Advertisement for orthosearch.org.uk
Results 1 - 20 of 58
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 440 - 440
1 Sep 2012
Thompson S Reilly P Emery R Bull A
Full Access

Background. Tears of the rotator cuff are a common pathology and poorly understood. Achieving a good functional outcome for patients may be difficult, and the degree of fat infiltration into the muscle is known to be a major determining factor to surgical repair and post operative function. It is the hypothesis of this study that the degree of retraction of the common central tendon as seen on MRI corresponds to the amount of fat infiltration classified according to the Goutallier grading System. Methods. MRI scans of the supraspinatus were reviewed and two groups identified: no tear (NT) and full thickness tear (FTT). The following measures were taken: central tendon retraction (CTR) and the Goutallier Grade according to MRI. The difference between Goutallier grade between NT and FTT were measured using the Mann-Whitney test. The relationship between Goutallier grade and increasing amount of CTR was described using Spearman's rank correlation and differences assessed using Mann-Whitney tests. Results. 143 scans had NT and 148 scans had FTT after exclusion and inclusion criteria were satisfied. All FTT involved the central tendon, with varying retraction. 143 in the NT group were Goutallier Grade 0–1. FTT revealed 2 Grade 0, 21 Grade 1, 35 Grade 2, 14 Grade 3, 76 Grade 4. The difference in Goutallier grade between the NT and FTT was highly significant (p<0.001). The increase in Goutallier grade associated with increasing retraction of the central tendon was also highly significant p<0.001. Conclusion. CTR can be directly linked to Goutallier grading and as such may help to determine surgical intervention between groups. Level of Evidence. Level 1 Diagnostic Study


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 556 - 556
1 Sep 2012
Heikenfeld R Listringhaus R Godolias G
Full Access

Aim. The purpose of this study was to evaluate the results after arthroscopic reconstruction of isolated SSP lesions. Does double row repair in smaller lesions lead to better results and a lower retear rate?. Method. 80 patients with an isolated full thickness SSP tear were divided into 2 groups. Group 1 (27 men, 13 Frauen, average age 57 y.) was repaired using a single row technique with 2 anchors (Mitek Fastin) with arthroscopic Mason-Allen stiches. Group 2 was repaired using a double row technique using 1 medial anchor (Mitek Fastin) and 2 lateral anchors (Versalok). PreOP an ultrasound and MRI was obtained as well as standard x-rays (a.p., outlet-view, transaxial). Included to this study were only patients matching the following criteria: intraoperative cartilage lesions ≤ Outerbridge Grade2, fatty degeneration ≤ Goutallier Grade 2, ap extent of the tear < 2,5 cm. Prospective follow up after 6, 12 and 24 months using UCLA and Constant Score as well as MRI at last follow up. Results. 37 patients in group 1 and 36 patients in group 2 were completely evaluated. Both groups showed improvement in Constant Score from 49,3 to 89,4 in group 1 (single row) compared to 47,6 and 90,7 in group 2 (Double Row). MRI at last follow up showed 4 retears in the single row group and 3 retears in the double row group. 1 shoulder in the double row group needed revision due to a loose anchor. Discussion. We could not find any significant difference between clinical results and retear rate using a single or double row suture anchor configuration in isolated full thickness SSP tears


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 125 - 125
1 Sep 2012
Gerber C Meyer D Nuss K Farshad M
Full Access

Introduction. Following tear of its tendon, the muscle undergoes retraction, atrophy and fatty infiltration. These changes are inevitable and considered irreversible and limit the potential of successful repair of musculotendinous units. It was the purpose of this study to test the hypothesis that administration of anabolic steroids can prevent these muscular changes following experimental supraspinatus tendon release in the rabbit. Methods. The supraspinatus tendon was experimentally released in 20 New Zealand rabbits. Musculotendinous retraction was monitored over a period of 6 weeks. The seven animals in group I had no additional intervention, six animals in group II had local and seven animals in group III had systemic administration of nandrolone deconate during six weeks of retraction. At the time of sacrifice, in-vivo muscle performance as well as radiologic and histologic muscle changes were investigated. Results. Supraspinatus retraction was significantly higher in group I (1.8 ± 0.2cm) than in group II (1.5 ± 0.3cm, p = 0.044) or III (1.2 ± 0.3cm, p = 0.001). The reduction in radiological cross sectional area, as a measure for atrophy, was significant in groups I (p = 0.013) and II (p = 0.030) and insignificant in group III (p = 0.149). Histologically, there was no fatty infiltration in the treated groups II (p = 1.000) and III (p = 0.812), but in the untreated group I (p = 0.0312). The work of the respective muscle during one standardized contraction with supramaximal stimulation decreased markedly in groups I (p = 0.056) and II (p = 0.0528), and also but less in group III (p = 0.23). Conclusion. This is the first documentation of prevention of important muscle alterations after chronic retraction of the musculotendinous unit caused by rotator cuff tear. Nandrolone deconate administration in the post tendon release phase prevented fatty infiltration of the supraspinatus muscle and reduced functional muscle impairment caused by myo-tendinous retraction


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_18 | Pages 13 - 13
1 Dec 2023
Elgendy M Makki D White C ElShafey A
Full Access

Introduction. We aim to assess whether radiographic characteristics of the greater tuberosity fragment can predict rotator cuff tears inpatients with anterior shoulder dislocations combined with an isolated fracture of the greater tuberosity. Methods. A retrospective single-centre case series of 61 consecutive patients that presented with anterior shoulder dislocations combined with an isolated fracture of the greater tuberosity between January 2018 and July 2022. Inclusion criteria: patients with atraumatic anterior shoulder dislocation associated with an isolated fracture of the greater tuberosity with a minimum follow-up of 3-months. Exclusion criteria: patients with other fractures of the proximal humerus or glenoid. Rotator cuff tears were diagnosed using magnetic resonance or ultrasound imaging. Greater tuberosity fragment size and displacement was calculated on plain radiographs using validated methods. Results. The case series was composed of 22 men and 39 women with a mean age of 65 years (29 - 91 years). The mean follow-up was 15months and median follow up 8.5 months (3 – 60 months). A rotator cuff tear was diagnosed in 14 patients (16%) and involved the supraspinatus (13), infraspinatus (4) and subscapularis (2). Full-thickness tears occurred in 6 patients and partial-thickness tears in 8patients. The mean time from initial injury to rotator cuff tear diagnosis was 5 months (2 – 22 months). The mean greater tuberosity fragment length was 23.4 mm in rotator cuff tear patients versus 32.6 mm in those without a tear (p = 0.006, CI: -15 - -2). The mean greater tuberosity. fragment width was 11.1 mm in rotator cuff tear patients versus 17.8 mm in those without a tear (p = 0.0004, CI: -10 - -2). There was no significant difference in the super inferior and anteroposterior fragment displacement between the two groups. Conclusion. In patients with shoulder dislocations combined with an isolated fracture of the greater tuberosity, rotator cuff tears are associated with a smaller sized greater tuberosity fragment


Reconfiguration of elective orthopaedic surgery presents challenges and opportunities to develop outpatient pathways to reduce surgical waiting times. Dupuytren's disease (DD) is a benign progressive fibroproliferative disorder of the fascia in the hand, which can be disabling. Percutaneous-needle-fasciotomy (PNF) can be performed successfully in the outpatient clinic. The Aberdeen hand-service has over 10 years' experience running dedicated PNF clinics. NHS Grampian covers a vast area of Scotland receiving over 11749 referrals to the orthopaedic unit yearly. 250 patients undergone PNF in the outpatient department annually. 100 patients who underwent PNF in outpatients (Jan2019–Jan2020). 79M, 21F. Average age 66 years range (29–87). 95 patients were right hand dominant. DD risk factors: 6 patients were diabetic, 2 epileptic, 87 patients drank alcohol. 76 patients had a family history of DD. Disease severity, single digit 20 patients, one hand multiple digits in 15 patients, bilateral hands in 65 patients of which 5 suffered form ectopic manifestation suggestive of Dupuytren's diasthesis. Using Tubiana Total flexion deformity score pre and post fasciotomy. Type 1 total flexion deformity (TFD) between 0–45 degrees pre PNF n=60 post N= 85, Type 2 TFD 45–90 degrees pre PNF n=18 post N=9, Type 3 TFD 90–135 pre PNF n=15 post N= 5, Type 4 TFD >135 pre PNF n=1 post PNF N=1. Using Chi-square statistical test, a significant difference was found at the p<0.05 between the pre and post PNF TFD. Complication: 8 recurrence, 1 skin tear. No patients sustained digital nerve injury. Outpatients PNF clinics are a valuable resource


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 417 - 417
1 Sep 2012
Chaudhury S Xia Z Hulley P Carr A
Full Access

INTRODUCTION. There is increasing evidence for a multi-stage model of rotator cuff (RC) tendon tears, wherein healing is affected by tear size. The underlying pathophysiology however is not fully understood. Changes in the production and remodeling of the RC extracellular matrix (ECM) are likely to be important determinants of RC tendinopathy as they affect healing and the ability to bear loads. This study aimed to gain greater insight into size related tear pathogenesis by analyzing gene expression profiles from normal, small and massive RC tears. METHODS. The genetic profiles of 28 human RC tendons were analyzed using microarrays representing the entire genome. 11 massive and 5 small torn RC tendon specimens were obtained from tear edges intraoperatively, and compared to 12 age matched normal controls. Semiquantitative real-time polymerase chain reaction (RT-PCR) and immunohistochemistry were performed for validation. RESULTS. Numerous insightful gene changes were detected. Key changes included upregulation of aggrecan in massive tendon tears compared to normal controls, but not in small tears (p < 0.05 and > 2-fold change). Matrix metallopeptidases (MMP)-3,-10,-12,-13,-15,-21,-25 and a disintegrin and metallopeptidase (ADAMs)-12,-15,-22 were significantly upregulated in tears. Aggrecan was upregulated in massive tendon tears but not in small tears. Amyloid was downregulated in the small and massive tear groups when compared to normals. BMP-5 was upregulated in small tears only when compared to normals. As part of the chemotaxis pathway, IL-3,-10,-13,-15,-18 were upregulated in tears, whereas downregulation of IL-1,-8,-11,-27, was seen. RT-PCR and immunohistochemistry confirmed altered gene expression. CONCLUSION. The gene profiles of normal, small and massive RC tear groups suggested they are biologically distinct groups. In addition to confirming altered gene expression in pathways reported in previous studies, this study has identified a number of novel pathways which are affected between the different tendon tear and normal groups. This study identified that RC tear pathogenesis is contributed to by ECM remodeling genes, chemotaxis genes, aggrecan and amyloid. Further investigation is required to determine whether some of these genes may potentially have a role as biomarkers of failure. Modulating these ECM pathways may be a useful treatment strategy for improving clinical outcomes


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 414 - 414
1 Sep 2012
Chaudhury S Holland C Porter D Vollrath F Carr A
Full Access

Introduction. The pathophysiology of high failure rates following rotator cuff tendon repairs, particularly massive tears, is not fully understood. Collagen structural changes have been shown to alter tendon thermal and mechanical properties. Thermal changes in small biopsies, detected by differential scanning calorimetry (DSC) can help to quantify collagen structural differences in torn rotator cuff tendons. This study aimed to form a quantitative rather than qualitative assessment, of whether differences in collagen structure and integrity existed between small biopsies of normal, small and massive rotator cuff tears using DSC. Methods. Thermal properties were measured for 27 human biopsies taken intra-operatively from normal, small, and massive rotator cuff tendon tears. 3 samples were taken from each patient and subjected to a modulated temperature ramp between 20–80°C at a rate of 2°C per minute with 0.318°C amplitude. The melting temperature (TM) is proposed to represent amide-amide hydrogen bond breakage and resulting protein backbone mobility. Denaturing temperature (TD) reportedly corresponds to the temperature at which the proteins fall out of solution. Denaturation enthalpy (H) should correlate with the amount of triple helical structure. Based upon a pre-study power calculation, this study had 90% power to detect a 10% difference in melting and denaturation temperature between groups with alpha=0.05. 1 specimen per patients was also frozen and cryosectioned and polarised light microscopy was used for quantitative validation. The effect of tear size on heat related parameters were performed using a one-way ANOVA test. A student's unpaired t-test was used to search for differences between individual groups (small tears, massive tears and normal tendons). Results. Small and massive rotator cuff tears had significantly higher melting temperature (TM), and denaturation enthalpy (H) compared to controls. The denaturing temperature (TD) was higher in the massive tears only compared to normal tears. No difference was detected between small and massive tears. Histology of massive tendon tears confirmed greater collagen structural disruption compared to small tears and controls. Conclusion. These novel findings suggest greater quantifiable collagen structural disruption in rotator cuff tears, compared to controls. A decrease in important thermal properties of torn tendons suggests that the material is intrinsically less stable. It is likely that torn tendons cannot withstand changes in temperature or stress as well as a perfect material could, particularly for massive tears which are more amenable to denaturation. This study offers insight into possible mechanisms for, or adaptation to, failure in tears and reduced strength


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 778 - 785
1 Jun 2008
Varitimidis SE Basdekis GK Dailiana ZH Hantes ME Bargiotas K Malizos K

In a randomised prospective study, 20 patients with intra-articular fractures of the distal radius underwent arthroscopically- and fluoroscopically-assisted reduction and external fixation plus percutaneous pinning. Another group of 20 patients with the same fracture characteristics underwent fluoroscopically-assisted reduction alone and external fixation plus percutaneous pinning. The patients were evaluated clinically and radiologically at follow-up of 24 months. The Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire and modified Mayo wrist score were used at 3, 9, 12 and 24 months postoperatively. In the arthroscopically- and fluoroscopically-assisted group, triangular fibrocartilage complex tears were found in 12 patients (60%), complete or incomplete scapholunate ligament tears in nine (45%), and lunotriquetral ligament tears in four (20%). They were treated either arthroscopically or by open operation. Patients who underwent arthroscopically- and fluoroscopically-assisted treatment had significantly better supination, extension and flexion at all time points than those who had fluoroscopically-assisted surgery. The mean DASH scores were similar for both groups at 24 months, whereas the difference in the mean modified Mayo wrist scores remained statistically significant. Although the groups are small, it is clear that the addition of arthroscopy to the fluoroscopically-assisted treatment of intra-articular distal radius fractures improves the outcome. Better treatment of associated intra-articular injuries might also have been a reason for the improved outcome


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 296 - 296
1 Sep 2012
Cantin O Cantin O Chouteau J Henry J Viste A Fessy M Moyen B
Full Access

Introduction. There is a challenge to detect partial tear of the ACL, the number of bundle injured and the proportion of fibers torn. The MRI was shown efficient to individualize the two anteromedial (AM) and posterolateral (PL) bundles of the ACL. The purpose of this study was to assess the ability of the MRI to detect partial tears of the ACL on axial views to display the AM and PL bundles. Materials and methods. This retrospective study included 48 patients (19 partial tears of the ACL, 16 complete rupture of the ACL and 13 normal knee) who underwent both arthroscopy and MRI examinations of the knee. The conventional MRI protocol included one sagittal T1- weighted sequence and 3 proton-density fat sat. The images from MRI were analysis by a radiologist specialized in musculoskeletal imaging who was blinding to the arthroscopic findings. The criteria for the analysis of MRI were divided into primary (those involving the ACL himself) and secondary signs (associated abnormalities). The primary signs included the horizontalisation of the ACL (ACL axis), the global ACL signal intensity and the signal intensity of each AM and PL bundle. The secondary signs included bone bruise, osteochondral impaction, popliteus muscle injury, medial collateral ligament injury and joint effusion. The ACL was classified as normal, partially or totally torn. The rupture of the AM and PL bundle was specified. Results. In our study, MRI was found to have a 75% sensitivity and a 73% specificity for the diagnosis of partial tears of the ACL. The sensitivity to detect AM bundle lesion was 88% but the specificity was 50%. The lack of horizontalisation of the ACL was a very good sign, for partial tears of the ACL, with a sensitivity of 84% and a specificity of 81% (p<0.05). Regarding the secondary signs, there was no significant difference to distinguish partial and complete tear. However, we found that there was a greater probability to find a partial tear of the ACL with the lack of joint effusion, bone bruise and medial collateral ligament injury. Quantifying the proportion of injured fibers was unsuccessful and was found as a failure of the MRI. Conclusions. MRI exhibited lower sensitivity and specificity for partial tear than for complete rupture of the ACL. However 3 important arguments can guide us: the lack of horizontalisation of the ACL, a continuous ACL signal, the display of one of two bundles on the axial view


Bone & Joint Open
Vol. 5, Issue 2 | Pages 117 - 122
9 Feb 2024
Chaturvedi A Russell H Farrugia M Roger M Putti A Jenkins PJ Feltbower S

Aims

Occult (clinical) injuries represent 15% of all scaphoid fractures, posing significant challenges to the clinician. MRI has been suggested as the gold standard for diagnosis, but remains expensive, time-consuming, and is in high demand. Conventional management with immobilization and serial radiography typically results in multiple follow-up attendances to clinic, radiation exposure, and delays return to work. Suboptimal management can result in significant disability and, frequently, litigation.

Methods

We present a service evaluation report following the introduction of a quality-improvement themed, streamlined, clinical scaphoid pathway. Patients are offered a removable wrist splint with verbal and written instructions to remove it two weeks following injury, for self-assessment. The persistence of pain is the patient’s guide to ‘opt-in’ and to self-refer for a follow-up appointment with a senior emergency physician. On confirmation of ongoing signs of clinical scaphoid injury, an urgent outpatient ‘fast’-wrist protocol MRI scan is ordered, with instructions to maintain wrist immobilization. Patients with positive scan results are referred for specialist orthopaedic assessment via a virtual fracture clinic.


Bone & Joint Open
Vol. 4, Issue 8 | Pages 602 - 611
21 Aug 2023
James HK Pattison GTR Griffin J Fisher JD Griffin DR

Aims

To evaluate if, for orthopaedic trainees, additional cadaveric simulation training or standard training alone yields superior radiological and clinical outcomes in patients undergoing dynamic hip screw (DHS) fixation or hemiarthroplasty for hip fracture.

Methods

This was a preliminary, pragmatic, multicentre, parallel group randomized controlled trial in nine secondary and tertiary NHS hospitals in England. Researchers were blinded to group allocation. Overall, 40 trainees in the West Midlands were eligible: 33 agreed to take part and were randomized, five withdrew after randomization, 13 were allocated cadaveric training, and 15 were allocated standard training. The intervention was an additional two-day cadaveric simulation course. The control group received standard on-the-job training. Primary outcome was implant position on the postoperative radiograph: tip-apex distance (mm) (DHS) and leg length discrepancy (mm) (hemiarthroplasty). Secondary clinical outcomes were procedure time, length of hospital stay, acute postoperative complication rate, and 12-month mortality. Procedure-specific secondary outcomes were intraoperative radiation dose (for DHS) and postoperative blood transfusion requirement (hemiarthroplasty).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 364 - 364
1 Sep 2012
Viswanath A Buchanan J Apthorp L
Full Access

Shoulder pain or loss of normal range of motion is a frequent complaint in the outpatient clinic. Of these presentations, rotator cuff injury is a common cause. This can range from mild, transient inflammation of the tendons, to partial tears of tendons, or even full thickness tears. Disruption of the tendons can occur from forceful forward throwing actions undertaken in some sports, for example baseball pitching, more commonly in the UK however, chronic impingement can lead eventually to a tendon tear-usually seen in an older population. Current methods of investigation of such injuries after clinical history and examination, includes plain film radiography, ultrasonography, magnetic resonance imaging and arthrography. We decided to look at how ultrasound can be used in the district general hospital for investigation of such injuries. Aims. To determine the accuracy of ultrasound as an investigative tool for clinically suspected rotator cuff tears. Methods. Seventy-five consecutive ultrasonographic study reports, in patients who subsequently underwent arthroscopic examination, were scrutinised and correlated with surgical findings. From this, sensitivity and specificity of ultrasound at this district general hospital were calculated. In addition, this data was compiled for each of the three Consultant Radiologists in order to assess the operator dependent nature of ultrasound. Results. Of the 74 cases analysed, 43 (58.1%) had full correlation with the arthroscopy findings, 13 (17.6%) had mixed correlation, and 18 cases (24.3%) had no correlation between the ultrasound and arthroscopy report. The sensitivity and specificity of ultrasound at our institution was 0.76 and 0.8 respectively with regards to a tear being detected at ultrasound and then visualised during surgery. Conclusions. There is no current national guidance as to which imaging modality should be first line following clinical examination. Magnetic resonance arthrography, widely thought of as being the gold standard investigation, is not only expensive and possible only in certain centres, but is also invasive, time consuming, and has many relative contraindications. Ultrasound offers a clinical advantage by allowing the radiologist to speak to the patient and assess their range of motion whilst performing the study. This interaction is lost totally in MRI, CT and even MR arthrography. Our study shows that ultrasonography can be quite accurate in identifying a rotator cuff tear. Although it is operator-dependent, ultrasound should be considered more often as a first-line imaging tool for suspected rotator cuff tears as it is relatively inexpensive, quick, and most importantly dynamic


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_3 | Pages 1 - 1
1 Feb 2020
Leow J Krahelski O Keenan O Clement N McBirnie J
Full Access

The treatment of massive rotator cuff tears remains controversial. There is lack of studies comparing patient-reported outcomes (PROM) of arthroscopic massive rotator cuff repairs (RCR) against large, medium and small RCRs. Our study aims to report the PROM for arthroscopic massive RCR versus non-massive RCR. Patients undergoing an arthroscopic RCR under a single surgeon over a 5-year period were included. Demographic data were recorded. Pre-operative Quick-DASH and Oxford Shoulder Score (OSS) were prospectively collected pre-operatively and at final review (mean of 18 months post-operatively). The scores were compared to a matched cohort of patients who had large, medium or small RCRs. A post-hoc power analysis confirmed 98% power was achieved. 82 patients were included in the study. 42 (51%) patients underwent massive RCR. The mean age of patients undergoing massive RCR was 59.7 and 55% (n=23) were female. 21% of massive RCRs had biceps augmentation. Quick-DASH improved significantly from a mean of 46.1 pre-operatively to 15.6 at final follow-up for massive RCRs (p<0.001). OSS improved significantly from a mean of 26.9 pre-operatively to 41.4 at final follow up for massive RCRs (p<0.001). There was no significant difference in the final Quick-DASH and OSS scores for massive and non-massive RCRs (p=0.35 and p=0.45 respectively). No revision surgery was required within the minimum one year follow up timescale. Arthroscopic massive rotator cuff repairs have no functional difference to non-massive rotator cuff repairs in the short term follow up period and should be considered in appropriate patient groups


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 25 - 25
1 Sep 2012
Sadoghi P Vavken P Leithner A Müller P Hochreiter J Weber G
Full Access

Introduction. Insufficient arthroscopic cuff tear reconstruction leading to massive osteoarthritis and irreparable rotator cuff tears might be salvaged by implantation of an inverted total shoulder prosthesis Delta in the elderly. However, despite the generally high success rate and satisfying clinical results of inverted total shoulder arthroplasty, this treatment option has potential complications. Therefore, the objective of this study was a prospective evaluation of the clinical and radiological outcome after a minimum of 2 years follow-up of patients undergoing inverted shoulder replacement with or without prior rotator cuff repair. Patients and Methods. Sixty-eight shoulders in 66 patients (36 women and 30 men) operated between February 2002 and June 2007 with a mean age of 66 years (ranging from 53 to 84 years) were first assessed preoperatively and then at minimum 2 years follow-up, using the Constant score for pain, Constant Shoulder Score, Oxford Shoulder Score, UCLA Shoulder rating scale, DASH Score, Rowe Score for Instability and Oxford Instability Score. 29 patients (Group A) had undergone previous shoulder arthroscopy for cuff tear reconstruction at a mean of 29 months (range 12 to 48 months) before surgery and 39 patients (Group B) underwent primary implantation of an inverted total shoulder prosthesis Delta. Any complications in both groups were assessed according to Goslings and Gouma. Results. We report statistically significant improvements of all obtained scores at a mean follow-up of 42 months (ranging from 24 to 96 months) in both groups. Significant outcome differences between 29 patients with previous shoulder arthroscopy for cuff tear reconstruction and 39 without previous shoulder arthroscopy were not observed. Eight complications occurred altogether, in terms of a nerve lesion once, loosening of the humeral stem three times, and loosening or fracture of the glenoid component four times. Conclusion. We did not detect any statistically significant impact of previous insufficient shoulder arthroscopy for cuff tear reconstruction on the outcome and survival rate after the implantation of the inverted total shoulder prosthesis Delta. We conclude that reverse total shoulder arthroplasty with the Delta prosthesis is significantly beneficial in terms of less shoulder pain, higher stability and gain of range of motion without this beneficial effect being significantly weakened by previous insufficient shoulder arthroscopy for cuff tear reconstruction. We believe that previous arthroscopic cuff tear reconstruction should therefore be included in the treatment algorithm


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 419 - 419
1 Sep 2012
Chaudhury S Ferguson D Hakimi O Carr A
Full Access

INTRODUCTION. In order to address high failure rates following rotator cuff repairs, a greater understanding is required of the underlying structural changes so that treatments can be appropriately targeted and biomarkers of failure can be identified. As collagen is the primary constituent of tendon and determines force transmission, collagen structural changes may affect responses to loading. For example changes in collagen 1 and 5 are associated with the hyperelastic Ehlers-Danlos syndrome, which is diagnosed by looking for pathopneumonic altered collagen fibres or ‘collagen flowers’ in skin using transmission electron microscopy (TEM). To date no study has been performed on the microstructure of torn human rotator cuff tendons using TEM. It was hypothesized that normal, small and massive human rotator cuff tendons tears will have altered microscopic structures. The unique study aimed to use TEM to compare the ultrastructure of small and massive rotator cuff tears, to normal rotator cuff tendons. METHODS. Samples from 7 human rotator cuff tendons repairs were obtained, including 4 massive (>5 cm) and 3 small (< 1 cm) tears, and 3 matched normal controls with no history of connective tissue disorders. Specimens were fixed in 4% glutaraldehyde in 0.1M phosphate buffer, processed and examined blind using routine TEM examination. To assess whether changes in the relative expression of collagen 1 and 5 (COL1A1, COL5A1 and COL5A2) occurred in all tears, qPCR was performed on another 6 phenotypically matched patients. RESULTS. The basic structure of the normal tendon consisted of tightly packed clumps of dense packed parallel running collagen fibers with few fibroblasts and small amounts of fine filamentous material between clumps. In contrast, torn samples were more variable with areas of less dense packing of collagen fibers and larger areas of filamentous material plus variable numbers of lipid droplets both within the fibroblast and between the collagen bundles. There was also evidence of twisting and random orientation of individual collagen fibers. All torn tendons showed evidence of a proportion of the fibers within the collagen bundles being enlarged with a serrated outline, similar in appearance to ‘collagen flowers’. Clear differences between the small and massive tears were not identified. qRT-PCR of torn rotator cuff tendon specimens demonstrated no altered collagen expression compared to normal tendons. DISCUSSION. This novel study has identified the previously unreported presence of atypical collagen fibers with focal swelling resulting in the appearance of ‘collagen flowers’ in torn rotator cuff tendons only. This appearance is considered pathognomonic of Ehlers-Danlos syndrome, classical type 1 and 2. Torn tendons also showed an increase in filamentous material, and infiltration with fat droplets. These novel findings may offer insight into the mechanisms of structural damage that contribute to rotator cuff failure. Further examination is required, to evaluate the significance of these observations


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 462 - 462
1 Sep 2012
Lakemeier S Reichelt J Foelsch C Fuchs-Winkelmann S Schofer M Paletta J
Full Access

Introduction. Differing levels of tendon retraction are found in full-thickness rotator cuff tears. The pathophysiology of tendon degeneration and retraction is unclear. Neoangiogenesis in tendon parenchyma indicates degeneration. Hypoxia inducible factor 1(HIF) and vascular endothelial growth factor (VEGF) are important inducers of neoangiogenesis. Rotator cuff tendons rupture leads to fatty muscle infiltration (FI) and muscle atrophy (MA). The aim of this study is to clarify the relationship between HIF and VEGF expression, neoangiogenesis, FI, and MA in tendon retraction found in full-thickness rotator cuff tears. Methods. Rotator cuff tendon samples of 33 patients with full-thickness medium-sized rotator cuff tears were harvested during reconstructive surgery. The samples were dehydrated and paraffin embedded. For immunohistological determination of VEGF and HIF expression, sample slices were strained with VEGF and HIF antibody dilution. Vessel density and vessel size were determined after Masson-Goldner staining of sample slices. The extent of tendon retraction was determined intraoperatively according to Patte's classification. Patients were assigned to 4 categories based upon Patte tendon retraction grade, including one control group. FI and MA were measured on standardized preoperative shoulder MRI. Results. HIF and VEGF expression, FI, and MA were significantly higher in torn cuff samples compared with healthy tissue (p<0.05). HIF and VEGF expression, and vessel density significantly increased with extent of tendon retraction (p<0.04). A correlation between HIF/VEGF expression and FI and MA could be found (p<0.04). There was no significant correlation between HIF/VEGF expression and neovascularity (p>0.05). Conclusion. Tendon retraction in full-thickness medium-sized rotator cuff tears is characterized by neovascularity, increased VEGF/HIF expression, FI, and MA. VEGF expression and neovascularity may be effective monitoring tools to assess tendon degeneration


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 461 - 461
1 Sep 2012
Ciampi P Vitali M Fraschini G
Full Access

The aim is to evaluate the effectiveness of pericardium patch as a tendon augmentation graft in the repair of massive rotator cuff tear. This is prospective study analysis of a consecutive series of 60 patients who underwent open repair of a massive rotator cuff tear with patch between 1999 and 2007. The inclusion criteria were: symptomatic with pain, deficit of elevation, not responsive to the physiotherapy, tear size (massive: 2 or more tendons), minimum follow-up of 2 years since surgery, active and motivated patients. All were assessed preoperatively with plain radiographs (anteroposterior and axillary views), ultrasound and NMR of the shoulder. The study group consistent of 60 patients (39 men and 21 women) with the mean age of was 66 years (range, 46–81). The mean duration of symptoms before repair was 18 months (range 3–48). Patients were assessed with UCLA score, visual analog scale (Vas scale) and ultrasound preoperatively, at 1 year, and at 3 years. The change in UCLA scores, Vas scale were analyzed with the paired Student's test, assuming a normal distribution of the total score. Satisfactory results were achieved in 49 patients: mean preoperative UCLA score improved from 9.3 to 16.9 at final follow-up. For pain, the mean preoperative value of Vas scale was 9,1, postoperative mean value was 4.9. Range of motion and abduction power improved not significantly after surgery, although patients satisfaction levels were high. Imaging studies identified intact patch in 15 patients and patch detachment in 45. No adverse side effects (infection, rejection, allergy) were reported during the study period. The results of our study suggest that patients (appropriately selected) with a massive full-thickness rotator cuff tear can be expected to have a pain relief after repair, but not a significantly improved of functional outcome


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_8 | Pages 10 - 10
1 Feb 2013
Guyver P Jaques A Goubran A Smith C Bunker T
Full Access

Introduction. Massive rotator cuff tears in the patient who is too young for a reverse shoulder replacement are a challenging situation. A technique using a ‘Grammont osteotomy’ of the acromion has been developed to allow a comprehensive approach, the so called “Full Monty”. Aim. To document the functional outcome of patients undergoing an acromial osteotomy for the repair of massive tears of the supraspinatus. Methods. Ten patients undergoing this procedure where entered in to the study. The mean age of the patients was 57 years (+/−16) and all bar one were male. Each patient had a pre-operative American Shoulder Elbow Score (ASES), Oxford Shoulder score (OSS), and range of movement documented. These outcome measures were repeated at a minimum of two years, as well as a patient satisfaction questionnaire. Results. The mean ASES preoperatively was 7(+/− 6) and 23(+/−3) post-operatively (p< 0.001). The mean pre-operative OSS was 22(+/−5) and 43(+/−4) post-operatively (p<0.001). 80% of patients deemed their treatment to be “successful” and 90% would recommend the procedure to a friend in the same plight. The mean post-operative forward flexion achieved was 153° (+/−58) and the mean abduction was 142° (+/−37). All patients could sustain a 1kg weight at arms length at 90° of abduction. One patient suffered a superficial wound infection and one patient had a non-union at the osteotomy site. Conclusion. These results suggest that this technique is a good surgical option for a patient with a “massive” rotator cuff tear that is not amenable to standard surgical techniques


Introduction. Reverse shoulder replacement is a surgical option for cuff tear arthropathy. However scapular notching is a concern. Newer designs of glenospheres are available to reduce scapular notching. Eccentric glenosphere with a lowered centre of rotation have been shown to improve range of adduction in vitro. We hypothesize that the eccentric glenosphere improve clinical outcomes and reduce scapular notching. Method. This is an ongoing randomized controlled double blind prospective clinical trial. Patients 70 years or older at North Shore hospital who have a diagnosis of cuff tear arthropathy and require surgery were consented for this study. Patients were allocated a concentric or eccentric 36 mm glenosphere intraoperatively, using a computer generated randomization contained in a sealed envelope. The surgical technique and post operative rehabilitation were standardized. Patients were followed up by a research nurse and postoperative radiographs were also taken at regular intervals. Clinical assessment include a visual analogue pain score, subjective shoulder rating, American Shoulder and Elbow Society Score, and Oxford shoulder score. Complications were checked for and radiographs were assessed for scapular notching. Results. There were 23 patients in the concentric and 24 patients in the eccentric glenosphere group. Average age and duration of follow up were comparable. There was no statistical significant difference but there was a trend towards better functional outcome and better range of motion in the eccentric glenosphere group. There was no scapular notching in the eccentric and three cases of scapular notching in the concentric glenosphere group. Conclusions. Reverse shoulder replacement significantly improve pain, function and range of motion in patients with cuff tear arthropathy. Eccentric glenosphere prevents scapular notching in the SMR reverse prosthesis


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 451 - 451
1 Sep 2012
Visoná E Godenèche A Nové-Josserand L Neyton L Hardy M Piovan G Aldegheri R Walch G
Full Access

PURPOSE. We performed an anatomical study to clarify humeral insertions of coracohumeral ligament (CHL) and superior glenohumeral ligament (SGHL) and their relationship with subscapularis tendon. The purpose of our study was to explain the « Comma Sign » observed in retracted subscapularis tears treated by arthroscopy. MATERIAL AND METHODS. 20 fresh cadaveric shoulders were dissected by wide delto-pectoral approach. After removal the deltoid and posterior rotator cuff, we removed humeral head on anatomical neck. So we obtained an articular view comparable to arthroscopical posterior portal view. We looked for a structure inserted on subscapularis tendon behind SGHL. By intra-articular view we removed SGHL and CHL from the medial edge of the bicipital groove, then subscapularis tendon from lesser tuberosity. We splitted the rotators interval above the superior edge of subscapularis tendon and observed the connections between subscapularis tendon, CHL and SGHL. RESULTS. 6 shoulders had massive cuff tears and were excluded. No ligamentous structure was visible between rotators interval and subscapularis tendon by simple intra and extra-articular examination. After removal of LGHS humeral insertion, no structure showed vertical attach on tendon yet. But after removal of subscapularis tendon from lesser tuberosity and medial traction we saw constantly a fibers bundle directly inserted onto supero-lateral edge of subscapularis tendon. DISCUSSION/CONCLUSION. Most authors agree about existence of CHL and SGHL and their bone insertions, whereas relations between themselves and subscapularis tendon aren't so well defined. We constantly found an effective link between subscapularis tendon and a fibers bundle mainly coming from LCH. It layed into supero-lateral edge of subscapularis tendon and could be seen only by medial traction of it. This ligamentous structure yields the « Comma Sign » in subscapularis tendon tears. This study confirms our clinical datas