Advertisement for orthosearch.org.uk
Results 1 - 18 of 18
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 9 - 9
4 Apr 2023
Fridberg M Annadatha S Hua Q Jensen T Liu J Kold S Rahbek O Shen M Ghaffari A
Full Access

To detect early signs of infection infrared thermography has been suggested to provide quantitative information. Our vision is to invent a pin site infection thermographic surveillance tool for patients at home. A preliminary step to this goal is the aim of this study, to automate the process of locating the pin and detecting the pin sites in thermal images efficiently, exactly, and reliably for extracting pin site temperatures. A total of 1708 pin sites was investigated with Thermography and augmented by 9 different methods in to totally 10.409 images. The dataset was divided into a training set (n=8325), a validation set (n=1040), and a test set (n=1044) of images. The Pin Detection Model (PDM) was developed as follows: A You Only Look Once (YOLOv5) based object detection model with a Complete Detection Intersection over Union (CDIoU), it was pre-trained and finetuned by the through transfer learning. The basic performance of the YOLOv5 with CDIoU model was compared with other conventional models (FCOS and YOLOv4) for deep and transition learning to improve performance and precision. Maximum Temperature Extraction (MTE) Based on Region of Interest (ROI) for all pin sites was generated by the model. Inference of MTE using PDM with infected and un-infected datasets was investigated. An automatic tool that can identify and annotate pin sites on conventional images using bounding boxes was established. The bounding box was transferred to the infrared image. The PMD algorithm was built on YOLOv5 with CDIoU and has a precision of 0.976. The model offers the pin site detection in 1.8 milliseconds. The thermal data from ROI at the pin site was automatically extracted. These results enable automatic pin site annotation on thermography. The model tracks the correlation between temperature and infection from the detected pin sites and demonstrates it is a promising tool for automatic pin site detection and maximum temperature extraction for further infection studies. Our work for automatic pin site annotation on thermography paves the way for future research on infection assessment using thermography


Bone & Joint Research
Vol. 4, Issue 3 | Pages 45 - 49
1 Mar 2015
Thompson MJ Ross J Domson G Foster W

Objectives. The clinical utility of routine cross sectional imaging of the abdomen and pelvis in the screening and surveillance of patients with primary soft-tissue sarcoma of the extremities for metastatic disease is controversial, based on its questionable yield paired with concerns regarding the risks of radiation exposure, cost, and morbidity resulting from false positive findings. Methods. Through retrospective review of 140 patients of all ages (mean 53 years; 2 to 88) diagnosed with soft-tissue sarcoma of the extremity with a mean follow-up of 33 months (0 to 291), we sought to determine the overall incidence of isolated abdominopelvic metastases, their temporal relationship to chest involvement, the rate of false positives, and to identify disparate rates of metastases based on sarcoma subtype. Results. A total of four patients (2.9%) exhibited isolated abdominopelvic metastatic disease during the surveillance period. In all cases of concomitant chest and abdominopelvic disease, chest involvement preceded abominopelvic involvement. There was a significant false positive rate requiring invasive workup. Conclusions. In the setting of a relative paucity of evidence concerning a rare disease process and in difference to recently published investigations, we add a clinical cohort not supportive of routine cross sectional imaging of the abdomen and pelvis. Cite this article: Bone Joint Res 2015;4:45–9


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 98 - 98
1 Nov 2021
Fridberg M Rahbek O Husum H Ghaffari A Kold S
Full Access

Introduction and Objective. Digital infra-red thermography may have the capability of identifying local inflammations. Nevertheless, the role of thermography in diagnosing pin site infection has not been explored yet and the reliability and validity of this method for pin site surveillance is in question. The purpose of this study was to explore the capability and intra-rater reliability of thermography in detecting pin site infection. Materials and Methods. This explorative proof of concept study follows GRRAS -guidelines for reporting reliability and agreement studies. After clinical assessment of pin sites by one examiner using Modified Gordon Pin Infection Classification (Grade 0 – 6), thermographic images of the pin sites were captured with a FLIR C3 camera and analyzed by the FLIR tools software package. The maximum skin temperature around the pin site and the maximum temperature for the whole thermographic picture was measured. Intra-rater agreement was established and test-retests were performed with different camera angles. Results. Thirteen (4 females) patients (age 9–72 years) were included. Indications for frames: 4 fracture, 2 deformity correction, 1 lengthening, 6 bone transport. Days from surgery to thermography ranged from 27 to 385 days. Overall, 231 pin sites were included. Eleven pin sites were diagnosed with early signs of infection: five grade 1, five grade 2, one grade 3. Mean pin site temperature was 33.9 °C (29.0–35.4). With 34 °C as cut-off value for infection, sensitivity was 73%, specificity 67%, positive predictive value 10% and negative predictive value 98%. Intra-rater reliability for thermography was ICC 0.85 (0.77–0.92). The temperature measured was influenced by the camera postioning in relation to pin site with a variance of 0.2. Conclusions. Measurements of pin sites using the handheld FLIR C3 infrared camera was a reliable method and the temperature was related to infection grading. This study demonstrates that digital thermography with a handheld camera might be used for monitoring the pin sites after operations to detect early infection, however, future larger prospective studies are necessary


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 87 - 87
1 Apr 2018
Fujito T Tomita T Yamazaki T Futai K Ishibashi T Yoshikawa H Sugamoto K
Full Access

Purpose. This study was to investigate the effect of posterior tibial slope (PTS) on the kinematics in the cruciate-retaining total knee arthroplasty (CR-TKA) using 2- to 3- dimensional registration technique. Material & Methods. A total of 75 knees in 58 patients were recruited and categorized into the following two groups according to PTS. Group A was categorized PTS under 7degrees (n = 33) and group B was categorized PTS over 7 degrees (n = 42). The average age of group A and group B at the time of fluoroscopic surveillance date was 73.5 ± 7.4 years and 74.3 ± 4.5 years, respectively and the average follow-up period from operation date to fluoroscopic surveillance date was 13.8 ± 9.3 months and 16.7 ± 8.6 months, respectively. In vivo kinematics during sequential deep knee bending under weight-bearing condition were evaluated using fluoroscopic image analysis and 2- to 3- dimensional registration technique. Range of motion (ROM), axial rotation, anteroposterior (AP) translations of medial and lateral nearest points of the femoral component relative to the tibial component were measured and compared between the two groups. The nearest points were determined by calculating the closest distance between the surfaces of femoral component model and the axial plane of coordinate system of the tibial component. We defined external rotation and anterior translation as positive. P values under 0.05 was defined as statistically significant. Results. The mean PTS in group A and B were 5.5 ± 1.4°and 9.9 ± 1.9°, respectively. There was no statistically significant difference in the degrees of axial rotation from 0° to 110° of flexion between the two groups (4.9 ± 4.2° vs 5.2 ± 4.2°, p > 0.05), respectively. The hyperextension of group B were significantly larger than group A (−2.3 ± 6.6°vs −9.8 ± 8.7°, p <0.05). The ROM of group B were significantly larger than group A (118.7 ± 10.8°vs 128.7 ± 17.7°, p <0.05). However, there was no significant difference in the maximum flexion between the two groups (116.4 ±10.8°vs 118.9±14.5°, p >0.05), respectively. In terms of AP translation, medial nearest points were located significantly more posterior at 0°, 10°, 30°, 40° of flexion in group B compared to group A. There was no significant difference in the location of lateral nearest points between the two groups during all knee range of motion. Discussion/Conclusion. The results shown in this study demonstrated that the PTS influenced the kinematics and ROM under weight-bearing condition in CR-TKA. The large PTS induced great posterior displacement of medial nearest points during early flexion phase and increased hyperextension between the femoral and tibial components


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 97 - 97
1 Jan 2017
Fujito T Tomita T Futai K Yamazaki T Kenichi K Yoshikawa H Sugamoto K
Full Access

We hypothesized that using the navigation system, intra-operative knee kinematics after implantation measured may predict that post-operative kinematic in activities of daily living. Our aim was to compare intra-operative knee kinematics by a computed tomography (CT)-based navigation system and post-operative by the 2- to 3-dimensional registration techniques (2D3D). This study were performed for 8 patients (10 knees, medial osteoarthritis) who underwent primary PS TKA using CT-based navigation system. The median follow-up period from operation date to fluoroscopic surveillance date was 13 months (range 5 – 37 months). Navigation and 2D3D had a common coordinate origin for components. Medial and lateral femoral condyle anterior-posterior translation (MFT and LFT) were respectively defined as the distance of the projection of the points (which was set on the top of the posterior femoral pegs) onto the axial plane of the tibial coordinate system. Intraoperative kinematics was measured using the navigation system after final implantation and closure of the retinaculum during passive full flexion and extension imposed by the surgeon. Under fluoroscopic surveillance in the sagittal plane, each patient was asked to perform sequential deep knee flexion under both weight bearing (WB) and non-weight bearing (NWB) conditions from full extension to maximum flexion. Repeated two-way ANOVA (tasks × flexion angles) were used, and then post-hoc test (paired t-tests with Boferroni correction) were performed. The level of statistical significant difference was set at 0.05 on two-way ANOVAs and 0.05 / 3 on post-hoc paired t-tests. Mean range of motion between femoral and tibial components were Intra-operative (Intra): 28.0 ± 9.7, NWB conditions: 120.6 ± 11.1, WB conditions: 125.1 ± 12.9°, respectively. Mean ER (+) / IR (−) from 0° to 120° were Intra-operative (Intra): 9.3 ± 10.2°, NWB conditions: 8.1 ± 8.9, WB conditions: 5.2 ± 7.0, respectively. Mean MFT /LFT from 0° to 90° were Intra; 4.4 ±14.8/ 4.2± 8.5mm, NWB; 6.2 ± 6.9 / 9.2 ± 3.1 mm, WB; 9.2 ± 3.5 / 7.4 ± 2.8 mm, respectively. Mean MFT /LFT from 90° to 120° were Intra; −4.4 ± 2.5 / −5.7 ± 2.9 mm, NWB; −5.5 ± 1.8 / −8.2 ± 0.6 mm, WB; −4.0 ± 1.9 / −5.4 ± 2.3mm, respectively. Mean ADD/ABD from 0° to 120° were Intra;-4.2 ± 3.0, NWB; −0.2 ± 2.1, WB; −0.1 ± 0.8, respectively. Repeated two-way ANOVA showed a significant all interaction on kinematic variables (p<0.05). No statistically significant difference at post-hoc test was found in ER/ IR of all tasks and MFT /LFT of Intra vs NWB and Intra vs WB from 0° to 120° (p>0.05 / 3). The Conditions of these tasks were different from each others. Our study demonstrated that intra-operative kinematics could predict post-operative kinematics


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 87 - 87
1 Nov 2018
Fujito T Tomita T Yamazaki T Tamaki M Ishibashi T Kono K Konda S Yoshikawa H Sugamoto K
Full Access

Our aim was to investigate whether it is possible to predict post-operative kinematics (Post-Ope) from intra-operative kinematics (Intra-Ope) after total knee arthroplasty. Our study were performed for 11 patients (14 knees) who underwent primary PS TKA using CT-based navigation system between Sept.2012 and Sept.2014. The mean subject age was 71.5 ± 5.5 years at the time of surgery. Intra-Ope was measured using the navigation system after implantation during passive full extension and flexion imposed by the surgeon. Under fluoroscopic surveillance, each patient was asked to perform sequential deep knee flexion under both non-weight bearing (NWB) and weight bearing (WB) conditions from full extension to maximum flexion. To estimate the spatial position and orientation, we used a 2- to 3- dimensional (2D3D) registration technique. Intra-Ope and Post-Ope had a common coordinate axis for bones. Evaluations were range of motion (ROM), external rotation angles (ER). The level of statistical significant difference was set at 0.05. Mean ROM in Intra-Ope(130°± 7.9°) was statistically larger than both NWB(121.1°±10.5°) and WB(124.0°±14.7°). No Statistically significant difference was found in the mean ER from 10° to 120° among Intra-Ope (11.2°± 8.5°) and NWB(7.1°±6.0°) and WB(5.3°±3.2°). It is suggested that we could predict Post-Ope from Intra-Ope by considering the increase of the range of motion due to the muscle relaxation condition and the amount of change in the ER


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 49 - 49
1 Jul 2014
Gwyn R Mahmood S Malik I Maheson M John A Lyons C Jones S
Full Access

Summary. 162 patient cohort with serial Metal Artefact Reduction Sequence MRI scans. Patients with normal initial scans can be followed up at 1 year. Those with abnormal scans should be followed up at a shorter interval of 6 months. Introduction. Cross-sectional imaging is a key investigation in the assessment and surveillance of patients with metal-on-metal (MoM) hip arthroplasty. We present our experience of Metal Artefact Reduction Sequence (MARS) MRI scanning in metal on metal hip arthroplasty. We aimed to investigate the natural history and radiological disease progression from Adverse Reactions to Metallic Debris. Methods. A total cohort of 626 patients who had metal on metal arthroplasty underwent MARS MRI scanning with 162 patients having more than one MRI scan. A musculoskeletal radiologist reviewed and reported on all MRI scans. The findings were described as either normal or classified according to Hart et al. We then considered the patient's progression between groups on serial scans and the time intervals between them. Results. 65 patients had a normal first MRI, 38 (54%) remained normal on follow-up scan with a mean scanning interval of 14.6 months. The remaining 27 patients who progressed form normal to either Type 1/2/3 did so over a mean scan interval of 14 months. Of those 56 patients with a Type 1 (thin walled fluid collection) 28.5% of these progressed during interval scanning and 8.9% of Type 1 reactions returned to normal. Over half the patients with an abnormal initial MARS MRI scan 46/85 (54%), with either Type 1 or 2 abnormal soft tissue reaction, had progressed to more severe types following a mean interval scan time of 12.2 months. Discussion. A safe interval for a follow-up MARS MRI scanning in a patient who has normal initial findings appears to be 12 months. We consider a 6-month scan appropriate for patients under surveillance who have initial abnormal cross-sectional imaging


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 167 - 167
1 Jul 2014
Iwamoto K Tomita T Yamazaki T Sasaki A Kii Y Futai K Miyamoto T Fujii M Yoshikawa H Sugamoto K
Full Access

Summary. The effect of the geometry of the tibial polyethylene insert was investigated in vivo loaded conditions. Introduction. The decision to choose CR (cruciate retaining) insert or CS (condylar stabilised) insert during TKA remains a controversial issue. Triathlon CS type has a condylar stabilised insert with an increased anterior lip that can be used in cases where the PCL is sacrificed but a PS insert is not used. The difference of the knee kinematics between CR and CS insert remains unclear. This study measured knee kinematics of deep knee flexion under load in two insert designs using 2D/3D registration technique. Patients and Methods. We investigated the in vivo knee kinematics of 20 knees (18 patients) implanted with Triathlon CR components (Stryker Orthopedics, Mahwah, NJ), 10 knees in the CR insert with retaining PCL, and 10 knees in the CS insert with sacrificing PCL. All TKAs were judged clinically successful (Knee Society knee scores >90), with no ligamentous laxity or pain. Mean patient age at the time of operation was 72±12 years in CR and 69±9 years in CS. Mean period between operation and surveillance was 20±11 months in CR and 11±5 months in CS. Under fluoroscopic surveillance, each patient did a wight-bearing deep knee bending motion. Femorotibial motion including tibial polyethylene insert was analyzed using 2D/3D registration technique, which uses computer-assisted design (CAD) models to reproduce the spatial position of the femoral, tibial components from single-view fluoroscopic images. We evaluated the range of motion, femoral axial rotation, and antero-posterior (AP) translation of the nearest points. Results. The average range of motion between femoral component and tibial component was 113.3±22.3° in CR and 107.4±13.1° in CS. The amount of femoral axial rotation from 0° to 110° flexion was 8.6±2.9° in CR insert, and 7.6±2.6° in CS insert, respectively. No significant difference was observed in the amount of femoral external rotation (p=0.71). In CR insert, the medial contact point moved 4.0±2.9mm anteriorly from 0° to 100° flexion. The lateral contact point moved 2.0±1.1mm anteriorly from 60° to 90° flexion. In CS insert, the medial contact point moved 6.4±2.1mm anteriorly from 20° to 100° flexion. The lateral contact point moved 1.9±1.7mm anteriorly from 50° to 110° flexion. There was significant differences were observed in the amount of medial anterior translation between the two insert (medial; p=0.04, lateral; p=0.94). Discussion and Conclusion. Triathlon CR and CS insert had a similar kinematics pattern. However, there was significant differences were observed in the amount of medial anterior translation between the two insert. These results indicated that the increased anterior lip could not control medial anterior sliding. The posterior part of the two insert were almost same, so the kinematics are similar


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 6 - 6
1 Jan 2017
Li L St Mart J Tweedie B Kurek N Somasundaram K Huber C Babu V
Full Access

There has been evidence of association between femoral shaft fractures and prolonged bisphosphonate therapy. We present a case series of bisphosphonate-associated fractures and invaluable lessons we have learnt. Over the last three years at our unit we have collected a case series of eight patients who have had atypical femoral fractures whilst on bisphosphonate therapy. We present illustrative cases, a summary of key findings, and invaluable lessons we have learnt. There was a long period of prodromal pain for two years before incomplete fractures developed. We speculate this is a warning sign of impending fracture. This may have been prevented with screening. Between incomplete fracture and complete fracture there was a short window of one month. Five patients presented with complete fracture, and three with thigh pain +/- evidence of incomplete fracture. Of the latter group all but one went on to develop complete fractures. The one patient who did not progress died six years after diagnosis. Of those five patients who presented with initial complete fracture, three patients recall thigh pain before fracture on further questioning. Despite being diaphyseal femoral fractures, there is a higher risk of neck of femur fractures in this patient cohort (both patients with initial interlocked nails subsequently developed neck of femur fractures soon after and were revised to cephalomedullary nails). Excluding one death from unrelated cause, only one patient has signs of complete fracture healing. All other patients are still receiving follow-up (mean 490 days). Three patients reported bilateral symptoms (pain). Two had had bilateral symptoms for one year. Both had visible incomplete fractures on further radiographic scrutiny; one underwent prophylactic cephalomedullary nailing, one was managed with active surveillance. We suggest that improved pain and radiographic changes of cortical healing may be misleading and should not be relied upon. Cephalomedullary nailing is the treatment of choice in these fractures due to higher risk of neck of femur fractures in this cohort. We suggest prompt prophylactic cephalomedullary nailing when radiographic incomplete fractures are identified due to a short window before progression to complete fracture, and the need to consider contralateral prophylactic nailing in patients describing bilateral symptoms. We speculate that thigh pain is a warning sign of impending fracture and fracture-progression can be prevented with appropriate screening


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 25 - 25
1 Jan 2017
Shih K Lin C Lu H Lin C Lu T
Full Access

Total knee replacements (TKR) have been the main choice of treatment for alleviating pain and restoring physical function in advanced degenerative osteoarthritis of the knee. Recently, there has been a rising interest in minimally invasive surgery TKR (MIS-TKR). However, accurate restoration of the knee axis presents a great challenge. Patient-specific-instrumented TKR (PSI-TKR) was thus developed to address the issue. However, the efficacy of this new approach has yet to be determined. The purpose of the current study was thus to measure and compare the 3D kinematics of the MIS-TKR and PSI-TKR in vivo during sit-to-stand using a 3D fluoroscopy technology. Five patients each with MIS-TKR and PSI-TKR participated in the current study with informed written consent. Each subject performed quiet standing to define their own neutral positions and then sit-to-stand while under the surveillance of a bi-planar fluoroscopy system (ALLURA XPER FD, Philips). For the determination of the 3D TKR kinematics, the computer-aided design (CAD) model of the TKR for each subject was obtained from the manufacturer including femoral and tibial components and the plastic insert. At each image frame, the CAD model was registered to the fluoroscopy image via a validated 2D-to-3D registration method. The CAD model of each prosthesis component was embedded with a coordinate system with the origin at the mid-point of the femoral epicondyles, the z-axis directed to the right, the y-axis directed superiorly, and the x-axis directed anteriorly. From the accurately registered poses of the femoral and tibial components, the angles of the TKR were obtained following a z-x-y cardanic rotation sequence, corresponding to flexion/extension, adduction/abduction and internal/external rotation. During sit-to-stand the patterns and magnitudes of the translations were similar between the MIS-TKR and PSI-TKR groups, with posterior translations ranging from 10–20 mm and proximal translations from 29–31mm. Differences in mediolateral translations existed between the groups but the magnitudes were too small to be clinically significant. For angular kinematics, both groups showed close-to-zero abduction/adduction, but the PSI-TKR group rotated externally from an internally rotated position (10° of internal rotation) to the neutral position, while the MIS-TKR group maintained at an externally rotated position of less than 5° during the movement. During sit-to-stand both groups showed similar patterns and magnitudes in the translations but significant differences in the angular kinematics existed between the groups. While the MIS-TKR group maintained at an externally rotated position during the movement, the PSI-TKR group showed external rotations during knee extension, a pattern similar to the screw home mechanism in a normal knee, which may be related to more accurate restoration of the knee axis in the PSI-TKR group. A close-to-normal angular motion may be beneficial for maintaining a normal articular contact pattern, which is helpful for the endurance of the TKR. The current study was the first attempt to quantify the kinematic differences between PSI and non-PSI MIS. Further studies to include more subjects will be needed to confirm the current findings. More detailed analysis of the contact patterns is also needed


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 23 - 23
1 Jan 2017
Kono K Tomita T Futai K Yamazaki T Fujito T Tanaka S Yoshikawa H Sugamoto K
Full Access

The purpose of this study is to investigate the three-dimensional (3D) kinematics of normal knees in deep knee-bending motions like squatting and kneeling. Material & Methods: We investigated the in vivo kinematics of 4 Japanese healthy male volunteers (8 normal knees in squatting, 7 normal knees in kneeling). Each sequential motion was performed under fluoroscopic surveillance in the sagittal plane. Femorotibial motion was analyzed using 2D/3D registration technique, which uses computer-assisted design (CAD) models to reproduce the spatial position of the femur and tibia from single-view fluoroscopic images. We evaluated the femoral rotation relative to the tibia and anteroposterior (AP) translation of the femoral sulcus and lateral epicondyle on the plane perpendicular to the tibial mechanical axis. Student's t test was used to analyze differences in the absolute value of axial rotation and AP translation of the femoral sulcus and lateral epicondyle during squatting and kneeling. Values of P < 0.05 were considered statistically significant. During squatting, knees were gradually flexed from −2.8 ± 1.3° to 145.5 ± 5.1° on average. Knees were gradually flexed from 100.8 ± 3.9° to 155.6 ± 3.2° on average during kneeling. Femurs during squatting displayed sharp external rotation relative to the tibia from 0° to 30° of flexion and it reached 12.5 ± 3.3° on average. From 30° to 130° of flexion, the femoral external rotation showed gradually, and it reached 19.1 ± 7.3° on average. From 130° to 140° of flexion, it was observed additionally, and reached 22.4 ± 6.1° on average. All kneeling knees displayed femoral external rotation relative to the tibia sharply from 100° to 150° of flexion, and it reached 20.7 ± 7.5° on average. From 100° to 120° of flexion, the femoral external rotation during squatting was larger than that during kneeling significantly. From 120° to 140° of flexion, there was no significant difference between squatting and kneeling. The sulcus during squatting moved 4.1 ± 4.8 mm anterior from 0° to 60° of flexion. From 60° of flexion it moved 13.6 ± 13.4 mm posterior. The sulcus during kneeling was not indicated significant movement with the knee flexion. The lateral epicondyle during squatting moved 39.4 ± 7.7 mm posterior from 0° to 140° of flexion. The lateral epicondyle during kneeling moved 22.0 ± 5.4 mm posterior movement from 100° to 150° of flexion. In AP translation of the sulcus from 100° to 140° of flexion, there was no significant difference between squatting and kneeling. However in that of the lateral epicondyle, squatting groups moved posterior significantly. Even if they were same deep knee-bending, the kinematics were different because of the differences of daily motions. The results in this study demonstrated that in vivo kinematics of deep knee-bending were different between squatting and kneeling


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 11 - 11
1 Mar 2013
Matthies A Suarez A Karbach L Henckel J Skinner J Noble P Hart A
Full Access

There are several component position and design variables that increase the risk of edge loading and high wear in metal-on-metal hip resurfacing (MOM-HR). In this study we combined all of these variables to calculate the ‘contact patch to rim distance’ (CPRD) in patients undergoing revision of their MOM-HR. We then determined whether CPRD was more strongly correlated with component wear and blood metal ion levels, when compared to any other commonly reported clinical variable. This was a retrospective study of 168 consecutively collected MOM-HR retrieval cases. All relevant clinical data was documented, including pre-revision whole blood cobalt and chromium ion levels. Wear of the bearing surfaces was then measured using a roundness-measuring machine. We found four variables to be significantly (p < 0.05) correlated with component wear and blood metal ion levels: (1) cup inclination angle, (2) cup version angle, (3) arc of cover, and (4) CPRD. The correlations between CPRD and both wear and ion levels were significantly stronger than those seen with any other variable (all p < 0.0001). Our study has shown that CPRD is the best predictor of component wear and blood metal ion levels, and may therefore be a useful parameter to help determine those patients who are at risk of high wear and require more frequent clinical surveillance


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 13 - 13
1 Aug 2013
Challagundla SR Shewale S
Full Access

Introduction of new implants has been widely debated lately, mainly in response to the problems surrounding hip resurfacing and one company recalling its product. Medicines and Healthcare products Regulatory Agency (MHRA) also issued advice about the management and monitoring of patients implanted with metal-on-metal articulations. In response to MHRA advice all the patients who underwent hip resurfacing in our hospital were assessed by two consultants according to MHRA guidelines. Here we present the findings from our District General Hospital. Between November 2006 and March 2009 we performed 42 hip resurfacings in 39 patients. Nearly all the procedures were performed by a single surgeon (39 out of 42). There were 27 males (28 hips) and 12 females (14 hips). Mean age of the patients at the time of surgery was 55.6 years (age range 40–67 years). Patients were followed up for a mean of 49 months (range 33–66 months). 27 patients (28 hips) were asymptomatic at the time of last follow up. Serum cobalt and chromium ion levels were measured in 21 patients (24 hips). Both the ion levels were within the recommended levels in 20 patients and over the recommended limit in 2 patients (one with bilateral hip resurfacing). MRI was diagnostic in 2 out of 5 patients. 5 patients (7 hips) were revised (one hip for neck resorption, 4 hips in 3 patients with lesions on MRI, 1 patient with bilateral hips for elevated serum ion levels). Considering the revision rate (7 hips out of 42 hips, 16%), we do believe that the review of the hip resurfacings in spite of the controversies surrounding the diagnostic criteria is necessary. This group of patients need to have continued surveillance, preferably by a select group of surgeons


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 21 - 21
1 Aug 2013
Ferrell P Murray O Campton J
Full Access

Total hip replacement (THR) is an option in a subset of patients with a neck of femur (NOF) fracture. The Scottish Intercollegiate Guidelines Network (SIGN) and National Institute for Clinical Excellence (NICE) provide guidance on the use of THR in patients with a NOF fracture. We compare our experience and recommend changes at a local level to allow successful implementation of the guideline to improve patient care. From July 2008 to July 2011, 36 THRs preformed for trauma were identified retrospectively by cross-referencing several databases (Bluespier, Worcestershire, UK and surveillance of Surgical Site Infection (SSI), Scotland). 7 exclusions (3 failed internal fixation, 1 chronic NOF fracture, and 2 extra-capsular fractures) leaving 29 patients. All operations were carried out under the supervision of a hip surgeon. Outcome data (see results) was collected from electronic sources. Statistical analysis preformed using Fisher's exact test for categorical data. Median age 62 years (44–88), time to surgery 4 days (2–8), American association of anaesthesia grade 2 (2–4) and hospital stay was 12 days (6–18). The first operator was a consultant in 23 cases and registrar in 6. 9 hips were cemented, 5 uncemented and 15 hybrid. 13 (44.8%) patients had a complication including 8 major (27.6%) complications. A blood transfusion was required in 11 (37.9%) patients. There were 2 (6.9%) deaths. A delay to surgery of more than 2 days was associated with increased risk of major complication (p< 0.03). ASA, Age, Grade of surgeon or Cement not associated with major complications. Our results are inferior to those in the literature. We have identified potential causes; mainly a delay to surgery increasing risk of major complication. In keeping with the current guidelines we recommend that local pathways are instigated to ensure THRs for trauma may be preformed in a timely fashion


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 204 - 204
1 Jul 2014
Drynda A Singh G Buchhorn G Kliche S Feuerstein B Ruetschi M Lohmann C
Full Access

Summary Statement. CXCR4 gene and protein expression is regulated in a dose and time-dependent manner by metallic wear debris but not polyethylene wear debris in vitro and in vivo. Introduction. Progressive osteolysis leading to aseptic loosening among metal-on-metal (MoM) total hip arthroplasties (THA's), and adverse reactions to metallic debris (ARMD) are increasing causes for concern among existing patients who have been implanted with MoM hip replacements. Close surveillance of these patients is necessary and difficulties lie in early detection as well as differentiating low-grade infection from ARMD in the early stages. Several inflammatory markers have been investigated in this context, but to date, none is specific with regards to the offending material. In earlier studies, it has been shown that osteoblastic phenotypes and differentiation are regulated by different types of wear particles. Methods. In vitro experiments were performed using MG63 and SaOs-2 osteoblast-like cells co-cultured with increasing concentrations of metallic (Co-35Ni-20Cr-10Mo and Co-28Cr-6Mo) and polyethylene (UHMWPE-GUR1020) particles simulating periprosthetic wear debris. Real-time Polymerase Chain Reaction (RT-PCR) and Western Blotting were used to quantify gene and protein expression of CXCR4. The expression of TNF-a and the effects of AMD3100 on both CXCR4 and TNF-a expression among these cells was also investigated. Immunohistochemical techniques were used to investigate the in-vivo expression of CXCR4 in retrieval tissues obtained from 2 cohorts of failed metal-on-metal and ceramic-on-polyethylene THA's. Results. In-vitro RT-PCR and experiments demonstrated a dose-dependent increase in CXCR4 mRNA (7.5 fold for MG63 and 4.0 fold for SaOs-2 cells) among cells co-cultured with metal alloy particles. Western blotting also showed a time-dependent increase in protein expression of CXCR4. No regulatory effects on CXCR4 gene expression were seen among cells co-cultured with UHMWPE particles. The attempted blockade of CXCR4 by it's known competitive receptor agonist AMD3100 (bicyclam) led to a significant inhibition of metal particle induced TNF-a mRNA expression. In-vivo immunohistochemical data from the 2 cohorts of patients with failed THA's showed CXCR4 positivity among 83% of patients with metal-on-metal hip replacements but none among ceramic-on-polyethylene hip replacements. Discussion/Conclusion. CXCR4, the chemokine receptor for the chemokine SDF-1 (stromal cell derived factor-1), has been shown to play a pivotal role in bone metastasis, inflammatory and autoimmune conditions but has not been investigated in the context of periprosthetic osteolysis in failed joint replacements. Our in-vivo and in-vitro findings collectively suggest that the CXCR4 chemokine is specifically upregulated in a dose and time-dependent manner in the presence of metallic (cobalt-chrome) wear debris but not by polyethylene wear debris. The CXCR4 chemokine receptor may be a selective and specific biomarker for progressive osteolysis seen in failed MoM hip replacements and this phenomenon could potentially have a translational effect on the practice of orthopaedic surgery. Further research is needed to evaluate the interactions of CXCR4 with osteoclast activation and signalling pathways


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 436 - 439
1 Apr 2003
Nogler M Lass-Flörl C Wimmer C Mayr E Bach C Ogon M

Instruments used in surgery which rotate or vibrate at a high frequency can produce potentially contaminated aerosols. Such tools are in use in cemented hip revision arthroplasties. We aimed to measure the extent of the environmental and body contamination caused by an ultrasound device and a high-speed cutter. On a human cadaver we carried out a complete surgical procedure including draping and simulated blood flow contaminated with Staphylococcus aureus (ATCC 12600). After cemented total hip arthroplasty, we undertook repeated extractions of cement using either an ultrasound device or a high-speed cutter. Surveillance cultures detected any environmental and body contamination of the surgical team. Environmental contamination was present in an area of 6 x 8 m for both devices. The concentration of contamination was lower for the ultrasound device. Both the ultrasound and the high-speed cutter contaminated all members of the surgical team. The devices tested produced aerosols which covered the whole operating theatre and all personnel present during the procedure. In contaminated and infected patients, infectious agents may be present in these aerosols. We therefore recommend the introduction of effective measures to control infection and thorough disinfection of the operating theatre after such procedures


Bone & Joint 360
Vol. 6, Issue 6 | Pages 41 - 43
1 Dec 2017
Foy MA


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1655 - 1659
1 Dec 2007
Anwar HA Aldam CH Visuvanathan S Hart AJ

The biological significance of cobalt-chromium wear particles from metal-on-metal hip replacements may be different to the effects of the constituent metal ions in solution. Bacteria may be able to discriminate between particulate and ionic forms of these metals because of a transmembrane nickel/cobalt-permease. It is not known whether wear particles are bacteriocidal.

We compared the doubling time of coagulase negative staphylococcus, Staphylococcus aureus and methicillin resistant S. aureus when cultured in either wear particles from a metal-on-metal hip simulator, wear particles from a metal-on-polyethylene hip simulator, metal ions in solution or a control.

Doubling time halved in metal-on-metal (p = 0.003) and metal-on-polyethylene (p = 0.131) particulate debris compared with the control.

Bacterial nickel/cobalt-transporters allow metal ions but not wear particles to cross bacterial membranes. This may be useful for testing the biological characteristics of different wear debris. This experiment also shows that metal-on-metal hip wear debris is not bacteriocidal.