Advertisement for orthosearch.org.uk
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

Research

SINGLE RADIUS OF CURVATURE IMPLANT DESIGN ENHANCES POWER OUTPUT FOLLOWING TOTAL KNEE ARTHROPLASTY

British Orthopaedic Research Society (BORS)



Abstract

End-stage osteoarthritis is characterised by pain and reduced physical function, for which total knee arthroplasty (TKA) is recognised to be a highly effective treatment. Most implants are multi radius in design, though modern kinematic theory suggests a single flexion/extension axis is located in the femur. A recently launched TKA implant (Triathlon, Stryker US), is based on this theory, adopting a single radius of curvature femoral component. It is hypothesised that this design allows better function, and specifically, that it results in enhanced efficiency of the quadriceps group through a longer patello-femoral moment arm.

Change in power output was compared between single and multi radius implants as part of a larger ongoing randomised controlled trial to benchmark the new implant. Power output was assessed using a Leg Extensor Power Rig, well validated for use with this population, pre-operatively and at 6, 26 and 52 weeks post-operatively in 101 Triathlon and 82 Kinemax implants. All patients were diagnosed with osteoarthritis, and drawn from a single centre. Output was reported as maximal wattage (W) generated in a single leg extension, and expressed as a proportion of the contralateral limb power output to act as an internal control.

The results are shown in the table below. Two-way repeated measures ANOVA demonstrated a significant effect of TKA on the quadriceps power output, F = 249.09, p = <0.001 and also a significant interaction of the implant group on the output F = 11.33, p = 0.001. Independent samples t-tests of between group differences at the four assessment periods highlighted greater improvement in the single radius TKA group at all post-operative assessments (p <0.03), see table.

The theoretical enhanced quadriceps efficiency conferred by single radius design was found in this study. Power output was significantly greater at all post-operative assessments in the single radius compared to the multi radius group. This difference was particularly relevant at early 6 week and 1 year assessment. Lower limb power output is known to link positively to functional ability. The results support the hypothesis that TKAs with a single radius design have enhanced recovery and better function.