Proximal tibial fracture is one of the most common postoperative complications of unilateral knee arthroplasty (UKA). The objective of the present study is to investigate the risk factors of these fractures, occurred after UKA in our facility. We performed 314 UKAs between May 2006 and December 2013. All cases were done using Oxford UKA. Proximal tibial fractures were observed in 5 cases. 4 cases were female and 1 case was male, and the age at the operation ranged from 73 to 90. All cases were osteoarthritis. 4 cases were diagnosed as stress fracture with minimum displacement, and 1 case was fracture with displacement. We investigated the risk factors of the tibial fracture among those 5 cases. Low bone mineral density(BMD), the presence of medial tibial cortex pinhole, excessive vertical cut, and adjacence of keel and posterior tibia cortex were estimated as risk factors.Objectives
Method
Open
Introduction. Diaphyseal tibial fractures account for approximately 1.9% of adult fractures. Several studies demonstrate a high proportion of diaphyseal tibial fractures have ipsilateral occult posterior malleolus fractures, this ranges from 22–92.3%. Materials and Methods. A retrospective review of a prospectively collected database was performed at Liverpool University Hospitals NHS Foundation Trust between 1/1/2013 and 9/11/2020. The inclusion criteria were patients over 16, with a diaphyseal tibial fracture and who underwent a CT. The articular fracture extension was categorised into either posterior malleolar (PM) or other fracture. Results. 764 fractures were analysed, 300 had a CT. There were 127 intra-articular fractures. 83 (65.4%) cases were PM and 44 were other fractures. On univariate analysis for PM fractures, fibular spiral (p=.016) fractures, no fibular fracture(p=.003), lateral direction of the tibial fracture (p=.04), female gender (p=.002), AO 42B1 (p=.033) and an increasing angle of tibial fracture. On multivariate regression analysis a high angle of
Orthopaedic injuries in the knee are often associated with vascular injury. When these vascular injuries are missed devastating there are devastating outcomes like limb ablation. Pulse examination in these patients is not sensitive to exclude vascular injuries. That often lead to clinicians opting for Computed Tomography Angiogram (CTA) to exclude vascular. this usually leads to a burden in Radiology Department. This study aimed to evaluate the prevalence of vascular injury in patient with orthopaedic injury in the knee. The computed tomography (CT) done in patients with distal femur fracture, knee dislocation and proximal
Introduction. Open fractures of the tibia are disabling injuries with a significant risk of deep infection. Treatment involves early antibiotic administration, early and aggressive surgical debridement, and may require complex soft tissue coverage techniques. The extent of disruption to the skin and soft-tissue envelope often varies, with ‘simple’ open fractures (defined by the Orthopaedic Trauma Society (OTS) open fracture severity classification) able to be closed primarily, whilst others may require shortening or soft-tissue reconstruction. This study aimed to determine whether OTS simple tibial open fractures received different rates of adequate debridement and plastic surgical presence at initial debridement, compared with OTS complex injuries, and whether rates of fracture-related infection, nonunion, or reoperation differed between the groups. Materials & Methods. A consecutive series of open
This study aimed to investigate the outcomes of open
Introduction. Diaphyseal tibial fractures account for approximately 1.9% of adult fractures. Studies have demonstrated a high proportion have ipsilateral occult posterior malleolus fractures. We hypothesize that this rotational element will be highlighted using the Mason & Molloy Classification. Materials and Methods. A retrospective review of a prospectively collected database was performed at Liverpool University Hospitals NHS Foundation Trust between 1/1/2013 and 9/11/2020. The inclusion criteria were patients over 16, with a diaphyseal tibial fracture, who underwent a CT. The Mason and Molloy posterior malleolus fracture classification system was used. Results. 764 diaphyseal tibial fractures were analysed, 300 had a CT. 127 were intra-articular fractures. 83 (27.7%) were classifiable using Mason and Molloy classification. There were 8 type 1 (9.6%), 43 type 2 (51.8%), 5 type 2B (6.0%) and 27 type 3 (32.5%). 90.4% (n=75) of the posterior malleolar fractures, were undisplaced. The majority of PM fractures occurred in type 42A1 (65 of 142 tibia fractures) and 42B1 (11 of 16). Conclusions. Most PM fractures occurred after a rotational mechanism. Unlike, the PM fractures of the ankle, the majority of PM fractures associated with
Background:. There are multiple risk factors regarding the outcome of open
Aim. The reconstruction of bone critical size defects of the tibia is one of the most complex therapeutic challenges in the orthopedic field. This study aims to describe and evaluate our three-staged surgical protocol of reconstruction of infected defects of the tibia emphasizing in limb salvage rate, resolution of infection, functional outcome and patient satisfaction. Method. A retrospective review was performed in all cases of complex infected
Introduction. The optimal treatment of high-energy
Traditional procedures for orthopedic total joint replacements have relied upon bone cement to achieve long-term implant fixation. This remains the gold standard in number of procedures including TKR and PKR. In many cases however, implants fixed with cement have proven susceptible to aseptic loosening and 3. rd. body wear concerns. These issues have led to a shift away from cement fixation and towards devices that rely on the natural osteoconductive properties of bone and the ability of porous-coated implants to initiate on-growth and in-growth at the bone interface, leading to more reliable fixation. To facilitate long-term fixation through osseointegration, several mechanical means have been utilized as supplemental mechanism to aid in stabilizing the prostheses. These methods have included integrated keels and bone screws. The intent of these components is to limit implant movement and provide a stable environment for bone ingrowth to occur. Both methods have demonstrated limitations on safety and performance including bone fracture due keel induced stresses, loosening due to inconsistent pressfit of the keel, screw-thread stripping in cancellous bone, head-stripping, screw fracture, screw loosening, and screw pullout. An alternative method of fixation utilizing blade-based anchoring has been developed to overcome these limitations. The bladed-based fixation concept consists of a titanium alloy anchor with a “T-shaped” cross-section and sharped-leading end that can be impacted directly into bone. The profile is configured to have a bladed region on the horizontal crossbar of the “T” for engagement into bone and a solid rail at the other end to mates with a conforming slot on the primary body of the prosthesis. A biased chisel tip is added to the surface of the leading blade edge to draw the bone between the anchor's horizontal surface and surface of the implant, thus generating a compressive force at the bone-to-prothesis interface. The anchoring mechanism has been successfully been integrated into the tibial tray component of a partial knee replacement; an implant component that has a clinical history of revision due to loosening. A detailed investigation into the pulloff strength, wear debris generation, compressive-force properties, and susceptibility to
The standard of wide tumour-like resection for chronic osteomyelitis (COM) has been challenged recently by adequate debridement. This paper reviews the evolution of surgical debridement for long bone COM, and presents the outcome of adequate debridement in a tertiary bone infection unit. We analyzed the retrospective record review from 2014 to 2020 of patients with long bone COM. All were managed by multidisciplinary infection team (MDT) protocol. Adequate debridement was employed for all cases, and no case of wide resection was included.Aims
Methods
Purpose of the study:. Is circular external fixation a safe and effective method of managing closed distal third
Introduction. Today, Uganda has the second highest rate of road accidents in Africa and the world after Ethiopia. According to the World Health Organization's Global Status Report on Road Safety 2013, Uganda is named among countries with alarmingly high road accident rates. If such trend of traffic accidents continues to increase, the health losses from traffic injuries may be ranked as the second to HIV/AIDS by 2020. These road traffic accidents often result in terrible open injuries. Open fractures are complex injuries of bone and soft tissue. They are orthopedic emergencies due to risk of infection secondary to contamination and compromised soft tissues and sometimes vascular supply and associated healing problems. Any wound occurring on the same limb should be suspected as result of open fracture until proven otherwise. The principles of management of open fracture are initial evaluation and exclusion of life threatening injuries, prevention of infection, healing of fracture and restoration of function to injured extremity. Because of the poor hygienic circumstances and the high rate of cross-infection due to the crowded patient-wards, the risk of getting a post-operative infection is relatively high. Osteoset-T® (Wright Medical) is a medical grade calcium sulfate bone graft substitute which is enhanced for use in infected sites by incorporating 4% tobramycin sulfate. The tobramycin is released locally, allowing therapeutic antibiotic levels at the graft site, while maintaining low systemic antibiotic levels. This local treatment of infection allows new bone formation in the defect site, while decreasing potential systemic effects. Purpose/aim. Prevention and treatment of postoperative osteomyelitis by introducing alcoholic hand-sanitizers and the use of wound debridement and implantation of a medicated bone graft substitute. Materials and Methods. We treated some existing osteomyelitis cases and some open fractures with the medicated bone graft substitutes, at Kilembe Mines Hospital, Uganda. A proper debridement with sequestrectomy when needed was performed after which the pellets were implanted and the wound was closed. A preoperative X-ray was taken as well as clinical pictures. Post-operative x-rays were obtained at 6 weeks post-operative and 6 months post-operative when possible. The case presented in this abstract is a 25year old nurse with a bilateral open
Introduction. Segmental
Purpose. Our hypothesis was that closed
Introduction. Segmental
The aim of the study was to assess the results of treating knee osteoarthrosis with total knee arthroplasty (TKA) after previous tibia and/or femur fractures resulting in axial limb deformities. Thirty-six knees (34 patients) were operated on. At the most recent follow-up, 4.8 years after surgery, all but one patient demonstrated an improvement in both clinical and functional KSS. This male patient required revision after 2 years due to tibial component aseptic loosening. Improved range of motion was generally noted, especially extension, however, two patients with both tibia and femur fractures had worse results. TKA is an effective method of treatment for patients with arthrosis after a previous femur or
The purpose of this study was to evaluate and to compare the mechanical stability of external fixation with and without ankle spanning fixation using a foot plate in an in-vitro model of periarticular distal
Orthopaedic infection is a potentially serious complication of elective and emergency trauma and orthopaedic procedures, with a high associated burden of morbidity and cost. Optimization of vitamin D levels has been postulated to be beneficial in the prevention of orthopaedic infection. This study explores the role of vitamin D in orthopaedic infection through a systematic review of available evidence. A comprehensive search was conducted on databases including Medline and Embase, as well as grey literature such as Google Scholar and The World Health Organization Database. Pooled analysis with weighted means was undertaken.Aims
Methods