Advertisement for orthosearch.org.uk
Results 1 - 20 of 34
Results per page:
Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 5 - 5
1 Nov 2018
Deering EM Hu S Abdulkarim A
Full Access

Tourniquets have been used for many years during total knee arthroplasty (TKA). With a growing demand for TKA in recent years, tourniquet use has been surrounded by ongoing controversy due to many conflicting advantages and disadvantages of tourniquet use. Quantifying the case for or against tourniquet use in TKA, in terms of patient focused outcomes, is a priority. This meta-analysis analysed, the never before assessed, impact of tourniquet use during TKA on post-operative pain. We completed a systematic review and meta-analysis using PRISMA reporting guidelines to assess the impact of tourniquet use on patients post-TKA. Post-operative pain was the primary outcome. Secondary outcomes were post-operative range of motion (ROM) and length of stay (LOS). The initial search yielded 230 studies, of which 14 met the inclusion criteria. A post-operative increase in pain and reduction in ROM when using a tourniquet appeared significantly more likely when compared to no tourniquet use during TKA, yet with no overall difference in post-operative LOS. Subgroup meta-analysis demonstrated a trend that favoured the half-course tourniquet for reduced post-operative pain in patients when compared to full tourniquet use during TKA. This systematic review and meta-analysis concluded that the after-effects of tourniquet use in TKA patients and its impact on post-operative pain and ROM are indeed significant. We recommend further randomized controlled trials (RCTs) focusing on TKA patient outcomes of post-operative pain and ROM. Conflict of interest: The authors certify that they have NO affiliations with or involvement in any organization or entity with any financial interest (such as honoraria; educational grants; participation in speakers' bureaus; membership, employment, consultancies, stock ownership, or other equity interest; and expert testimony or patent-licensing arrangements), or non-financial interest (such as personal or professional relationships, affiliations, knowledge or beliefs) in the subject matter or materials discussed in this manuscript


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 27 - 27
14 Nov 2024
Bulut H Giray Batibay S Kanay E Özkan K
Full Access

Introduction. Despite the implementation of numerous preventive measures in recent years, the persistent challenge of periprosthetic infections remains. Among the various strategies, metallic modification of implants, particularly with silver, has emerged as a promising avenue. Silver's antimicrobial properties, coupled with its low human toxicity, render it an appealing option. However, ongoing debate surrounds its comparative efficacy in infection prevention when contrasted with titanium-coated prostheses. Methods. The PubMed database was systematically searched up to March 2024. Studies in English that met predetermined inclusion/exclusion criteria and utilized “Megaprosthesis AND infection” and “ silver-coated AND infection “ as key terms were included. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses(PRISMA) statement guided the article selection process. Results. From a pool of 1892 potential papers after literature screening, 11 studies with a total of 1419 patients were meticulously selected for analysis. Among these patients, 638 were treated with silver-coated implants, while 781 received titanium-coated implants, resulting in 166 recorded cases of infection. Remarkably, the infection rate stood at 9.2% for the silver-coated group, contrasting with 13.4% for the titanium-coated group. The subsequent analysis unveiled a notable discrepancy in proportions (P difference = -0.0473, 95%CI: -0.088 to -0.006), signaling a statistically significant decrease in infections within the silver-coated cohort. Furthermore, the I2 statistic, denoting heterogeneity in effect sizes, stood at 21.8% (95%CI: 0.0-66.9), indicating a modest degree of variability among the studies. Conclusion. In conclusion, our systematic review and meta-analysis shed light on the potential of silver-coated implants in mitigating periprosthetic infections. Despite the persistent challenge posed by such infections, our findings suggest a statistically significant decrease in infection rates among patients treated with silver-coated implants compared to those with titanium-coated ones


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 49 - 49
17 Apr 2023
Cooper G Kennedy M Jamal B Shields D
Full Access

Our objective was to conduct a systematic review and meta-analysis, comparing differences in clinical outcomes between either autologous or synthetic bone grafts in the operative management of tibial plateau fractures: a traumatic pattern of injury, associated with poor long-term functional prognosis. A structured search of MEDLINE, EMBASE, The Bone & Joint and CENTRAL databases from inception until 07/28/2021 was performed. Randomised, controlled, clinical trials that compared autologous and synthetic bone grafts in tibial plateau fractures were included. Preclinical studies, clinical studies in paediatric patients, pathological fractures, fracture non-union or chondral defects were excluded. Outcome data was assessed using the Risk of Bias 2 (ROB2) framework and synthesised in random-effect meta-analysis. Preferred Reported Items for Systematic Review and Meta-Analysis guidance was followed throughout. Six comparable studies involving 352 patients were identified from 3,078 records. Following ROB2 assessment, five studies (337 patients) were eligible for meta-analysis. Within these studies, more complex tibia plateau fracture patterns (Schatzker IV-VI) were predominant. Primary outcomes showed non-significant reductions in articular depression at immediate postoperative (mean difference −0.45mm, p=0.25, 95% confidence interval (95%CI): −1.21-0.31mm, I. 2. =0%) and long-term (>6 months, standard mean difference −0.56, p=0.09, 95%CI: −1.20-0.08, I. 2. =73%) follow-up in synthetic bone grafts. Secondary outcomes included mechanical alignment, limb functionality, defect site pain, occurrence of surgical site infections, secondary surgery, perioperative blood loss, and duration of surgery. Blood loss was lower (90.08ml, p<0.001, 95%CI: 41.49-138.67ml, I. 2. =0%) and surgery was shorter (16.17minutes, p=0.04, 95%CI: 0.39-31.94minutes, I. 2. =63%) in synthetic treatment groups. All other secondary measures were statistically comparable. Our findings supersede previous literature, demonstrating that synthetic bone grafts are non-inferior to autologous bone grafts, despite their perceived disadvantages (e.g. being biologically inert). In conclusion, surgeons should consider synthetic bone grafts when optimising peri-operative patient morbidity, particularly in complex tibial plateau fractures, where this work is most applicable


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 99 - 99
4 Apr 2023
Lu V Tennyson M Fortune M Zhou A Krkovic M
Full Access

Fragility ankle fractures are traditionally managed conservatively or with open reduction internal fixation (ORIF). Tibiotalocalcaneal (TTC) fusion is an alternative option for the geriatric patient. This systematic review and meta-analysis provides a detailed analysis of the functional and clinical outcomes of hindfoot nailing for fragility ankle fractures presented so far in the literature. A systematic search was performed on MEDLINE, EMBASE, Cochrane Library, Scopus, Web of Science, identifying fourteen studies for inclusion. Studies including patients over 60 with a fragility ankle fracture, treated with TTC nail were included. Patients with a previous fracture of the ipsilateral limb, fibular nails, and pathological fractures were excluded. Subgroup analyses were performed according to (1) open vs closed fractures, (2) immediate post-operative FWB vs post-operative NWB, (3) majority of cohort are diabetics vs minority of cohort are diabetics. Meta-regression analyses were done to explore sources of heterogeneity, and publication bias was assessed using Egger's test. The pooled proportion of superficial infection, deep infection, implant failure, malunion, and all-cause mortality was 0.10 (95%CI:0.06-0.16; I2=44%), 0.08 (95%CI:0.06-0.11, I2=0%), 0.11 (95%CI:0.07-0.15, I2=0%), 0.11 (95%CI:0.06-0.18; I2=51%), and 0.27 (95%CI:0.20-0.34; I2=11%), respectively. The pooled mean post-operative OMAS score was 54.07 (95%CI:48.98-59.16; I2=85%). The best-fitting meta-regression model included age and percentage of male patients as covariates (p=0.0263), and were inversely correlated with higher OMAS scores. Subgroup analyses showed that studies with a majority of diabetics had a higher proportion of implant failure (p=0.0340) and surgical infection (p=0.0096), and a lower chance of returning to pre-injury mobility than studies with a minority of diabetics (p=0.0385). Egger's test (p=0.56) showed no significant publication bias. TTC nailing is an adequate alternative option for fragility ankle fractures. However, current evidence includes mainly case series with inconsistent outcome measures reported and post-operative rehabilitation protocols. Prospective RCTs with long follow-up times and large cohort sizes are needed to clearly guide the use of TTC nailing for ankle fractures


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 35 - 35
1 Nov 2021
Hartland A Islam R Teoh K Rashid M
Full Access

Introduction and Objective. There remains much debate regarding the optimal method for surgical management of patients with long head of biceps pathology. The aim of this study was to compare the outcomes of tenotomy versus tenodesis. Materials and Methods. This systematic review and meta-analysis was registered on PROSPERO (ref: CRD42020198658). Electronic databases searched included EMBASE, Medline, PsycINFO, and Cochrane Library. Randomized controlled trials (RCTs) comparing tenotomy versus tenodesis were included. Risk of bias within studies was assessed using the Cochrane risk of bias v2.0 tool and the Jadad score. The primary outcome included patient reported functional outcome measures pooled using standardized mean difference (SMD) and a random effects model. Secondary outcome measures included visual analogue scale (VAS), rate of cosmetic deformity (Popeye sign), range of motion, operative time, and elbow flexion strength. Results. 751 patients from 10 RCTs demonstrated (369 tenotomy vs 382 tenodesis) were included in the meta-analysis. Pooled analysis of all PROMs data demonstrated comparable outcomes between tenotomy vs tenodesis (SMD 0.17 95% CI −0.02 to 0.36, p=0.09). Sensitivity analysis comparing RCTs involving patients with and without an intact rotator cuff did not change the primary outcome. Secondary outcomes including VAS, shoulder external rotation, and elbow flexion strength did not reveal any significant difference. Tenodesis resulted in a lower rate of Popeye deformity (OR 0.27 95% CI 0.16 to 0.45, p<0.00001). Conclusions. Aside from a lower rate of cosmetic deformity, tenodesis yielded no measurable significant benefit to tenotomy for addressing pathology in the long head of biceps. This finding was irrespective of the whether the rotator cuff was intact


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 109 - 109
1 Nov 2021
Rigney B Casey C Donald CM Pomeroy E Cleary M
Full Access

Introduction and Objective. Wide awake local anaesthetic no tourniquet (WALANT) is being used for a wide variety of hand and wrist surgery. It has recently been used in distal radius fracture fixation. The purpose of this systematic review and meta-analysis was to assess the effectiveness of the WALANT technique in open reduction internal fixation. Materials and Methods. Pubmed, Embase, and Scopus databases were searched on 02/03/21 with the following search terms: radius, WALANT, local anesthetic, wide awake surgery. The primary outcome measure was conversion to general anaesthetic and mean intra-operative visual analogue scale (VAS) pain scores. Secondary measures were operative times, mean intraoperative blood loss, post-operative functional and radiological outcomes. Results. 110 articles were identified; eight studies were deemed eligible with 212 in the WALANT group and 247 in the comparative groups of regional anaesthesia and general Anaesthesia (GA). Two patients in the WALANT group required conversion to general anaesthesia due to anxiety rather than pain. Intra-operative VAS pain scores in the WALANT and regional anaesthetic group were 1.75 and 2.86 respectively (p<0.001). There was no statistically significant difference in Q-DASH scores, range of motion or radiological outcomes. There was a slight increase in mean blood loss in the WALANT group compared with those given a GA or regional anaesthetic with tourniquet (22.5ml vs 12.15ml, p<0.001). Conclusions. The WALANT technique is a viable option for anaesthetic when performing distal radius fracture fixation. It is well tolerated, giving similar post-operative outcomes to other anaesthetic methods. It is a potentially useful technique in a centre with an underresourced anaesthetic department or for patients who may not tolerate regional and general anaesthetic methods. Adequate patient counselling prior to the procedure should be performed with appropriate patient selection


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 33 - 33
1 Nov 2021
Hartland A Teoh K Rashid M
Full Access

Introduction and Objective. Tranexamic acid (TXA) is used across surgical specialties to reduce perioperative bleeding. It has been shown to be effective in trauma, spinal surgery, and lower limb arthroplasty. The aim of this study is to investigate the clinical effectiveness of TXA in all types of shoulder surgery on bleeding and non-bleeding related outcomes. Materials and Methods. This study was registered prospectively on the PROSPERO database (ref: CRD42020185482). A systematic review and meta-analysis of randomised controlled trials (RCTs) investigating intra-operative use of TXA versus placebo in any type of surgery to the shoulder girdle. Electronic databases searched included MEDLINE, EMBASE, PsychINFO, and the Cochrane Library. Risk of bias within studies was assessed using the Cochrane risk of bias v2.0 tool and Jadad score. Certainty of findings were reported using the GRADE approach. The primary outcome was total blood loss. Secondary outcomes included patient reported outcome measures, adverse events, and rate of blood transfusion. Results. Eight RCTs were included in the systematic review and data from 7 of these studies pooled in the meta-analysis. A total of 708 patients were randomized across the studies (406 received TXA, 302 received placebo). Studies included patients undergoing anatomic or reverse total shoulder arthroplasty, open Latarjet surgery, and arthroscopic rotator cuff repair. Pooled analysis demonstrated significant reduction in perioperative bleeding with TXA compared to controls; estimated total blood loss (mean difference [MD], −209.66; 95% CI −389.11 to −30.21; p=0.02), and post-operative blood loss (via drain output) (MD, −84.8ml; 95% CI, −140.04 to −29.56; p=0.003). A mean difference in Visual Analogue Scale (VAS) of 2.93 was noted in favour of TXA (95% CI 0.2 to 5.66; p=0.04). Conclusions. Whilst noting some risk of bias within the studies, TXA was effective in reducing blood loss and pain in shoulder surgery. There may be a benefit of TXA use in both open and arthroscopic shoulder procedures. Larger, low risk of bias, RCTs for specific surgical shoulder procedures are required


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 64 - 64
4 Apr 2023
Hartland A Islam R Teoh K Rashid M
Full Access

There remains much debate regarding the optimal method for surgical management of patients with long head of biceps pathology. The aim of this study was to compare the outcomes of tenotomy versus tenodesis. This systematic review and meta-analysis was registered on PROSPERO (ref: CRD42020198658). Electronic databases searched included EMBASE, Medline, PsycINFO, and Cochrane Library. Randomized controlled trials (RCTs) comparing tenotomy versus tenodesis were included. Risk of bias within studies was assessed using the Cochrane risk of bias v2.0 tool and the Jadad score. The primary outcome included patient reported functional outcome measures pooled using standardized mean difference (SMD) and a random effects model. Secondary outcome measures included pain (visual analogue scale VAS), rate of Popeye deformity, and operative time. 860 patients from 11 RCTs (426 tenotomy vs 434 tenodesis) were included in the meta-analysis. Pooled analysis of all PROMs data demonstrated comparable outcomes between tenotomy vs tenodesis (SMD 0.14, 95% CI −0.04 to 0.32; p=0.13). Sensitivity analysis comparing RCTs involving patients with and without an intact rotator cuff did not change the primary outcome. There was no significant difference for pain (VAS). Tenodesis resulted in a lower rate of Popeye deformity (OR 0.29, 95% CI 0.19 to 0.45, p < 0.00001). Tenotomy demonstrated a shorter operative time (MD 15.21, 95% CI 1.06 to 29.36, p < 0.00001). Aside from a lower rate of cosmetic deformity, tenodesis yielded no measurable significant benefit to tenotomy for addressing pathology in the long head of biceps. A large multi-centre clinical effectiveness randomised controlled trial is needed to provide clarity in this area


Arthroscopic management of femoroacetabular impingement (FAI) has become the mainstay of treatment. However, chondral lesions are frequently encountered and have become a determinant of less favourable outcomes following arthroscopic intervention. The aim of this systematic review and meta-analysis was to assess the outcomes of hip arthroscopy (HA) in patients with FAI and concomitant chondral lesions classified as per Outerbridge. A systematic search was performed using the PRISMA guidelines on four databases including MEDLINE, EMBASE, Cochrane Library and Web of Science. Studies which included HA as the primary intervention for management of FAI and classified chondral lesions according to the Outerbridge classification were included. Patients treated with open procedures, for osteonecrosis, Legg-Calve-Perthes disease, and previous ipsilateral hip fractures were excluded. From a total of 863 articles, twenty-four were included for final analysis. Demographic data, PROMs, and radiological outcomes and rates of conversion to total hip arthroplasty (THA) were collected. Risk of bias was assessed using ROBINS-I. Improved post-operative PROMs included mHHS (mean difference:-2.42; 95%CI:-2.99 to −1.85; p<0.001), NAHS (mean difference:-1.73; 95%CI: −2.23 to −1.23; p<0.001), VAS (mean difference: 2.03; 95%CI: 0.93-3.13; p<0.001). Pooled rate of revision surgery was 10% (95%CI: 7%-14%). Most of this included conversion to THA, with a 7% pooled rate (95%CI: 4%-11%). Patients had worse PROMs if they underwent HA with labral debridement (p=0.015), had Outerbridge 3 and 4 lesions (p=0.012), concomitant lesions of the femoral head and acetabulum lesions (p=0.029). Reconstructive cartilage techniques were superior to microfracture (p=0.042). Even in concomitant lesions of the femoral head and acetabulum, employing either microfracture or cartilage repair/reconstruction provided a benefit in PROMs (p=0.027). Acceptable post-operative outcomes following HA with labral repair/reconstruction and cartilage repair in patients with FAI and concomitant moderate-to-severe chondral lesions, can be achieved. Patients suffering from Outerbridge 3 and 4 lesions, concomitant acetabular rim and femoral head chondral lesions that underwent HA with labral debridement, had worse PROMs. Reconstructive cartilage techniques were superior to microfracture. Even in concomitant acetabular and femoral head chondral lesions, employing either microfracture or cartilage repair/reconstruction was deemed to provide a benefit in PROMs


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 26 - 26
1 Dec 2021
Edwards T Daly C Donovan R Whitehouse M
Full Access

Abstract. Objectives. There is debate regarding the optimal surgical technique for fixing femoral diaphyseal fractures in children aged 4 to 12 years. The aim of this study was to conduct a systematic review and meta-analysis to compare the complication rate following flexible intramedullary nailing (FIN), plate fixation and external fixation (EF) for traumatic femoral diaphyseal fractures in children aged 4 to 12. Methods. We searched MEDLINE, EMBASE and CENTRAL databases for interventional and observational studies. Two independent reviewers screened, assessed quality and extracted data from the identified studies. The primary outcome was the risk of any complication. Results. Nine randomised controlled trials (RCTs) and 19 observational studies fulfilled the eligibility criteria. Within the RCTs, five analysed FIN (n=161), two analysed plates (n=51) and five analysed EF (n=168). Within the observational studies, 13 analysed FIN (n=610), seven analysed plates (n=214) and six analysed EF (n=153). The overall risk of complications was lower following plate fixation when compared to FIN (RR 0.45, 95% CI 0.28 to 0.73, p=0.001) in the observational studies. The overall risk of complications was higher following EF when compared to FIN in both RCTs (RR 1.94, 95% CI 1.25 to 3.01, p=0.003) and observational studies (RR 1.97, 95% CI 1.50 to 2.58, p<0.001). The overall risk of complications was higher following EF when compared to plate fixation in both RCTs (RR 7.42, 95% CI 1.84 to 29.98, p=0.005) and observational studies (RR 4.39, 95% CI 2.64 to 7.30, p<0.001). Conclusions. This study reports a significantly decreased relative risk of complications when femoral diaphyseal fractures in children aged 4 to 12 are managed with plates. The overall quality of evidence is low, highlighting the need for a prospective multicentre randomised trial at low risk of bias due to randomisation and outcome measurement to identify if any fixation technique is superior


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 155 - 155
1 Nov 2021
Edwards T Daly C Donovan R Whitehouse M
Full Access

Introduction and Objective. The most common paediatric orthopaedic injury requiring hospital admission is a femoral fracture. There is debate regarding the optimal surgical technique for fixing femoral diaphyseal fractures in children aged 4 to 12 years. The National Institute for Health and Care Excellence (NICE) and the American Academy of Orthopaedic Surgeons (AAOS) have issued relevant guidelines, however, there is limited evidence to support these. The aim of this study was to conduct a systematic review and meta-analysis to compare the complication rate following flexible intramedullary nailing (FIN), plate fixation and external fixation (EF) for traumatic femoral diaphyseal fractures in children aged 4 to 12. Materials and Methods. We searched MEDLINE, EMBASE and CENTRAL databases for interventional and observational studies. Two independent reviewers screened, assessed quality and extracted data from the identified studies. The primary outcome was the risk of any complication. Secondary outcomes assessed the risk of pre-specified individual complications. Results. Nine randomised controlled trials (RCTs) and 19 observational studies (six prospective and 13 retrospective) fulfilled the eligibility criteria. Within the RCTs, five analysed FIN (n=161), two analysed plates (n=51) and five analysed EF (n=168). Within the observational studies, 13 analysed FIN (n=610), seven analysed plates (n=214) and six analysed EF (n=153). The overall risk of complications was lower following plate fixation when compared to FIN fixation (RR 0.45, 95% CI 0.28 to 0.73, p=0.001) in the observational studies. The overall risk of complications was higher following EF when compared to FIN fixation in both RCTs (RR 1.94, 95% CI 1.25 to 3.01, p=0.003) and observational studies (RR 1.97, 95% CI 1.50 to 2.58, p<0.001). The overall risk of complications was higher following EF when compared to plate fixation in both RCTs (RR 7.42, 95% CI 1.84 to 29.98, p=0.005) and observational studies (RR 4.39, 95% CI 2.64 to 7.30, p<0.001). Conclusions. Although NICE and the AAOS recommend FIN for femoral diaphyseal fractures in children aged 4 to 12, this study reports a significantly decreased relative risk of complications when these injuries are managed with plates. Our findings provide valuable information to healthcare professionals who are involved in discussing the risk and benefits of different management options with patients and their families. The overall quality of evidence is low, highlighting the need for a rigorous prospective multicentre randomised trial at low risk of bias due to randomisation and outcome measurement to identify if any fixation technique is superior


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 65 - 65
1 Dec 2021
Addai D Zarkos J Pettit M Kumar KHS Khanduja V
Full Access

Abstract. Objectives. Outcomes following different types of surgical intervention for FAI are well reported individually but comparative data is deficient. The purpose of this study was to conduct a systematic review (SR) and meta-analysis to analyse the outcomes following surgical management of FAI by hip arthroscopy (HA), anterior mini open approach (AMO) and surgical hip dislocation (SHD). Methods. This SR was registered with PROSPERO. An electronic database search of Pubmed, Medline and EMBASE for English and German language articles over the last 20 years was carried out according to the PRISMA guidelines. We specifically analysed and compared changes in patient reported outcome measures PROMs, α-angle, rate of complications, rate of revision and conversion to total hip arthroplasty (THA). Results. A total of 48 articles included for final analysis with a total of 4384 hips in 4094 patients. All subgroups showed a significant correction in mean alpha angle post-operatively with a mean change of 28.8° (95% CI, 21°-36.5°; p <0.01) after AMO, 21.1° (95% CI, 15.1°-27°; p <0.01) after SHD and 20.39° (95% CI, 15.66°-25.12°; p <0.01) after HA. AMO group showed a significantly higher increase in PROMs (3.7; 95% CI, 3.2–4.2; p <0.01) versus arthroscopy (2.47; 95% CI, 2.22–2.73; p <0.01) and SHD (2.4; 95% CI, 1.5–3.3; p <0.01). However, the rate of complications following AMO was significantly higher than HA and SHD. Conclusion. All three surgical approaches offered significant improvements in outcomes and radiological correction of cam deformities. All three groups showed similar rates of revision procedures and SHD had the highest rate of conversion to a THA. Revision rates was similar for all three revision procedures


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 12 - 12
1 Nov 2018
McQuail PM McCartney BS McKenna P
Full Access

Orthopaedic surgical site infections (SSI's) prolong total hospital stays by a median of 2 weeks per patient, approximately double re-hospitalization rates, and increase healthcare costs by more than 300%. Patients with orthopaedic SSI's have significant reductions in their health-related quality of life. We performed a systematic review and meta-analysis to compare differences in outcomes between use of sutures and non-absorbable staples for closure of orthopaedic surgical wounds in adults. The primary outcomes were rates of superficial and deep SSI. Secondary outcomes included wound dehiscence, length of hospital stay, patient satisfaction and pain during removal of closure material. Data sources including PubMed, EMBASE, Scopus, Web of Science, Cochrane Library, . clinicaltrials.gov. , National Institute for Health and Research, UK clinical trials gateway were searched for randomised controlled trials (RCT's) meeting inclusion criteria. Sixteen RCT's published between 1987 and 2017 were included. Overall, wound infection outcomes (superficial and deep infections combined) showed no statistically significant difference between closure with staples compared with sutures with arelative risk of 1.17 (95% CI 0.59–2.30, p=0.66). A subgroup was performed specific to hip wound infection outcomes. Interestingly, a sensitivity analysis demonstrated sutures to be statistically favourable (p=0.04) in terms of hip wound infection outcomes. There was no statistically significant difference among secondary outcomes between sutures and staple groups. Overall it appears the choice of sutures or staples in closure of orthopaedic wounds has no effect on wound complications. However, caution is needed in applying the findings to different population groups due to heterogeneity across studies


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 117 - 117
14 Nov 2024
Tirta M Rahbek O Kold S Husum HC
Full Access

Introduction

Selective screening of children at risk for developmental dysplasia of the hip (DDH) is based on clinical examination and risk factor identification. Two meta-analyses published in 2012 found breech presentation, family history of DDH, female sex and primiparity to increase the risk of DDH. However, the DDH definition, reference tests and age of the examined children vary considerably, complicating the translation of those findings to current screening guidelines. The aim of this meta-analysis was to evaluate the association of previously proposed risk factors to the risk of sonographically verified DDH.

Method

We searched PubMed, EMBASE and Cochrane library to identify cohort, RCTs, case-control and cross-sectional studies from 1980 to 2023 in English language. Eligible studies included participants under three months of age, where the diagnosis of DDH was made by hip ultrasound using the gold standard Graf method and reported information on one or more of the proposed risk factors and final diagnosis was available.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 44 - 44
1 Dec 2021
Pettit M Doran C Singh Y Saito M Kumar KHS Khanduja V
Full Access

Abstract

Objective

A higher prevalence of cam morphology has been reported in the athletic population but the development of the cam morphology is not fully understood. The purpose of this systematic review is to establish the timing of development of the cam morphology in athletes, the proximal femoral morphologies associated with its development, and other associated factors.

Methods

Embase, MEDLINE and the Cochrane Library were searched for articles related to development of the cam morphology, and PRISMA guidelines were followed. Data was pooled using random effects meta-analysis. Study quality was assessed using the Downs and Black criteria and evidence quality using the GRADE framework.


Introduction

Patellar tendinopathy is a highly prevalent clinical diagnosis supported by ultrasound changes. Numerous interventions are targeted at improving both symptoms and structure of dysfunctional tendons, however little is known of the diagnostic value in a changing ultrasound profile whilst patient reported outcome measures determine recovery. The aim of this study was to assess if change in ultrasound measure is congruent with change in Victorian Institute of Sport Assessment – Patella (VISA-P) score and therefore indicates the use of using ultrasound to assess patellar tendinopathy during symptom change.

Method

Four databases (PubMed, Web of Science, Embase, Cinahl) were search in January 2014. Studies selected contained ultrasound and VISA-P scores from ≥ 2 type points. All included studies were quality assessed depending on type and available data underwent meta-analysis.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 33 - 33
14 Nov 2024
Fallahy M Shaker F Ghanbari F Aslani MA Mohammadi S Behrouzieh S
Full Access

Introduction

Knee Osteoarthritis (KOA) is a prevalent joint disease requiring accurate diagnosis and prompt management. The condition occurs due to cartilage deterioration and bone remodeling. Ultrasonography has emerged as a promising modality for diagnosing KOA. Medial meniscus extrusion (MME), characterized by displacement of medial meniscus beyond the joint line has been recognized as a significant marker of KOA progression. This study aimed to explore potentials Ultrasound findings in timely detection of MME and compare it to magnetic resonance imaging (MRI) as a reference standard.

Method

A comprehensive literature search was performed in 4 databases from inception to May 1 2024. Two independent reviewers, initiated screening protocols and selected the articles based on inclusion and exclusion criteria and then extracted the data. Meta-analysis was conducted using R 4.3.2 packages mada and metafor.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 57 - 57
4 Apr 2023
Tariq M Uddin Q Amin H Ahmed B
Full Access

This study aims to compare the outcomes of Volar locking plating (VLP) versus percutaneous Kirschner wires (K-wire) fixation for surgical management of distal radius fractures.

We systematically searched multiple databases, including MEDLINE for randomized controlled trials (RCTs) comparing outcomes of VLP fixation and K-wire for treatment of distal radius fracture in adults. The methodological quality of each study was assessed by the Cochrane Risk of Bias tool. Patient-reported outcomes, functional outcomes, and complications at 1 year follow up were evaluated. Meta-analysis was performed using random-effects models and results presented as risk ratios (RRs) or mean differences (MDs) with 95% confidence interval (CI).

13 RCTs with 1336 participants met the inclusion criteria. Disabilities of the Arm, Shoulder and Hand (DASH) scores were significantly better for VLP fixation (MD= 2.15; 95% CI, 0.56-3.74; P = 0.01; I2=23%). No significant difference between the two procedures for grip strength measured in kilograms (MD= −3.84; 95% CI,-8.42-0.74; P = 0.10; I2=52%) and Patient-Rated Wrist Evaluation (PRWE) scores (MD= −0.06; 95% CI,-0.87-0.75; P = 0.89; I2=0%). K-wire treatment yielded significantly improved extension (MD= −4.30; P=0.04) but with no differences in flexion, pronation, supination, and radial deviation (P >0.05). The risk of complications and rate of reoperation were similar for the two procedures (P >0.05).

This meta-analysis suggests that VLP fixation improves DASH score at 12 months follow up, however, the difference is small and unlikely to be clinically important. Existing literature does not provide sufficient evidence to demonstrate the superiority of either VLP or K-wire treatment in terms of patient-reported outcomes, functional outcomes, and complications.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 27 - 27
1 Dec 2021
Edwards T Donovan R Whitehouse M
Full Access

Abstract

Objectives

Intra-articular corticosteroid injections (IACIs) are a well-established non-surgical treatment for the symptoms of osteoarthritis (OA), which can provide short-term improvements in pain, disability and quality of life (QoL). Many patients receive recurrent IACIs as temporary relief of their symptoms. Longer-term outcomes for recurrent IACIs remain less well-researched. This meta-analysis aimed to investigate the longer-term risks and benefits of IACIs beyond 3 months.

Methods

We searched MEDLINE, EMBASE, and CENTRAL from inception to January 07, 2021, for randomised controlled trials (RCTs) where patients with OA had received recurrent IACIs. Our primary outcomes were pain and function. Secondary outcomes included QoL, disease progression, radiological changes, and adverse events. Mean differences with 95% confidence intervals were reported.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 60 - 60
14 Nov 2024
Asgari A Shaker F Fallahy MTP Soleimani M Shafiei SH Fallah Y
Full Access

Introduction

Shoulder arthroplasty (SA) has been performed with different types of implants, each requiring different replacement systems. However, data on previously utilized implant types are not always available before revision surgery, which is paramount to determining the appropriate equipment and procedure. Therefore, this meta-analysis aimed to evaluate the accuracy of the AI models in classifying SA implant types.

Methods

This systematic review was conducted in Pubmed, Embase, SCOPUS, and Web of Science from inception to December 2023, according to PRISMA guidelines. Peer-reviewed research evaluating the accuracy of AI-based tools on upper-limb X-rays for recognizing and categorizing SA implants was included. In addition to the overall meta-analysis, subgroup analysis was performed according to the type of AI model applied (CNN (Convolutional neural network), non-CNN, or Combination of both) and the similarity of utilized datasets between studies.