Introduction. In contrast to knee arthroplasty, there is no national register on high
Introduction. High
High
Background. Medial opening-wedge high
We aimed to analyse complication rates following medial opening-wedge high
The primary aim was to assess survival of the opening wedge high
Despite multiple published reviews, the optimum method of correction and stabilisation of Blount's disease remains controversial. The purpose of this study is to evaluate the clinical and radiological outcomes of acute correction of late-onset tibial vara by percutaneous proximal
The role of mesenchymal stem cells (MSCs) in enhancing healing process has been examined with allogeneic and xenogeneic cells in transplantation models. However, certain factors might limit the use of allogeneic cells in clinical practice, (e.g. disease transmission, ethical issues and patient acceptance). Adipose tissue represents an abundant source for autologous cells. The aim of this study was to evaluate adipose-derived autologous cells for preventing non-union. Adults male Wistar rats (n=5) underwent a previously published surgical procedure known to result in non-union if no treatment is given. This consisted of a mid-shaft
Adequate perpendicular access to the posterolateral talar dome for osteochondral defect repair is difficult to achieve and a number of different surgical approaches have been described. This cadaveric study examined the exposure available from various approaches to help guide pre-operative surgical planning. Four surgical approaches were performed in a step-wise manner on 9 Thiel-embalmed cadavers; anterolateral approach with arthrotomy, anterolateral approach with anterior talo-fibular ligament (ATFL) release, anterolateral approach with antero-lateral
Objectives. Small animal models of fracture repair primarily investigate
indirect fracture healing via external callus formation. We present
the first described rat model of direct fracture healing. Methods. A rat
Fracture repair occurs by two broad mechanisms:
direct healing, and indirect healing with callus formation. The effects
of bisphosphonates on fracture repair have been assessed only in
models of indirect fracture healing. A rodent model of rigid compression plate fixation of a standardised
tibial osteotomy was used. Ten skeletally mature Sprague–Dawley
rats received daily subcutaneous injections of 1 µg/kg ibandronate
(IBAN) and ten control rats received saline (control). Three weeks
later a
We evaluated the effect of low-intensity pulsed ultrasound stimulation (LIPUS) on the remodelling of callus in a rabbit gap-healing model by bone morphometric analyses using three-dimensional quantitative micro-CT. A
Introduction. We evaluated the osteogenic potential of a novel biomimetic bone paste (DBSint®), made of a combination of a human demineralized bone matrix (hDBM) and a nano-structured magnesium-enriched hydroxyapatite (Mg-HA), in a standardized clinical model of high
Background. There is growing evidence in literature that meniscal allograft transplantation performed with the right indications results in significant pain relief and functional improvement of the involved joint. Long-term data on clinical and radiological outcome are however scarce. Methods. We evaluated 89 transplants (53 lateral and 36 medial) in 87 patients. Mean time of follow-up was 15,5 ± 2,85 years (range 9,9–20,4), mean age at surgery was 35,2 years (range 22–50). Clinically, the patients were evaluated using a KOOS, SF-36, HSS, VAS, Tegner and Lysholm score. HSS scores were compared to pre-operative and mid-term follow-up data. Each patient received radiographs (AP, profile and Rosenberg view). Radiological outcome parameters were joint space width narrowing and Fairbank changes and were scored according to IKDC. Failures were defined as patients who were converted to an arthroplasty. Results. HSS-scores improved significantly from 119 ± 27pre-operatively to 160 ± 40 at long-term follow-up. Lysholm-score was 69 ± 22, which was defined as a fair result. Mean VAS-score was 3,4 ± 3, mean Tegner was 4 ± 2. There were no significant differences between following subgroups: left or right knee, medial or lateral allograft, combined procedure with a high
Tibial plateau fractures are serious injuries about the knee that have the potential to affect patients’ long-term function. To our knowledge, this is the first study to use patient-reported outcomes (PROs) with a musculoskeletal focus to assess the long-term outcome, as compared to a short-term outcome baseline, of tibial plateau fractures treated using modern techniques. In total, 102 patients who sustained a displaced tibial plateau fracture and underwent operative repair by one of three orthopaedic traumatologists at a large, academic medical centre and had a minimum of five-year follow-up were identified. Breakdown of patients by Schatzker classification is as follows: two (1.9%) Schatzker I, 54 (50.9%) Schatzker II, two (1.9%) Schatzker III, 13 (12.3%) Schatzker IV, nine (8.5%) Schatzker V, and 26 (24.5%) Schatzker VI. Follow-up data obtained included: Visual Analogue Scale (VAS) or Numeric Rating Scale (NRS) pain scores, Short Musculoskeletal Functional Assessment (SMFA), and knee range of movement (ROM). Data at latest follow-up were then compared to 12-month data using a paired Aims
Methods
Dual plating of distal femoral fractures with medial and lateral implants has been performed to improve construct mechanics and alignment, in cases where isolated lateral plating would be insufficient. This may potentially compromise vascularity, paradoxically impairing healing. This study investigates effects of single versus dual plating on distal femoral vascularity. A total of eight cadaveric lower limb pairs were arbitrarily assigned to either 1) isolated lateral plating, or 2) lateral and medial plating of the distal femur, with four specimens per group. Contralateral limbs served as matched controls. Pre- and post-contrast MRI was performed to quantify signal intensity enhancement in the distal femur. Further evaluation of intraosseous vascularity was done with barium sulphate infusion with CT scan imaging. Specimens were then injected with latex medium and dissection was completed to assess extraosseous vasculature.Aims
Methods
We present 10–15 year follow-up of 33 patients who underwent Elmslie-Trillat osteotomy for severe patellar subluxation or dislocation. In the literature it has been reported that
Using human cadaver specimens, we investigated
the role of supplementary fibular plating in the treatment of distal
tibial fractures using an intramedullary nail. Fibular plating is
thought to improve stability in these situations, but has been reported
to have increased soft-tissue complications and to impair union
of the fracture. We proposed that multidirectional locking screws
provide adequate stability, making additional fibular plating unnecessary.
A distal tibiofibular osteotomy model performed on matched fresh-frozen
lower limb specimens was stabilised with reamed nails using conventional
biplanar distal locking (CDL) or multidirectional distal locking
(MDL) options with and without fibular plating. Rotational stiffness
was assessed under a constant axial force of 150 N and a superimposed
torque of ± 5 Nm. Total movement, and neutral zone and fracture
gap movement were analysed. In the CDL group, fibular plating improved stiffness at the tibial
fracture site, albeit to a small degree (p = 0.013). In the MDL
group additional fibular plating did not increase the stiffness.
The MDL nail without fibular plating was significantly more stable
than the CDL nail with an additional fibular plate (p = 0.008). These findings suggest that additional fibular plating does not
improve stability if a multidirectional distal locking intramedullary
nail is used, and is therefore unnecessary if not needed to aid
reduction. Cite this article:
We reviewed 59 bone graft substitutes marketed
by 17 companies currently available for implantation in the United Kingdom,
with the aim of assessing the peer-reviewed literature to facilitate
informed decision-making regarding their use in clinical practice.
After critical analysis of the literature, only 22 products (37%)
had any clinical data. Norian SRS (Synthes), Vitoss (Orthovita),
Cortoss (Orthovita) and Alpha-BSM (Etex) had Level I evidence. We question
the need for so many different products, especially with limited
published clinical evidence for their efficacy, and conclude that
there is a considerable need for further prospective randomised
trials to facilitate informed decision-making with regard to the
use of current and future bone graft substitutes in clinical practice. Cite this article:
Bicondylar tibial plateau fractures result from
high-energy injuries. Fractures of the tibial plateau can involve
the tibial tubercle, which represents a disruption to the extensor
mechanism and logically must be stabilised. The purpose of this
study was to identify the incidence of an independent tibial tubercle
fracture in bicondylar tibial plateau fractures, and to report management
strategies and potential complications. We retrospectively reviewed
a prospectively collected orthopaedic trauma database for the period
January 2003 to December 2008, and identified 392 bicondylar fractures
of the tibial plateau, in which 85 tibial tubercle fractures (21.6%)
were identified in 84 patients. There were 60 men and 24 women in
our study group, with a mean age of 45.4 years (18 to 71). In 84 fractures
open reduction and internal fixation was undertaken, either with
screws alone (23 patients) or with a plate and screws (61 patients).
The remaining patient was treated non-operatively. In all, 52 fractures
were available for clinical and radiological assessment at a mean
follow-up of 58.5 weeks (24 to 94). All fractures of the tibial
tubercle united, but 24 of 54 fractures (46%) required a secondary
procedure for their tibial plateau fracture. Four patients reported
pain arising from prominent tubercle plates and screws, which in
one patient required removal. Tibial tubercle fractures occurred
in over one-fifth of the bicondylar tibial plateau fractures in
our series. Fixation is necessary and can be reliably performed
with screws alone or with a screw and plate, which restores the
extensor mechanism and facilitates early knee flexion. Cite this article: