Advertisement for orthosearch.org.uk
Results 1 - 6 of 6
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 18 - 18
1 Aug 2020
Goetz TJ Mwaturura T Li A
Full Access

Previous studies describing drill trajectory for single incision distal biceps tendon repair suggest aiming ulnar and distal (Lo et al). This suggests that the starting point of the drill would be anterior and radial to the anatomic insertion of the distal biceps tendon. Restoration of the anatomic footprint may be important for restoration of normal strength, especially as full supination is approached. To determine the safest drill trajectory for preventing injury to the posterior interosseous nerve (PIN) when repairing the distal biceps tendon to the ANATOMIC footprint through a single-incision anterior approach utilising cortical button fixation. Through an anterior approach in ten cadaveric specimens, three drill holes were made in the radial tuberosity from the centre of the anatomic footprint with the forearm fully supinated. Holes were made in a 30º distal, transverse and 30º proximal direction. Each hole was made by angling the trajectory from an anterior to posterior and ulnar to radial direction leaving adequate bone on the ulnar side to accommodate an eight-millimetre tunnel. Proximity of each drill trajectory to the PIN was determined by making a second incision on the dorsum of the proximal forearm. A K-wire was passed through each hole and the distance between the PIN and K-wire measured for each trajectory. The PIN was closest to the trajectory K-wires drilled 30° distally (mean distance 5.4 mm), contacting the K-wire in three cases. The transverse drill trajectory resulted in contact with the PIN in one case (mean distance 7.6 mm). The proximal drill trajectory appeared safest with no PIN contact (mean distance 13.3 mm). This was statistically significant with a Friedman statistic of 15.05 (p value of 0.00054). When drilling from the anatomic footprint of the distal biceps tendon the PIN is furthest from a drill trajectory aimed proximally. The drill is aimed radially to minimise blowing out the ulnar cortex of the radius. For any reader inquiries, please contact . vansurgdoc@gmail.com


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_20 | Pages 16 - 16
1 Dec 2017
Perets I Walsh JP Close MR Mu B Yuen LC Domb BG
Full Access

Background. Robotic assistance is being increasingly utilised in the surgical field in an effort to minimise human error. In this study, we report minimum two-year outcomes and complications for robotic-assisted total hip arthroplasty. Methods. Data were prospectively collected and retrospectively reviewed between June 2011 and April 2014. Inclusion criteria were primary robotic-assisted THAs treating idiopathic osteoarthritis with ≥ 2- year follow-up. Demographics, operating time, complications, 2-year outcome scores and satisfaction, and subsequent surgeries were recorded. Results. There were 181 cases eligible for inclusion, of which 162 (89.5%) had minimum 2-year follow- up. Eighty-nine females and 73 males were included. Forty-seven cases used an anterior approach and 115 used posterior approach. Mean age was 61.2 and mean BMI was 29.8. At latest follow-up, mean Visual Analog Scale for pain was 0.7, patient satisfaction was 9.3, Harris Hip Score was 91.1, and Forgotten Joint Score was 83.1. The mean time of surgery was 76.7 min. There were three (1.9%) greater trochanteric fractures and three (1.9%) calcar fractures. Postoperative complications included deep vein thrombosis (2 cases, 1.2%), femoral stem loosening (one case, 0.6%, treated with stem revision), infection (1 case, 0.6%, treated with single stage incision and drainage), aseptic hematoma (1 case, 0.6%, treated with single stage incision and drainage), and dropfoot (1 case, 0.6%). No leg length discrepancies (LLD) or dislocations were reported. Conclusion. Robotic-assisted THA is a safe procedure with favorable short-term outcomes. In particular, the excellent Forgotten Joint Score results suggest that this procedure effectively replicates the feeling of the native hip


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_8 | Pages 29 - 29
1 May 2014
Parvizi J
Full Access

Developmental dysplasia of the hip (DDH) is relatively a common condition that can lead to early arthritis of the hip. Although total hip arthroplasty is the surgical treatment of choice for these patients with end stage arthritis, some patients afflicted with DDH may present early. Acetabular osteotomy, in particular Bernese or periacetabular osteotomy (PAO as described by Professor Ganz and Jeff Mast back in 1980s) may be an option with patients with symptomatic DDH who have joint space available. PAO has many advantages. First, it is performed through a single incision (modified Smith Peterson approach) without breaching the abductor mechanism. The periacetabular fragment has, hence, excellent blood supply and avascular necrosis of the acetabular portion is not an issue. In addition, the osteotomy is so versatile allowing for great mobility of the fragment to obtain coverage even in the worst of circumstances. The osteotomy does not affect the posterior column and hence allows for earlier weight bearing. Most joint preservation surgeons in North America and Europe prefer PAO to other types of osteotomy. The indications for PAO are a patient with symptomatic DDH who has good joint space and a congruent joint. The congruency of the joint is usually determined by the abduction views (obtained at 30 degrees abduction and neutral rotation). Although the joint space may be measured on plain radiographs, in recent years some centers have been utilising cross sectional imaging, such as dGEMERIC for evaluation of the articular cartilage, which has been shown to be a good predictor of outcome for PAO


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVI | Pages 14 - 14
1 Apr 2012
Chana G
Full Access

The purpose of this study was to evaluate early results of a new as yet not described minimal invasive posterior gluteus maximus splitting approach for total hip arthroplasty (THA) and also metal on metal hip resurfacing. A new minimal invasive gluteus maximus splitting posterior approach is described backed up with intra-operative videos. This single incision approach allowed THA to be carried out through an incision ranging from 5.5 cm. to 9 cm. and metal on metal (MOM) resurfacing through an incision ranging from 7.5 cm. to 10 cm. Intra-operative fluoroscopy is not needed. The patients were not selected according to body mass index (BMI). All patients are suitable for this approach except for severely obese patients. 30 patients underwent THA (both cemented and uncemented) and 20 underwent MOM resurfacing. Early results at average 6 months indicate low post-operative pain scores, low blood loss (less than 5% needing transfusion), early mobilisation and discharge from hospital. Patients also returned to normal activities early with excellent cosmetic results and high patient satisfaction scores. There were no complications. THA and MOM hip resurfacing can safely be done through a minimally invasive gluteus maximus splitting approach with excellent early results without any complication


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 149 - 149
1 May 2012
C. K M. L J. M
Full Access

Background. The transverse skin incision for anterior cervical spine surgery is not extensile, thus it must be made at the accurate level. The use of palpable bony landmarks is unreliable due to anatomical variations and pre-operative fluoroscopy to identify the level takes up operating room time, increases the radiation dose to the patient and increases the overall cost of the operation. Objective. To describe a simple, fast and inexpensive method of accurate transverse skin incision placement for anterior cervical spine surgery and to report on its use in 54 consecutive adult patients. Patients and Methods. In each case a ratio was recorded on the lateral cervical spine radiograph based on the distance between the clavicle and mandible and the operative level; this was then applied to measurements on the patient's neck. Results. Procedures performed consisted of a mix of discectomy and fusion, disc replacement and combinations of both. The operative level ranged from C2-C3 to C7-T1, the most common being C5-C6. Twenty-three patients had a single-level, 26 a two level and 5 a three level procedure; all cases were performed through one single transverse incision. Conclusion. We describe the highly successful use of a straightforward method for accurate level transverse skin incision placement for cervical spine surgery In no case was it necessary to radically extend or to make a separate incision. There were no cases where the wrong level was operated on


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 58 - 58
1 Sep 2012
Young A Evans S
Full Access

This study was undertaken to assess for equivalence or superiority in tendon reconstruction techniques. This is an in vitro analysis of several, different, reconstruction techniques for chronic Achilles tendon ruptures. The surgical techniques have been borne out of surgical preference rather than biomechanical principles with little published research into their comparability. Surgical preferences are a result of the supposed benefits of reduced operative time, single operative incision and decreased morbidity. An animal model, after human cadaveric tissue dissection to guide the specimen construction, was used to compare the different techniques using bovine bone and tendon and tested using a material testing machine. Ultimate load to failure was recorded for all specimens and statistical analysis of the results was undertaken. A statistically significant difference was shown between all the techniques by analysis of variance. This will guide clinical application of these techniques. The use of bone tunnels, through which the flexor hallucis longus tendon can be passed, were found to be biomechanically superior, with regard to ultimate load to failure, to either bone anchors or end-to-end tendon suture techniques. Interference screws were found to have a large range in their ultimate load suggesting a lack of consistency in the results. The mean of the bone tunnel group (482.8N, SD 83.6N) is significantly (p < 0.01) higher than the mean of the bone anchor group (180.2N, SD 19.3N), which is, in turn, significantly (p < 0.01) higher than the mean of the Bunnell group (73.7N, SD 20.9N). This study is larger than any previous study found in the literature with regard to number of study groups and allows the techniques to be compared side by side