Advertisement for orthosearch.org.uk
Results 1 - 18 of 18
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 51 - 51
1 Mar 2021
Harris A O'Grady C Sensiba P Vandenneucker H Huang B Cates H Christen B Hur J Marra D Malcorps J Kopjar B
Full Access

Outcomes for guided motion primary total knee arthroplasty (TKA) in obese patients are unknown. 1,684 consecutive patients underwent 2,059 primary TKAs with a second-generation guided motion implant between 2011–2017 at three European and seven US sites. Of 2,003 (97.3%) TKAs in 1,644 patients with BMI data: average age 64.5 years; 58.4% females; average BMI 32.5 kg/m2; 13.4% had BMI ≥ 40 kg/m2. Subjects with BMI ≥ 40 kg/m2 had longest length of hospital stay (LOS) at European sites; LOS similar at US sites. Subjects with BMI ≥ 40 kg/m2 (P=0.0349) had longest surgery duration. BMI ≥ 40 kg/m2 had more re-hospitalizations or post-TKA reoperations than BMI < 40 kg/m2 (12.7% and 9.2% at five-year post-TKA, P<0.0495). Surgery duration and long-term complication rates are higher in patients with BMI ≥ 40 kg/m2, but device revision risk is not elevated


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 102 - 102
11 Apr 2023
Mosseri J Lex J Abbas A Toor J Ravi B Whyne C Khalil E
Full Access

Total knee and hip arthroplasty (TKA and THA) are the most commonly performed surgical procedures, the costs of which constitute a significant healthcare burden. Improving access to care for THA/TKA requires better efficiency. It is hypothesized that this may be possible through a two-stage approach that utilizes prediction of surgical time to enable optimization of operating room (OR) schedules. Data from 499,432 elective unilateral arthroplasty procedures, including 302,490 TKAs, and 196,942 THAs, performed from 2014-2019 was extracted from the American College of Surgeons (ACS) National Surgical and Quality Improvement (NSQIP) database. A deep multilayer perceptron model was trained to predict duration of surgery (DOS) based on pre-operative clinical and biochemical patient factors. A two-stage approach, utilizing predicted DOS from a held out “test” dataset, was utilized to inform the daily OR schedule. The objective function of the optimization was the total OR utilization, with a penalty for overtime. The scheduling problem and constraints were simulated based on a high-volume elective arthroplasty centre in Canada. This approach was compared to current patient scheduling based on mean procedure DOS. Approaches were compared by performing 1000 simulated OR schedules. The predict then optimize approach achieved an 18% increase in OR utilization over the mean regressor. The two-stage approach reduced overtime by 25-minutes per OR day, however it created a 7-minute increase in underutilization. Better objective value was seen in 85.1% of the simulations. With deep learning prediction and mathematical optimization of patient scheduling it is possible to improve overall OR utilization compared to typical scheduling practices. Maximizing utilization of existing healthcare resources can, in limited resource environments, improve patient's access to arthritis care by increasing patient throughput, reducing surgical wait times and in the immediate future, help clear the backlog associated with the COVID-19 pandemic


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 89 - 89
1 Dec 2020
Lentine B Tarka M Schottel P Nelms N Russell S Blankstein M
Full Access

Introduction. Femoral periprosthetic fractures above TKA are commonly treated with retrograde intramedullary nailing (IMN). This study determined if TKA design and liner type affect the minimum knee flexion required for retrograde nailing through a TKA. Methods. Twelve cadaveric specimens were prepared for six single radius (SR) TKAs and six asymmetric medial pivot (MP) TKAs. Trials with 9mm polyethylene liners were tested with cruciate retaining (CR), cruciate substituting (CS) and posterior stabilizing (PS) types. The knee was extended to identify the minimum knee flexion required to allow safe passage of the opening reamer while maintaining an optimal fluoroscopic starting point for retrograde nailing. Furthermore, the angle of axis deviation between the reamer and the femoral shaft was calculated from fluoroscopic images. Results. In all specimens, the reamer entry point was posterior to Blumensaat's line. In the SR TKA, the average flexion required was 70, 71 and 82 degrees for CR, CS and PS respectively. The required flexion in PS was significantly greater than the other designs (p=0.03). In the MP TKA, the average flexion required was 74, 84 and 123 degrees for CR, CS and PS respectively. The required flexion was significantly greater in CS and PS designs (p<0.0001). Femoral component size did not affect the minimum flexion required. Furthermore, the entry reamer required 9.2 (SR) and 12.5 (MP) degrees of posterior axis deviation from the femur. Conclusions. Our study illustrates four novel factors to consider when performing retrograde nailing through TKA. First, significant knee flexion is required to obtain an ideal radiographic starting point when retaining the liner. Second, PS implants require more flexion with both TKA designs. Third, femoral component size does not affect the flexion required. Fourth, there is a consistent posterior axis deviation of the entry reamer from the femoral shaft, explaining the commonly created extension deformity


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 104 - 104
1 Nov 2021
Camera A Tedino R Cattaneo G Capuzzo A Biggi S Tornago S
Full Access

Introduction and Objective. Difficult primary total knee arthroplasty (TKA) and revision TKA are high demanding procedures. Joint exposure is the first issue to face off, in order to achieve a good result. Aim of this study is to evaluate the clinical and radiological outcomes of a series of patients, who underwent TKA and revision TKA, where tibial tubercle osteotomy (TTO) was performed. Materials and Methods. We retrospectively reviewed a cohort of 79 consecutives TKAs where TTO was performed, from our Institution registry. Patients were assessed clinically and radiographically at their last follow-up (mean, 7.4 ± 3.7 years). Clinical evaluation included the Knee Society Score (KSS), the pain visual analogue scale (VAS), and range of motion. Radiological assessment included the evaluation of radiolucent lines, osteolysis, cortical bone hypertrophy, time of bone healing of the TTO fragment, and the hardware complication. Results. KSS raised from 40.7 ± 3.1 to 75 ± 4.3 (p < 0.0001). Knee flexion increased from 78.7 ± 9.9° to 95.0 ± 9.5° (p < 0.0001), and VAS improved from 7.9 ± 0.9 to 3.8 ± 1 (p < 0.0001). No signs of loosening or evolutive radiolucency lineswere found. Osteolytic areas around the stem were detected. No significant association was found between the implant design and the outcomes, while aseptic loosening showed significantly better results. Complications were: 4 painful hardware, 3 late periprosthetic infections, 1 extension lag of 5°, and 3 flexion lag. Conclusions. Our experience suggests the use of TTO to improve the surgical approach in difficult primary TKA or revision TKA. A strict surgical technique leads to good results with low risk of complications


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 52 - 52
1 Mar 2021
Harris A O'Grady C Sensiba P Vandenneucker H Huang B Cates H Christen B Hur J Marra D Malcorps J Kopjar B
Full Access

Patients ≤ 55 years have a high primary TKA revision rate compared to patients >55 years. Guided motion knee devices are commonly used in younger patients yet outcomes remain unknown. In this sub-group analysis of a large multicenter study, 254 TKAs with a second-generation guided motion knee implant were performed between 2011–2017 in 202 patients ≤ 55 years at seven US and three European sites. Revision rates were compared with Australian Joint Registry (AOANJRR) 2017 data. Average age 49.7 (range 18–54); 56.4% females; average BMI 34 kg/m2; 67.1% obese; patellae resurfaced in 98.4%. Average follow-up 4.2 years; longest follow-up six years; 27.5% followed-up for ≥ five years. Of eight revisions: total revision (one), tibial plate replacements (three), tibial insert exchanges (four). One tibial plate revision re-revised to total revision. Revision indications were mechanical loosening (n=2), infection (n=3), peri-prosthetic fracture (n=1), and instability (n=2). The Kaplan-Meier revision estimate was 3.4% (95% C.I. 1.7% to 6.7%) at five years compared to AOANJRR rate of 6.9%. There was no differential risk by sex. The revision rate of the second-generation guided motion knee system is lower in younger patients compared to registry controls


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 47 - 47
1 Nov 2018
Keohane D Power F Cullen E O'Neill A Masterson E
Full Access

Total knee arthroplasty (TKA) is a common orthopaedic procedure with over 1,500 done in 2016 in Ireland alone. 96% of all TKAs are due to pain in the knee associated with osteoarthritis. According to the UK National Joint Registry (NJR), there is a 0.47%, 1.81%, 2.63% and 4.34% probability risk of undergoing a revision TKA within one, three, five and ten years respectively post-index surgery. A variety of reasons for failure of TKA have been described in the literature including infection, aseptic loosening, pain, instability, implant wear, mal-alignment, osteolysis, dislocation, peri-prosthetic fracture and implant fracture. The NexGen Posterior Stabilised Fixed has NJR revision rates of 0.44%, 1.61% and 2.54% at years one, three and five respectively. A retrospective review was carried out of 350 NexGen TKAs that were performed directly by, or under the supervision of, a fellowship trained arthroplasty surgeon in a dedicated orthopaedic hospital between April 2013 and December 2015. 26 (7.4%) of these were revised as of 31 December 2017. Three were for septic arthritis with the remaining 23 (6.6%) for aseptic loosening. Patients typically started to experience symptoms of medial tibial pain with supra-patellar swelling from a combination of effusion and synovial thickening at 12–24 months. Inflammatory markers were normal in all cases. Radiographs of symptomatic knee replacements showed bone loss on the medial tibia with a tilt of the tibial component into a varus alignment. The high number of revisions of this particular prosthetic has led to its use being discontinued at this centre


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 101 - 101
1 Nov 2018
Veltman E Lenguerrand E Moojen D Whitehouse M Nelissen R Blom A Poolman R
Full Access

Administration of perioperative antibiotic prophylaxis (AP) reduces the risk of prosthetic joint infection (PJI) following primary total hip (THA) and knee (TKA) arthroplasty. The optimal type of antibiotic used, and duration of prophylaxis are subject to debate. We compared the risk of revision surgery for PJI in the first year following THA and TKA by AP regimen. A national survey collecting information on hospital-level AP regimen policy was conducted across the Netherlands and linked to data from the LROI arthroplasty registry for 2011–2015. PJI status was defined using the surgical indication reported at revision by surgeons in the registry form. Restricted cubic splines Poisson model adjusted for hospital clustering were used to conduct the comparisons on 130,712 THAs and 111,467 TKAs performed across 99 institutions. These included 399 THAs and 303 TKAs revised for an indication of PJI. Multiple shot of Cefazolin (MCZ), of cefuroxime (MCX) and single shot of Cefazolin (SCZ) were respectively administrated to 87%, 4% and 9% of patients. For THA, the rates of revision for PJI were respectively 31/10,000 person-years 95%CI[28, 35], 39[25, 59] and 23[15, 34] in the groups which received MCZ, MCX and SCZ; respectively, the rates for TKA were 27[24, 31], 40[24, 62] and 24[16, 36]. No evidence of difference between AP regimens was found in the unadjusted and adjusted model (age, gender, BMI and ASA grade). Further work is advocated to confirm whether there is an association between AP regimen collected at patient-level and the risk of subsequent revision for PJI


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 6 - 6
1 Aug 2013
Boyd A Soon V Sapare S McAllister J Deakin A Sarungi M
Full Access

Patient reported outcome measures (PROMs) are important for assessing the results of lower limb arthroplasty. Unrealistic or uneducated expectations may have a significant negative impact on PROMs even when surgery is technically successful. This study's aim was to quantify pre-operative expectations of Scottish patients undergoing total hip and knee replacement (THR/TKR). 100 THR and 100 TKR patients completed validated questionnaires (from the Hospital for Special Surgery) prior to their operation after receiving standard pre-operative information (booklet, DVD, consultations). Each patient rated expectations from very important to not having the expectation. A total score was calculated using a numerical scale for the grading of each expectation. Univariate regression analysis was used to investigate the relationship between demographics and expectation score. The THR cohort had mean age 66.2 (SD 10.5), 53% female, mean BMI 29.0 (SD 5.1) and mean Oxford score 44 (SD 7). The TKR cohort had mean age 67.6 (SD 8.5), 59% female, mean BMI 32.8 (SD 5.8) and mean Oxford score 44 (SD 8). 100% THR and 96% TKR patients had 10 or more expectations of their operation. All expected pain relief. Other improvements expected were: walking for 100% THA and 99% TKA patients; daily activities for 100% THAs and 96% TKAs; recreational activities for 96% THAs and 93% TKAs; sexual activity for 66% THAs and 59% TKAs; psychological well-being for 98% THAs and 91% TKAs. Regression analysis showed increasing age lowered expectations in both THR (p=0.025) and TKR (p=0.031) patients but that gender, BMI and Oxford score were not significantly related to expectations. This study highlights that patients expect far more than pain relief and improved post-operative mobility from their operation. It is important to discuss and manage these expectations with patients prior to surgery. By doing so, patient satisfaction and PROMs should further improve


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 55 - 55
1 Apr 2018
Yabuno K Sawada N Hirohaku D
Full Access

Introduction. With the development of 3D printing technology, there are many different types of PSI in the world. The accuracy of patient specific instrumentation (PSI) in primary total knee arthroplasty (TKA) is dependent on appropriate placement of the cutting blocks. However, previous reports on one type of PSI measured the difference between postoperative prosthetic alignment and postoperative mechanical axis and thus these reports did not evaluate intraoperative comparison of PSIs between two different designs. The purpose of this study was to evaluate the intraoperative accuracy of two different designed PSIs (My knee, Medacta International, Castel San Pietro, Switzerland) with two examiners using CT free navigation system (Stryker, Mahwar, NJ, USA) in regards to sagittal and coronal alignment. Methods. We enrolled 78knees (66 patients) with a primary cemented TKA using two different designed CT-based PSIs (My knee, Medacta International, Castel San Pietro, Switzerland). All operations were performed by two senior surgeons who have experience with greater than 500 TKAs and greater than 200 navigated TKAs. Two examiners were same two surgeons. The study period was between June 2015 and November 2016. The local ethics' committee approved the study prior to its initiation, and informed consent was obtained from all patients. After placement of the PSI on the femur and tibia, the position of the PSI was evaluated by s intraoperative navigation. Two examiners placed two different types (STD(standard) and MIS(minimum invasive surgery)) of PSI on same joint. As required by the PSI, only soft- tissue was removed and osteophytes were left in place. Femoral MIS PSI was required partial remove of lateral cartilage. For the femur, the coronal position in relation to the mechanical axis were documented. For the tibia, the coronal alignment and the tibial slope were documented. Of note, intraoperative modifications to the PSI were not made based upon the results of the navigation. Rather, the findings of the intraoperative navigation were simply documented. Results. The mean age of the cohort was 72.9±7.5years (range, 55–85years). The study included 11men and 55women, with a mean height of 151±8.2cm (range, 135–175cm), mean weight of 59.4±4.3kg (range, 42–82kg), and a mean of Body Mass Index of 25.9±3.6 (range, 17.2–36.4). HKA angle (supine position) measured by CT was 170.8 ±4.4 degree(range, 162.5–182degree). Diagnosis was osteoarthritis in all patient. There was no statistically significant difference in PSI position alignment for femoral flexion, tibial coronal angle, tibial slope between the two groups with two examiners. However, the intraoperative coronal position using the femoral STD PSI significantly deviated from using femoral MIS PSI from both examiners. (PSI vs. MIS, examiner1 p = 0.02, examiner2 p=0.04)


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XI | Pages 13 - 13
1 Apr 2012
Al-Janabi Z Basanagoudar P Nunag P Springer T Deakin AH Sarungi M
Full Access

The routine use of a fixed distal femoral resection angle in total knee arthroplasty (TKA) assumes little or no variation in the angle between the anatomical and mechanical femoral axes (FMA angle) in different patients. The aims of this study were threefold, firstly to investigate the distribution of FMA angle in TKA patients, secondly to identify any correlation between the FMA angle and the pre-operative coronal mechanical femoro-tibial (MFT) angle and in addition to assess post-operative MFT angle with fixed or variable distal femoral resection angles. 277 primary TKAs were performed using either fixed or variable distal femoral resection angles (174 and 103 TKAs respectively), with intramedullary femoral and extramedullary tibial jigs. The variable distal femoral resection angles were equal to the FMA angle measured on pre-operative Hip-Knee-Ankle (HKA) digital radiographs for each patient. Outcomes were assessed by measuring the FMA angle and the pre- and post-operative MFT angles on HKA radiographs. The FMA angle ranged from 2° to 9° (mean 5.9°). Both cohorts showed a correlation between FMA and pre-operative MFT angles (fixed: r = -0.499, variable: r = -0.346) with valgus knees having lower FMA angles. Post-operative coronal alignment within ±5° increased from 86% in the fixed angle group to 96% when using a variable angle, p = 0.025. For post-operative limb alignment within ±3°, accuracy improved from 67% (fixed) to 85% (variable), p = 0.002. These results show that the use of a fixed distal femoral resection angle is a source of error regarding post-operative coronal limb malalignment. The correlation between the FMA angle and pre-operative varus-valgus alignment supports the rational of recommending the adjustment of the resection angle according to the pre-operative deformity (3°-5° for valgus, 6°-8° for varus) in cases where HKA radiographs are not available for pre-operative planning


Bone & Joint 360
Vol. 10, Issue 4 | Pages 49 - 51
1 Aug 2021
Evans JT Welch M Whitehouse MR


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 43 - 43
1 Aug 2013
Changulani M Sankar B Deakin A Picard F
Full Access

Distal femur resection for correction of flexion contractures in total knee arthroplasty (TKA) can lead to joint line elevation, abnormal knee kinematics and patellofemoral problems. The aim of this retrospective study was to establish the contribution of soft tissue releases and bony cuts in the change in maximum knee extension in TKA. Data were available for 211 TKAs performed by a single surgeon using a medial approach. Intra-operatively pre- and post-implant extension angles and the size of bone resection were collected using a commercial navigation system. The thickness of polyethylene insert and the extent of soft tissue release performed (no release, moderate and extensive release) were collected from the patient record. A linear model was used to predict change in maximum extension from pre- to post-implant. The analysis showed that bone cuts (p<0.001), soft tissue release (p=0.001) and insert thickness (p=0.010) were all significant terms in the model (r. 2. adj. =0.170). This model predicted that carrying out a TKA with 19 mm bone cuts, 10 mm insert and no soft tissue release would give 4.2° increase in extension. It predicted that a moderate release would give a further 2.8° increase in extension with an extensive release giving 3.9°. For each mm increase in bone cuts the model predicted an 0.8° increase in extension and for each mm increase in insert size a decrease extension by 1.1°. The modelling results show that in general to increase maximum extension by the same as an extensive soft tissue release that bone cuts would have to be increased by 4–5 mm. However this model only accounted for 17% of the variation in change in extension pre- to post-implant so may not be accurate at predicting outcomes for specific patients


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 167 - 167
1 Jul 2014
Iwamoto K Tomita T Yamazaki T Sasaki A Kii Y Futai K Miyamoto T Fujii M Yoshikawa H Sugamoto K
Full Access

Summary. The effect of the geometry of the tibial polyethylene insert was investigated in vivo loaded conditions. Introduction. The decision to choose CR (cruciate retaining) insert or CS (condylar stabilised) insert during TKA remains a controversial issue. Triathlon CS type has a condylar stabilised insert with an increased anterior lip that can be used in cases where the PCL is sacrificed but a PS insert is not used. The difference of the knee kinematics between CR and CS insert remains unclear. This study measured knee kinematics of deep knee flexion under load in two insert designs using 2D/3D registration technique. Patients and Methods. We investigated the in vivo knee kinematics of 20 knees (18 patients) implanted with Triathlon CR components (Stryker Orthopedics, Mahwah, NJ), 10 knees in the CR insert with retaining PCL, and 10 knees in the CS insert with sacrificing PCL. All TKAs were judged clinically successful (Knee Society knee scores >90), with no ligamentous laxity or pain. Mean patient age at the time of operation was 72±12 years in CR and 69±9 years in CS. Mean period between operation and surveillance was 20±11 months in CR and 11±5 months in CS. Under fluoroscopic surveillance, each patient did a wight-bearing deep knee bending motion. Femorotibial motion including tibial polyethylene insert was analyzed using 2D/3D registration technique, which uses computer-assisted design (CAD) models to reproduce the spatial position of the femoral, tibial components from single-view fluoroscopic images. We evaluated the range of motion, femoral axial rotation, and antero-posterior (AP) translation of the nearest points. Results. The average range of motion between femoral component and tibial component was 113.3±22.3° in CR and 107.4±13.1° in CS. The amount of femoral axial rotation from 0° to 110° flexion was 8.6±2.9° in CR insert, and 7.6±2.6° in CS insert, respectively. No significant difference was observed in the amount of femoral external rotation (p=0.71). In CR insert, the medial contact point moved 4.0±2.9mm anteriorly from 0° to 100° flexion. The lateral contact point moved 2.0±1.1mm anteriorly from 60° to 90° flexion. In CS insert, the medial contact point moved 6.4±2.1mm anteriorly from 20° to 100° flexion. The lateral contact point moved 1.9±1.7mm anteriorly from 50° to 110° flexion. There was significant differences were observed in the amount of medial anterior translation between the two insert (medial; p=0.04, lateral; p=0.94). Discussion and Conclusion. Triathlon CR and CS insert had a similar kinematics pattern. However, there was significant differences were observed in the amount of medial anterior translation between the two insert. These results indicated that the increased anterior lip could not control medial anterior sliding. The posterior part of the two insert were almost same, so the kinematics are similar


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 67 - 67
1 Aug 2012
Hamilton D Gaston P Simpson A
Full Access

End-stage osteoarthritis is characterised by pain and reduced physical function, for which total knee arthroplasty (TKA) is recognised to be a highly effective treatment. Most implants are multi radius in design, though modern kinematic theory suggests a single flexion/extension axis is located in the femur. A recently launched TKA implant (Triathlon, Stryker US), is based on this theory, adopting a single radius of curvature femoral component. It is hypothesised that this design allows better function, and specifically, that it results in enhanced efficiency of the quadriceps group through a longer patello-femoral moment arm. Change in power output was compared between single and multi radius implants as part of a larger ongoing randomised controlled trial to benchmark the new implant. Power output was assessed using a Leg Extensor Power Rig, well validated for use with this population, pre-operatively and at 6, 26 and 52 weeks post-operatively in 101 Triathlon and 82 Kinemax implants. All patients were diagnosed with osteoarthritis, and drawn from a single centre. Output was reported as maximal wattage (W) generated in a single leg extension, and expressed as a proportion of the contralateral limb power output to act as an internal control. The results are shown in the table below. Two-way repeated measures ANOVA demonstrated a significant effect of TKA on the quadriceps power output, F = 249.09, p = <0.001 and also a significant interaction of the implant group on the output F = 11.33, p = 0.001. Independent samples t-tests of between group differences at the four assessment periods highlighted greater improvement in the single radius TKA group at all post-operative assessments (p <0.03), see table. The theoretical enhanced quadriceps efficiency conferred by single radius design was found in this study. Power output was significantly greater at all post-operative assessments in the single radius compared to the multi radius group. This difference was particularly relevant at early 6 week and 1 year assessment. Lower limb power output is known to link positively to functional ability. The results support the hypothesis that TKAs with a single radius design have enhanced recovery and better function


Bone & Joint 360
Vol. 9, Issue 2 | Pages 46 - 48
1 Apr 2020
Evans JT Whitehouse MR


Bone & Joint Research
Vol. 8, Issue 3 | Pages 136 - 145
1 Mar 2019
Cerquiglini A Henckel J Hothi H Allen P Lewis J Eskelinen A Skinner J Hirschmann MT Hart AJ

Objectives

The Attune total knee arthroplasty (TKA) has been used in over 600 000 patients worldwide. Registry data show good clinical outcome; however, concerns over the cement-tibial interface have been reported. We used retrieval analysis to give further insight into this controversial topic.

Methods

We examined 12 titanium (Ti) PFC Sigma implants, eight cobalt-chromium (CoCr) PFC Sigma implants, eight cobalt-chromium PFC Sigma rotating platform (RP) implants, and 11 Attune implants. We used a peer-reviewed digital imaging method to quantify the amount of cement attached to the backside of each tibial tray. We then measured: 1) the size of tibial tray thickness, tray projections, peripheral lips, and undercuts; and 2) surface roughness (Ra) on the backside and keel of the trays. Statistical analyses were performed to investigate differences between the two designs.


Bone & Joint Research
Vol. 7, Issue 1 | Pages 12 - 19
1 Jan 2018
Janz V Schoon J Morgenstern C Preininger B Reinke S Duda G Breitbach A Perka CF Geissler S

Objectives

The objective of this study was to develop a test for the rapid (within 25 minutes) intraoperative detection of bacteria from synovial fluid to diagnose periprosthetic joint infection (PJI).

Methods

The 16s rDNA test combines a polymerase chain reaction (PCR) for amplification of 16s rDNA with a lateral flow immunoassay in one fully automated system. The synovial fluid of 77 patients undergoing joint aspiration or primary or revision total hip or knee surgery was prospectively collected. The cohort was divided into a proof-of-principle cohort (n = 17) and a validation cohort (n = 60). Using the proof-of-principle cohort, an optimal cut-off for the discrimination between PJI and non-PJI samples was determined. PJI was defined as detection of the same bacterial species in a minimum of two microbiological samples, positive histology, and presence of a sinus tract or intra-articular pus.


Objectives

Preservation of both anterior and posterior cruciate ligaments in total knee arthroplasty (TKA) can lead to near-normal post-operative joint mechanics and improved knee function. We hypothesised that a patient-specific bicruciate-retaining prosthesis preserves near-normal kinematics better than standard off-the-shelf posterior cruciate-retaining and bicruciate-retaining prostheses in TKA.

Methods

We developed the validated models to evaluate the post-operative kinematics in patient-specific bicruciate-retaining, standard off-the-shelf bicruciate-retaining and posterior cruciate-retaining TKA under gait and deep knee bend loading conditions using numerical simulation.