Despite the successful, durable results, concern remains for using TKA in patients with isolated patello-femoral OA, as it requires an extensive surgical exposure and bone resection, a long recovery time, and a potentially more complex revision than that required for a patient with a failed patello-femoral arthroplasty (PFA). PFA was introduced in the late 1970s. While PFA was successful in providing pain relief, the procedure did not gain widespread use because of initial design limitations that predisposed to PF maltracking, catching, and subluxation. The mechanical complications associated with first-generation PFA offset the potential advantages of maintaining the knee's native soft tissues and spurred efforts to improve implant design, and to refine surgical techniques and patient selection. Over the past two decades, second generation PFAs incorporated changes in implant design and instrumentation and have shown promising results when used in the properly selected patient population. In addition, with improved instrumentation and robotics, adequate implant alignment and rotation can be achieved in the majority of patients, including those with severe patellofemoral dysplasia. Our meta-analysis of TKA and PFA for the treatment of isolated patello-femoral OA showed that the rate of complications of patients undergoing PFA was 30% after a median follow up of 5.3 years, which is significantly higher than the 7% rate of complications in patients who underwent TKA. The most frequent type of complication associated with PFA was mechanical (including loosening and instability), which is consistent with the malalignment and maltracking-related failures previously reported. The incidence of re-operation after PFA (21%) was significantly higher than that seen after TKA (2%). The most frequent indication for re-operation after PFA was mechanical failure (7%), followed by progression of OA (6%), and persistent pain or stiffness (5%). The most common re-operations after PFA were conversion to TKA, revision of PFA components, lateral releases, open or arthroscopic debridement, manipulations under anesthesia, and bony and/or soft tissue extensor mechanism re-alignment procedures. In our study, 11% of patients treated with PFA underwent a revision arthroplasty, with 4% undergoing revision PFA and 7% undergoing conversion to TKA. Our comparison of patients who were treated with second-generation PFA designs versus TKA showed no difference in the rate of complications, re-operation, or revision arthroplasty. Additionally, length of follow-up did not significantly influence any of these outcomes when comparing second-generation PFA and TKA. These observations provide support for the use of current PFA designs. The mechanical complications and subsequent re-operations that affected first-generation PFA designs appear to be of less concern with proper patient selection, meticulous surgical technique, current implant designs and peri-operative care. While it is difficult to predict the survivorship of current PFA designs, it is our expectation that patient selection will continue to be a critical component in determining long-term results. The potential benefit of providing pain relief while preserving the tibiofemoral articulations makes PFA a promising treatment option.
Isolated patellofemoral arthritis is not an uncommon problem, with no clear consensus on treatment. Nonoperative and many forms of operative treatments have failed to demonstrate long-term effectiveness in the setting of advanced arthritis. Total knee arthroplasty (TKA) has produced excellent results, but many surgeons are hesitant to perform TKA in younger patients with isolated patellofemoral arthritis. In properly selected patients, patellofemoral arthroplasty (PFA) is an effective procedure with good long-term results. Contemporary PFA prostheses have eliminated many of the patellar maltracking problems associated with older designs, and short-term results, as described here, are encouraging. Long-term outcome and prospective trials comparing TKA to PFA are needed.
Epidemiologic studies indicate that isolated patellofemoral (PF) arthritis affects nearly 10% of the population over 40 years of age, with a predilection for females. A small percentage of patients with PF arthritis may require surgical intervention. Surgical options include non-arthroplasty procedures (arthroscopic debridement, tibial tubercle unloading procedures, cartilage restoration, and patellectomy), and patellofemoral or total knee arthroplasty (PFA or TKA). Historically, non-arthroplasty surgical treatment has provided inconsistent results, with short-term success rates of 60–70%, especially in patients with advanced arthritis. Although TKA provides reproducible results in patients with isolated PF arthritis, it may be undesirable for those interested in a more conservative, kinematic-preserving approach, particularly in younger patients, who may account for nearly 50% of patients undergoing surgery for PF arthritis. Due to these limitations, patellofemoral arthroplasty (PFA) has become utilised more frequently over the past two decades. The ideal candidate for PFA has isolated, non-inflammatory PF arthritis resulting in “anterior” pain and functional limitations. Pain should be retro- and/or peri-patellar and exacerbated by descending stairs/hills, sitting with the knee flexed, kneeling and standing from a seated position. There should be less pain when walking on level ground. Symptoms should be reproducible during physical examination with squatting and patellar inhibition testing. An abnormal Q-angle or J-sign indicate significant maltracking and/or dysplasia, particularly with a previous history of patellar dislocations. The presence of these findings may necessitate concomitant realignment surgery with PFA. Often, patients with PF arthritis will have significant quadriceps weakness, which should be treated with preoperative physical therapy to prevent prolonged postoperative pain and functional limitations. Tibiofemoral joint pain suggests additional pathology, which may not be amenable to PFA alone.Introduction
Indications for PFA
Total knee arthroplasty (TKA) has produced excellent results, but many surgeons are hesitant to perform TKA in younger patients with isolated patellofemoral arthritis. In properly selected patients, patellofemoral arthroplasty (PFA) is an effective procedure with good long-term results. Contemporary PFA prostheses have eliminated many of the patellar maltracking problems associated with older designs, and short-term results, as described here, are encouraging. Long-term outcome and prospective trials comparing TKA to PFA are needed. Isolated patellofemoral arthritis occurs in as many as 11% of men and 24% of women older than age 55 years with symptomatic osteoarthritis (OA) of the knee; Isolated patellofemoral arthritis found in 9.2% of patients older than age 40 years; 7% to 19% of patients experience residual anterior knee pain when TKA is done for isolated patellofemoral arthritis Weight bearing AP radiographs as supine radiographs can underestimate the extent of tibiofemoral arthritis; Midflexion posteroanterior radiographs to rule out posterior condylar wear; Lateral radiographs to identify the presence or absence of patella alta or baja; Axial radiographs identify the presence of trochlear dysplasia, patellar tilt or subluxation, and extent of patellofemoral arthritis; Magnetic resonance imaging and arthroscopic photographs should be reviewed if availableIncidence
Imaging
Isolated patellofemoral arthritis is not an uncommon problem, with no clear consensus on treatment. Nonoperative and many forms of operative treatments have failed to demonstrate long-term effectiveness in the setting of advanced arthritis. Total knee arthroplasty (TKA) has produced excellent results, but many surgeons are hesitant to perform TKA in younger patients with isolated patellofemoral arthritis. In properly selected patients, patellofemoral arthroplasty (PFA) is an effective procedure with good long-term results. Contemporary PFA prostheses have eliminated many of the patellar maltracking problems associated with older designs, and short-term results, as described here, are encouraging. Long-term outcome and prospective trials comparing TKA to PFA are needed.
The aim of this review is to evaluate the current
available literature evidencing on peri-articular hip endoscopy
(the third compartment). A comprehensive approach has been set on
reports dealing with endoscopic surgery for recalcitrant trochanteric
bursitis, snapping hip (or coxa-saltans; external and internal),
gluteus medius and minimus tears and endoscopy (or arthroscopy)
after total hip arthroplasty. This information can be used to trigger
further research, innovation and education in extra-articular hip
endoscopy.
Aims. The aim of this study was to investigate whether intraoperative 3D fluoroscopic imaging outperforms dorsal tangential views in the detection of dorsal cortex screw penetration after volar plating of an intra-articular distal radial fracture, as identified on postoperative CT imaging. Methods. A total of 165 prospectively enrolled patients who underwent volar plating for an intra-articular distal radial fracture were retrospectively evaluated to study three intraoperative imaging protocols: 1) standard 2D fluoroscopic imaging with anteroposterior (AP) and elevated lateral images (n = 55); 2) 2D fluoroscopic imaging with AP, lateral, and dorsal tangential views images (n = 50); and 3) 3D fluoroscopy (n = 60). Multiplanar reconstructions of postoperative CT scans served as the reference standard. Results. In order to detect dorsal screw penetration, the sensitivity of dorsal tangential views was 39% with a negative predictive value (NPV) of 91% and an accuracy of 91%; compared with a sensitivity of 25% for 3D fluoroscopy with a NPV of 93% and an accuracy of 93%. On the postoperative CT scans, we found penetrating screws in: 1) 40% of patients in the 2D fluoroscopy group; 2) in 32% of those in the 2D fluoroscopy group with AP, lateral, and dorsal tangential views; and 3) in 25% of patients in the 3D fluoroscopy group. In all three groups, the second compartment was prone to penetration, while the postoperative incidence decreased when more advanced imaging was used. There were no penetrating screws in the
Introduction. Patella implant research is often overlooked despite its importance as the
Giant cell tumour of bone (GCTB) treatment changed since the introduction of denosumab from purely surgical towards a multidisciplinary approach, with recent concerns of higher recurrence rates after denosumab. We evaluated oncological, surgical, and functional outcomes for distal radius GCTB, with a critically appraised systematic literature review. We included 76 patients with distal radius GCTB in three sarcoma centres (1990 to 2019). Median follow-up was 8.8 years (2 to 23). Seven patients underwent curettage, 38 curettage with adjuvants, and 31 resection; 20 had denosumab.Aims
Methods
In the last decade, interest in partial knee arthroplasties and bicruciate retaining total knee arthroplasties has increased. In addition, patient-related outcomes and functional results such as range of movement and ambulation may be more promising with less invasive procedures such as bicompartmental arthroplasty (BCA). The purpose of this study is to evaluate clinical and radiological outcomes after a third-generation patellofemoral arthroplasty (PFA) combined with a medial or lateral unicompartmental knee arthroplasty (UKA) at mid- to long-term follow-up. A total of 57 procedures were performed. In 45 cases, a PFA was associated with a medial UKA and, in 12, with a lateral UKA. Patients were followed with validated patient-reported outcome measures (Oxford Knee Score (OKS), EuroQol five-dimension questionnaire (EQ-5D), EuroQoL Visual Analogue Scale (EQ-VAS)), the Knee Society Score (KSS), the Forgotten Joint Score (FJS), and radiological analysis.Aims
Methods
We describe a new technique for fixing the proximal pole scaphoid fractures both in acute and chronic setting and present our preliminary results. We prospectively studied fixation of 25 proximal pole scaphoid fractures (1 acute displaced and 24 non unions) with this technique between 1999 and 2007. Mean age of patients was 25 years and mean time to the operation was 6 months. The technique involves making a transverse dorsal incision over the radius along the radio-carpal junction. The retinaculum is split in line with its fibres. Access to the radio-carpal joint is achieved through the
A retrospective analysis of the treatment of distal radius fractures with an angularly stable locking plate (Matrix Plate, Stryker, UK) via a dorsal approach performed at Southend University Hospital in the United Kingdom. 91 fractures were treated over a three year period between 2004 and 2007. Dorsally angulated and displaced (including intraarticular) fractures were included. All patients commenced early mobilization without splintage on the first post-operative day. The study group consisted of 42 men and 49 women with a mean age of 63 years. The average time to follow up was 19 months (range 6–29). The average tourniquet time was 44 minutes (20–81). Assessment consisted of range of motion and grip strength measurement, Mayo wrist score, quick DASH questionnaire and Gartland and Werley scoring. Complications consisted of 1 EPL rupture and 3 patients suffered extensor irritation. To date only 5 plates (5.4%) have been removed. We demonstrate that dorsal plating using a low profile, angularly stable plate produces comparable results to volar plating. The combination of a low profile, angular stable plate, together with a modification of the standard dorsal approach, a sub-periosteal approach via the fourth and deep to the
The aims of this study were to evaluate the clinical and radiological
outcomes of the Universal-2 total wrist arthroplasty (TWA) in patients
with rheumatoid arthritis. This was a retrospective review of all 95 Universal-2 TWAs which
were performed in our institution between 2003 to 2012 in patients
with rheumatoid arthritis. A total of six patients were lost to
follow-up and two died of unrelated causes. A total of ten patients
had bilateral procedures. Accordingly, 75 patients (85 TWAs) were
included in the study. There were 59 women and 16 men with a mean
age of 59 years (26 to 86). The mean follow-up was 53 months (24
to 120). Clinical assessment involved recording pain on a visual
analogue score, range of movement, grip strength, the Quick Disabilities
of the Arm, Shoulder and Hand (DASH) and Wrightington wrist scores.
Any adverse effects were documented with particular emphasis on
residual pain, limitation of movement, infection, dislocation and
the need for revision surgery. Radiographic assessment was performed pre-operatively and at
three, six and 12 months post-operatively, and annually thereafter.
Arthroplasties were assessed for distal row intercarpal fusion and
loosening. Radiolucent zones around the components were documented
according to a system developed at our institution.Aims
Patients and Methods
The use of volar locking compression plates for the treatment of fractures of the distal radius is becoming increasingly popular because of the stable biomechanical construct, less soft-tissue disturbance and early mobilisation of the wrist. A few studies have reported complications such as rupture of flexor tendons. We describe three cases of rupture of extensor tendons after the use of volar locking compression plates. We recommend extreme care when drilling and placing the distal radial screws to prevent damaging the extensor tendons.
The aims of this study were to assess the efficacy
of a newly designed radiological technique (the radial groove view)
for the detection of protrusion of screws in the groove for the
extensor pollicis longus tendon (EPL) during plating of distal radial
fractures. We also aimed to determine the optimum position of the
forearm to obtain this view. We initially analysed the anatomy of
the EPL groove by performing three-dimensional CT on 51 normal forearms.
The mean horizontal angle of the groove was 17.8° (14° to 23°).
We found that the ideal position of the fluoroscopic beam to obtain
this view was 20° in the horizontal plane and 5° in the sagittal
plane. We then intra-operatively assessed the use of the radial groove
view for detecting protrusion of screws in the EPL groove in 93
fractures that were treated by volar plating. A total of 13 protruding
screws were detected. They were changed to shorter screws and these
patients underwent CT scans of the wrist immediately post-operatively.
There remained one screw that was protruding. These findings suggest
that the use of the radial groove view intra-operatively is a good
method of assessing the possible protrusion of screws into the groove
of EPL when plating a fracture of the distal radius. Cite this article:
Strains applied to bone can stimulate its development and adaptation. High strains and rates of strain are thought to be osteogenic, but the specific dose response relationship is not known.