Objectives. In total hip arthroplasty (THA), the cementless,
Background. Short stem has potential advantages of bone and muscle preservation. Current papers demonstrate that direct anterior approach (DAA) is a significant minimally invasive muscle-sparing approach to total hip arthroplasty. Theoretically, a short length stem with a reduced lateral shoulder is the most appropriate design for DAA. Objectives. To clarify the necessity of the standard length
Introduction. Micro-arc oxidation (MAO) is an electrochemical method used to treat metal surfaces. It provides nanoporous pits, and thick oxide layers, and incorporates calcium and phosphorus into the coating layer of titanium alloy. This modification on the surface of titanium alloy by MAO coating would improve the ability of cementless stems to osseointegrate. In spite of these structural and chemical advantages, clinical study of total hip arthroplasty (THA) using MAO coated stem has not yet been reported. In this study, we evaluated the clinical and radiographic results associated with cementless grit-blasted
Purpose. The purpose of this study was to evaluate periprosthetic bone mineral density (BMD) changes around a cementless short
Introduction. Resorptive bone remodeling secondary to stress shielding has been a concern associated with cementless total hip arthroplasty (THA). At present, various types of cementless implants are commercially available. The difference in femoral stem design may affect the degree of postoperative stress shielding. In the present study, we aimed to compare the difference in bone mineral density (BMD) change postoperatively in femurs after the use of 1 of the 3 types of cementless stems. Methods. Ninety hips of 90 patients who underwent primary cementless THA for the treatment of osteoarthritis were included in this study. A fit-and-fill type stem was used for 28 hips, a tapered-rectangular Zweymüller type stem was used for 32 hips, and a
Short stems have been developed to conserve bone stock, especially in younger populations undergoing a total hip arthroplasty (THA), and showed similar functional outcomes compared to conventional stems. Recent literature suggested that stem length might be an independent risk factor for acute periprosthetic femoral fracture in direct anterior THA (1) or with different short stem designs (2). The purpose of the present study was to compare the incidence of acute periprosthetic femoral fractures, between stems of the same manufacture (Taperloc microplasty vs Taperloc complete), which have the same stem characteristics, except for the stem length which is 35 mm shorter in Taperloc microplasty during posterior and lateral THA. Our institution's arthroplasty database was searched for all primary total hip arthroplasties utilizing short femoral stems performed between August 2016 and August 2023. Pre-operative X-rays for each case were analysed to characterize the proximal femoral geometry, specifically the canal bone ratio (CBR) and canal flare index (CFI). Data analysis was performed to identify risk factors for periprosthetic fractures. For the time period assessed, 2107 femoral stems (Taperloc Microplasty:1727, Taperloc complete: 380) were implanted. Females constituted 53% of the cohort. The average patient age was 70±11 years. The periprosthetic fracture rate was 0.94%, with 20 periprosthetic fractures (Taperloc Microplasty:17, Taperloc complete: 3) excluding 2 greater trochanteric fractures (1 at each group), identified at follow-up of three months. There was no significant difference between the periprosthetic fracture rates between the two stems (0.98% vs 0.79%, p>0.72) The multivariate regression analysis demonstrated that the stem length, CBR, CFI, age, and gender were not risk factors for periprosthetic fracture. The present study demonstrated that both Taperloc Microplasty and Taperloc complete stems had similar rates of periprosthetic fractures, and the stem length was not a risk factor for a periprosthetic fracture during uncemented THA. 1. Tamaki T, Cementless
Introduction. Cementless grit-blasted tapered-wedge titanium femoral stems are being used with increasing frequency in hip arthroplasty because of excellent long-term outcomes. However, periprosthetic femur fracture is a potentially worrisome phenomenon in these types of femoral stems. The aim of this study is to report the incidence of stem loosening in association with periprosthetic femur fractures following hip arthroplasty using cementless grit-blasted
Background. In total hip arthroplasty (THA), the importance of preserving muscles is widely recognized; therefore, muscle-sparing approaches are widely used. Recently, we reported that there are bony impressions, that we called the obturator attachment (OA), on the greater trochanter that indicate the insertions of the short external rotator tendons. In this study, we used a three-dimensional (3-D) template to evaluate damage to the insertions of the short external rotator muscles during a femoral procedure. Methods. We investigated 12 hips in 10 patients who underwent THA. Preoperative CT imaging of the hip was performed, and 3-D reconstruction of the greater trochanter was used to visualize the bony impressions that indicate the insertions of the obturator internus and externus muscles (Fig 1A). We performed preoperative 3-D templating of two different femoral prosthesis (flat
There are concerns regarding initial stability and early periprosthetic fractures in cementless hip arthroplasty using short stems. This study aimed to investigate stress on the cortical bone around the stem and micromotions between the stem and cortical bone according to femoral stem length and positioning. In total, 12 femoral finite element models (FEMs) were constructed and tested in walking and stair-climbing. Femoral stems of three different lengths and two different positions were simulated, assuming press-fit fixation within each FEM. Stress on the cortical bone and micromotions between the stem and bone were measured in each condition.Aims
Methods