Advertisement for orthosearch.org.uk
Results 1 - 20 of 60
Results per page:
Bone & Joint Open
Vol. 2, Issue 6 | Pages 443 - 456
28 Jun 2021
Thompson JW Corbett J Bye D Jones A Tissingh EK Nolan J

Aims. The Exeter V40 cemented polished tapered stem system has demonstrated excellent long-term outcomes. This paper presents a systematic review of the existing literature and reports on a large case series comparing implant fractures between the Exeter V40 series; 125 mm and conventional length stem systems. Methods. A systematic literature search was performed adhering to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) criteria. In parallel, we performed a retrospective single centre study of Exeter V40 femoral stem prosthetic fractures between April 2003 and June 2020. Results. There are 25 reported cases of such prosthetic fractures confined to small case series and case reports within the literature. We report an additional 19 cases to the literature (mean age 66.3 years (SD 11.7); 12 (63%) females; BMI 32.9 kg/m. 2. (SD 5.9)). The mean time from index procedure to fracture was 7.8 years (SD 3.6; 2.5 to 16.3). Exeter V40 stem fracture incidence was 0.15% and 1.21% for primary and revision arthroplasty, respectively. Incidence was significantly higher in revision arthroplasty (p < 0.001) and 125 mm length stems compared to ≥ 150 mm length stems (1.25% vs 0.13%, respectively; p < 0.001). When comparing different stem length cohorts, 125 mm short-stems were associated with stem-body fractures (92% vs 29%; p = 0.0095), earlier time to fracture (6.2 years vs 11.0 years; p = 0.0018), younger patient age at time of fracture (62.7 years vs 72.6 years; p = 0.037), and female sex (75% vs 43%; p = 0.326). Conclusion. This complication remains rare, although we report a significantly higher incidence at up to 17 years follow-up than in the literature. Short 125 mm length Exeter V40 stems undoubtedly have a role in restoring anatomy and biomechanics in smaller femoral geometries, although the surgeon has to appreciate the higher risk of stem fracture and the associated predisposing factors which may necessitate particular attention to surgical technique and planning. Cite this article: Bone Jt Open 2021;2(6):443–456


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 5 - 5
1 Aug 2021
Thompson J Corbett J Bye D Jones A Tissingh E Nolan J
Full Access

The Exeter. ™. V40 cemented polished tapered stem system has demonstrated excellent long-term outcomes. This paper presents a systematic review of the existing literature and reports on a large case series comparing implant fractures between the Exeter V40 series; 125 mm and conventional length stem systems. A systematic literature search was performed adhering to PRISMA criteria. In parallel we performed a retrospective single centre study of Exeter. ™. V40 femoral stem prosthetic fractures between April 2003– June 2020. There are 25 reported cases of such prosthetic fractures confined to small case series and case reports within the literature. We report an additional 19 cases to the literature (mean age 66.3 ± 11.7 years; 12 female [63%]; body mass index 32.9 ± 5.9 kg/m. 2. ). The mean time from index procedure to fracture was 7.8 years (2.5–16.3, ±3.6). Exeter V40 stem fracture incidence was 0.27%. Incidence was significantly higher in 125 mm length stems compared to ≥150 mm length stems (1.26% vs 0.13%, respectively, p <0.001) and revision arthroplasty (1.209% vs 0.149%, p <0.001). When comparing different stem length cohorts, 125-mm short-stem were associated with stem body fractures (92% vs 29%, p = 0.0095), earlier time to fracture (6.2 vs 11.0 years, p = 0.0018), younger patient age at time of fracture (62.7 vs 72.6 years old, p = 0.037) and female sex (75% vs 43%, p = 0.33). This case series in conjunction with the systematic review provides evidence stem morphology plays a role in femoral implant fracture. This complication remains rare, although we report a significantly higher incidence at up to 17 years follow-up than in the literature. As femoral geometries remain the same, increasing BMIs in THR patients should raise concern. Short 125 mm length Exeter V40 stems undoubtedly have a role in restoring anatomy and biomechanics in smaller femoral geometries, although the surgeon has to appreciate the higher risk of stem fracture and the associated predisposing factors which may necessitate meticulous surgical technique and planning


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 47 - 47
23 Jun 2023
Garbuz DS
Full Access

The purpose of this study was to determine long-term survival free from all-cause revision and stem-related failure, as well as radiographic and functional outcomes of the ZMR stem in revision THA. We retrospectively identified all patients in our institutional database who underwent revision THA using the ZMR Revision Hip system from the year 2000 to 2007 (minimum two-year follow-up). Of the 112 ZMR hips (110 patients) identified, a total of 106 hips (104 patients) met inclusion criteria. The mean study follow-up 13.9 years (range 2–22). Indications for index ZMR revision included aseptic loosening (72.1%), periprosthetic joint infection (17.3%), periprosthetic fracture (9.6%), and stem fracture (1.0%). Kaplan-Meier analysis was used to determine the all-cause and stem-related failure revision-free survival. Validated patient reported outcomes were collected and available radiographs were reviewed to determine implant stability. A total of 17 hips (16.0%) underwent a re-revision of any component. The indications for re-revision were stem failure (35.3%), infection (29.4%), instability (29.4%), and aseptic loosening of the acetabular component (5.9%). The five- and 15-year all-cause survivorship was 89.5% (95% CI 86.5–92.5) and 83.0% (95% CI 79.2–86.8), respectively. There were six re-revisions for stem failure (5.7%); five for stem fracture and one for aseptic loosening. The average time to stem failure was 4.6 years (range 1.3–8.2). The five- and 15-year survivorship free from stem-related failure was 97.2% (95% CI 95.6–98.8) and 93.9% (95% CI 91.5–96.3), respectively. At final follow-up the mean Oxford hip score was 36.9 and all surviving ZMR stems were well fixed on radiographs. Femoral revision with the ZMR stem offers satisfactory long-term survivorship and promising clinical outcomes. Although uncommon, stem fracture was the most common reason for stem-related failure


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 55 - 55
19 Aug 2024
Morlock M Wu Y Grimberg A Günther K Michel M Perka C
Full Access

Implant fracture of modular revision stems is a major complication after total hip arthroplasty revision (rTHA). Studies looking at specific modular designs report fracture rates of 0.3% to 0.66% whereas fractures of monobloc designs are only reported anecdotally. It is unclear whether the overall re-revision rate of modular designs is higher and if, whether stem fractures or other revision reasons are responsible for this elevation. All revisions within 5 years after implantation of a revision stems (n. 0. =13,900; n. 5. =2506) were analysed using Cox regression with design (modular: n=17, monobloc: n=27), BMI, Sex and Elixhauser Score as independent variables. One stage and two stage revisions were analysed separately (1-stage: modular n= 7,102; monobloc n= 4,542; 2-stage: 1,551 / 704). The revision volume of the hospitals was also considered (low: <20 revisions, medium: 21–50 revisions, high: >50 revisions). For the 1-stage revisions, the re-revision risk after 4 years was 14,3% [13.2%, 15.5%] for monobloc and 17.4% [16.40%, 18.40%] for modular stems (p< 0.001). Stem fracture was the reason for re-revision in 2.4% of the modular (fracture rate 0.42%) and 0.6% of the monobloc revisions. The difference in re-revision rates between the designs was mainly due to differences in dislocation and stem loosening. For the 2-stage revisions, the revision risks for either design were similar (21.7% [18,5%, 25.4%] vs. 23.0% [20.8%, 25.4%]; p=0.05). Patient characteristics influenced the comparison between the two designs in the 1-stage group but very little in the 2-stage group. Modular revision stem fractures only contribute very minor to re-revision risk. In 2-stage revisions, no difference in overall re-revision rates between designs was observed. This might indicate that the differences observed for 1-stage procedures are due to differences between the patient cohorts, not reflected by the parameters available or surgeon choice


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 151 - 157
1 Feb 2024
Dreyer L Bader C Flörkemeier T Wagner M

Aims. The risk of mechanical failure of modular revision hip stems is frequently mentioned in the literature, but little is currently known about the actual clinical failure rates of this type of prosthesis. The current retrospective long-term analysis examines the distal and modular failure patterns of the Prevision hip stem from 18 years of clinical use. A design improvement of the modular taper was introduced in 2008, and the data could also be used to compare the original and the current design of the modular connection. Methods. We performed an analysis of the Prevision modular hip stem using the manufacturer’s vigilance database and investigated different mechanical failure patterns of the hip stem from January 2004 to December 2022. Results. Two mechanical failure patterns were identified: fractures in the area of the distal fluted profile (distal stem fracture) and failure of the modular taper (modular fracture). A failure rate of 0.07% was observed for distal stem fracture, and modular fracture rates of 1.74% for the original and 0.013% for the current taper design. Conclusion. A low risk of mechanical failure for both fracture types was observed compared to other known complications in revision hip arthroplasty. In addition, the data show that a design change did significantly reduce the risk of a modular fracture. Cite this article: Bone Joint J 2024;106-B(2):151–157


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 49 - 49
19 Aug 2024
Beverland D Wong ML Robinson M Cassidy R Lamb J Diamond O
Full Access

A: - determine the incidence of intraoperative periprosthetic femoral fracture (PFF). B: - determine the incidence of, and the reoperation rate for postoperative PFF. When using either CC or PTS femoral components. Retrospective review of a consecutive series of 11,018 THAs over a ten-year period. All PFFs were identified using regional radiograph archiving and electronic care systems. Of the 11,018 THAs 4,952 were CC and 6,066 were PTS. Between groups, age, sex, and BMI did not differ. A: - 55 (0.5%) had an intraoperative PFF. 44 CC and 11 PTS (p<0.001). 3 patients in each group had a femoral shaft fracture, remaining fractures were either the calcar (20 CC and 2 group) or the greater trochanter (11 CC and 6 PTS). B: - 91(0.8%) sustained a postoperative PFF. Of those 15 were managed conservatively, 15 were revised and 61 (80.3%) had an ORIF. The CC group had both a lower overall rate of postoperative PFFs (0.7% (36/4,952) vs 0.9% (55/6,066); p = 0.341), and a lower rate of return to theatre (0.4% (22/4,952) vs 0.9% (54/6,066); p = 0.005). 1.3% of male PTS (36/2,674) had a reoperation compared to 0.3% of male CC (7/2,121) (p<0.001). With regard to stem fracture there were none in the Corail group and 5 in the Exeter group. Of these 2 were sub trunnion and 3 were basal neck. A: - There were significantly more intraoperative PFFs with CC 44 (0.8%) than PTS 11 (0.2%). However, the majority of fractures were either of the calcar or greater trochanter with no impact on early recovery or one year Oxford scores. B: - Male PTS were five times more likely to have a reoperation for postoperative PFF. Females had the same incidence of reoperation with either component type. There were 5 stem fractures in the Exeter group and none in the Corail. These results represent robust estimates, which are likely to be more accurate than revision only studies typically generated from registry data


Bone & Joint Open
Vol. 4, Issue 8 | Pages 551 - 558
1 Aug 2023
Thomas J Shichman I Ohanisian L Stoops TK Lawrence KW Ashkenazi I Watson DT Schwarzkopf R

Aims. United Classification System (UCS) B2 and B3 periprosthetic fractures in total hip arthroplasties (THAs) have been commonly managed with modular tapered stems. No study has evaluated the use of monoblock fluted tapered titanium stems for this indication. This study aimed to evaluate the effects of a monoblock stems on implant survivorship, postoperative outcomes, radiological outcomes, and osseointegration following treatment of THA UCS B2 and B3 periprosthetic fractures. Methods. A retrospective review was conducted of all patients who underwent revision THA (rTHA) for periprosthetic UCS B2 and B3 periprosthetic fracture who received a single design monoblock fluted tapered titanium stem at two large, tertiary care, academic hospitals. A total of 72 patients met inclusion and exclusion criteria (68 UCS B2, and four UCS B3 fractures). Primary outcomes of interest were radiological stem subsidence (> 5 mm), radiological osseointegration, and fracture union. Sub-analysis was also done for 46 patients with minimum one-year follow-up. Results. For the total cohort, stem osseointegration, fracture union, and stem subsidence were 98.6%, 98.6%, and 6.9%, respectively, at latest follow-up (mean follow-up 27.0 months (SD 22.4)). For patients with minimum one-year of follow-up, stem osseointegration, fracture union, and stem subsidence were 97.8%, 97.8%, and 6.5%, respectively. Conclusion. Monoblock fluted stems can be an acceptable modality for the management of UCS B2 periprosthetic fractures in rTHAs due to high rates of stem osseointegration and survival, and the low rates of stem subsidence, and revision. Further research on the use of this stem for UCS B3 periprosthetic fractures is warranted to determine if the same conclusion can be made for this fracture pattern. Cite this article: Bone Jt Open 2023;4(8):551–558


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 19 - 19
2 May 2024
Shaarani S Moriarty P Vles G Haddad F Konan S
Full Access

We had previously reported on early outcomes on a new fluted, titanium, monobloc stem with a three degree taper that has been designed for challenging femoral reconstruction in the setting of extensive bone loss. The aim of this study was to report its mid-term clinical and radiographic outcomes. This is a retrospective review of prospectively collected data carried out at a single institution between Jan 2017 and Dec 2019. 85 femoral revisions were performed using a new tapered, fluted, titanium, monobloc (TFTM) revision stem. Complications, clinical and radiographic data were obtained from medical records and a locally maintained database. Clinical outcomes were assessed using the Oxford Hip Score (OHS) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). All post-operative radiographs were analysed for subsidence, osteolysis and femoral cortical bone remodelling. Mean follow-up was 60 months (range 28–84 months). Subsidence of 1.2 mm was noted in one patient. No cases of clinically significant subsidence (10 mm) were observed. At final follow-up, a statistically significant improvement was noted in functional outcome scores. The mean OHS preoperatively and at final follow-up were 24 (SD 13) and 42 (SD15). p = 0.04 mean difference 18 (95% CI 15–22). The mean WOMAC scores preoperatively and at final follow-up were 62 (SD23) and 88 (SD7) respectively (p < 0.001, mean difference 26; 95% CI 21–34). No stem fractures were noted within the follow-up period. Two patients had revision of the stem's one for infection and another for persistent pain. Positive mid-term clinical and radiological outcomes have been observed with this tapered, fluted, titanium, monobloc stem. Based on these results, this implant may be considered as a viable option in the majority of uncemented femoral revisions


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 17 - 17
23 Jun 2023
Schreurs BW van Veghel MH van der Koelen RE Hannink G Rijnen WH
Full Access

Although data on uncemented short stems are available, studies on cemented short-stemmed THAs are limited. These cemented short stems may have inferior long-term outcomes and higher femoral component fracture rates. Hence, we examined the long-term follow-up of cemented short Exeter stems used in primary THA. Within the Exeter stem range, 7 stems have a stem length of 125 mm or less. These stems are often used in small patients, in young patients with a narrow femoral canal or patients with anatomical abnormalities. Based on our local database, we included 394 consecutive cemented stems used in primary THA (n=333 patients) with a stem length ≤125 mm implanted in our tertiary referral center between 1993 and December 2021. We used the Dutch Arthroplasty Registry (LROI) to complete and cross-check the data. Kaplan-Meier survival analyses were performed to determine 20-year survival rates with stem revision for any reason, for septic loosening, for aseptic loosening and for femoral component fracture as endpoints. The proportion of male patients was 21% (n=83). Median age at surgery was 42 years (interquartile range: 30–55). The main indication for primary THA was childhood hip diseases (51%). The 20-year stem survival rate of the short stem was 85.4% (95% CI: 73.9–92.0) for revision for any reason and 96.2% (95%CI: 90.5–98.5) for revision for septic loosening. No stems were revised for aseptic femoral loosening. However, there were 4 stem fractures at 6.6, 11.6, 16.5 and 18.2 years of follow-up. The stem survival with femoral component fracture as endpoint was 92.7% (CI: 78.5–97.6) at 20 years. Cemented short Exeter stems in primary THA show acceptable survival rates at long-term follow-up. Although femoral component fracture is a rare complication of a cemented short Exeter stem, orthopaedic surgeons should be aware of its incidence and possible risk factors


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 24 - 24
19 Aug 2024
Dagneaux L Abdel MP Sierra RJ Lewallen DG Trousdale RT Berry DJ
Full Access

Angular proximal femoral deformities increase the technical complexity of primary total hip arthroplasties (THAs). The goals were to determine the long-term implant survivorship, risk factors, complications, and clinical outcomes of contemporary primary THAs in this difficult cohort. Our institutional total joint registry was used to identify 119 primary THAs performed in 109 patients with an angular proximal femoral deformity between 1997 and 2017. The deformity was related to previous femoral osteotomy in 85%, and developmental or metabolic disorders in 15%. 53% had a predominantly varus angular deformity. The mean age was 44 years, mean BMI was 29 kg/m. 2. , and 59% were female. An uncemented metaphyseal fixation stem was used in 30%, an uncemented diaphyseal fixation stem in 28%, an uncemented modular body stem with metaphyseal fixation sleeve in 24%, and a cemented stem in 18%. Simultaneous corrective femoral osteotomy was performed in 18%. Kaplan-Meier survivorships and Harris hip scores were reported. Mean follow-up was 8 years. The 10-year survivorships free of femoral loosening, aseptic femoral revision, any revision, and any reoperation were 95%, 93%, 90% and 88%, respectively. Revisions occurred in 13 hips for: aseptic femoral component loosening (3), stem fracture (2), dislocation (2), aseptic acetabular loosening (2), polyethylene liner exchange (2), and infection (2). Preoperative varus angular deformities were associated with a higher risk of any revision (HR 10, p=0.03), and simultaneous osteotomies with a higher risk of any reoperation (HR 3.6, p=0.02). Mean Harris hip scores improved from 52 preoperatively to 82 at 10 years (p<0.001). In the largest series to date of primary THAs in patients with angular proximal femoral deformities, we found a good 10-year survivorship free from any revision. Varus angular deformities, particularly those treated with a simultaneous osteotomy due to the magnitude or location of the deformity, had a higher reoperation rate. Keywords: Proximal femoral deformity; dysplasia; femoral osteotomy; survivorship; revision. Level of evidence: Level III, comparative retrospective cohort


Full Access

Arthroplasty has consistently shown ‘beneficial and often dramatic improvements in quality of life'. In developed healthcare systems arthroplasty has evolved to minimised complications through evidence-based implant selection, rigorous infection control and high volume training. The Children's Surgical Centre has performed 256 THAs since 2007, We aim to assess the outcome of arthroplasty in a LMIC. Our primary outcome was all cause of re-operation and our secondary outcome was any complications not requiring return to theatre. A retrospective review of all consecutive THA since 2007 was conducted. Electronic and physical case notes were reviewed and basic demographics, indication for THA, risk factors for complications, implant combinations and complications were recorded. Statistical analysis was performed using MedCalc. A total of 256 THA were identified in 225 patients. The mean age was 43, with a M2:1F ratio. The most common pathologies were (1)AVN (44%), (2)OA (11%) and (3)DDH (11%). Revision rate was 13%. The mean time from implantation to revision was 2.8 years (0–9). The most common reasons for revision were (1)stem fracture (5.8%), (2)aseptic loosening (4.8%) and (3)infection (2.7%). Six different stems have been use over the time period. The best surviving were the Zimmer ML Taper and the UMA Muller stems. The UMA C-Stem was the worst performing which suffered 100% stem fracture. 109 complications were identified in 85 patients (33.2%). The three most common complications were (1)aseptic loosening (10.5%) (2)stem fracture (5.8%) and (3)dislocation (5.8%). Previous surgery (n=44) was found to be a significant risk for complications but not infection. OHS initially improved but began to decline after year 3. Patients present to CSC with neglected hip pathology, disability and significant pre-operative deformity. These patients benefit from THA and the initially high complication rates at CSC are declining suggesting the apex of the ‘learning curve' has passed. Cheap poorly manufactured implants continue to cause catastrophic failure


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 34 - 34
1 May 2018
Woodbridge A Wilson M Whitehouse S Hubble M
Full Access

Cement-in-cement femoral revision is a proven technique in revision total hip arthroplasty, with excellent results when using standard sized Exeter stems. The Exeter 44/00 125 mm short revision stem was introduced in 2004 to facilitate cement-in-cement revision. The stem is 25mm shorter and has a slimmer body to allow greater flexibility to adjust depth of insertion and version of the stem. However, it is not known if this change in stem length and size effects its longer term performance. We therefore reviewed the clinical outcome and survival of the Exeter 44/00 short stem used for cement-in-cement revision in our unit, with a minimum of 5 years follow up. 166 cases were performed between 2004 and 2010. 103 hips were available for 5 year clinical and radiological follow up, with 91 hips surviving to final review in 2017. At 5 years, 43 hips had died, 13 were revised and 7 were too frail to attend clinical review. The fate of all 166 hips were known and included in the survival analysis. Median clinical scores improved significantly. Sixteen hips required re-revision (infection 6, loose cup 3, periprosthetic fracture 3, instability 2, stem fracture with chronic infection 1 and pain 1). Kaplan-meier survival analysis revealed 100% survival for aseptic loosening, 96.8% survival for stem failure and 88.9% survival for all causes. This is the largest series with the longest follow up of the Exeter 44/00 short revision stem. The stem performs equally well as standard Exeter stems with regards to aseptic loosening. The single stem fracture occurred secondary to bone loss in chronic infection, highlighting the importance of providing adequate proximal support for the stem. Periprosthetic fracture occurred in 2.4% of this series of revision cases. Larger registry-based studies may provide additional information on the performance of this stem


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 504 - 510
1 May 2023
Evans JT Salar O Whitehouse SL Sayers A Whitehouse MR Wilton T Hubble MJW

Aims

The Exeter V40 femoral stem is the most implanted stem in the National Joint Registry (NJR) for primary total hip arthroplasty (THA). In 2004, the 44/00/125 stem was released for use in ‘cement-in-cement’ revision cases. It has, however, been used ‘off-label’ as a primary stem when patient anatomy requires a smaller stem with a 44 mm offset. We aimed to investigate survival of this implant in comparison to others in the range when used in primary THAs recorded in the NJR.

Methods

We analyzed 328,737 primary THAs using the Exeter V40 stem, comprising 34.3% of the 958,869 from the start of the NJR to December 2018. Our exposure was the stem, and the outcome was all-cause construct revision. We stratified analyses into four groups: constructs using the 44/00/125 stem, those using the 44/0/150 stem, those including a 35.5/125 stem, and constructs using any other Exeter V40 stem.


Bone & Joint Open
Vol. 4, Issue 8 | Pages 559 - 566
1 Aug 2023
Hillier DI Petrie MJ Harrison TP Salih S Gordon A Buckley SC Kerry RM Hamer A

Aims

The burden of revision total hip arthroplasty (rTHA) continues to grow. The surgery is complex and associated with significant costs. Regional rTHA networks have been proposed to improve outcomes and to reduce re-revisions, and therefore costs. The aim of this study was to accurately quantify the cost and reimbursement for a rTHA service, and to assess the financial impact of case complexity at a tertiary referral centre within the NHS.

Methods

A retrospective analysis of all revision hip procedures was performed at this centre over two consecutive financial years (2018 to 2020). Cases were classified according to the Revision Hip Complexity Classification (RHCC) and whether they were infected or non-infected. Patients with an American Society of Anesthesiologists (ASA) grade ≥ III or BMI ≥ 40 kg/m2 are considered “high risk” by the RHCC. Costs were calculated using the Patient Level Information and Costing System (PLICS), and remuneration based on Healthcare Resource Groups (HRG) data. The primary outcome was the financial difference between tariff and cost per patient episode.


Bone & Joint Research
Vol. 11, Issue 5 | Pages 270 - 277
6 May 2022
Takegami Y Seki T Osawa Y Imagama S

Aims

Periprosthetic hip fractures (PPFs) after total hip arthroplasty are difficult to treat. Therefore, it is important to identify modifiable risk factors such as stem selection to reduce the occurrence of PPFs. This study aimed to clarify differences in fracture torque, surface strain, and fracture type analysis between three different types of cemented stems.

Methods

We conducted biomechanical testing of bone analogues using six cemented stems of three different types: collarless polished tapered (CPT) stem, Versys Advocate (Versys) stem, and Charnley-Marcel-Kerboull (CMK) stem. Experienced surgeons implanted each of these types of stems into six bone analogues, and the analogues were compressed and internally rotated until failure. Torque to fracture and fracture type were recorded. We also measured surface strain distribution using triaxial rosettes.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_12 | Pages 52 - 52
1 Nov 2015
Marsh A Kennedy I Nisar A Patil S Meek R
Full Access

Introduction. Cement in cement revision with preservation of the original cement mantle has become an attractive and commonly practised technique in revision hip surgery. Since introducing this technique to our unit we have used two types of polished tapered stem. We report the clinical and radiological outcomes for cement in cement femoral revisions performed using these prostheses. Materials and Methods. All patients who underwent femoral cement in cement revision with a smooth tapered stem between 2005 –2013 were assessed. Data collected included indication for revision surgery and components used. All patients were followed up annually. Outcomes recorded were radiographic analysis, clinical outcome scores (Oxford Hip Score, WOMAC and SF-12) and complications, including requirement for further revision surgery. Median follow-up was 5 years (range 1 – 8 years). 116 revision procedures utilising cement in cement femoral revision were performed in the 8 year study period (68 females, 48 males, and mean age of 69 years). The femoral component was a C-stem AMT (Depuy) in 59 cases and Exeter stem (Stryker) in 57 cases. Results. Radiographic analysis demonstrated no progressive radiolucencies around the femoral component in any patient and no evidence of stem loosening at most recent review. Median Oxford Hip Score increased from 15 to 32, WOMAC from 22 to 38, and SF-12 from 25 to 32. Two patients had a further revision procedure for recurrent dislocation and 1 patient for infection. Two patients had a peri-prosthetic fracture at 4 years following initial revision surgery. There were 2 femoral stem fractures (occurring at 3 and 4 years post revision, both occurring in Exeter stems). Conclusion. Our results report cement in cement revision of the femoral component provides promising mid-term radiographic and clinical results. No femoral stems required revision for aseptic loosening. Stem fracture however occurred in 2 cases suggesting stem design is crucial for this technique


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 212 - 220
1 Feb 2022
Fishley WG Selvaratnam V Whitehouse SL Kassam AM Petheram TG

Aims

Femoral cement-in-cement revision is a well described technique to reduce morbidity and complications in hip revision surgery. Traditional techniques for septic revision of hip arthroplasty necessitate removal of all bone cement from the femur. In our two centres, we have been using a cement-in-cement technique, leaving the distal femoral bone cement in selected patients for septic hip revision surgery, both for single and the first of two-stage revision procedures. A prerequisite for adoption of this technique is that the surgeon considers the cement mantle to be intimately fixed to bone without an intervening membrane between cement and host bone. We aim to report our experience for this technique.

Methods

We have analyzed patients undergoing this cement-in-cement technique for femoral revision in infection, and present a consecutive series of 89 patients. Follow-up was undertaken at a mean of 56.5 months (24.0 to 134.7) for the surviving cases.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 72 - 72
1 Oct 2018
El-Husseiny M Masri BA Duncan CP Garbuz DS
Full Access

Background. Fully constrained liners are used to treat recurrent dislocations or patients at high risk after total hip replacements. However, they can cause significant morbidities including recurrent dislocations, infections, aseptic loosening and fractures. We examine long term results of 111 patients with tripolar constrained components to assess their redislocation and failure rate. Questions/purposes. The purpose of this study was to assess survivorship, complications and functional outcomes at a minimum 10 years after the constrained tripolar liners used in our institute. Methods. We retrospectively identified 111 patients who had 113 revision tripolar constrained liners between 1998 and 2008. Eighty-nine were revised due to recurrent dislocations, 11 for pseudotumor with deficient abductors, and 13 for periprosthetic infection with loss of soft tissue stabilizers. All patients had revision hip arthroplasty before the constrained liner was used: 13 after the first revision, 17 after the second, 38 after the third, and 45 had more than 3 revisions. We extracted demographics, implant data, rate of dislocations and incidence of other complications. Kaplan Meier curves were used to assess dislocation and failure for anything reason. WOMAC was used to assess quality of life. Results. At 10 years, the survival free of dislocation was 95.6% (95%CI 90– 98), and at 20 years to 90.6% (95% CI 81.0– 95.5). Eight patients (7.1%) had dislocations of their constrained liners: 1 patient had simultaneous periprosthetic infection identified at the time of open reduction, and 1 patient sustained stem fracture 3 months prior to the liner dislocation. At 10 years, the survival to any further surgery was 89.4% (95% CI 82–93.8), and at 20 years, this was 82.5 (95% CI 71.9–89.3). Five patients (4.4%) had deep infection: 4 of these had excision arthroplasty due to failure to control infection, while 1 patient was treated successfully with debridement, exchange of mobile components and intravenous antibiotics. Two patients (1.8%) had dissociated rings that required change of liner, ring and head. Two patients (1.8%) had periprosthetic femoral fractures that were treated by revision stems and exchange of constrained liners. The mean WOMAC functional and pain scores were 66.2 and 75.9 of 100, respectively. Conclusions. Constrained tripolar liners in our institute provided favourable results in the long term for recurrent dislocation hip arthroplasty with dysfunctional hip stabilizers. Infection in these patients can prove to be difficult to treat due to their poor soft tissue conditions from repeated surgeries. Comparing long term results from other types of constrained liners is essential to evaluate these salvage liners


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 48 - 48
1 Jan 2018
Schreurs B Colo E Schmitz M Rijnen W Gardeniers J
Full Access

Total hip arthroplasty (THA) in patients under 30 years remains a challenge. The long-term survival data are often disappointing. In our institution, we have always used cemented components in all patients under 30 years, combined with acetabular impaction bone grafting (IBG), if necessary. We reviewed 139 consecutive patients (180 hips) treated between 1986 to 2014. Mean age at time of surgery was 24 (13–30.0) years. Acetabular IBG was applied in 127 (71%) cases. AAOS cavitary defect was seen in 26 (14%) cases, a AAOS segmental defect in 51 (28%) and a combination in 17 (9%). The mean preoperative HHS improved from 47 (20–81) to 87 (28–100) at review. During follow-up 26 hips have been revised (23 cups and 11 stems). Indications for revision were aseptic loosening (n=15), septic loosening (n=5), recurrent dislocation (n=3), wear (n=1), and stem fracture (n=1). The 10-year Kaplan-Meier survival of any component with endpoint revision for any reason was 87% (95% CI 79%–92%) and for aseptic loosening 92% (84%–96%). The 15-year survival of any component with revision for any reason as the endpoint was 77% (65%–86%) and for aseptic loosening 84% (71%–92%). Cemented THA and, if needed with impaction bone grafting, in patients under 30 years provides satisfying long-term results up to 15 years after surgery. Probably this biological approach with IBG may facilitate the inevitable revisions in the future in these young patients because of more bone stock


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 206 - 211
1 Feb 2022
Bloch BV White JJE Matar HE Berber R Manktelow ARJ

Aims

Total hip arthroplasty (THA) is a very successful and cost-effective operation, yet debate continues about the optimum fixation philosophy in different age groups. The concept of the 'cementless paradox' and the UK 'Getting it Right First Time' initiative encourage increased use of cemented fixation due to purported lower revision rates, especially in elderly patients, and decreased cost.

Methods

In a high-volume, tertiary referral centre, we identified 10,112 THAs from a prospectively collected database, including 1,699 cemented THAs, 5,782 hybrid THAs, and 2,631 cementless THAs. The endpoint was revision for any reason. Secondary analysis included examination of implant survivorship in patients aged over 70 years, over 75 years, and over 80 years at primary THA.