Advertisement for orthosearch.org.uk
Results 1 - 20 of 30
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 23 - 23
2 Jan 2024
Ciatti C Quattrini F Asti C Maniscalco P
Full Access

Previous scientific studies have highlighted how coupling is an important element affecting total hip arthroplasty's survival. This study aims to evaluate whether metal-on-metal (MOM) coupling could be a statistically significant risk factor. The data from the regional joint registry (Registro dell'Impiantologia Protesica Ortopedica, RIPO) was used for analysis. The data collection accuracy of this registry was 97.2% in 2017. We retrospective evaluate all MOM total hip arthroplasties (THAs) implanted in our department between January 01st 2000 and December 31st 2011. We used a control group composed by all other prosthesis implanted in our Department in the same time lapse. We registered 660 MOM THAs. Mean age of patients was 66.9 years. 603 patients have a >36mm head, while 78 a <36 mm one. Neck modularity was present in half of patients. 676 implants were cementless. We registered 69 revisions, especially due to aseptic mobilization (16 THAs), implant breakage (9 THAs) and periprosthetic fracture (6 THAs). The MOM THAs overall Kaplan-Meier survival rate was 87.2 at 15 years, and the difference between MOM THAs and other implants two curves is statistically significant (p<0.05). Male sex is a significant risk factors. Further evaluations are in progress to establish the presence of any additional risk factors. We think weight and/or BMI may be included in this category. Our study confirms the data currently present in the literature regarding a lower survival of metal-on-metal hip prostheses. The male sex is a statistically significant risk factor (p<0.05), while age, head size and modularity of the prosthetic neck are not statistically significant (p>0.05). Any new finds will be presented at the congress venue


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 144 - 144
1 Nov 2021
García-Rey E Saldaña-Quero L Sedel L
Full Access

Introduction and Objective. Despite pure alumina have shown excellent long-term results in patients undergoing total hip arthroplasty (THA), alumina matrix composites (AMCs) composed of alumina and zirconium oxide are more commonly used. There are no comparative studies between these two different ceramics. We performed a retrospective case-control study to compare results and associated complications between AMC from two manufacturers and those with pure alumina from another manufacturer. Materials and Methods. 480 uncemented THAs with ceramic on ceramic (CoC) bearing surfaces (288 men and 192 women; mean age of 54.1 ± 12.4 years), were implanted from 2010 to 2015. Group 1: 281 THAs with pure alumina; Group 2A: 142 with AMC bearing in a trabecular titanium cup. Group 2B: 57 hips with AMC bearing with a porous-coated cup. Results. The mean follow-up was 7.3 years. There was one late infection in group 1, eight dislocations, three in group 1 (1.1%), three in group 2A (2.1%), all with a 36 mm femoral head, and two in group 2C (3.5%). Liner malseating was found in one hip in group 1, and in five hips in group 2C, of these, there were four liner fractures (7.0%). Four cups were revised for iliopsoas impingement (three in group 1 and one in group 2B). Two cups were revised for aseptic loosening, one in group 1 and one in group 2A, and four revised femoral stems in group 2A, three for subsidence and another for postoperative periprosthetic B. 2. fracture. The mean preoperative Harris Hip Score was 48.6 ± 3.3 in the whole series and 93.9 ± 7.2 at the end of follow-up. The survival rate of revision for any cause was 98.2% (95% Confidence Interval: 96.6–99.8) at ten years for group 1, 95.8% (95% CI: 92.1–99.5) for group 2A, and 91.1% (95% CI: 83.7–98.5) for group 2B (log-rank 0.030). Conclusions. Outcome of uncemented CoC THA in young patients was satisfactory at mid-term in all three groups. However, liner fractures were frequent in group 2B. All dislocated hips in group 2A had a 36 mm femoral head diameter, and revision due to any cause was less frequent in group 1. Pure alumina CoC THA can be used as a benchmark for comparison with newer CoC THAs


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 102 - 102
11 Apr 2023
Mosseri J Lex J Abbas A Toor J Ravi B Whyne C Khalil E
Full Access

Total knee and hip arthroplasty (TKA and THA) are the most commonly performed surgical procedures, the costs of which constitute a significant healthcare burden. Improving access to care for THA/TKA requires better efficiency. It is hypothesized that this may be possible through a two-stage approach that utilizes prediction of surgical time to enable optimization of operating room (OR) schedules. Data from 499,432 elective unilateral arthroplasty procedures, including 302,490 TKAs, and 196,942 THAs, performed from 2014-2019 was extracted from the American College of Surgeons (ACS) National Surgical and Quality Improvement (NSQIP) database. A deep multilayer perceptron model was trained to predict duration of surgery (DOS) based on pre-operative clinical and biochemical patient factors. A two-stage approach, utilizing predicted DOS from a held out “test” dataset, was utilized to inform the daily OR schedule. The objective function of the optimization was the total OR utilization, with a penalty for overtime. The scheduling problem and constraints were simulated based on a high-volume elective arthroplasty centre in Canada. This approach was compared to current patient scheduling based on mean procedure DOS. Approaches were compared by performing 1000 simulated OR schedules. The predict then optimize approach achieved an 18% increase in OR utilization over the mean regressor. The two-stage approach reduced overtime by 25-minutes per OR day, however it created a 7-minute increase in underutilization. Better objective value was seen in 85.1% of the simulations. With deep learning prediction and mathematical optimization of patient scheduling it is possible to improve overall OR utilization compared to typical scheduling practices. Maximizing utilization of existing healthcare resources can, in limited resource environments, improve patient's access to arthritis care by increasing patient throughput, reducing surgical wait times and in the immediate future, help clear the backlog associated with the COVID-19 pandemic


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 78 - 78
2 Jan 2024
Ponniah H Edwards T Lex J Davidson R Al-Zubaidy M Afzal I Field R Liddle A Cobb J Logishetty K
Full Access

Anterior approach total hip arthroplasty (AA-THA) has a steep learning curve, with higher complication rates in initial cases. Proper surgical case selection during the learning curve can reduce early risk. This study aims to identify patient and radiographic factors associated with AA-THA difficulty using Machine Learning (ML). Consecutive primary AA-THA patients from two centres, operated by two expert surgeons, were enrolled (excluding patients with prior hip surgery and first 100 cases per surgeon). K- means prototype clustering – an unsupervised ML algorithm – was used with two variables - operative duration and surgical complications within 6 weeks - to cluster operations into difficult or standard groups. Radiographic measurements (neck shaft angle, offset, LCEA, inter-teardrop distance, Tonnis grade) were measured by two independent observers. These factors, alongside patient factors (BMI, age, sex, laterality) were employed in a multivariate logistic regression analysis and used for k-means clustering. Significant continuous variables were investigated for predictive accuracy using Receiver Operator Characteristics (ROC). Out of 328 THAs analyzed, 130 (40%) were classified as difficult and 198 (60%) as standard. Difficult group had a mean operative time of 106mins (range 99–116) with 2 complications, while standard group had a mean operative time of 77mins (range 69–86) with 0 complications. Decreasing inter-teardrop distance (odds ratio [OR] 0.97, 95% confidence interval [CI] 0.95–0.99, p = 0.03) and right-sided operations (OR 1.73, 95% CI 1.10–2.72, p = 0.02) were associated with operative difficulty. However, ROC analysis showed poor predictive accuracy for these factors alone, with area under the curve of 0.56. Inter-observer reliability was reported as excellent (ICC >0.7). Right-sided hips (for right-hand dominant surgeons) and decreasing inter-teardrop distance were associated with case difficulty in AA-THA. These data could guide case selection during the learning phase. A larger dataset with more complications may reveal further factors


Results in patients undergoing total hip arthroplasty (THA) for femoral head osteonecrosis (ON) when compared with primary osteoarthritis (OA) are controversial. Different factors like age, THA type or surgical technique may affect outcome. We hypothesized that patients with ON had an increased revision rate compared with OA. We analysed clinical outcome, estimated the survival rate for revision surgery, and their possible risk factors, in two groups of patients. In this retrospective cohort analysis of our prospective database, we assessed 2464 primary THAs implanted between 1989 and 2017. Patients with OA were included in group 1, 2090 hips; and patients with ON in group 2, 374 hips. In group 2 there were more men (p<0.001), patients younger than 60 years old (p<0.001) and with greater physical activity (p<0.001). Patients with lumbar OA (p<0.001) and a radiological acetabular shape type B according to Dorr (p<0.001) were more frequent in group 1. Clinical outcome was assessed according to the Harris Hip Score and radiological analysis included postoperative acetabular and femoral component position and hip reconstruction. Kaplan-Meier survivorship analysis was used to estimate the cumulative probability of not having revision surgery for different reasons. Univariate and multivariate Cox regression models were used to assess risk factors for revision surgery. Clinical improvement was better in the ON at all intervals. There were 90 hips revised, 68 due to loosening or wear, 52 (2.5%) in group 1, and 16 (4.3%) in group 2. Overall, the survival rate for revision surgery for any cause at 22 years was 88.0 % (95% CI, 82-94) in group 1 and 84.1% (95% CI, 69 – 99) in group 2 (p=0.019). Multivariate regression analysis showed that hips with conventional polyethylene (PE), compared with highly-cross linked PEs or ceramic-on-ceramic bearings, (p=0.01, Hazard Ratio (HR): 2.12, 95% CI 1.15-3.92), and cups outside the Lewinnek´s safe zone had a higher risk for revision surgery (p<0.001, HR: 2.57, 95% CI 1.69-3.91). Modern highly-cross linked PEs and ceramic-on-ceramic bearings use, and a proper surgical technique improved revision rate in patients undergoing THA due to ON compared with OA


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 143 - 143
1 Nov 2021
McCarthy C Mahon J Sheridan G Welch-Phillips A O'Byrne J Kenny P
Full Access

Introduction and Objective. Ceramic on Ceramic bearings in Total Hip Arthroplasty (THA) afford a low friction coefficient, low wear rates and extreme hardness. Significant complications include hip squeak, ceramic fracture and poor polyethylene performance in revision procedures due to imbedding of abrasive microscopic ceramic fragments. We report on the results of this bearing at a minimum of 10 years. Materials and Methods. A single-centre retrospective review of 449 THAs was performed. Primary outcome measures included aseptic revision and all-cause revision rates at a minimum of 10 years post operatively. Evaluation of functionality was performed with WOMAC and SF-36 scores which were performed pre-operatively and at intervals of 6 months, one year, 2 years, 5 years and 10 years post operatively. Results. There was a 6.2% (n=28) all-cause and 5.3% (n=24) aseptic revision rate for ceramic on ceramic total hip arthroplasty at minimum of 10 years with a mean time to revision 4.8 years (range 2 months − 11.6 years). Notably, there were 2 revisions for ceramic head fracture, one for ceramic liner fracture, 3 for aseptic loosening and 3 revisions for squeaking. Pain of unknown origin was the most common reason for revision. There was an improvement in postoperative WOMAC scores from a mean of 59.8 (range 15–95) pre-operatively to a mean of 15.6 (range 0–78) at 10 years. Conclusions. This study showed good functional outcomes but high revision rates for CoC THA at a minimum of 10 years. The role for CoC bearings in THA has been called into question in recent years and may continue to decline in popularity, even in younger patients. Further large scale studies are important to assess the long-term outcomes of this bearing surface


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 101 - 101
1 Nov 2018
Veltman E Lenguerrand E Moojen D Whitehouse M Nelissen R Blom A Poolman R
Full Access

Administration of perioperative antibiotic prophylaxis (AP) reduces the risk of prosthetic joint infection (PJI) following primary total hip (THA) and knee (TKA) arthroplasty. The optimal type of antibiotic used, and duration of prophylaxis are subject to debate. We compared the risk of revision surgery for PJI in the first year following THA and TKA by AP regimen. A national survey collecting information on hospital-level AP regimen policy was conducted across the Netherlands and linked to data from the LROI arthroplasty registry for 2011–2015. PJI status was defined using the surgical indication reported at revision by surgeons in the registry form. Restricted cubic splines Poisson model adjusted for hospital clustering were used to conduct the comparisons on 130,712 THAs and 111,467 TKAs performed across 99 institutions. These included 399 THAs and 303 TKAs revised for an indication of PJI. Multiple shot of Cefazolin (MCZ), of cefuroxime (MCX) and single shot of Cefazolin (SCZ) were respectively administrated to 87%, 4% and 9% of patients. For THA, the rates of revision for PJI were respectively 31/10,000 person-years 95%CI[28, 35], 39[25, 59] and 23[15, 34] in the groups which received MCZ, MCX and SCZ; respectively, the rates for TKA were 27[24, 31], 40[24, 62] and 24[16, 36]. No evidence of difference between AP regimens was found in the unadjusted and adjusted model (age, gender, BMI and ASA grade). Further work is advocated to confirm whether there is an association between AP regimen collected at patient-level and the risk of subsequent revision for PJI


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 6 - 6
1 Aug 2013
Boyd A Soon V Sapare S McAllister J Deakin A Sarungi M
Full Access

Patient reported outcome measures (PROMs) are important for assessing the results of lower limb arthroplasty. Unrealistic or uneducated expectations may have a significant negative impact on PROMs even when surgery is technically successful. This study's aim was to quantify pre-operative expectations of Scottish patients undergoing total hip and knee replacement (THR/TKR). 100 THR and 100 TKR patients completed validated questionnaires (from the Hospital for Special Surgery) prior to their operation after receiving standard pre-operative information (booklet, DVD, consultations). Each patient rated expectations from very important to not having the expectation. A total score was calculated using a numerical scale for the grading of each expectation. Univariate regression analysis was used to investigate the relationship between demographics and expectation score. The THR cohort had mean age 66.2 (SD 10.5), 53% female, mean BMI 29.0 (SD 5.1) and mean Oxford score 44 (SD 7). The TKR cohort had mean age 67.6 (SD 8.5), 59% female, mean BMI 32.8 (SD 5.8) and mean Oxford score 44 (SD 8). 100% THR and 96% TKR patients had 10 or more expectations of their operation. All expected pain relief. Other improvements expected were: walking for 100% THA and 99% TKA patients; daily activities for 100% THAs and 96% TKAs; recreational activities for 96% THAs and 93% TKAs; sexual activity for 66% THAs and 59% TKAs; psychological well-being for 98% THAs and 91% TKAs. Regression analysis showed increasing age lowered expectations in both THR (p=0.025) and TKR (p=0.031) patients but that gender, BMI and Oxford score were not significantly related to expectations. This study highlights that patients expect far more than pain relief and improved post-operative mobility from their operation. It is important to discuss and manage these expectations with patients prior to surgery. By doing so, patient satisfaction and PROMs should further improve


Bone & Joint 360
Vol. 13, Issue 6 | Pages 48 - 49
1 Dec 2024
Evans JT Kulkarni Y Whitehouse MR


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 15 - 15
1 Aug 2013
Diffin C Chambers M Campton L Roberts J
Full Access

Posterior soft tissue repair is often performed in Total Hip Arthroplasty (THA). Many reports have shown the advantage of posterior soft tissue repair in reducing their prosthetic hip dislocation rates. We describe an easy and inexpensive way of passing sutures through small drill holes in the Greater Trocanter to re-attach muscle, tendon and capsule in a posterior soft tissue repair. By using a reversed monofilament suture on a straight needle held in artery forceps and passing this in a retrograde direction through a drill hole, a suture capturing device is produced. By capturing the long ends of sutures tied in the short external rotators and the posterior capsule of the hip through 2 drill holes in the Greater Trochanter, a posterior soft tissue repair can be performed. We have used this technique successfully in over 100 consecutive THAs. We conclude that the use of a monofilament suture used in the manner describe is an excellent and inexpensive way to aid in a posterior soft tissue repair in THAs. This is done without the cost of an additional dedicated suture passing device. The suture could also be used in the skin closure if desired


Bone & Joint 360
Vol. 11, Issue 4 | Pages 44 - 46
1 Aug 2022
Evans JT Walton TJ Whitehouse MR


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 7 - 7
1 Nov 2018
Wong L Moriarty P Harty J
Full Access

Revision total hip arthroplasty (THA) presents with increasing challenges, potentially compromising the integrity of a revision. The objective of this study was to assess radiologic outcomes of patients who underwent revision THA with a modular tapered stem (Reclaim, DePuy Synthes). This study retrospectively examined all revision Reclaim THAs between 2012 and 2016. Radiologic assessment compared x-rays at two time points: immediately after surgery and the most recent x-ray available. Leg length discrepancy, subsidence and line-to-line fit was assessed. Significant subsidence was considered ≥10mm. Adequate line-to-line fit was considered ≥30mm of bicortical contact. Descriptive statistics included clinical factors (i.e. age, Paprosky classification). P values <0.05 were considered significant. A total of 81 femoral revisions were completed. There were 42 females and 38 males with a mean age of 71 years (range, 46–89). Of these, 6 were revised (dislocation, fracture or infection), and 7 were lost to follow up. Average follow up time was 18 months (range, 1–46 months). Femoral revisions were classified as Paprosky 3a or 3b. Mean stem subsidence was 4.15mm (range, 0–25.6mm). Subsidence of the femoral stem was <10mm in 88% of patients. A total of 62% of patients had both subsidence <10mm and ≥30mm of bicortical contact. In patients with <10mm subsidence, 70% had ≥30mm of bicortical contact. There was a positive trend between cortical contact and stem stability (OR 2.3). The Reclaim modular femoral system has demonstrated radiographic stability. Inadequate initial fit is a potential determinant of subsidence


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 11 - 11
1 Nov 2018
Maniscalco P Ciatti C Ghidoni L Ghidoni G Strigini G Pogliacomi F Ceccarelli F
Full Access

Neck modularity has been proposed to improve THA accuracy, thanks to the close restoration of anatomy, however it has been associated with issues like early breakages or corrosion. Our Hospital has been using neck modularity since the 90s, so we analyzed retrospectively implants performed between January 2000 and December 2014. The minimum follow up was 1Y. The cohort was composed of 1,033 THAs or 951 patients (82 bilateral), of which 643 females and 390 males. Average patient age was 67.7Y. THA indications were primary Osteoarthritis (80.9%), Fracture (9.0%), Congenital Dysplasia or Congenital Luxation (4.2%), Osteonecrosis (3.2%), other causes (2,7%). The stems used were all cementless, 381 anatomically shaped (36.9%), 635 straight (61.5%), 17 short MIS (1.6%). All necks used were made of Titanium alloy. 419 implants (40.5%) were manufactured by Wright Medical, while 614 (59.5%) were produced by Adler Ortho. A total of 37 revisions has been reported, mainly due to periprosthetic fractures (32.4%), luxation (24.3%), implant mobilization (18.9%) and implant breakage (16.2%). We have recorded 3 modular neck breakages. 4 patients required re-revisions, because of luxations (3) and neck breakage (1). The overall survival rate was 96.4%. We did not observe any component corrosion, probably thanks to the exclusive use of Titanium necks. We had a neck breakages rate of 0.29% and a luxation rate of 0.87%, lower than normally reported in the literature. In conclusion, our experience suggests as neck modularity could be a safe and effective way to reconstruct the proximal femur in THA patients


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 14 - 14
1 Apr 2018
Teoh KH Whitham R Golding D Lee PYF Evans A
Full Access

Background. The R3 cementless acetabular system (Smith & Nephew, Memphis, Tennessee, United States) is a modular titanium shell with an asymmetric porous titanium powder coating. It supports cross-linked polyethylene, metal and ceramic liners with several options for the femoral head component. The R3 cup was first marketed in Australia and Europe in 2007. Two recent papers have shown high failure rates of the MoM R3 system with up to 24% (Dramis et al 2014, Hothi et al 2015). There are currently no medium term clinical papers on the R3 acetabular cup. Objectives. The aim of the study is to review our results of the R3 acetabular cup with a minimum of 5 year follow up. Study Design & Methods. Patients who were implanted with the R3 acetabular cup were identified from our centre”s arthroplasty database. Our centre started implanting the R3 acetabular cup in August 2009. For this study, we only included patients with a minimum of 5 year follow up (until June 2011). Over this time period, 293 consecutive THAs were performed in 286 patients, of which 7 were bilateral staged total hip arthroplasties. The primary outcome was revision. The secondary outcomes were the Oxford hip scores and radiographic evaluation. Results. The mean age of the patients was 69.4 years (range 20–100 years). There were 117 males and 169 females in our series. The majority of the total hip arthroplasties in our series were cementless (n=283, 97%) and the rest were hybrid (n=10, 3%). The articulation bearings were as follows: ceramic on ceramic (n=167; 57%), Ceramic on Poly XLPE (n=97; 33%), Oxinium-Poly XLPE (n=19; 6.5%), stainless steel- Poly XLXE (n=10; 3.5%). The mean pre-operative Oxford Hip Score was 23 (range 10–34) and the mean Oxford Hip Score was 40 (range 33–48) at the final follow-up. Radiological evaluation showed an excellent ARA-score in all patients at five years. None of the R3 cups showed osteolysis at final follow up. There were 3 revisions in our series, of which two R3 cup were revised. The risk of revision was 0.28% at 5 years. Using Weibull analysis, it gives a 10-year estimate of 98.8% survival for the R3 cup (95%CI 95.0 to 99.6). Conclusions. Our experience at a district general hospital using the R3 acetabular system with conventional bearings showed high survivorship and is consistent with the allocated Orthopaedic Data Evaluation Panel (ODEP) rating of 5A* as rated in 2015 in the United Kingdom


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 50 - 50
1 Apr 2017
Wasko M Bobecka K Wesolowska Pokrzywnicka I Kowalczewski G Kowalczewski J
Full Access

Background. Hitherto, no study has compared blood loss (BL) after different thromoprophylactic regimes (TR). The objective of this study was to quantify and compare BL in total hip arthroplasty (THA) under three different TRs. Methods. Between September 2013 and July 2014, sixty primary, unilateral, same-implant THAs entered a randomised, double-blind clinical trial. The patients were randomised to receive manufacturers' recommended doses of enoxaparin, dabigatran or rivaroxaban. Complete blood counts were obtained preoperatively and on the third day postoperatively. BL was calculated according to the Nadler formula. We also evaluated the occurence of wound healing disturbances (WHDs). All data were analysed using R statistical software. Results. The mean BL and standard deviations were 844 ± 222 ml for enoxaparin, 854 ± 205 ml for dabigatran and 806 ± 227 ml for rivaroxaban. The BL did not significantly differ between groups (Kruskall-Wallis, p=0.92). More WHDs occured in the rivaroxaban group (5/20), compared to enoxaparin (2/20) and dabigatran (3/20). Conclusions. None of the chemical TR is superior to others in terms of reducing the BL. There seems to be more WHDs with the use of oral agents - this finding needs further studies. Level of evidence. 1b (Centre for Evidence Based Medicine, Oxford). Approval. This study was approved by The Medical Centre of Postgraduate Education Ethical Committee. Disclosure. The authors disclose no competing interests


Bone & Joint 360
Vol. 10, Issue 4 | Pages 49 - 51
1 Aug 2021
Evans JT Welch M Whitehouse MR


Bone & Joint 360
Vol. 10, Issue 2 | Pages 57 - 59
1 Apr 2021
Evans JT Whitehouse MR Evans JP


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_3 | Pages 14 - 14
1 Apr 2015
Halai M Augustine A Holloway N MacDonald D Mohammed A Meek R Patil S
Full Access

Two major challenges in arthroplasty are obesity and antibiotic resistance. This study was performed to characterise the organisms responsible for deep infection following total hip arthroplasty and to determine if obesity affected the microbiology profile. A retrospective analysis of the national surgical site infection register was made to obtain data regarding deep infection following 10948 primary total hip arthroplasty (THA) from 1998–2013, with a minimum of 2 year follow-up. Of all the primary THAs performed, there were 108 deep infections (56 patients had a BMI >30 (obese) and 52 patients <30). There were no significant differences between cardio-respiratory disease, smoking and alcohol status, and diabetes between the 2 groups. Over the last 15 years, staphylococcus aureus continues to be the most frequently isolated organism. Infection with multiple organisms was found exclusively in obese patients. Furthermore, in obese patients, there was a linear increase with methicillin resistant staphylococcus aureus (MRSA) infections and streptococcus viridans. On this basis, we recommend careful selection of antibiotic therapy in obese patients, rather than empirical therapy, which can be especially important if there is no growth in an infected THA. In addition, a preoperative discussion regarding dental prophylaxis against streptococcus viridans may be warranted


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 1 - 1
1 Aug 2013
Halai M Jayaram P Drury C Gregori A Murray D Oroko P Periasamy K
Full Access

Aluminia ceramic on ceramic (COC) bearing surfaces have been used for 35 years in total hip arthroplasty (THA). Studies report 85% survival at a minimum follow-up of 18.5 years. Nonetheless, an audible noise is a finding associated with COC bearings with incidence rates of 2–10%. This study aims to determine the prevalence of noise and evaluate its effect on patients. All patients who had a COC THA from August 2003 to December 2010 were contacted and asked to complete a standardised questionnaire. This asked about the presence and characteristics of a noise and if associated with activities, pain and whether this phenomenon should be mentioned preoperatively. Four consultant surgeons performed 282 consecutive primary COC THAs in 258 patients. (Male=122, Female=136 mean age 68.5; age range 28–88). In all cases, the same brand of ceramic acetabular component and stems were implanted. 11.0% had a noise, of which 5.5% had a squeak. Pain was experienced in 38.7% of patients in hips that made a noise. There was no trauma and one dislocation in this group. In this study, 85% of noises occur during weight-bearing although no patients have reduced daily activities as a result of the noises. Of all the patients, 55.0% stated they would have preferred to have known about a noisy hip possibility before consenting but none would have refused consent. Squeaking has not been a problem here despite the prevalence being higher than most in the literature. The authors recommend that squeaking should be discussed preoperatively. A checklist for Orthopaedic Trainees is being drafted to enable trainees to counsel patients appropriately, allowing patients a better opportunity to give informed consent


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 56 - 56
1 Aug 2013
Vun S Gillespie J Agarwal M
Full Access

Low molecular weight heparin (LMWH) is frequently used as thromboprophylaxis after major orthopaedic surgery. Varying levels of non-adherence (5% to 45%) with outpatient LMWH has been reported. Oral direct thrombin inhibitors have been recommended by industry due to ease of administration. We aim to audit the compliance rate with outpatient LMWH treatment following primary total hip arthroplasties (THA) in our district general hospital (DGH). Using the ORMIS computer system, we identified all primary THA performed in Monklands Hospital between July 2011 and August 2012. Patients’ case notes were analysed retrospectively, looking at operating surgeon's postoperative thromboprophylaxis instructions. We then conducted a telephone interview on patients discharged with outpatient LMWH to assess compliance. There were 58 primary THAs performed during the audit period. 33 patients were discharged on outpatient LMWH, whilst 15 patients and 3 patients were discharged on aspirin and warfarin respectively. Seven patients were excluded as their discharge prescriptions were missing. We successfully contacted 20 of the 33 patients discharged with outpatient LMWH. All respondents showed 100% compliance to the full course of treatment. 50% of patients self-administered; 30% were administered by district nurses and 20% by family members. 35% of patients preferred an oral tablet alternative, for its perceived ease of administration. Bruising and skin irritation were the reported problems in some patients, but these did not affect compliance. Contrary to the previous published non-adherence rates, the compliance rate with outpatient LMWH after THA was high in our DGH. The patient counseling, and family/district nurse involvement in may have contributed to this. However, our numbers of patients are low but data collection continues