Biomechanical stimuli have fundamental roles in the maintenance and remodeling of ligaments including collagen gene expressions. Mechanical
Introduction. Sheffield Children's Hospital specialises in limb lengthening for children. Soft tissue contracture and loss of range of motion at the knee and ankle are common complications. This review aims to look at therapeutic techniques used by the therapy team to manage these issues. Materials & Methods. A retrospective case review of therapy notes was performed of femoral and tibial lengthening's over the last 3 years. Included were children having long bone lengthening with an iIntramedullary nail, circular frame or mono-lateral rail. Patients excluded were any external fixators crossing the knee/ankle joints. Results. 20 tibial and 25 femoral lengthening's met the inclusion criteria. Pathologies included, complex fractures, limb deficiency, post septic necrosis and other congenital conditions leading to growth disturbance. All patients had issues with loss of motion at some point during the lengthening process. The knee and foot/ankle were equally affected. Numerous risk factors were identified across the cohort. Treatment provided included splinting, serial casting, bolt on shoes, exercise therapy, electrical muscle stimulation and passive
Introduction. Compartment syndrome can be a life changing consequence of injury to a limb. If not diagnosed and treated early it can lead to permanent disability. Neurovascular observations done on the ward by nursing staff, are often our early warning system to those developing compartment syndrome. But are these adequate for detecting the early signs of compartment syndrome? Our aim was to compare the quality and variability of charts across the UK major trauma network. Materials & Methods. All major trauma centres in England and Scotland were invited to supply a copy of the neurovascular chart routinely used. We assessed how such charts record relevant information. Specific primary data points included were pain scores, analgesia requirements, pain on passive
The etiology of the flexion contracture is related to recurrent effusions present in a knee with end-stage degenerative joint disease secondary to the associated inflammatory process. These recurrent effusions cause increased pressure in the knee causing pain and discomfort. Patients will always seek a position of comfort, which is slight flexion. Flexion decreases the painful stimulus by reducing pressure in the knee and relaxing the posterior capsule. Unfortunately, this self-perpetuating process leads to a greater degree of contracture as the disease progresses. Furthermore, patients rarely maintain the knee in full extension. Even during the gait cycle the knee is slightly flexed. As their disease progresses, patients limit their ambulation and are more frequently in a seated position. Patients often report sleeping with a pillow under their knee or in the fetal position. All of these activities increase flexion contracture deformity. Patients with excessive deformity >40 degrees should be counseled regarding procedural complexity and that increasing constraint may be required. Patients are seen preoperatively by a physical therapist and given a pre-arthroplasty conditioning program. Patients with excessive flexion contracture are specifically instructed on
Introduction. Early hip OA may be attributed to smaller coverage of the femoral head leading to higher loads per unit area. We hypothesize that tight hamstrings may contribute to increased loads per unit area on the femoral head during gait. When a patient has tight hamstrings they cannot flex their pelvis in a normal fashion which may result in smaller coverage of the femoral head (Figure 1). This study aimed to determine if subjects with tight hamstrings can improve femoral head coverage during gait after a
Aims. Interest in soft tissue Radiostereometric Analysis (RSA) is rising. Previous authors have tried, with varying levels of success, to use this technique to analyse the intra-substance portion of anterior cruciate ligament (ACL) graft constructs. These methods were either prone to large amounts of marker migration, deemed unsuitable for in-vivo use or, where alternative markers such as stainless steel sutures were used, lost the inherent accuracy that made RSA an attractive tool in the first place. We describe a modification of tantalum marker balls that allows for a new method of secure fixation to soft tissue in order to accurately analyse
Roentgen stereophotogrammetric analysis (RSA) is the most accurate radiographic technique for the assessment of three-dimensional micromotion in joints. RSA has been used previously to study the kinematics of the anterior cruciate ligament (ACL)-deficient knee and to measure knee laxity after bone-tendon-bone (BTB) reconstructions. There is no published evidence on its use in assessing hamstring grafts in vivo, in comparing hamstring versus BTB reconstruction, or in-depth analyses of graft performance. The aim of this project was to use RSA to measure laxity in both BTB and hamstring reconstructions, and to attempt a detailed analysis of graft behaviour in both reconstructions, with particular attention to graft
Aim. Over the last 15 years there has been a series of publications reporting the beneficial effects of elbow arthrolysis, with considerable variation in operative technique and post-operative management. Many advocate the use of passive
The etiology of the flexion contracture is related to recurrent effusions present in a knee with end-stage degenerative joint disease secondary to the associated inflammatory process. These recurrent effusions cause increased pressure in the knee causing pain and discomfort. Patients will always seek a position of comfort, which is slight flexion. Flexion decreases the painful stimulus by reducing pressure in the knee and relaxing the posterior capsule. Unfortunately, this self-perpetuating process leads to a greater degree of contracture as the disease progresses. Furthermore, patients rarely maintain the knee in full extension. Even during the gait cycle the knee is slightly flexed. As their disease progresses, patients limit their ambulation and are more frequently in a seated position. Patients often report sleeping with a pillow under their knee or in the fetal position. All of these activities increase flexion contracture deformity. Patients with excessive deformity >40 degrees should be counseled regarding procedural complexity and that increasing constraint may be required. Patients are seen pre-operatively by a physical therapist and given a pre-arthroplasty conditioning program. Patients with excessive flexion contracture are specifically instructed on
Background. Calipered kinematically aligned (KA) total knee arthroplasty (TKA) restores the in vitro internal-external (I-E) rotation laxities at 0° and 90° of the native knee. Although increasing and decreasing the thickness of the insert in 1 mm increments loosens and tightens the flexion space, there are little data on how this might adversely affect the screw-home mechanism and I-E rotational laxity. The present study determined the differences in the I-E range of rotation and I-E positions at maximum extension and at 90° of flexion that result from the use of insert thicknesses that deviate ± 1mm in thickness from the implanted insert. Methods. 20 patients were treated with a calipered KA and a PCL retaining implant with a 1:1 medial ball-in-socket constraint and a non-constrained lateral flat articular insert surface. Verification checks, that are validated to restore native tibial compartment forces without release of healthy ligaments including the PCL, were used to select the optimal insert thickness. Trial inserts with thicknesses ranging from 10 to 13 mm were 3-D printed with medial goniometric markings that record rotation from 20° external to −20° internal with respect to a sagittal line laser marked on center of the medial condyle of the trial femoral component at maximum extension and 90° of flexion (Figure 1). Results. For all three inserts, the tibial component progressively internally rotated on the femoral component from maximum extension to maximum flexion. From maximum extension to 90° flexion the −21.7° range of internal rotation for the optimal insert thickness was greater than the −16° for the 1mm thinner insert (p < 0.000), and the −13.1° for the 1mm thicker insert (p < 0.000). At maximum extension, the mean insert position of 7° external for the optimal insert thickness was more external than the 4.5° for the 1mm thinner insert (p < 0.000), and the 3.5° for the 1mm thicker insert (p < 0.000) (Figure 2). At 90° the mean −14.7° internal insert position for the optimal insert thickness was more internal than the −11.5° for the 1mm thinner insert (p < 0.000), and the −9.5° for the 1mm thicker insert (p < 0.000) (Figure 3). Discussion and Conclusions. The insert goniometer is an inexpensive, simple, and sensitive instrument that measured the insert position of a medial ball-in-socket PCL retaining implant with a flat lateral insert implanted with calipered KA and showed the I-E rotation matched the pattern of the native knee's screw-home mechanism. Restoring the pre-arthritic native ligament laxities is the target, as the insert goniometer detected a 6° loss of internal rotation and a less external position of the insert at maximum extension and a less internal position at 90° when the healthy ligaments were
Introduction. Iliopsoas impingement is a well described cause of groin pain after direct anterior total hip arthroplasty (THA). We proposed to evaluate the incidence, natural history and response to treatment of iliopsoas impingement after direct anterior total hip arthroplasty. Methods. A retrospective chart review of 725 consecutive patients who underwent anterior approach total hip arthroplasty between 2009 and 2014 was conducted. All surgeries were performed by one of two surgeons. Patients were included if they underwent primary anterior approach THA and had a minimum of 2 years of follow up. Patients who had a posterior approach, revision surgery or had less than 2 years of follow up were excluded. Iliopsoas impingement was identified if patients reported groin pain at greater than 6 weeks of postoperative follow up and in association with pain with resisted seated hip flexion. The natural history and response to treatment was recorded for patients identified as having iliopsoas impingement. Results. 900 patients met inclusion criteria. Of these, 120 (13.4%) developed groin pain following direct anterior total hip arthroplasty. The average time of onset was at 21 months postoperatively. At 2 years postoperatively, 16% of patients had symptoms, whereas 84% had resolution. 28% of patients responded to structured physical therapy, 22% improved with home
An important goal of total knee replacement is deformity correction. Arthritic narrowing can be accompanied by a fixed shortening of the collateral ligament on the same side of the narrowing. There can also be ligamentous laxity that develops in the opposite compartment. Flexion contracture can develop with tightening of the posterior capsule. Successful total knee replacement requires proper bone resection along with gap balancing and balanced collateral ligament tensioning. Beware of correctable deformities, as the collateral ligament may have kept its resting length and therefore the knee becomes stable after the bone resections are made and the spacer block is inserted to test the stability of the knee in flexion and extension. In the varus knee, the MCL may be contracted. A medial release of the superficial medial collateral ligament may be necessary. This can be done by stripping the periosteal insertion of the MCL. A
Athletes involved in repetitive overhead shoulder rotation demonstrate increased external rotation and decreased internal rotation range of motion. Deficits in internal rotation have been linked to the development of shoulder pathology. The purpose of this study is to determine if a posterior shoulder
Following arthroscopic arthrolysis for frozen shoulder, steroid injections may become necessary to improve ongoing pain and facilitate
The detailed biomechanical mechanism of annulus fibrosus under abnormal loading is still ambiguous, especially at the micro and nano scales. This study aims to characterize the alterations of modulus at the nano scale of individual collagen fibrils in annulus fibrosus after in-situ immobilization, and the corresponding micro-biomechanics of annulus fibrosus. An immobilization model was used on the rat tail with an external fixation device. Twenty one fully grown 12-week-old male Sprague-Dawley rats were used in this study. The rats were assigned to one of three groups randomly. One group was selected to be the baseline control group with intact intervertebral discs (n=7). In the other two groups, the vertebrae were immobilized with an external fixation device that fixed four caudal vertebrae (C7-C10) for 4 and 8 weeks, respectively. Four K-wires were fixed in parallel using two aluminum alloy cuboids which do not compress or
Introduction. Revision for instability has supplanted revision for aseptic loosening and revision for osteolysis since the advent of improved polyethylene inserts with changes in both sterilization techniques and cross-linking. Having the ability to judiciously choose a higher level of constraint may be beneficial in complex primary total knee arthroplasty (TKA) scenarios which can not be balanced through traditional surgical methods. The purpose of this work was to investigate short term outcomes and survivorship in cases where a greater stabilizing insert was used with a posterior stabalizing (PS) femur to address instability in flexion or extension. Methods. Two high volume TKA centers retrospectively reviewed cases in which a greater stabilizer insert was used with a primary PS knee system. The studied insert had +/− 2 degrees of varus-valgus coronal restraint as opposed the standard with no coronal constraint. The study inserts had 7 degrees of transverse plane rotational freedom. The inserts were used when extension balance was not achieved despite the usual soft tissue releases and a thicker insert resulted in a flexion contracture statically during the procedure. This situation typically occurred in the following patient groups: valgus knees with medial collateral (MCL)
This study documents the gross and histologic structure of the infrapatellar plica, and fat pad, and adds to an earlier report to the COA. The important new findings are that the femoral attachment of the plica is an enthesis, and that the plica itself is. This study seeks to demonstrate that the structure of the fat pad (FP) and infrapatellar plica (IPP) is that of an enthesis organ. Twelve fresh frozen cadaver knees, each with an IPP, were dissected and the gross anatomic features recorded. The IPP and FP were harvested for study. Representative histologic sections were prepared on tissue fixed in 10% neutral buffered formalin, embedded in paraffin, cut at 4 microns on a rotatory microtome. Staining techniques included hematoxylin and eosin, Masson's trichrome, elastic stain and S100. Appropriate decalcification of sections of the femoral insertion of the IPP was performed. All sections were examined by light microscopy at low, medium and high power. IPP types included 8 separate, 1 split, 2 fenestrated, and one vertical septum. The origin of the IPP is a fibrous arc arising from the apex of the notch separate from the margin of the articular cartilage. This attachment site is the instant centreof rotation of the IPP and FP; they are thus not isometric. The central zone of the IPP consists of a mix of connective tissue types. Representative sections taken of the femoral attachment of the IPP display a transition zone between dense fibrillar collagen of the IPP, then fibrocartilage and cortical bone similar to a ligament attachment site or enthesis. The central plica histology is composed predominantly of dense regular connective tissue with variable clear space between the collagen bundles, and is thus ligamentous. There is abundant elastase staining throughout, as well as crimping of the collagen suggesting capacity for
Valgus deformity is less common than varus. There is an associated bone deformity in many cases – dysplasia of the lateral femoral condyle. There are also soft tissue deformities, including tightness of the lateral soft tissues, and
Chronic extensor mechanism insufficiency around TKA is a very challenging pathology to treat. An insufficient extensor mechanism negatively affects implant survival and patient outcomes. There are several risk factors for extensor mechanism disruption and the surgeon should be aware and avoid these problems in the perioperative period. In appropriately selected patients, reconstruction of the extensor mechanism is a valid option. Whole extensor mechanism and Achilles tendon allograft reconstruction of the deficient extensor mechanism have been proposed with good early published results. These reconstructions, however, are expensive and with time may
During the therapy of infected pseudarthrosis and arthrodesis in which multiple autologous bone grafts did not result in osseous consolidation and in delayed osseous healing of transport