Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 37 - 37
14 Nov 2024
Zderic I Kraus M Axente B Dhillon M Puls L Gueorguiev B Richards G Pape HC Pastor T Pastor T
Full Access

Introduction. Distal triceps tendon rupture is related to high complication rates with up to 25% failures. Elbow stiffness is another severe complication, as the traditional approach considers prolonged immobilization to ensure tendon healing. Recently a dynamic high-strength suture tape was designed, implementing a silicone-infused core for braid shortening and preventing repair elongation during mobilization, thus maintaining constant tissue approximation. The aim of this study was to biomechanically compare the novel dynamic tape versus a conventional high-strength suture tape in a human cadaveric distal triceps tendon rupture repair model. Method. Sixteen paired arms from eight donors were used. Distal triceps tendon rupture tenotomies and repairs were performed via the crossed transosseous locking Krackow stitch technique for anatomic footprint repair using either conventional suture tape (ST) or novel dynamic tape (DT). A postoperative protocol mimicking intense early rehabilitation was simulated, by a 9-day, 300-cycle daily mobilization under 120N pulling force followed by a final destructive test. Result. Significant differences were identified between the groups regarding the temporal progression of the displacement in the distal, intermediate, and proximal tendon aspects, p<0.001. DT demonstrated significantly less displacement compared to ST (4.6±1.2mm versus 7.8±2.1mm) and higher load to failure (637±113N versus 341±230N), p≤0.037. DT retracted 0.95±1.95mm after each 24-hour rest period and withstood the whole cyclic loading sequence without failure. In contrast, ST failed early in three specimens. Conclusion. From a biomechanical perspective, DT revealed lower tendon displacement and greater resistance in load to failure over ST during simulated daily mobilization, suggesting its potential for earlier elbow mobilization and prevention of postoperative elbow stiffness


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 39 - 39
14 Nov 2024
Dhillon M Pastor T Zderic I Pastor T Gueorguiev B
Full Access

Introduction. Recently, a new dynamic high-strength round suture dynacord (DC) was introduced featuring a salt-infused silicone core attracting water in a fluid environment to preserve tissue approximation which is also available in tape form (DT). Study aims: (1) assess the influence of securing knot number on knot security of two double-stranded knot configurations (Cow-hitch and Nice-knot) tied with either dynamic (DC and DT) or conventional round sutures fiberwire (FW) and conventional suture tapes (ST), (2) compare the ultimate force and knot slippage of (a) Cow-hitch and Nice-knot and (b) DC and DT versus FW and FT at their minimal number of needed securing knots. Method. Seven specimens of each FW, ST, DC and DT were considered for tying with Cow-hitch or Nice-knots. The base of these Cow-hitch and Nice-knots were secured with surgeons’ knots using 1-3 alternating throws. Tensile tests were conducted under physiologic conditions to evaluate knot slippage, ultimate force at rupture, and minimum number of knots ensuring 100% knot security. Result. 100% knot security for both Cow-hitch and Nice-knots was achieved with 2 securing knots for DC, DT, ST, and with 3 securing knots for FW. With these minimum number of securing knots ultimate force was significantly higher for Nice-knots versus Cow-hitch in DT (p=0.001) and slippage was significantly higher in Cow-hitch versus Nice-knot tied with DC (p=0.019). Conclusion. The minimum number of securing knots required to achieve 100% knot security was 2 for DC, DT and ST both with Cow-hitch and Nice-knots. In contrast, 3 securing knots were needed in FW. With these minimum number of securing knots Nice-knots were associated with higher ultimate forces in DT and lower slippage in DC versus Cow-hitch knots. Furthermore, the novel self-tightening suture material (DT and DC) does not reduce slippage, which is unavoidable in all used sutures


Bone & Joint Research
Vol. 6, Issue 2 | Pages 82 - 89
1 Feb 2017
Nagra NS Zargar N Smith RDJ Carr AJ

Objectives

All-suture anchors are increasingly used in rotator cuff repair procedures. Potential benefits include decreased bone damage. However, there is limited published evidence for the relative strength of fixation for all-suture anchors compared with traditional anchors.

Materials and Methods

A total of four commercially available all-suture anchors, the ‘Y-Knot’ (ConMed), Q-FIX (Smith & Nephew), ICONIX (Stryker) and JuggerKnot (Zimmer Biomet) and a traditional anchor control TWINFIX Ultra PK Suture Anchor (Smith & Nephew) were tested in cadaveric human humeral head rotator cuff repair models (n = 24). This construct underwent cyclic loading applied by a mechanical testing rig (Zwick/Roell). Ultimate load to failure, gap formation at 50, 100, 150 and 200 cycles, and failure mechanism were recorded. Significance was set at p < 0.05.