Alumina–alumina bearings are among the most resistant
to wear in total hip replacement. Examination of their surfaces
is one way of comparing damage caused by wear of hip joints simulated We found that long-term alumina wear in association with a loose
acetabular component could be categorised into three groups. Of
20 specimens, four had ‘low wear’, eight ‘crescent wear’ and eight
‘severe wear’, which was characterised by a change in the physical
shape of the bearing and a loss of volume. This suggests that the
wear in alumina–alumina bearings in association with a loose acetabular
component may be variable in pattern, and may explain, in part,
why the wear of a ceramic head
Aims. The aim of the study was to compare two methods of calculating pelvic incidence (PI) and pelvic tilt (PT), either by using the femoral heads or acetabular domes to determine the bicoxofemoral axis, in patients with unilateral or bilateral primary hip osteoarthritis (OA). Methods. PI and PT were measured on standing lateral radiographs of the spine in two groups: 50 patients with unilateral (Group I) and 50 patients with bilateral hip OA (Group II), using the femoral heads or acetabular domes to define the bicoxofemoral axis. Agreement between the methods was determined by intraclass correlation coefficient (ICC) and the standard error of measurement (SEm). The intraobserver reproducibility and interobserver reliability of the two methods were analyzed on 31 radiographs in both groups to calculate ICC and
The aims of this study were to: 1) report on a cohort of skeletally mature patients with native hip and knee septic arthritis over a 14-year period; 2) to determine the rate of joint failure in patients who had experienced an episode of hip or knee septic arthritis; and 3) to assess the outcome following septic arthritis relative to the infecting organism, whether those patients infected by All microbiological samples from joint aspirations between March 2000 and December 2014 at our institution were reviewed in order to identify cases of culture-proven septic arthritis. Cases in children (aged < 16 years) and prosthetic joints were excluded. Data were abstracted on age at diagnosis, sex, joint affected (hip or knee), type of organisms isolated, cause of septic arthritis, comorbidities within the Charlson Comorbidity Index (CCI), details of treatment, and outcome.Aims
Methods
Abstract. Objectives. In the human knee, the cells of the articular cartilage (AC) and subchondral bone (SB) communicate via the secretion of biochemical factors. Chondrocyte-based AC repair strategies, such as articular chondrocyte implantation, are widely used but there has been little investigation into the communication between the native SB cells and the transplanted chondrocytes. We hypothesise that this communication depends on the health state of the SB and could influence the composition and quality of the repair cartilage. Methods. An indirect co-culture model was developed using transwell inserts, representing a chondrocyte/scaffold-construct for repair of AC defects adjoining SB with varying degrees of degeneration. Donor-matched populations of human bone-marrow derived mesenchymal stromal cells (BM-MSCs) were isolated from the macroscopically and histologically best and worst osteochondral tissue, representing “healthy” and “unhealthy” SB. The BM-MSCs were co-cultured with normal chondrocytes suspended in agarose, with the two cell types separated by a porous membrane. After 0, 7, 14 and 21 days, chondrocyte-agarose scaffolds were assessed by gene expression and biochemical analyses. Results. Matched healthy and unhealthy BM-MSCs from five patients undergoing knee arthroplasty (2 male, 3 female; 72.8±2.2. SD. years-old) were used, together with normal chondrocytes from a healthy patient (male; 24 years-old). At day 21, there was significantly more glycosaminoglycan per chondrocyte in the scaffolds co-cultured with healthy BM-MSCs (4.37×10. −4. μg/cell±2.69×10. −5.
Adult male C57Bl/6 mice (n = 75) were randomized into three groups to receive 1.0 to 1.4 × 107 colony-forming units (CFUs)/ml of 8325-4, DU1090, or saline into the right stifle joint. Chondrocyte death was assessed by confocal microscopy. Histological changes to inoculated joints were graded for inflammatory responses along with gait, weight changes, and limb swelling.Aims
Methods
Compartment syndrome, a devastating consequence
of limb trauma, is characterised by severe tissue injury and microvascular
perfusion deficits. We hypothesised that leucopenia might provide
significant protection against microvascular dysfunction and preserve
tissue viability. Using our clinically relevant rat model of compartment syndrome,
microvascular perfusion and tissue injury were directly visualised
by intravital video microscopy in leucopenic animals. We found that
while the tissue perfusion was similar in both groups (38.8% (standard
error of the mean (. sem). 7.1). , 36.4. % (.
Aim. Fungal periprosthetic joint infections are difficult to treat and often associated with a limited outcome for patients. Candida species account for approximately 90% of all fungal infections. In vivo biofilm models play major role to study biofilm development, morphology, and regulatory molecules for bacteria. However, in vivo modeling of biofilm-associated fungi models are very rare. Furthermore, due to ethical restrictions, mammalian models are replaced with other alternative models in basic research. Recently, we have developed insect infection model G. mellonella larvae to study implant associated biofilm infections with bacteria. This model organism was not used for fungi biofilm infection yet. Thus, we aimed to establish G. mellonella as in vivo model to study fungal implant infections using Candida albicans as model organism and to test anti-fungal medication. Method. Titanium and Stainless steel K-wires were cut into small pieces with size of 4mm. For the infection process, implants were pre-incubated in specified fungal growth culture Candida albicans at 1×10. 7. CFU/ml for 30 min at 150 rpm shaking conditions. Later, these implants were washed with 10ml PBS and implanted in the larvae as mentioned. To analyze the susceptibility of the implant-associated fungal infections towards anti fungal compounds, the larvae were treated with amphotericin B, fluconazole and voriconazole after 24h of implantation. The effect of anti-fungal compounds was measured in terms of survival observation for 5 days and fungal load in larvae on 2. nd. day. To reveal the fungal biofilm formation on implant, the implants were removed on day 3 and processed for
Critical size bone defects deriving from large bone loss are an unmet clinical challenge1. To account for disadvantages with clinical treatments, researchers focus on designing biological substitutes, which mimic endogenous healing through osteogenic differentiation promotion. Some studies have however suggested that this notion fails to consider the full complexity of native bone with respect to the interplay between osteoclast and osteoblasts, thus leading to the regeneration of less functional tissue2. The objective of this research is to assess the ability of our laboratory's previously developed 6-Bromoindirubin-3’-Oxime (BIO) incorporated guanosine diphosphate crosslinked chitosan scaffold in promoting multilineage differentiation of myoblastic C2C12 cells and monocytes into osteoblasts and osteoclasts1, 3, 4. BIO addition has been previously demonstrated to promote osteogenic differentiation in cell cultures5, but implementation of a co-culture model here is expected to encourage crosstalk thus further supporting differentiation, as well as the secretion of regulatory molecules and cytokines2. Biocompatibility testing of both cell types is performed using AlamarBlue for metabolic activity, and nucleic acid staining for distribution. Osteoblastic differentiation is assessed through quantification of ALP and osteopontin secretion, as well as osteocalcin and mineralization staining. Differentiation into osteoclasts is verified using
Aims. To investigate the efficacy of ethylenediaminetetraacetic acid-normal saline (EDTA-NS) in dispersing biofilms and reducing bacterial infections. Methods. EDTA-NS solutions were irrigated at different durations (1, 5, 10, and 30 minutes) and concentrations (1, 2, 5, 10, and 50 mM) to disrupt Staphylococcus aureus biofilms on Matrigel-coated glass and two materials widely used in orthopaedic implants (Ti-6Al-4V and highly cross-linked polyethylene (HXLPE)). To assess the efficacy of biofilm dispersion, crystal violet staining biofilm assay and colony counting after sonification and culturing were performed. The results were further confirmed and visualized by confocal laser scanning microscopy (CLSM) and scanning electron microscopy (SEM). We then investigated the efficacies of EDTA-NS irrigation in vivo in rat and pig models of biofilm-associated infection. Results. When 10 mM or higher EDTA-NS concentrations were used for ten minutes, over 99% of S. aureus biofilm formed on all three types of materials was eradicated in terms of absorbance measured at 595 nm and colony-forming units (CFUs) after culturing. Consistently,
Aims. The purpose of this study was to explore a simple and effective method of preparing human acellular amniotic membrane (HAAM) scaffolds, and explore the effect of HAAM scaffolds with juvenile cartilage fragments (JCFs) on osteochondral defects. Methods. HAAM scaffolds were constructed via trypsinization from fresh human amniotic membrane (HAM). The characteristics of the HAAM scaffolds were evaluated by haematoxylin and eosin (H&E) staining, picrosirius red staining, type II collagen immunostaining, Fourier transform infrared spectroscopy (FTIR), and scanning electron microscopy (SEM). Human amniotic mesenchymal stem cells (hAMSCs) were isolated, and stemness was verified by multilineage differentiation. Then, third-generation (P3) hAMSCs were seeded on the HAAM scaffolds, and phalloidin staining and
Aims. This study investigated vancomycin-microbubbles (Vm-MBs) and meropenem (Mp)-MBs with ultrasound-targeted microbubble destruction (UTMD) to disrupt biofilms and improve bactericidal efficiency, providing a new and promising strategy for the treatment of device-related infections (DRIs). Methods. A film hydration method was used to prepare Vm-MBs and Mp-MBs and examine their characterization. Biofilms of methicillin-resistant Staphylococcus aureus (MRSA) and Escherichia coli were treated with different groups. Biofilm biomass differences were determined by staining. Thickness and bacterial viability were observed with confocal laser scanning microscope (CLSM). Colony counts were determined by plate-counting. Scanning electron microscopy (SEM) observed bacterial morphology. Results. The Vm-MBs and Mp-MBs met the experimental requirements. The biofilm biomass in the Vm, Vm-MBs, UTMD, and Vm-MBs + UTMD groups was significantly lower than in the control group. MRSA and E. coli biofilms were most notably damaged in the Vm-MBs + UTMD group and Mp-MBs + UTMD group, respectively, with mean 21.55% (SD 0.08) and 19.73% (SD 1.25) remaining in the biofilm biomass. Vm-MBs + UTMD significantly reduced biofilm thickness and bacterial viability (p = 0.005 and p < 0.0001, respectively). Mp-MBs + UTMD could significantly decrease biofilm thickness and bacterial viability (allp < 0.001). Plate-counting method showed that the numbers of MRSA and E. coli bacterial colonies were significantly lower in the Vm-MBs + UTMD group and the Mp, Mp-MBs, UTMD, Mp-MBs + UTMD groups compared to the control group (p = 0.031).
Aims. Compartment syndrome results from increased intra-compartmental
pressure (ICP) causing local tissue ischaemia and cell death, but
the systemic effects are not well described. We hypothesised that
compartment syndrome would have a profound effect not only on the affected
limb, but also on remote organs. Methods. Using a rat model of compartment syndrome, its systemic effects
on the viability of hepatocytes and on inflammation and circulation
were directly visualised using intravital video microscopy. Results. We found that hepatocellular injury was significantly higher
in the compartment syndrome group (192 PI-labelled cells/10. -1 . mm. 3. ,
standard error of the mean (.
Introduction and Objective. Type 2 diabetes mellitus (T2DM), and the often concurrent obesity, causes metabolic changes that affect many organs and tissues, including bone. Despite a normal or even higher bone mineral density (BMD), T2DM has often been associated with a higher fracture risk, indicating a compromised bone quality. In this work, we use a novel congenic leptin receptor-deficient BioBreeding Diabetes Resistant rat (BBDR.cg.lepr.cp) to investigate the impact of T2DM and obesity on bone morphology and architecture at the microscale. Materials and Methods. Two different anatomical locations, i.e., femur and cranium, were studied combining micro-computed X-ray tomography (micro-CT) with scanning electron microscopy (SEM). Micro-CT data were examined using advanced image analysis tools in three-dimensions (3D). Results. Both parietal bones and femurs were smaller, i.e., thinner and shorter, respectively, in diabetic animals compared to healthy controls. Image analysis of the sagittal suture revealed a reduced suture width and length in diabetic animals, suggesting an altered bone apposition rate. Histomorphometry analysis from micro-CT data highlighted differences in microstructure of both trabecular and cortical femur between diabetic and healthy rats. In particular, bone volume fraction (BV/TV) was lower in the T2DM group, while trabecular spacing (Tb.Sp) was increased, overall indicating a higher porosity in diabetic trabecular bone.
Osteoarthritis is a joint condition affecting an estimated eight million people in the UK. The kinematics of walking and the impact experienced are thought to play an important role in the initiation and progression of the disease. Previous studies have looked the effect of osteoarthritis on the kinematics of walking in a laboratory environment. This work is part of the Newcastle Thousand Families Study which has followed a cohort of 1142 members since birth in 1947. Optoelectronic gait analysis methods are unsuitable for this environment, so inertial measurement units are being used. This study focuses on the validation of a protocol using inertial sensors to assess gait in the clinical environment. The sensors measure orientation in three dimensions. Our hypothesis was that an attachment position that minimises the movement of the sensor relative to the segment during gait was more important than the proximity of the sensor to anatomical landmarks. The effect of sampling rate, fatty tissue movement and material type were also tested Seven sensors (Xsens, Netherlands) were attached to participants on top of the foot, on the tibial plateau, on the lateral surface of the femur 10cm proximal to the lateral epicondyle, and over the sacrum. Attachment is by Velcro straps over the top of clothing for the waist, thigh and shank sensors, and with double-sided hypoallergenic tape on the foot. Four calibration movements are performed followed by a walking trial of ten paces down a corridor at a self-selected speed. Data is recorded wirelessly at a sampling rate of 50Hz. The calibration movements and trials are repeated twice and the time taken is 20 minutes. Measurement of the joint angles in the sagittal plane was used to assess the effect of changing the sensor position, simulating fatty tissue movement, and variation of material type underneath the sensor. The foot and thigh sensors were displaced in the distal direction by up to 10cm, the shank and waist sensors were displaced in the proximal direction by 5cm. Material types of different elasticity were tested. Fatty tissue movement beneath the straps was simulated using hydration gel packs. Each attachment scenario was repeated five times on a single subject. A “normal” attachment scenario was used to establish a baseline for repeatability of hip, knee and ankle angle measurement (mean±standard deviation of 49±1.28°, 61.5±1.28° and 33.5±0.69° respectively). Repeatability is comparable to that reported for an opto-electronic system (45±1.8°, 63±1.9° and 36±1.5°). Displacement of the foot, shank and waist sensors had no effect on the repeatability. Displacement of the thigh sensor decreased the repeatability for the knee and hip joint angles (52±3.22° and 62.5±2.91°). As the thigh sensor moved closer to the knee the movement artefact experienced increased. Altering sampling rate and simulated fatty tissue did not decrease repeatability. Of the materials tested, denim had the greatest affect, decreasing hip and knee angle repeatability (50.0±2.04° and 61.0±1.75°). A sensor attachment position that minimises sensor movement relative to the segment has been shown to produce the greatest repeatability, irrespective of their proximity to bony landmarks. This is particularly true for the femur sensor.
Accidents, osteoporosis or cancer can cause severe bone damage requiring grafts to heal. All current grafting methods have disadvantages including scarcity and infection/rejection risks. An alternative is therefore needed. Hydroxyapatite/calcium carbonate (HA/CC) scaffolds mimic the mineral bone composition but lack growth factors present in auto- and allografts, limiting their osteoinductive capacity. We hypothesize that this will increase the osteogenicity and osteoinductivity of scaffolds through the presence of growth factors. The objectives of this study are to develop and mass-produce grafts with enhanced osteoinductive capacity. HA/CC scaffolds were cultured together with umbilical cord mesenchymal stem cells in bioreactors so that they adhere to the surface and deposit growth factors. Cells growing on the scaffolds are confirmed by Alamar blue assays,
ZrN-multilayer coating is clinically well established in total knee arthroplasty [1-3] and has demonstrated significant reduction in polyethylene wear and metal ion release [4,5]. The goal of our study was to analyze the biotribological behaviour of the ZrN-multilayer coating on a polished cobalt-chromium cemented hip stem. CoCr28Mo6 alloy hip stems with ZrN-multilayer coating (CoreHip®AS) were tested versus an un-coated version. In a worst-case-scenario the stems with ceramic heads have been tested in bovine serum in a severe cement interface debonding condition under a cyclic load of 3,875 N for 15 million cycles. After 1, 3, 5, 10 & 15 million cycles the surface texture was analysed by scanning-electron-microscopy (SEM) and energy-dispersive x-ray (EDX). Metal ion concentration of Co,Cr,Mo was measured by inductively coupled plasma mass spectroscopy (ICP-MS) after each test interval. Based on
Objective. To study the effect of hyaluronic acid (HA) on local anaesthetic
chondrotoxicity in vitro. Methods. Chondrocytes were harvested from bovine femoral condyle cartilage
and isolated using collagenase-containing media. At 24 hours after
seeding 15 000 cells per well onto a 96-well plate, chondrocytes
were treated with media (DMEM/F12 + ITS), PBS, 1:1 lidocaine (2%):PBS,
1:1 bupivacaine (0.5%):PBS, 1:1 lidocaine (2%):HA, 1:1 bupivacaine (0.
5%):HA, or 1:1 HA:PBS for one hour. Following treatment, groups
had conditions removed and 24-hour incubation. Cell viability was
assessed using PrestoBlue and confirmed visually using fluorescence
microscopy. Results. Media-treated groups had a mean of 1.55×10. 4. cells/well
(.
The aim of this study is to print 3D polycaprolactone (PCL) scaffolds at high and low temperature (HT/LT) combined with salt leaching to induced porosity/larger pore size and improve material degradation without compromising cellular activity of printed scaffolds. PCL solutions with sodium chloride (NaCl) particles either directly printed in LT or were casted, dried, and printed in HT followed by washing in deionized water (DI) to leach out the salt. Micro-Computed tomography (Micro-CT) and scanning electron microscope (SEM) were performed for morphological analysis. The effect of the porosity on the mechanical properties and degradation was evaluated by a tensile test and etching with NaOH, respectively. To evaluate cellular responses, human bone marrow-derived mesenchymal stem/stromal cells (hBMSCs) were cultured on the scaffolds and their viability, attachment, morphology, proliferation, and osteogenic differentiation were assessed. Micro-CT and
In 2020 almost 90% of femoral heads for total hip implants in Germany were made of ceramic. Nevertheless, the cellular interactions and abrasion mechanisms in vivo have not been fully understood until now. Metal transfer from the head-neck taper connection, occurring as smear or large-area deposit, negatively influences the surface quality of the articulating bearing. In order to prevent metal transfer, damage patterns of 40 Biolox delta ceramic retrievals with CoC and CoPE bearings were analysed. A classification of damage type and severity for each component (n=40) was done according to an established scoring system. To investigate the physical properties, the surface quality was measured using confocal microscopy, quantitative analysis of phase composition were performed by Raman spectroscopy and qualitative analysis of metal traces was done by scanning electron microscopy (SEM) with energy dispersive X-ray spectroscopy (EDX). The periprosthetic tissue was analysed for abrasion particles with
In 2021 the bone grafting market was worth €2.72 billion globally. As allograft bone has a limited supply and risk of disease transmission, the demand for synthetic grafting substitutes (BGS) continues to grow while allograft bone grafts steadily decrease. Synthetic BGS are low in mechanical strength and bioactivity, inspiring the development of novel grafting materials, a traditionally laborious and expensive process. Here a novel BGS derived from sustainably grown coral was evaluated. Coral-derived scaffolds are a natural calcium carbonate bio-ceramic, which induces osteogenesis in bone marrow mesenchymal stem cells (MSCs), the cells responsible for maintaining bone homeostasis and orchestrating fracture repair. By 3D printing MSCs in coral-laden bioinks we utilise high throughput (HT) fabrication and evaluation of osteogenesis, overcoming the limitations of traditional screening methods. MSC and coral-laden GelXA (CELLINK) bioinks were 3D printed in square bottom 96 well plates using a CELLINK BIO X printer with pneumatic adapter Samples were non-destructively monitored during the culture period, evaluating both the sample and the culture media for metabolism (PrestoBlue), cytotoxicity (lactose dehydrogenase (LDH)) and osteogenic differentiation (alkaline phosphatase (ALP)). Endpoint, destructive assays used included qRT-PCR and