the conventional group (5.0 mm (SD 1.7)) than in the varus group (6.1 mm (SD 2.1); p = 0.002). Conclusion. In OUKA, the distance between the keel and posterior tibial cortex was longer in our patients with slight varus alignment of the tibial component, which seems to decrease the risk of postoperative tibial fracture. Cite this article: Bone Joint J 2022;104-B(10):1118–1125


Bone & Joint Research
Vol. 8, Issue 12 | Pages 593 - 600
1 Dec 2019
Koh Y Lee J Lee H Kim H Chung H Kang K

Aims. Commonly performed unicompartmental knee arthroplasty (UKA) is not designed for the lateral compartment. Additionally, the anatomical medial and lateral tibial plateaus have asymmetrical geometries, with a slightly dished medial plateau and a convex lateral plateau. Therefore, this study aims to investigate the native knee kinematics with respect to the tibial insert design corresponding to the lateral femoral component. Methods. Subject-specific finite element models were developed with tibiofemoral (TF) and patellofemoral joints for one female and four male subjects. Three different TF conformity designs were applied. Flat, convex, and conforming tibial insert designs were applied to the identical femoral component. A deep knee bend was considered as the loading condition, and the kinematic preservation in the native knee was investigated. Results. The convex design, the femoral rollback, and internal rotation were similar to those of the native knee. However, the conforming design showed a significantly decreased femoral rollback and internal rotation compared with that of the native knee (p < 0.05). The flat design showed a significant difference in the femoral rollback; however, there was no difference in the tibial internal rotation compared with that of the native knee. Conclusion. The geometry of the surface of the lateral tibial plateau determined the ability to restore the rotational kinematics of the native knee. Surgeons and implant designers should consider the geometry of the anatomical lateral tibial plateau as an important factor in the restoration of native knee kinematics after lateral UKA. Cite this article: Bone Joint Res 2019;8:593–600


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 61 - 61
1 Jul 2022
Wang D Willinger L Athwal K Williams A Amis A
Full Access

Abstract. Background. Little scientific evidence is available regarding the effect of knee joint line obliquity (JLO). Methods. 10 fresh-frozen human cadaveric knees were axially loaded to 1500 N in a materials testing machine with the joint line tilted 0, 4, 8, and 12 degrees varus and valgus, at 0, and 20 degrees of knee flexion. The mechanical compression axis was aligned to the centre of the tibial plateau. Contact pressures / areas were recorded by sensors inserted between the tibia and femur below the menisci. Changes in relative femoral and tibial position in the coronal plane were obtained by an optical tracking system. Results. medial and lateral JLO caused significant tibiofemoral subluxation and pressure distribution changes. Medial (varus) JLO caused the femur to sublux medially down the coronal slope of the tibial plateau, and vice versa for lateral (valgus) downslopes (P=0.01). Areas of peak pressure moved 12 mm and 8 mm across the medial and lateral condyles, onto the ‘downhill’ meniscus and the ‘uphill’ tibial spine. Changes in JLO had only small effects on maximum contact pressures. Conclusion. A change of JLO during load bearing caused significant mediolateral tibiofemoral subluxation. The femur slid down the slope of the tibial plateau to abut the tibial eminence and also to rest on the downhill meniscus. Clinical Relevance. These results provide important information for understanding the consequences of creating coronal JLO and for clinical practice in terms of osteotomy planning regarding the effect on JLO


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 49 - 49
7 Aug 2023
Murray J Murray E Readioff R Gill H
Full Access

Abstract. INTRODUCTION. To preserve knee function and reduce degenerative, meniscal tears should be repaired where possible. Meniscal wrapping with collagen matrices has shown promising clinical outcome (AAOS meniscal algorithm), however there is limited basic science to support this. AIM. to model the contact pressures on the human tibial plateau beneath a (1) a repaired radial meniscal tear and (2) a wrapped and repaired radial meniscal tear. METHODOLOGY. Complete anterolateral radial tears were formed across 4 lateral human menisci, before repairing with ‘rip-stop’ H sutures using 2mm Arthrex Meniscal Suture tape. This was then repeated with the addition of a ChondroGide collagen matrix wrapping. From this experimental setup a finite element (FE) analysis model was construted. FE models of the two techniques (i) suture alone and (ii) suture and collagen-matrix wrap, were then modelled; bone was linear elastic, articular cartilage was a hyperelastic Yeoh model, and a linear elastic and transversely isotropic material model for the meniscus. The contact areas of the articulating surfaces, meniscus kinematics, and stress distribution around the repair were compared between the two systems. RESULTS. Meniscal suture-tape repair had higher local stresses and strains (σ_max=51 MPa ε_max=25%) around the repair compared to with Collagen wrapping (σ_max=36.6MPa ε_max=15%). Radial displacement and pressure on the meniscal contact surfaces were higher in the suture only repair. CONCLUSION. Collagen-matrix wrapping strengthens the repair, reducing local peak stresses and strains around the suture-tape. This could reduce the chance of suture-tape pull-out and subsequent repair failure


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 43 - 43
7 Aug 2023
Lewis A Bucknall K Davies A Evans A Jones L Triscott J Hutchison A
Full Access

Abstract. Introduction. A lipohaemarthrosis seen on Horizontal beam lateral X-ray in acute knee injury is often considered predictive of an intra-articular fracture requiring further urgent imaging. Methodology. We retrospectively searched a five-year X-ray database for the term “lipohaemarthrosis”. We excluded cases if the report concluded “no lipohaemarthrosis” or “lipohaemarthrosis” AND “fracture”. All remaining cases were reviewed by an Orthopaedic Consultant with a special interest in knee injuries (AD) blinded to the report. X-rays were excluded if a fracture was seen, established osteoarthritic change was present, a pre-existing arthroplasty present or no lipohaemarthrosis present. Remaining cases were then studied for any subsequent Radiological or Orthopaedic surgical procedures. Results. 136 cases were identified and reviewed by an Orthopaedic Consultant. 31 were excluded for no lipohaemarthrosis (n= 11), for degenerative change (n=9), for fracture (n=4), for existing arthroplasty (n=4) and for data errors (n=3). The remaining 105 patients had a mean age of 32, and range 5–90 years. 66 patients underwent further imaging in the form of MRI scan (n=47), CT Scan (n=9) repeat x-rays (n=9) and ultrasound (n=1). 27 fractures were identified. Surgery was performed in 12 cases (11%). Two (2%) urgently (One ACL reconstruction plus meniscus repair, one for ORIF of tibial plateau fracture). Ten (10%) had elective surgery (6 for ACL reconstruction, 2 for ACL reconstruction plus meniscus repair, 2 for loose body removal. Conclusion. The presence of a lipohaemarthrosis on x-ray following acute knee injury was a poor predictor of intra-articular fracture (26%) or need for urgent surgery (2%)


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 37 - 37
7 Aug 2023
Mudiganty S Jayadev C Carrington R Miles J Donaldson J Mcculloch R
Full Access

Abstract. Introduction. Total knee replacement (TKR) in patients with skeletal dysplasia is technically challenging surgery due to deformity, joint contracture, and associated co-morbidities. The aim of this study is to follow up patients with skeletal dysplasia following a TKR. Methodology. We retrospectively reviewed 22 patients with skeletal dysplasia who underwent 31 TKRs at our institution between 2006 and 2022. Clinical notes, operative records and radiographic data were reviewed. Results. Achondroplasia was the most common skeletal dysplasia (8), followed by Chondrodysplasia punctata (7) and Spondyloepiphyseal dysplasia (5). There were fourteen men and eight women with mean age of 51 years (28 to 73). The average height of patients was 1.4 metres (1.16–1.75) and the mean weight was 64.8 Kg (34.3–100). The mean follow up duration was 68.32 months (1–161). Three patients died during follow up. Custom implants were required in twelve patients (38.71%). Custom jigs were utilised in six patients and two patients underwent robotic assisted surgery. Hinged TKR was used in seventeen patients (54.84%), posterior stabilised TKR in nine patients (29.03%), and cruciate retaining TKR in five patients (16.13%). One patient underwent a patella resurfacing for persistent anterior knee pain and another had an intra-operative medial tibial plateau fracture which was managed with fixation. No revisions occurred during the follow up period. Conclusion. Despite the technical challenges and complexity of TKR within this unique patient group, we demonstrate good implant survivorship during the study period. Cross sectional imaging is recommended preoperatively for precise planning and templating


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 15 - 15
1 Oct 2020
Li G Zhou C Rao Z Bedair H
Full Access

Introduction. Medial pivoting motion of the knee has been widely assumed in total knee arthroplasty (TKA) research, but was not consistently observed in recent studies of in vivo knee motion. This study investigated the in vivo motion characters of the knee by analyzing the axial tibial rotation and tibiofemoral articular contact motion during a weightbearing flexion and a treadmill gait. Methods. In vivo kinematics of eight living human knees during a weightbearing flexion and a treadmill gait was determined using a combined MRI and dual fluoroscopic imaging system technique. The axial tibial rotation and the tibiofemoral cartilage contact point motion on both the tibial plateau and femoral condyle surfaces were analyzed. Results. While internal tibial rotation was observed with flexion of the knee during the two activities, larger excursions of the tibiofemoral contact points were measured on the medial femoral condyle surface than on the lateral side during the weightbearing flexion of the knee. The contact point excursions were also larger on the medial tibial plateau surface than on the lateral side during the treadmill gait. The contact points moved anteriorly with flexion and posteriorly with extension of the knee on the medial tibial surface during the gait, that was opposite to the femoral rollback observed during the weightbearing knee flexion. Conclusion. The data indicates that the in-vivo knee motion is activity- and loading-dependent and cannot be described using a single motion character. The knee could potentially rotate with respect to an axis located at the lateral side of the knee and the traditional “medial pivoting” motion character of the knee was not observed in these in-vivo activities. The data could provide important implications for the improvement of TKA designs and implantation techniques that are aimed to restore normal knee function


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 93 - 93
1 Jul 2022
Reddy G Rajput V Singh S Salim M Iqbal S Anand S
Full Access

Abstract. Background. Fracture dislocation of the knee involves disruption of knee ligaments with associated tibial plateau fracture. If these injuries are not evaluated swiftly, can result in a limb-threatening injury. The aim of this study is to look at the clinical outcomes of a single surgeon case series at a major trauma centre. Methods. Prospectively collected data was analysed for a 5-year period. Primary outcome measures used were International Knee Documented Committee (IKDC) score and Knee Injury & Osteoarthritis Outcome Score (KOOS). The secondary outcome measures include Tegner activity scale, knee range of movements and complications. Results. 32 patients were presented with the mean age was 34 years (range 17–74). 14% of patients sustained vascular injury and 19% had common peroneal nerve injury. Priority was given for early total repair/reconstruction with fracture fixation within three weeks where feasible (90% of patients), and if not, a staged approach was adopted. The mean IKDC score was 67 (35–100) & KOOS was 74 (40–100). The mean preoperative Tegner Activity Scale was 6.5 whereas post-operative Tegner Activity Scale was 3.6 The mean flexion achieved postoperative was 115 (90–130). The two common patterns of injuries seen were Anterio-medial rim fractures (52%) with avulsion injuries of posterio-lateral corner structures and posteriomedial plateau fractures with ACL avulsion injuries. The first pattern was commonly associated with vascular and common peroneal nerve injury (90% of patients). Conclusion. To our knowledge, this is the first kind of study to report some fracture patterns that can be associated with particular ligamentous injuries


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 68 - 68
1 Jul 2022
Jamal J Wong P Lane B Wood A Bou-Gharios G Santini A Frostick S Roebuck M
Full Access

Abstract. Introduction. It is increasingly evident that synovium may play a larger role in the aetiology of osteoarthritis. We compared gene expression in whole tissue synovial biopsies from end-stage knee osteoarthritis and knee trauma patients with that of their paired explant cultures to determine how accurately cultured cells represent holistic synovial function. Methodology. Synovial tissue biopsies were taken from 16 arthroplasty patients and 8 tibial plateau fracture patients with no osteoarthritis. Pairs of whole tissue fragments were either immediately immersed in RNAlater Stabilisation Solution at 4o C before transfer to -80o C storage until RNA extraction; or weighed, minced and cultured at 500mg tissues/5ml media in a humidified incubator at 37oC, 5% CO2. After sub-culturing total RNA was extracted using RNAeasy Plus Mini Kit with gDNA removal. Following RT-PCR and quality assessment, cDNA was applied to Affymetrix Clariom D microarray gene chips. Bioinformatics analyses were performed. Results. PCA analysis illustrates the clear separation of expression array data from cultured cells compared with their parental whole tissues and no segregation between cells derived from osteoarthritic or trauma tissues. A differentially expressed gene heat map demonstrated the hierarchical independence of cultured cells from their paired sample parental tissues. The biological pathways enriched by these gene expression differences emphasise the activities of macrophages and lymphocytes lost from culture. Conclusion. Adherent synovial cells grown from different knee pathologies lose the expression patterns characteristic of their originating pathology. Interpretation of data needs caution as the cells are not representative of whole synovium


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 64 - 64
1 Jul 2022
Dayananda K Dalal S Thomas E Chandratreya A Kotwal R
Full Access

Abstract. INTRODUCTION. A paucity of literature exists regarding efficacy of lateral unloader bracing in treatment for pathologies effecting the lateral compartment of the knee. We evaluate patient outcomes following customised lateral unloader bracing (cLUB) in treatment of lateral compartment osteoarthritis (LCOA), lateral tibial plateau fractures (LTPF) and spontaneous osteonecrosis of knee (SONK). METHODS. Institutional study approval was obtained. All patients undergoing cLUB between January 2013 and January 2021 were included, and prospectively followed-up. Visual Analogue Scales (VAS), Oxford Knee Scores (OKS) and Knee Injury and Osteoarthritis Outcome Scores (KOOS) were assessed at brace fitting and final follow-up. Brace compliance, complications and surgical interventions were also collected. Statistical analysis utilised paired t-test. RESULTS. 71 patients (LCOA n=47, LTPF n=21, SONK n=3) were analysed. VAS, OKS and KOOS scores show significant improvements after bracing (p<0.05). Brace compliance was 90.5%. One patient developed a deep-vein thrombosis, 12.7% suffered skin irritation (n=5 LTPF/n=4 LCOA) managed with bio-skin calf sleeves, and brace intolerance occurred in 8.5% (n=6). Brace survivorship was 64.8% (n=46). Twenty-five patients underwent post-bracing surgery; LTPF n=2, LCOA n=22, SONK n=1. The mean time interval between brace fitting and arthroplasty for LKOA patients was 2.1 (range 0.5-4) years. CONCLUSION. Our cohort demonstrates good compliance and significant improvements with cLUB across acute and chronic pathologies. Surgery and associated risks were avoided in certain cases. Further research is required alongside a cost-analysis. However, with increasing disease burden and surgical waiting times cLUB could be a crucial component of management in selected knee pathology cases


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 2 | Pages 172 - 179
1 Feb 2008
Pinczewski LA Salmon LJ Jackson WFM von Bormann RBP Haslam PG Tashiro S

There is little evidence examining the relationship between anatomical landmarks, radiological placement of the tunnels and long-term clinical outcomes following anterior cruciate ligament (ACL) reconstruction. The aim of this study was to investigate the reproducibility of intra-operative landmarks for placement of the tunnels in single-bundle reconstruction of the ACL using four-strand hamstring tendon autografts. Isolated reconstruction of the ACL was performed in 200 patients, who were followed prospectively for seven years with use of the International Knee Documentation Committee forms and radiographs. Taking 0% as the anterior and 100% as the posterior extent, the femoral tunnel was a mean of 86% (. sd. 5) along Blumensaat’s line and the tibial tunnel was 48% (. sd. 5) along the tibial plateau. Taking 0% as the medial and 100% as the lateral extent, the tibial tunnel was 46% (. sd. 3) across the tibial plateau and the mean inclination of the graft in the coronal plane was 19° (. sd. 5.5). The use of intra-operative landmarks resulted in reproducible placement of the tunnels and an excellent clinical outcome seven years after operation. Vertical inclination was associated with increased rotational instability and degenerative radiological changes, while rupture of the graft was associated with posterior placement of the tibial tunnel. If the osseous tunnels are correctly placed, single-bundle reconstruction of the ACL adequately controls both anteroposterior and rotational instability


The Bone & Joint Journal
Vol. 101-B, Issue 1_Supple_A | Pages 53 - 58
1 Jan 2019
Billi F Kavanaugh A Schmalzried H Schmalzried TP

Aims. Loosening of the tibial component after total knee arthroplasty (TKA) is a common indication for revision. Increasing the strength of the initial tibial implant/cement interface is desirable. There is little information about the surgical techniques that lead to the highest strength. We investigated the effects of eight variables on the strength of the initial tibial baseplate/cement interface. Materials and Methods. A total of 48 tibial trays were cemented into acrylic holders using cement from two manufacturers, at three different times (early, normal, and late) using two techniques: cementing the tibial plateau or the plateau and the keel; and involving two conditions of contamination with marrow fat (at the metal/cement and cement/cement interfaces). Push-out tests were performed with load continuously recorded. Results. Compared with normal conditions, early cementing increased the mean strength of the interface when using the two cements, Simplex and Palacos, by 48% and 72%, respectively. Late cementing reduced the strength by 47% and 73%, respectively. Cementing the keel increased the mean strength by 153% and 147%, respectively, for the two cements. Contamination of the metal/cement interface with fat reduced the mean strength by 99% and 94% for the two cements but adding cement to the underside of the tibial tray prior to insertion resulted in the mean strength being lowered by only 65% and 43%, respectively. Conclusion. In order to maximize the strength of the tibial tray/cement interface, cement should be applied to the component soon after mixing, contamination of the interface should be avoided, and the keel and the plateau should be cemented