Advertisement for orthosearch.org.uk
Results 1 - 20 of 2853
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 45 - 45
1 Jun 2023
Robinson M Mackey R Duffy C Ballard J
Full Access

Introduction. Osteogenesis imperfect (OI) is a geno- and phenotypically heterogeneous group of congenital collagen disorders characterized by fragility and microfractures resulting in long bone deformities. OI can lead to progressive femoral coxa vara from bone and muscular imbalance and continuous microfracture about the proximal femur. If left untreated, patients develop Trendelenburg gait, leg length discrepancy, further stress fracture and acute fracture at the apex of the deformity, impingement and hip joint degeneration. In the OI patient, femoral coxa vara cannot be treated in isolation and consideration must be given to protecting the whole bone with the primary goal of verticalization and improved biomechanical stability to allow early loading, safe standing, re-orientation of the physis and avoidance of untreated sequelae. Implant constructs should therefore be designed to accommodate and protect the whole bone. The normal paediatric femoral neck shaft angle (FNSA) ranges from 135 to 145 degrees. In OI the progressive pathomechanical changes result in FNSA of significantly less than 120 degrees and decreased Hilgenreiner epiphyseal angles (HEA). Proximal femoral valgus osteotomy is considered the standard surgical treatment for coxa vara and multiple surgical techniques have been described, each with their associated complications. In this paper we present the novel technique of controlling femoral version and coronal alignment using a tubular plate and long bone protection with the use of teleoscoping rods. Methodology. After the decision to operate had been made, a CT scan of the femur was performed. A 1:1 scale 3D printed model (AXIAL3D, Belfast, UK) was made from the CT scan to allow for accurate implant templating and osteotomy planning. In all cases a subtrochanteric osteotomy was performed and fixed using a pre-bent 3.5 mm 1/3 tubular plate. The plate was bent to allow one end to be inserted into the proximal femur to act as a blade. A channel into the femoral neck was opened using a flat osteotome. The plate was then tapped into the femoral neck to the predetermined position. The final position needed to allow one of the plate holes to accommodate the growing rod. This had to be determined pre operatively using the 3D printed model and the implants. The femoral canal was reamed, and the growing rod was placed in the femur, passing through the hole in the plate to create a construct that could effectively protect both the femoral neck and the full length of the shaft. The distal part of the plate was then fixed to the shaft using eccentric screws around the nail to complete the construct. Results. Three children ages 5,8 and 13 underwent the procedure. Five coxa vara femurs have undergone this technique with follow-up out to 62 months (41–85 months) from surgery. Improvements in the femoral neck shaft angle (FNSA) were av. 18. o. (10–38. o. ) with pre-op coxa vara FNSA av. 99. o. (range 87–114. o. ) and final FNSA 117. o. (105–125. o. ). Hilgenreiner's epiphyseal angle was improved by av. 29. o. (2–58. o. ). However only one hip was restored to <25. o. In the initial technique employed for 3 hips, the plates were left short in the neck to avoid damaging the physis. This resulted in 2 of 3 hips fracturing through the femoral neck above the plate at approximately 1 year. There were revisions of the 3 hips to longer plates to prevent intra-capsular stress riser. All osteotomies united and both intracapsular fractures healed. No further fractures have occurred within the protected femurs and no other repeat operations have been required. Conclusions. Surgical correction of the OI coxa vara hip is complex. Bone mineral density, multiplanar deformity, a desire to maintain physeal growth and protection of the whole bone all play a role in the surgeon's decision making process. Following modifications, this technique demonstrates a novel method in planning and control of multiplanar proximal femoral deformity, resulting in restoration of the FNSA to a more appropriate anatomical alignment, preventing long bone fracture and improved femoral verticalization in the medium term follow-up


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 38 - 38
1 Jun 2023
Hrycaiczuk A Biddlestone J Rooney B Mahendra A Fairbairn N Jamal B
Full Access

Introduction. A significant burden of disease exists with respect to critical sized bone defects; outcomes are unpredictable and often poor. There is no absolute agreement on what constitutes a “critically-sized” bone defect however it is widely considered as one that would not heal spontaneously despite surgical stabilisation, thus requiring re-operation. The aetiology of such defects is varied. High-energy trauma with soft tissue loss and periosteal stripping, bone infection and tumour resection all require extensive debridement and the critical-sized defects generated require careful consideration and strategic management. Current management practice of these defects lacks consensus. Existing literature tells us that tibial defects 25mm or great have a poor natural history; however, there is no universally agreed management strategy and there remains a significant evidence gap. Drawing its origins from musculoskeletal oncology, the Capanna technique describes a hybrid mode of reconstruction. Mass allograft is combined with a vascularised fibula autograft, allowing the patient to benefit from the favourable characteristics of two popular reconstruction techniques. Allograft confers initial mechanical stability with autograft contributing osteogenic, inductive and conductive capacity to encourage union. Secondarily its inherent vascularity affords the construct the ability to withstand deleterious effects of stressors such as infection that may threaten union. The strengths of this hybrid construct we believe can be used within the context of critical-sized bone defects within tibial trauma to the same success as seen within tumour reconstruction. Methodology. Utilising the Capanna technique in trauma requires modification to the original procedure. In tumour surgery pre-operative cross-sectional imaging is a pre-requisite. This allows surgeons to assess margins, plan resections and order allograft to match the defect. In trauma this is not possible. We therefore propose a two-stage approach to address critical-sized tibial defects in open fractures. After initial debridement, external fixation and soft tissue management via a combined orthoplastics approach, CT imaging is performed to assess the defect geometry, with a polymethylmethacrylate (PMMA) spacer placed at index procedure to maintain soft tissue tension, alignment and deliver local antibiotics. Once comfortable that no further debridement is required and the risk of infection is appropriate then 3D printing technology can be used to mill custom jigs. Appropriate tibial allograft is ordered based on CT measurements. A pedicled fibula graft is raised through a lateral approach. The peroneal vessels are mobilised to the tibioperoneal trunk and passed medially into the bone void. The cadaveric bone is prepared using the custom jig on the back table and posterolateral troughs made to allow insertion of the fibula, permitting some hypertrophic expansion. A separate medial incision allows attachment of the custom jig to host tibia allowing for reciprocal cuts to match the allograft. The fibula is implanted into the allograft, ensuring nil tension on the pedicle and, after docking the graft, the hybrid construct is secured with multi-planar locking plates to provide rotational stability. The medial window allows plate placement safely away from the vascular pedicle. Results. We present a 50-year-old healthy male with a Gustilo & Anderson 3B proximal tibial fracture, open posteromedially with associated shear fragment, treated using the Capanna technique. Presenting following a fall climbing additional injuries included a closed ipsilateral calcaneal and medial malleolar fracture, both treated operatively. Our patient underwent reconstruction of his tibia with the above staged technique. Two debridements were carried out due to a 48-hour delay in presentation due to remote geographical location of recovery. Debridements were carried out in accordance with BOAST guidelines; a spanning knee external fixator applied and a small area of skin loss on the proximal medial calf reconstructed with a split thickness skin graft. A revision cement spacer was inserted into the metaphyseal defect measuring 84mm. At definitive surgery the external fixator was removed and graft fixation was extended to include the intra-articular fragments. No intra-operative complications were encountered during surgeries. The patient returned to theatre on day 13 with a medial sided haematoma. 20ml of haemoserous fluid was evacuated, a DAIR procedure performed and antibiotic-loaded bioceramics applied locally. Samples grew Staphylococcus aureus and antibiotic treatment was rationalised to Co-Trimoxazole 960mg BD and Rifampicin 450mg BD. The patient has completed a six-week course of Rifampicin and continues on suppressive Co-Trimoxazole monotherapy until planned metalwork removal. There is no evidence of ongoing active infection and radiological evidence of early union. The patient is independently walking four miles to the gym daily and we believe, thus far, despite accepted complications, we have demonstrated a relative early success. Conclusions. A variety of techniques exist for the management of critical-sized bone defects within the tibia. All of these come with a variety of drawbacks and limitations. Whilst acceptance of a limb length discrepancy is one option, intercalary defects of greater than 5 to 7cm typically require reconstruction. In patients in whom fine wire fixators and distraction osteogenesis are deemed inappropriate, or are unwilling to tolerate the frequent re-operations and potential donor site morbidity of the Masqualet technique, the Capanna technique offers a novel solution. Through using tibial allograft to address the size mismatch between vascularised fibula and tibia, the possible complication of fatigue fracture of an isolated fibula autograft is potentially avoidable in patients who have high functional demands. The Capanna technique has demonstrated satisfactory results within tumour reconstruction. Papers report that by combining the structural strength of allograft with the osteoconductive and osteoinductive properties of a vascularised autograft that limb salvage rates of greater than 80% and union rates of greater than 90% are achievable. If these results can indeed be replicated in the management of critical-sized bone defects in tibial trauma we potentially have a treatment strategy that can excel over the more widely practiced current techniques


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 19 - 19
1 Nov 2022
Agrawal P Gilbert R
Full Access

Abstract. Ramp lesions are meniscocapsular or meniscosynovial tears associated with chronic ACL injury and are postulated to occur because of disruption of meniscotibial ligament. Various techniques have been described in literature for their diagnosis and repair. Each of the described techniques have had some concerns. The authors, hereby, describe a novel technique for RAMP repair. Our Technique. Patient is positioned supine with the knee at 90 degrees with a side support. Standard arthroscopic portals are established. Ramp lesions are visualised through a trans-notch approach and probed simultaneously using an 18-guage needle posteromedialy. Once the diagnosis has been confirmed a posteromedial (PM) portal is established. The edges of the tear are freshened from the PM portal using a shaver or rasp. Knee Scorpion device (Arthrex) is then introduced through the PM which is loaded with No. 0 Fibrewire (Arthrex) in its lower jaw. The Scorpion device is deployed on the capsular side first, avoiding injury to the posterior structures and the suture loop is retrieved. Scorpion is loaded again with the other strand and is passed through the meniscal edge. A sliding knot is used. Ramp lesion is re-probed after tying a sliding knot for requirement of another suture. This technique provides us with an improved visualisation and diagnosis, better quality of debridement and complete closure of the ramp lesion using a simple suture device. In our experience this is a safe, successful and easily reproducible technique


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 33 - 33
1 Jun 2023
Franco AC Hemmady R Green RN Giles SN Fernandes JA
Full Access

The Masquelet technique, also known as the ‘induced membrane technique’ has been utilised in adult reconstruction with varied success. However, there is limited literature on its use in children and this study aims to share our experience. Materials & Methods. Between 2014 and 2022, 7 children underwent bone defect/infection reconstruction using Masquelet technique, four for complications of Congenital Pseudoarthrosis of Tibia (CPT) treatment, two with chronic osteomyelitis and one for Osteogenesis imperfecta with infected nonunion. The length of the defect relative to the length of the bone (index of reconstruction expressed as a percentage), time to union and complications were evaluated with standard radiographs and from electronic medical records. Results. The mean age was 11 years and the procedure was done in five tibiae, one femur and a metatarsal. The mean time interval was 7.1 weeks between the first and second stage surgery. The mean index of reconstruction was 25.8% and the mean follow up period was 17 months. Though six patients achieved union with a mean time to union of 6.5 months (range 4.5 to 10), two patients with multiple previous surgeries for CPT decided to have ablation despite union. The interosseous Masquelet technique of cross synostosis between the tibia and fibula is being highlighted. Conclusions. The Masquelet technique is a reliable method in complex aetiologies and complications that require methodical planning to achieve good results especially in rescue situations of the tibia


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 45 - 45
7 Nov 2023
Mwelase S Maré P Marais L Thompson D
Full Access

Children with osteogenesis imperfecta (OI) frequently present with coxa vara (CV). Skeletal fragility, severe deformity and limited fixation options make this a challenging condition to correct surgically. Our study aimed to determine the efficacy of the Fassier technique to correct CV and determine the complication rate. Retrospective, descriptive case series from a tertiary hospital. We retrospectively reviewed records of a cohort of eight children (four females, 12 hips) with OI (6/8 Sillence type III, 2/8 type IV) who had surgical treatment with Fassier technique for CV between 2014 and 2020. Inclusion Criteria: All patients with CV secondary to OI treated surgically with Fassier technique. Exclusion Criteria: Patients older than 18 years; Patients with CV treated non-operatively or by surgical technique different to Fassier technique. Data relating to the following parameters was collected and analyzed: demographic data, pre- and postoperative neck shaft angle (NSA), complications and NSA at final follow-up. The mean age at operation was 5.8 years (range 2–10). The mean NSA was corrected from 96.8° preoperatively to 137º postoperatively. At a mean follow-up of 38.6 months, the mean NSA was maintained at 133°, and 83% (10/12) of hips had an NSA that remained greater than 120°. There was a 42% (5/12) complication rate: three Fassier–Duval rods failed to expand after distal epiphyseal fixation was lost during growth; one Rush rod migrated through the lateral proximal femur cortex with recurrent coxa vara; and one Rush rod migrated proximally and required rod revision. The Fassier technique effectively corrected CV in children with moderate and progressively deforming OI. The deformity correction was maintained in the short term. The complication rate was high, but mainly related to the failed expansion of the Fassier–Duval rods


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 40 - 40
1 Jun 2023
Al-Omar H Patel K Lahoti O
Full Access

Introduction. Angular deformities of the distal femur can be corrected by opening, closing and neutral wedge techniques. Opening wedge (OW) and closing wedge (CW) are popular and well described in the literature. CW and OW techniques lead to leg length difference whereas the advantage of neutral wedge (NW) technique has several unique advantages. NW technique maintains limb length, wedge taken from the closing side is utilised on the opening side and since the angular correction is only half of the measured wedge on either side, translation of distal fragment is minimum. Leg lengths are not altered with this technique hence a useful technique in large deformities. We found no reports of clinical outcomes using NW technique. We present a technique of performing external fixator assisted NW correction of large valgus and varus deformities of distal femur and dual plating and discuss the results. Materials & Methods. We have treated 20 (22 limbs – 2 patients requiring staged bilateral corrections) patients for distal femoral varus and valgus deformities with CWDFO between 2019 and 2022. Out of these 4 patients (5 limbs) requiring large corrections of distal femoral angular deformities were treated with Neutral Wedge (NW) technique. 3 patients (four limbs) had distal femoral valgus deformity and one distal femoral varus deformity. Indication for NW technique is an angular deformity (varus or valgus of distal femur) requiring > 12 mm opening/closing wedge correction. We approached the closing side first and marked out the half of the calculated wedge with K – wires in a uniplanar fashion. Then an external fixator with two Schanz screws is applied on the opposite side, inserting the distal screw parallel to the articular surface and the proximal screw 6–7 cm proximal to the first pin and at right angles to the femoral shaft mechanical axis. Then the measured wedge is removed and carefully saved. External fixator is now used to close the wedge and over correct, creating an appropriate opening wedge on the opposite side. A Tomofix (Depuoy Synthes) plate is applied on the closing side with two screws proximal to osteotomy and two distally (to be completed later). Next the osteotomy on the opposite side is exposed, the graft is inserted. mLDFA is measured under image intensifier to confirm satisfactory correction. Closing wedge side fixation is then completed followed by fixation of opposite side with a Tomofix or a locking plate. Results. 3 patients (4 limbs) had genu valgum due to constitutional causes and one was a case of distal femoral varus from a fracture. Preoperative mLDFA ranged from 70–75° and in one case of varus deformity it was 103°. We achieved satisfactory correction of mLDFA in (85–90°) in 4 limbs and one measured 91°. Femoral length was not altered. JLCA was not affected post correction. Patients were allowed to weight bear for transfers for the first six weeks and full weight bearing was allowed at six weeks with crutches until healing of osteotomy. All osteotomies healed at 16–18 weeks (average 16.8 weeks). Patients regained full range of movement. We routinely recommend removal of metal work to facilitate future knee replacement if one is needed. Follow up ranged from 4 months to 2 yrs. Irritation from metal work was noted in 2 patients and resolved after removing the plates at 9 months post-surgery. Conclusions. NWDFO is a good option for large corrections. We describe a technique that facilitates accurate correction of deformity in these complex cases. Osteotomy heals predictably with uniplanar osteotomy and dual plate fixation. Metal work might cause irritation like other osteotomy and plating techniques in this location


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 80 - 80
1 Apr 2019
Ikuta Muratsu Kamimura Tachibana Oshima Koga Matsumoto Maruo Miya Kuroda
Full Access

Introduction. Modified gap technique has been reported to be beneficial for the intraoperative soft tissue balancing in posterior-stabilized (PS) -TKA. We have found intraoperative ligament balance changed depending on joint distraction force, which might be controlled according to surgeons' fells. We have developed a new surgical concept named as “medial preserving gap technique (MPGT)” to preserve medial knee stability and provide quantitative surgical technique according to soft tissue balance measurement using a tensor device. The purpose of this study was to compare 3-years postoperative knee stability after PS-TKA in varus type osteoarthritic (OA) knees between MPGT and measured resection technique (MRT). Material & Method. The subjects were 94 patients underwent primary unilateral PS-TKA for varus type OA knees. The surgical technique was MPGT in 47 patients and MRT in 47 patients. An originally developed off-set type tensor device was used to evaluate intraoperative soft tissue balance. In MPGT, medial release was limited until the spacer block corresponding to the bone thickness from proximal lateral tibial plateau could be easily inserted. Femoral component size and external rotation angle were adjusted depending on the differences of center gaps and varus angles between extension and flexion before posterior femoral condylar resection. The knee stabilities at extension and flexion were assessed by stress radiographies at 1 and 3 years after TKA; varus-valgus stress test at extension and stress epicondylar view at flexion. We measured medial and lateral joint openings (MJO, LJO) at both knee extension and flexion. MJOs and LJOs at 2 time periods were compared in each group using paired t-test. Each joint opening distance was compared between 2 groups using unpaired t-test. The significance level was set as P < 0.05. Results. The mean extension MJOs at 1 and 3 years after TKA were 2.4, 2.6 mm in MPGT and 3.2, 3.1 mm in MRT respectively. The mean extension LJOs were 3.5, 3.5 mm in MPGT and 4.6, 4.5 mm in MRT. The mean flexion MJOs were 0.95, 0.77 mm in MPGT and 1.5, 1.2 mm in MRT, and the mean flexion LJOs were 2.2, 2.1 mm in MPGT and 3.0, 2.7 mm in MRT. MJOs were significantly smaller than LJOs in each group at 2 time periods. MJOs at extension and flexion, and LJOs at extension were significantly smaller in MPGT than MRT at 2 time periods. Discussion. Medial knee stabilities had been reported to be essential for postoperative clinical results. We reported medial compartment gap was more stable during mid-to-deep knee flexion in MPGT than MRT. MPGT provided the more stable intraoperative soft tissue balance than MRT in PS-TKA. MPGT was useful to preserve the higher medial knee stability than the lateral as well as MRT, and beneficial to enhance postoperative knee stabilities as long as 3-years after PS-TKA in varus OA knees. MPGT would be an objective and safer gap technique to enhance clinical outcomes


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 72 - 72
10 Feb 2023
Hollman, F Mohammad J Singh N Gupta A Cutbush K
Full Access

Acromioclavicular joint (ACJ) dislocations is a common disorder amongst our population for which numerous techniques have been described. It is thought that by using this novel technique combining a CC and AC repair with a reconstruction will result in high maintenance of anatomical reduction and functional results. 12 consecutive patients ACJ dislocations were included. An open superior clavicular approach is used. Firstly, the CC ligaments are repaired after which a CC reconstruction is performed using a tendon allograft. Secondly, the AC ligaments are repaired using an internal brace construct combined with a tendon allograft reconstruction (Figure 1). The acute:chronic ratio was 6:6. Only IIIB, IV and V AC-joint dislocations were included. The Constant-Murley Score improved from 27.6 (8.0 – 56.5) up to 61.5 (42.0 – 92.0) at 12 months of follow up. Besides one frozen shoulder from which the patient recovered spontaneously no complications were observed with this technique. The CCD was reduced from 18.7 mm (13.0 – 24.0) to 10.0 mm (6.0 – 16.0) and 10.5 mm (8.0 – 14.0) respectively 12 weeks and 12 months postoperatively. There is some evidence, suggesting to address as well as the vertical (coracoclavicular (CC) ligaments) as the horizontal (acromioclavicular (AC) ligaments) direction of instability. This study supports addressing both entities however comparative studies discriminating chronic as acute cases should be conducted to further clarify this ongoing debate on treating ACJ instability. This study describes a novel technique to treat acute and chronic Rockwood stage IIIB – IV ACJ dislocations with promising short-term clinical and radiological results. This suggests that the combined repair and reconstruction of the AC and CC ligaments is a safe procedure with low complication risk in experienced hands. Addressing the vertical as well as horizontal stability in ACJ dislocation is considered key to accomplish optimal long-term results


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 25 - 25
1 Jun 2023
Pincher B Kirk C Ollivere B
Full Access

Introduction. Bone transport and distraction osteogenesis have been shown to be an effective treatment for significant bone loss in the tibia. However, traditional methods of transport are often associated with high patient morbidity due to the pain and scarring caused by the external frame components transporting the bone segment. Prolonged time in frame is also common as large sections of regenerate need significant time to consolidate before the external fixator can be removed. Cable transport has had a resurgence with the description of the balanced cable transport system. However, this introduced increasingly complex surgery along with the risk of cable weave fracture. This method also requires frame removal and intramedullary nailing, with a modified nail, to be performed in a single sitting, which raised concern regarding potential deep infection. An alternative to this method is our modified cable transport system with early intramedullary nail fixation. Internal cables reduce pain and scarring of the skin during transport and allow for well controlled transport segment alignment. The cable system is facilitated through an endosteal plate that reduces complications and removes the need for a single-stage frame removal and nailing procedure. Instead, the patients can undergo a pin-site holiday before nailing is performed using a standard tibial nail. Early intramedullary nailing once transport is complete reduces overall time in frame and allows full weight bearing as the regenerate consolidates. We present our case series of patients treated with this modified cable transport technique. Methodolgy. Patients were identified through our limb reconstruction database and clinic notes, operative records and radiographs were reviewed. Since 2019, 8 patients (5 male : 3 female) have undergone bone transport via our modified balanced cable transport technique. Average age at time of transport was 39.6 years (range 21–58 years) with all surgeries performed by the senior author. Patients were followed up until radiological union. We recorded the length of bone transport achieved as well as any problems, obstacles or complications encountered during treatment. We evaluated outcomes of full weight bearing and return to function as well as radiological union. Results. 4/8 bone defects were due to severely comminuted open fractures requiring extensive debridement. All other cases had previously undergone fixation of tibial fractures which had failed due to infection, soft tissue defects or mal-reduction. The mean tibial defect treated with bone transport was 41mm (range 37–78mm). From the start of cable transport to removal of external fixator our patients spent an average of 201 days in frame. 7/8 patients underwent a 2-week pin-site holiday and subsequent insertion of intramedullary nail 2 weeks later. One patient had sufficient bony union to not require further internal fixation after frame removal. 10 problems were identified during treatment. These included 4 superficial infections treated with antibiotics alone and 5 issues with hardware, which could be resolved in the outpatient clinic. 1 patient had their rate of transport slowed due to poor skin quality over the site of the regenerate. 4 obstacles resulted in a return to theatre for additional procedures. 1 patient had a re-do corticotomy and 3 had revision of their internal cable transport constructs due to decoupling or screw pull out. 1 patient had residual ankle joint equinus following treatment which required an Achilles tendon lengthening procedure. Another patient underwent treatment for DVT. There were no deep infections identified and no significant limb length discrepancies or deformities. Conclusions. Overall, we have found that our modified balanced cable transport technique has allowed for successful bone transport for significant defects of the tibia. We have learned from the obstacles encountered during this case series to avoid unnecessary return trips to theatre for our future transport patients. The internal cable system allowed all patients to complete their planned transport without excessive pin tract scarring or pain. Early conversion to intramedullary nail allowed for a shorter time in frame with continued full weight bearing as the regenerate consolidated. No metalwork failure or deformity has occurred in relation to docking site union. All patients have made a good return to pre-operative function during their follow-up period with no evidence of late complications such as deep infection


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 115 - 115
1 Aug 2013
Pink M Valousek T Miklas M
Full Access

Introduction. The aim of our study was to compare the radiographic alignment unicompartmental knee arthroplasty (UKA) with using conventional non-navigation technique and computer-assisted navigation technique. Our study was focused on bearing alignment on clinical outcome of knee. Materials and Methods. In our department we have performed between January 2005 and December 2012 106 UKA. All patients were examined clinically and radiologically before and after operation. There were implanted two types of UKA, 67 of UKA were performed by The PRESERVATION™ (DePuy) with navigation and 39 UKA Oxford® Partial Knee (Biomet.) were performed by conventional technique. In our study we have evaluated 104 of medial UKA divided to groups, 65 implantation of The PRESERVATION™ and 39 implantation of Oxford® Partial Knee UKA. We have evaluated 101 patients, 61 women, 40 men, average age 66,5 (50–82) years. Firstly we performed measurement of parameters determine alignment UKA. These values were written down and the deviation of norm was established. Results were divided in two groups, one with values of normal range and the second beyond normal range. Values of all UKA were matched with clinical outcome postoperatively. This assessment was performed by The Knee Society Clinical Rating System (Knee score). Results. The mean follow-up was 3,3 (max. 7,1) years. The group with navigation technique improved Knee score from mean 58 (41–79) preoperatively to 93 (62–100) postoperatively. Conventional UKA Knee score improved from 56 (39–77) preoperatively to 91 (61–100) postoperatively. Clinical outcome is comparable in both groups. Radiological assessment of alignment unicompartmental knee replacement according to our measurement results in favour of computer-assisted navigation. Conclusion. Computer-assisted navigation enables more exact alignment of the femoral and tibial component than conventional technique. In spite of the fact that difference clinical outcome is comparable


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 41 - 41
10 May 2024
Sandiford NA Atkinson B Trompeter A Kendoff D
Full Access

Introduction. Management of Vancouver type B1 and C periprosthetic fractures in elderly patients requires fixation and an aim for early mobilisation but many techniques restrict weightbearing due to re-fracture risk. We present the clinical and radiographic outcomes of our technique of total femoral plating (TFP) to allow early weightbearing whilst reducing risk of re-fracture. Methods. A single-centre retrospective cohort study was performed including twenty-two patients treated with TFP for fracture around either hip or knee replacements between May 2014 and December 2017. Follow-up data was compared at 6, 12 and 24 months. Primary outcomes were functional scores (Oxford Hip or Knee score (OHS/OKS)), Quality of Life (EQ-5D) and satisfaction at final follow-up (Visual Analogue Score (VAS)). Secondary outcomes were radiographic fracture union and complications. Results. Mean OHS and OKS was 50.25, EQ-5D score was >4 for all modalities, VAS was 64.4/100. Radiographs demonstrated bony union in 58% at 3 months and 76% at 6 months. We identified no case of re-fracture however non-union occurred in 4 patients. No other operative complications were identified. Conclusion. These results suggest that TFP may be a safe, viable option for management of periprosthetic fractures around stable implants allowing the benefit of early weightbearing, satisfactory outcomes and low re-fracture risk


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 83 - 83
10 Feb 2023
Lee H Lewis D Balogh Z
Full Access

Distal femur fractures (DFF) are common, especially in the elderly and high energy trauma patients. Lateral locked osteosynthesis constructs have been widely used, however non-union and implant failures are not uncommon. Recent literature advocates for the liberal use of supplemental medial plating to augment lateral locked constructs. However, there is a lack of proprietary medial plate options, with some authors supporting the use of repurposing expensive anatomic pre-contoured plates. The aim of this study was to investigate the feasibility of a readily available cost-effective medial implant option. A retrospective analysis from January 2014 to June 2022 was performed on DFF (primary or revision) managed with supplemental medial plating with a Large Fragment Locking Compression Plate (LCP) T-Plate (~$240 AUD) via a medial sub-vastus approach. The T-plate was contoured and placed superior to the medial condyle. A combination of 4.5mm cortical, 5mm locking and/or 6.5mm cancellous screws were used, with oblique screw trajectories towards the distal lateral cortex of the lateral condyle. All extra-articular fractures and revision fixation cases were allowed to weight bear immediately. The primary outcome was union rate. This technique was utilised on sixteen patients; 3 acute, 13 revisions; mean age 52 years (range 16-85), 81% male, 5 open fractures. The union rate was 100%, with a median time to union of 29 weeks (IQR 18-46). The mean follow-up was 15 months. There were two complications: a deep infection requiring two debridements and a prominent screw requiring removal. The mean range of motion was 1–108. o. . Supplemental medial plating of DFF with a Large Fragment LCP T-Plate is a feasible, safe, and economical option for both acute fixation and revisions. Further validation on a larger scale is warranted, along with considerations to developing a specific implant in line with these principles


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 20 - 20
1 May 2021
Sundarapandian R Nesbitt P Khunda A
Full Access

Introduction. The most challenging aspect in rotational deformity correction is translating the pre-operative plan to an accurate intra-operative correction. Landmarks away from the osteotomy site are typically employed at pre-operative planning and this can render inadequate correction. Our proposed technique of pre-operative planning using CT scan and leg length radiographs can translate to accurate intra-operative correction. Materials and Methods. A circle was superimposed at osteotomy site with its centre serving as the centre of correction of rotation. Medio-lateral distance at osteotomy site measured and used as diameter of the circle. Circumference of the circle was calculated by multiplying diameter with Pi and used in the below formula to obtain accurate de-rotation distance;. Derotation distance = (Circumference/360) × correction value for desired ante-version. The exact site of osteotomy was measured in theatre under C-arm and exposed. Derotation distance was marked on the surface of bone as point A and point B with a flexible ruler. Osteotomy performed with saw and derotation was done till point A and point B were co-linear. Derotation distance obtained using this technique is specific for the site of chosen osteotomy and implies a specific degree of correction for every millimeter derotated. Distal femur was the chosen site of osteotomy if there was associated patellar instability and proximal femur if there was no patellar instability. Results. We have used the above technique to successfully correct rotational malalignment of femur and tibia in three patients thus far. The foot progression angle improved in all patients following surgery. One patient had post-operative CT scan of the hips which showed accurate reduction of ante-version. Conclusions. Our new technique of rotational deformity correction is simple and reproducible using commonly available tools as CT scan and leg length radiographs. This technique effectively translates the pre-operative plan to accurate intra-operative correction of rotational deformity


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 59 - 59
10 Feb 2023
Hancock D Morley D Wyatt M Roberts P Zhang J van Dalen J
Full Access

When removing femoral cement in revision hip surgery, creating an anterior femoral cortical window is an attractive alternative to extended trochanteric osteotomy. We describe our experience and evolution of this technique, the clinical and radiological results, and functional outcomes. Between 2006 and 2021 we used this technique in 22 consecutive cases at Whanganui Hospital, New Zealand. The average age at surgery was 74 years (Range 44 to 89 years). 16 cases were for aseptic loosening: six cases for infection. The technique has evolved to be more precise and since 2019 the combination of CT imaging and 3-D printing technology has allowed patient-specific (PSI) jigs to be created (6 cases). This technique now facilitates cement removal by potentiating exposure through an optimally sized anterior femoral window. Bone incorporation of the cortical window and functional outcomes were assessed in 22 cases, using computer tomography and Oxford scores respectively at six months post revision surgery. Of the septic cases, five went onto successful stage two procedures, the other to a Girdlestone procedure. On average, 80% bony incorporation of the cortical window occurred (range 40 −100%). The average Oxford hip score was 37 (range 22 – 48). Functional outcome (Oxford Hip) scores were available in 11 cases (9 pre-PSI jig and 2 using PSI jig). There were two cases with femoral component subsidence (1 using the PSI jig). This case series has shown the effectiveness of removing a distal femoral cement mantle using an anterior femoral cortical window, now optimized by using a patient specific jig with subsequent reliable bony integration, and functional outcomes comparable with the mean score for revision hip procedures reported in the New Zealand Joint Registry


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 14 - 14
24 Nov 2023
Loïc F Sylvain W Kennedy M Theophile N Olivier NF Marie-Ange NY Jean B
Full Access

Aim. infected segmental bone defect (ISBD) is frequent in developing countries. The aim of this study was to assess the efficacy of the Masquelet technique in the treatment of ISBD in a low-resource setting. Patients and Method. We performed a prospective cohort study during the period from 2018 to 2022. Patients with infected bone defect of long bones were included. Management protocol consisted of two stages in all patients. The first stage consisted in debridement, tissues biopsy for microbiological culture, stabilization with external fixator and defect filling with gentamicin cement spacer. The second stage consisted of reconstruction using a cancellous bone autograft alone, or a mixture of autograft with allograft (demineralized bone matrix + tricalcium phosphate) and 1 gram of vancomycin powder. All patients were followed-up for at least one year. The results were assessed based on both objective (clinical and radiographic evaluation) and subjective (limb function and patient satisfaction) criteria. Main outcomes were bone union, reoperation and failure rates, union time, and limb function. Results. We included 31 patients in this study (80.6% men), with a median age of 35 [9 – 80] years. The tibia was affected in 12 cases and the femur in 15 cases. The median size of bone defect was 4 [1.5 – 12] cm. The most prevalent microorganisms were Klebsiella pneumoniae and Staphylococcus aureus. The mean interval between both stages was 14 (8 – 36) weeks and the median follow-up period after the second stage was 20 [12-62] months. External fixation was used in both stages in 25(80%) cases. Bone union was achieved in 26 (83.8%) patients of whom 24 without recurrence of infection, over a median time of 9 [6 – 16] months. All patients with a mixed graft (allograft and autograft) impregnated with local antibiotics achieved bone union. Two patients needed reoperation for relapse of infection between both stages, and subsequently achieved bone union without recurrence of infection. There were three cases of failure related to persistent infection or insufficient fixation stability in the second stage. Conclusions. Masquelet technique is a reliable procedure that can be safely performed in limited resources settings with satisfactory results. The mixture of autograft and allograft when available, all mixed with vancomycin seems to give promising results


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 36 - 36
1 Apr 2022
Olesen UK
Full Access

Introduction. We demonstrate the preliminary results with a novel technique to solve large bone defects using two lengthening nails, working together and aligned in a custom made device. An illustrative case that successfully produced 17 cm bone in 3.5 months, is presented. Materials and Methods. A 28 year old healthy male presented with a slowly growing mass in the left femur. No general symptoms were reported, no weight loss, no previous illness. Histopathology, CT and MRI scans revealed a malignant diaphyseal bone tumor. A three-stage trifocal bone transport was projected and conducted based on a 3D model test. Results. Trifocal bone transport using two lengthening nails in a custom made device, reduced the 17 cm bone defect in 3.5 months. Follow up was 9 months. Conclusions. The presented technique successfully solved the clinical problem and is a showcase for further developments of internal devices for complex and large bone losses and lengthenings


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_1 | Pages 12 - 12
1 Jan 2022
Belcher P Iyengar KP Loh WYC Uwadiae E
Full Access

Introduction. W. ide . A. wake . L. ocal . A. naesthetic . N. o . T. ourniquet (WALANT) is a well- established day case procedure for carpal tunnel release with several advantages and enhanced post-operative recovery. Use of Local anaesthesia with Adrenaline using a 27G needle allows a bloodless field and distraction techniques achieve patient comfort during the procedure. Objectives. This retrospective, observational cohort study assesses patient satisfaction and undertakes functional evaluation using the validated Boston Carpal Tunnel Questionnaire (BCTQ) following WALANT technique for carpal tunnel release (CTR). The BCTQ has a symptom severity scale based on 11 items and a functional status scale of 8 elements. Further we compare surgical outcomes between techniques of WALANT and traditional CTR. Patient and Methods. We included 30 consecutive patients, 15 in each arm who either underwent traditional CTR with the use of Tourniquet or with the WALANTtechnique. Data was collected from Electronic Patient Records and hand therapy assessments. A satisfaction questionnaire and Visual Analogue Score (VAS) was utilized to evaluate subjective outcomes. Functional outcomes was assessed by BCTQ scoring system and clinical review. Microsoft Excel was used for analysis. Results. 100% of patients in the WALANT group stated they were satisfied with the operation. Relief from night pain and sleep disturbance were the most improved symptoms. BCTQ and clinical assessment evaluation between both groups revealed comparable results with no significant difference. Conclusion. With advantages of no tourniquet related pain, increased patient satisfaction and functional outcomes on the BCTQ scores, WALANT technique has the potential to be the standard technique for CTR


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 25 - 25
1 Nov 2022
Shah N Bagaria V Deshmukh S Tiwari A Shah M
Full Access

Abstract. Aim. To study and compare the rise of Inflammatory markers post TKR operated by Medial parapatellar approach with tourniquet (MP) and by Subvastus approach used without tourniquet. (SV). Materials and Methods. 100 patients were operated for a TKR by two experienced Arthroplasty surgeons utilising either the MP approach or the SV approach. (50 knees each). The groups were well matched as regards age, degree of deformity, obesity, pre-op knee scores and co-morbidities. The patients were managed peri-operatively in an identical manner .5 inflammatory markers viz: IL-6, AST, LDH, CRP and ESR were measured pre-operatively and at 12, 24,48 and 72 hours postoperatively. Additionally, the patients' VAS score at these intervals and Morbidity Index was determined. Results. All the 5 inflammatory markers increased post surgery in both groups. However, the rise of 4 out of the 5 inflammatory markers i(IL-6, AST, CRP, ESR) in the MP group was statistically significantly higher than in the SV group. The LDH values were similar in the two groups. The VAS scores were better in the SV group and the Morbidity Index showed a higher degree of morbidity in the MP group. Discussion. Surgical technique and approach can influence the rise of Inflammatory markers post TKR. Conclusion. The Subvastus tourniquetless approach reliably produces a lesser degree of rise in inflammatory markers post TKR than the medial parapatellar approach used with tourniquet. The subvastus approach should be utilised more to improve the immediate post-operative results following a TKR


Abstract. Background. Extracorporeal radiation therapy (ECRT) has been reported as an oncologically safe and effective reconstruction technique for limb salvage in diaphyseal sarcomas with promising functional results. Factors affecting the ECRT graft-host bone incorporation have not been fully investigated. Methods. In our series of 51 patients of primary bone tumors treated with ECRT, we improvised this technique by using a modified V-shaped osteotomy, additional plates and intra-medullary fibula across the diaphyseal osteotomy in an attempt to increase the stability of fixation, augment graft strength and enhance union at the osteotomy sites. We analyzed our patients for various factors that affected union time and union rate at the osteotomy sites. Results. On univariate analysis, age <20 years, metaphyseal osteotomy site, V-shaped diaphyseal osteotomy, extramedullary plate fixation and use of additional plate at diaphyseal ostetomy had a significantly faster time to union while gender, tumor type, resection length, chemotherapy and use of intra-medullary fibula did not influence union time. In multivariate analysis, metaphyseal ostoeotomy, V-shaped diaphyseal osteotomy and use of additional plate at diaphyseal ostetomy were the independent factors with favourable time to union. Although the rate of union was higher with V-shaped diaphyseal osteotomy and use of additional plate and intra-medullary fibula at diaphyseal ostetomy, this difference could not be established statistically. None of the analyzed factors apparently affected the union rate in univariate analysis. Conclusion. Judicious choice of osteosynthesis and augmentation of ECRT graft can enhance incorporation with reduced complications and good functional outcome


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_20 | Pages 8 - 8
1 Apr 2013
Sharma S Butt M
Full Access

Percutaneous Achilles tenotomy is an integral part of the Ponseti technique. Though considered as a simple procedure, many authors have reported serious neurovascular complications that include iatrogenic injury to the lesser saphenous vein, the posterior tibial neurovascular bundle, the sural artery and pseudoaneurysm formation. The authors describe the results of their new tenotomy technique, the ‘Posterior to Anterior Controlled’ (PAC) technique in an attempt to eliminate such complications. This is a prospective study. Infants < 1 year of age with idiopathic clubfoot were taken up for the Ponseti technique of correction. Tenotomy was performed by the ‘PAC’ technique under local anaesthesia if passive dorsiflexion was found to be < 15 degrees. Outcome measures included completeness of the tenotomy (by ultrasonography), improvement in the equinus angle and occurrence of neurovascular complications. 40 clubfeet in 22 patients underwent ‘PAC’ tenotomy. The mean age was 3.5 months. The tenotomy was found to be complete in all cases. The equinus angle improved by an average of 78.5 degrees (range 70–95 degrees), which was statistically significant (p < 0.05, students t test). Mild soakage of the cast with blood was noted in 21 (52.5%) cases. No neurovascular complication was noted. The average follow-up was 12.2 months (range 9–18 months). The ‘PAC’ tenotomy virtually eliminates the possibility of neurovascular damage, maintains the percutaneous nature of the procedure, is easy to learn and can be performed even by relatively inexperienced surgeons safely and effectively as an office procedure under local anaesthesia