We report
Aims. The aim of this study was to evaluate medium-term outcomes and complications of the S-ROM NOILES Rotating Hinge Knee System (DePuy, USA) in revision total knee arthroplasty (rTKA) at a tertiary unit. Methods. A retrospective consecutive study of all patients who underwent a rTKA using this implant from January 2005 to December 2018. Outcome measures included reoperations, revision for any cause, complications, and survivorship. Patients and implant survivorship data were identified through both local hospital electronic databases and linked data from the National Joint Registry/NHS Personal Demographic Service. Kaplan-Meier survival analysis was used at ten years. Results. A total of 89 consecutive patients (89 knees) were included with 47 females (52.8%) and a median age of 74 years (interquartile range 66 to 79). The main indications were aseptic loosening with instability (39.4%; n = 35) and infection (37.1%; n = 33) with the majority of patients managed through two-stage approach. The mean follow-up was 7.4 years (2 to 16). The overall rate of reoperation, for any cause, was 10.1% (n = 9) with a rate of implant revision of 6.7% (n = 6). Only two cases required surgery for patellofemoral complications. Kaplan-Meier implant-survivorship analysis was 93.3% at ten years, using revision for any cause as an endpoint. Conclusion. This implant achieved high
Aims. This study compares the PFC total knee arthroplasty (TKA) system in a prospective randomized control trial (RCT) of the mobile-bearing rotating-platform (RP) TKA against the fixed-bearing (FB) TKA. This is the largest RCT with the longest follow-up where cruciate-retaining PFC total knee arthroplasties are compared in a non-bilateral TKA study. Patients and Methods. A total of 167 patients (190 knees with 23 bilateral cases), were recruited prospectively and randomly assigned, with 91 knees receiving the RP and 99 knees receiving FB. The mean age was 65.5 years (48 to 82), the mean body mass index (BMI) was 29.7 kg/m. 2. (20 to 52) and 73 patients were female. The Knee Society Score (KSS), Knee Society Functional Score (KSFS), Oxford Knee Score (OKS), Western Ontario and McMaster Universities Arthritis Index (WOMAC), and 12-Item Short-Form Health Survey Physical and Mental Component Scores (SF-12 PCS, SF-12 MCS) were gathered and recorded preoperatively, at five-years’ follow-up, and at ten years’ follow-up. Additionally, Knee Injury and Osteoarthritis Outcome Scores (KOOS) were collected at five- and
We report the
The aim of this study was to determine whether obesity had a detrimental effect on the long-term performance and survival of medial unicompartmental knee arthroplasties (UKAs). This study reviewed prospectively collected functional outcome scores and revision rates of all medial UKA patients with recorded BMI performed in Christchurch, New Zealand, from January 2011 to September 2021. Patient-reported outcome measures (PROMs) were the primary outcome of this study, with all-cause revision rate analyzed as a secondary outcome. PROMs were taken preoperatively, at six months, one year, five years, and ten years postoperatively. There were 873 patients who had functional scores recorded at five years and 164 patients had scores recorded at ten years. Further sub-group analysis was performed based on the patient’s BMI. Revision data were available through the New Zealand Joint Registry for 2,323 UKAs performed during this time period.Aims
Methods
Polyethylene particulate wear debris continues to be implicated in the aetiology of aseptic loosening following knee arthroplasty. The Oxford unicompartmental knee arthroplasty employs a spherical femoral component and a fully congruous meniscal bearing to increase contact area and theoretically reduce the potential for polyethylene wear. This study measures the in vivo
As the surgical indications for total knee replacement (TKR) expand to include younger, heavier and more active patients, knowledge of the effect of these demographic variables on the outcome and survival of the implant is increasingly important. Between November 1986 and September 1990, 402 patients underwent 562 primary cemented cruciate-retaining TKRs carried out by a single surgical team. The overall results showed a survival of 96.8% at 14 years with 1.44% lost to follow-up. Evaluating the demographics of these patients showed that certain groups fared significantly less well. The best results were seen in non-obese women with osteoarthritis who were over 60 years of age in whom there was
OtisMed Shape Match ® patient specific implant cutting jigs were designed to place TKA in kinematic alignment (KA) rather than traditional mechanical alignment (MA). This product was withdrawn from the market in 2013. It has been hypothesised that KA might lead to early implant failure. Initial evidence has not supported this. We present 10 year outcome data for the largest single centre cohort to date. Between 2010 and 2013, 127 Shape Match® TKAs were implanted in 119 individuals. Retrospective review of long leg post-operative radiographs assessed femoral mechanical anatomical angle (FMA), tibial mechanical angle (TMA), hip-knee-ankle angle (HKA), posterior tibial slope (PTS) and femoral component flexion. Oxford Knee Scores (OKS), revision and further surgery rates were reviewed.Abstract
Introduction
Methodology
We report a
Whilst short and mid-term activity levels after a Total Knee Replacement (TKR) have been reported in the literature; there is an over simplification of the reporting and longer-term activity levels are unknown. The aim of this study was to map the long-term trajectories of patients’ physical activity levels postoperatively to identify meaningful subgroups and explore associations with preoperative variables. This was a secondary analysis of a single centre longitudinal cohortstudy using group-based trajectory modelling (GBTM) of the University of California, Los Angeles (UCLA) physical activity score over ten years. Multinomial logistic regression models (both adjusted and unadjusted) were used to test associations between preoperative variables and trajectory group membership.Abstract
Aims
Methods
We set out to demonstrate the 10-year survivorship of the PFC sigma TKA in a young patient group. Demographic and clinical outcome data were collected prospectively at 6 months, 18 months, 3 years, 5 years and 8-10 years post surgery. The data were analysed using Kaplan Meier survival statistics with end point being regarded as death or revision for any reason. 203 patients were found to be ≤55 years at the time of surgery. Four patients required revision and four patients died. Another four patients moved away from the region and were excluded from the study. A total of 224 knees in 199 patients (101 male and 98 females.) 168 patients had a diagnosis of Osteoarthritis and 28 with inflammatory arthritis. Average age 50.6 years range 28-55 years (median 51).
The Oxford Unicompartmental Knee Replacement's (OUKR's) fully-congruent design minimises polyethylene wear. Consequently, wear is a rare failure mechanism. Phase-3 OUKR linear wear at 5 years was higher than previous OUKR phases, but very low compared to fixed-bearing UKRs. This study aimed to measure OUKR bearing wear at 10 years and investigate factors that may affect wear. Bearing thickness for 39 OUKRs from a randomised study was calculated using radiostereometric analysis at regular intervals up to 10 years. Data for 39 and 29 OUKRs was available at 5 and 10 years, respectively. As creep occurs early, wear rate was calculated using linear regression between 6 months and 10 years. Relationships between wear and patient factors, fixation method, Oxford Knee Score (OKS), bearing position, and component position were analysed.Abstract
Introduction
Methodology
Cementless fixation of Oxford Unicompartmental Knee Replacements (UKRs) is an alternative to cemented fixation, however, it is unknown whether cementless fixation is as good long-term. This study aimed to compare primary and long-term fixation of cemented and cementless Oxford UKRs using radiostereometric analysis (RSA). Twenty-nine patients were randomised to receive cemented or cementless Oxford UKRs and followed for ten years. Differences in primary fixation and long-term fixation of the tibial components (inferred from 0/3/6-month and 6-month/1-year/2-year/5-year/10-year migration, respectively) were analysed using RSA and radiolucencies were assessed on radiographs. Migration rates were determined by linear regression and clinical outcomes measured using the Oxford Knee Score (OKS).Abstract
Introduction
Methodology
Since 2012 we have routinely used the cementless Oxford medial unicompartmental knee arthroplasty (mUKA), with microplasty instrumentation, in patients with anteromedial osteoarthritis (AMOA) meeting modern indications. We report the 10-year survival of 1000 mUKA with minimum 4-year follow-up. National Joint Registry (NJR) surgeon reports were interrogated for each senior author to identify the first 1,000 mUKAs performed for osteoarthritis. A minimum of 4 years follow-up was required. There was no loss to follow-up. The NJR status of each knee was established. For each mUKA revision the indication and mechanism of failure was determined using local patient records. The 10-year implant survival was calculated using life-table analysis.Abstract
Background
Methods
Medial fix bearing unicompartmental knee replacement (UKR) designs are consider safe and effective implants with many registries data and big cohort series showing excellent survivorship and clinical outcome comparable to that reported for the most expensive and surgically challenging medial UKR mobile bearing designs. However, whether all polyethylene tibial components (all-poly) provided comparable results to metal-backed modular components during medial fix bearing UKR remains unclear. There have been previous suggestions that all-poly tibia UKR implants might show unacceptable higher rates of early failure due to tibial component early loosening especially in high body max index (BMI) patients. This study aims to find out the short and long-term survival rate of all-poly tibia UKR and its relationship with implant thickness and patient demographics including sex, age, ASA and BMI. we present the results of a series of 388 medial fixed bearing all-polly tibia UKR done in our institution by a single surgeon between 2007–2019.Abstract
Introduction
Material and Methods
The success of total knee replacement (TKR) surgery can be attributed to improvements in TKR design, instrumentation, and surgical technique. Over a decade ago oxidized zirconium (OxZr) femoral components were introduced as an alternative bearing surface to cobalt-chromium (CoCr), based on strong in-vitro evidence, to improve the longevity of TKR implants. Early reports have demonstrated the clinical success of this material however no long-term comparative studies have demonstrated the superiority of OxZr implants compared to a more traditional CoCr implant. This study aims to compare long-term survivorship and outcomes in OxZr and CoCr femoral components in a single total knee design. We reviewed our institutional database to identify all patients whom underwent a TKA with a posterior stabilized OxZr femoral component with a minimum of 10 years of follow-up. These were then matched to patients whom underwent a TKA with the identical design posterior stabilized CoCr femoral component during the same time period by gender, age and BMI. All patients had their patella resurfaced. All patients were prospectively evaluated preoperatively and postoperatively at 6 weeks, 3 months, 12 months, 2 years and every 1 to 2 years thereafter. Prospectively collected clinical outcome measures included, Western Ontario and McMaster Universities osteoarthritis index (WOMAC), Short-Form 12 (SF-12) and Knee Society clinical rating scores (KSCRS). Charts and radiographs were reviewed to determine the revision rates and survivorship (both all cause and aseptic) at 10 years allowing comparison between the two cohorts. Paired analysis was performed to determine if differences existed in patient reported outcomes.Purpose
Methods
Unicompartmental knee replacement (UKR) offers advantages over total knee replacement but has higher revision rates particularly for aseptic loosening. Cementless UKR was introduced in an attempt to address this. We used National Joint Registry (NJR) data to compare the 10-year results of cemented and cementless mobile bearing UKR whilst matching for important patient, implant and surgical factors. We also explored the influence of caseload on outcome. We performed a retrospective observational study using NJR data on 30,814 cemented and 9,708 cementless mobile bearing UKR implanted between 2004 and 2016. Logistic regression was utilised to calculate propensity scores allowing for matching of cemented and cementless groups for various patient, implant and surgical confounders, including surgeon's caseload, using a one to one ratio. 14,814 UKRs (7407 cemented and 7407 cementless) were propensity score matched. Outcomes studied were revision, defined as removal, addition or exchange of a component, and reasons for revision. Implant survival was compared using Cox regression models and groups were stratified according to surgeon caseload.Introduction
Methods
Autologous chondrocyte implantation (ACI) and
mosaicplasty are methods of treating symptomatic articular cartilage
defects in the knee. This study represents the first long-term randomised
comparison of the two techniques in 100 patients at a minimum follow-up
of ten years. The mean age of the patients at the time of surgery was
31.3 years (16 to 49); the mean duration of symptoms pre-operatively
was 7.2 years (9 months to 20 years). The lesions were large with
the mean size for the ACI group being 440.9 mm2 (100
to 1050) and the mosaicplasty group being 399.6 mm2 (100
to 2000). Patients had a mean of 1.5 previous operations (0 to 4)
to the articular cartilage defect. Patients were assessed using
the modified Cincinnati knee score and the Stanmore-Bentley Functional Rating
system. The number of patients whose repair had failed at ten years
was ten of 58 (17%) in the ACI group and 23 of 42 (55%) in the mosaicplasty
group (p <
0.001). The functional outcome of those patients with a surviving graft
was significantly better in patients who underwent ACI compared
with mosaicplasty (p = 0.02).
Between 2003 and 2007, 99 knees in 77 patients
underwent opening wedge high tibial osteotomy. We evaluated the effect
of initial stable fixation combined with an artificial bone substitute
on the mid- to long-term outcome after medial opening-wedge high
tibial osteotomy (HTO) for medial compartmental osteoarthritis or
spontaneous osteonecrosis of the knee in 78 knees in 64 patients
available for review at a minimum of five years (mean age 68 years;
49 to 82). The mean follow-up was 6.5 years (5 to 10). The mean
Knee Society knee score and function score improved from 49.6 ( Opening-wedge HTO using a stable plate fixation system combined
with a bone substitute is a reliable procedure that provides excellent
results. Although this treatment might seem challenging for older
patients, our results strongly suggest that the results are equally
good. Cite this article:
Aims. Total knee arthroplasty (TKA) with a highly congruent condylar-stabilized (CS) articulation may be advantageous due to increased stability versus cruciate-retaining (CR) designs, while mitigating the limitations of a posterior-stabilized construct. The aim was to assess