Results 1 - 20 of 80
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_12 | Pages 20 - 20
10 Jun 2024
Somanathan A Sharp B Saedi F Loizou C Brown R Kendal A
Full Access

Introduction. Primary ankle arthroplasty (TAR) is increasingly used to treat end-stage ankle arthritis. Reported revision rates of TAR vary from 8.5% to 11.1% at 9 years. Revision surgery remains technically challenging with options ranging from simple joint debridement to tibio-talar-calcaneal fusion. The efficacy of these procedures remains unclear and there is no consensus on optimal revision options. Methods. A retrospective cohort study was performed of all patients undergoing surgery for a failed primary TAR at the Nuffield Orthopaedic Centre (2004–2021). TAR failure was determined by clinical assessment, serial radiographs and CT scans. Primary outcome measures included type and time of index surgery post TAR. Secondary outcomes included frequency of re-operations, post-operative complications, patient reported outcomes and union rate (for revision arthrodesis procedures). Results. 70 failed TARs in 69 patients (35M:34F, mean 65.7 years, s.d.=11.6) underwent re-operation a mean of 6.24 years (range 1–30) post primary. In total, 107 operations were performed including revision fusion (n=50), revision arthroplasty (n=14), bearing exchange (n=9) and joint clearance (n=9). The overall revision fusion union rate was 73.5% over a mean of 12.5 months (s.d.=7.6). 16/23 (69.6%) Tibio-Talo-Calcaneal and 9/12 (75%) ankle fusions (previous subtalar/triple fusion) using a hindfoot nail united over a mean 11.4 months (s.d.=6.0) and 15 months (s.d.=9.48) respectively. Only 64% of ankle fusions using screws alone united (mean=10.6 months, s.d.=8.14). The average post-operative MOXFQ score was 28.3 (s.d.=19.3). 73% said the operation improved their function and would recommend it to a friend/family member. Conclusion. Despite low post-operative MOXFQ scores, over 70% of patients were satisfied with re-operation for a failed TAR. Over 26% of all TAR revision fusions fail to unite with the highest non-union rates observed post ankle arthrodesis with screws alone (36.4%)


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 925 - 932
1 Jul 2020
Gaugler M Krähenbühl N Barg A Ruiz R Horn-Lang T Susdorf R Dutilh G Hintermann B

Aims. To assess the effect of age on clinical outcome and revision rates in patients who underwent total ankle arthroplasty (TAA) for end-stage ankle osteoarthritis (OA). Methods. A consecutive series of 811 ankles (789 patients) that underwent TAA between May 2003 and December 2013 were enrolled. The influence of age on clinical outcome, including the American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot score, and pain according to the visual analogue scale (VAS) was assessed. In addition, the risk for revision surgery that includes soft tissue procedures, periarticular arthrodeses/osteotomies, ankle joint debridement, and/or inlay exchange (defined as minor revision), as well as the risk for revision surgery necessitating the exchange of any of the metallic components or removal of implant followed by ankle/hindfoot fusion (defined as major revision) was calculated. Results. A significant improvement in the AOFAS hindfoot score and pain relief between the preoperative assessment and the last follow-up was evident. Age had a positive effect on pain relief. The risk for a minor or major revision was 28.7 % at the mean follow-up of 5.4 years and 11.0 % at a mean follow-up of 6.9 years respectively. The hazard of revision was not affected by age. Conclusion. The clinical outcome, as well as the probability for revision surgery following TAA, is comparable between younger and older patients. The overall revision rate of the Hintegra total ankle is comparable with other three component designs. TAA should no longer be reserved for low demand elderly patients, but should also be recognized as a viable option for active patients of younger age. Cite this article: Bone Joint J 2020;102-B(7):925–932


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_9 | Pages 15 - 15
16 May 2024
Egglestone A Kakwani R Murty A Townshend D
Full Access

Introduction

When ankle arthroplasty fails the options are revision to arthrodesis or revision to arthroplasty. We report early outcomes of revision procedures for failed total replacement.

Methods

Retrospective review of prospectively collected data including post-operative complications, union, survivorship and PROMS scores to compare revision to arthrodesis and revision to arthroplasty.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_19 | Pages 21 - 21
1 Nov 2016
Myerson M Li S Taghavi C Tracey T
Full Access

Background

Subtalar nonunion has a detrimental effect on patients' function, and pose a significant challenge for surgeons particularly in the setting of higher risk factors.

Methods

We retrospectively analyzed a consecutive series of 49 subtalar nonunions between October 2001 and July 2013. Patient records and radiographs were reviewed for specific patient demographics and comorbidities, subsequent treatments, revision fusion rate, use of bone graft, complications, and clinical outcome.


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1099 - 1107
1 Oct 2023
Henry JK Shaffrey I Wishman M Palma Munita J Zhu J Cody E Ellis S Deland J Demetracopoulos C

Aims. The Vantage Total Ankle System is a fourth-generation low-profile fixed-bearing implant that has been available since 2016. We aimed to describe our early experience with this implant. Methods. This is a single-centre retrospective review of patients who underwent primary total ankle arthroplasty (TAA) with a Vantage implant between November 2017 and February 2020, with a minimum of two years’ follow-up. Four surgeons contributed patients. The primary outcome was reoperation and revision rate of the Vantage implant at two years. Secondary outcomes included radiological alignment, peri-implant complications, and pre- and postoperative patient-reported outcomes. Results. There were 168 patients (171 ankles) included with a mean follow-up of 2.81 years (2 to 4.6) and mean age of 63.0 years (SD 9.4). Of the ten ankles with implant failure (5.8%), six had loosening of the tibial component. In the remaining four failed implants, one was due to periprosthetic joint infection (PJI), one was due to loosening of the talar component, and two were due to loosening of both the tibial and talar components. Seven patients underwent reoperation: irrigation and debridement for superficial infection (n = 4); bone grafting for cysts (n = 2); and open reduction internal fixation (n = 1). Asymptomatic peri-implant lucency/subsidence occurred in 20.1% of ankles, with the majority involving the tibial component (n = 25). There were statistically significant improvements in PROMs in all domains. Conclusion. Short-term results of this implant demonstrate early survival comparable to the reported survivorship of similar low-profile, non-stemmed implants. Radiological lucency occurred more commonly at the tibial component, and revisions occurred primarily due to loosening of the tibial component. Further research is needed to evaluate longer-term survivorship. Cite this article: Bone Joint J 2023;105-B(10):1099–1107


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1094 - 1098
1 Oct 2023
Jennison T Ukoumunne OC Lamb S Sharpe I Goldberg AJ

Aims. When a total ankle arthroplasty (TAA) fails, it can be converted to a fusion or a revision arthroplasty. Despite the increasing numbers of TAAs being undertaken, there is little information in the literature about the management of patients undergoing fusion following a failed TAA. The primary aim of this study was to analyze the survival of fusions following a failed TAA using a large dataset from the National Joint Registry (NJR). Methods. A data linkage study combined NJR and NHS Digital data. Failure of a TAA was defined as a fusion, revision to a further TAA, or amputation. Life tables and Kaplan-Meier graphs were used to record survival. Cox proportional hazards regression models were fitted to compare the rates of failure. Results. A total of 131 patients underwent fusion as a salvage procedure following TAA. Their mean age was 65.7 years (SD 10.6) and 73 (55.7%) were male. The mean follow-up was 47.5 months (SD 27.2). The mean time between TAA and fusion was 5.3 years (SD 2.7). Overall, 32 (24.4%) underwent reoperations other than revision and 29 (22.1%) failed. Of these 24 (18.3%) underwent revision of the fusion and five (3.8%) had a below-knee amputation. No patients underwent conversion to a further TAA. Failure usually occurred in the first three postoperative years with one-year survival of fusion being 96.0% (95% confidence interval (CI) 90.7 to 98.3) and three-year survival in 69 patients being 77.5% (95% CI 68.3 to 84.4). Conclusion. Salvage fusion after a failed TAA shows moderate rates of failure and reoperations. Nearly 25% of patients required revision within three years. This study is an extension of studies using the same methodology reporting the failure rates and risk factors for failure, which have recently been published, and also one reporting the outcome of revision TAA for a failed primary TAA, using the same methodology, which will shortly be published. Cite this article: Bone Joint J 2023;105-B(10):1094–1098


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 8 - 8
8 May 2024
Humphrey J Kanthasamy S Coughlin P Coll A Robinson A
Full Access

Aim. This retrospective case series reports the reoperation, major amputation, survival rates and mobility status in diabetic patients who underwent a trans-metatarsal amputation (TMA) managed within a multi-disciplinary diabetic foot care service. Methods and patients. Forty-one consecutive patients (37 men, 4 women) underwent a TMA between January 2008 to December 2017. They were retrospectively reviewed. The mean age at the time of surgery was 63 years (range 39 – 92). Results. Eighty-eight per cent (36/41) of the patients were followed-up. Four (11%) of the 36 patients required reoperation, including three major amputations (8%). All the patients requiring a reoperation were vasculopaths. The four-year patient survival rate following a TMA was 69% (25/36). Ninety-six per cent (21/22) of the surviving patients not requiring revision to a major amputation were fully mobile in bespoke orthoses, of whom a third required a stick. Conclusion. This study shows that transmetatarsal amputation in patients with diabetes, managed in a multi-disciplinary diabetic foot care service, is effective for limb salvage


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 4 - 4
8 May 2024
Nurm T Ramaskandhan J Nicolas A Siddique M
Full Access

Introduction. Total ankle arthroplasty (TAA) is an increasingly popular treatment option for patients with end-stage ankle arthritis. However, for most implant systems, failure rates of 10–20% have been reported within the first 10 years after primary TAA. Pain is the primary symptom that indicates failure of TAA but cause of it can be difficult to establish. Methods. All patients who underwent a primary TAA at our center were included in the study. The clinical outcomes were studied for patients requiring a further revision procedure following primary TAA. The reasons for revision surgery and outcomes of surgery were analyzed using appropriate inferential statistical tests. Results. Between 2007 and 2018, 42 primary TAA required revisions in 40 patients. There were 25 men (59.5%) and 15 women (35.7%) with mean age of 57.5 years the time of primary TAA. All patients had undergone primary procedure at a mean duration of 3.5 years previously (range: 3 months to 10 years). Of the total revision procedures, 12/40 (30%) of revisions were carried out due to malalignment, 10/42 (23.8%) due to loosening of the implants or bone subsidence, 5/42 procedures (11.9%) following infection, 4/42 (9.5%) due to polyethylene migration, 1/42 (2.3%) due to fracture and 1/42 (2.3%) due to Charcot arthropathy. In 9/42 (21.4%) cases, imaging showed no objective reason for pain. 50% of patients who underwent revision TAA reported 78.5% satisfaction with results of surgery at 2 years follow up post-operatively. Conclusion. Major reasons for revising primary TAR at our centre are mal-alignment, implant loosening / bone subsidence and suspicion of infection and pain. In-spite of undergoing a complex revision surgery, patients report 78.5% satisfaction from outcomes of surgery


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_9 | Pages 19 - 19
16 May 2024
Clifton L Kingman A Rushton P Murty A Kakwani R Coorsh J Townshend D
Full Access

Introduction. We report the functional outcome and survivorship of the Hintegra Total Ankle Replacement (TAR), in consecutive cases by multiple surgeons in a single UK institution. Between 2010–2014 the Hintegra TAR held 7.1% UK market share and surgeons should be aware of failure mechanisms. Methods. We conducted a retrospective review of prospectively collected data for 70 consecutive Hintegra TAR cases in a single institution between 2010–2014. Data collected included patient demographics, complications, reoperations, patient reported outcome measures (PROMS: AOS, MOX-FQ, pain VAS) and patient satisfaction. Results. The 70 patients (54 male/ 16 female) had an average age of 69 (range 48–84 years). Mean follow up was 76 months (range 60–04), 10 patients died during the follow up. Implant survivorship was 81.4% at most recent follow up. The commonest radiographic finding was periprosthetic cysts (n=28, 40%), size range (7–40mm), location of cysts: isolated talus (n=14), isolated tibia (n=6), mixed (n=8). 10 failed TARs were revised to Inbone TAR at a mean of 48 months (range 9–69). 3 Failed TARs were revised to arthrodesis (2 tibiotalar fusions, 1 hindfoot nail). 11 patients required reoperation with implant retention: 8 periprosthetic cyst debridement and grafting at a mean of 61 months (range 27–91), 1 lateral gutter debridement and 1 periprosthetic fracture ORIF. PROMS data was available for all patients. Overall patients showed marked improvement in functional outcome scores between pre-operative and final follow up questionnaires. Mean pre-op AOS: 62, MOX-FQ: 68 and pain VAS: 67.5 with mean final follow up scores of: AOS: 35, MOX-FQ: 36 and pain VAS: 30. Conclusion. Our experience demonstrates improved PROMS following ankle arthroplasty for patients with a mean follow up of 6.4 years. Implant survivorship is similar to other TAR studies. We have identified a high incidence of periprosthetic cysts and would recommend ongoing surveillance of these patients


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_11 | Pages 23 - 23
4 Jun 2024
Trowbridge S Lewis T Shehata R Lau B Lyle S Ray R
Full Access

Background. Hallux rigidus is a common condition characterised by first metatarsophalangeal joint (MTPJ) degeneration, pain and limited range of motion (ROM). The gold standard surgical treatment is arthrodesis, providing good pain relief but sacrifices ROM. Recently the Cartiva synthetic cartilage implant (SCI) has been utilised as an interpositional arthroplasty, aiming to reduce pain whilst preserving range of motion. Current evidence for Cartiva SCI is largely based on a single cohort with mixed outcomes. We sought to evaluate the clinical outcomes of Cartiva SCI compared to arthrodesis undertaken in our centre. Methods. Retrospective review of patients undergoing Cartiva SCI or arthrodesis for treating hallux rigidus was conducted. Preoperative arthritis was radiographically graded using the Vanore classification. Patient reported outcomes (PROMs) were assessed using EuroQol 5-dimension score (EQ-5D-5L) and Manchester-Oxford Foot Questionnaire (MOXFQ). Results. Between 2017 and 2020 there were 33 cases (17 Cartiva, 16 arthrodesis, mean age 59.0±9.9 years) with a mean follow up of 2.3 years. For the first MTPJ arthrodesis cohort, the MOXFQ domain scores were: Index 3.9±5.8, Walking/Standing 5.1±7.6, Pain 3.2±5.0, and Social Interaction 2.6±4.0. EQ-5D-5L Index score was 0.828±0.270 and the EQ-VAS was 72.5±23.3. For the Cartiva cohort, the MOXFQ domain scores were: Index 7.7±6.0, Walking/Standing 8.9±7.9, Pain 7.1±5.0, and Social Interaction 6.4±5.4. EQ-5D-5L Index score was 0.631±0.234 and the EQ-VAS was 74.8±20.8. There was no statistically significant difference between any MOXFQ domain or EQ-5D-5L scores. However, a negative trend in MOXFQ domains was identified for the Cartiva group, as well as a reoperation rate of 23.5%. Conclusions. The Cartiva SCI demonstrated no advantage over arthrodesis in PROMs, despite the presumed benefit of preserved ROM. A significant reoperation rate was also observed. Surgeons should be cautious in the use of this novel implant


Bone & Joint Research
Vol. 13, Issue 7 | Pages 315 - 320
1 Jul 2024
Choi YH Kwon TH Choi JH Han HS Lee KM

Aims. Achilles tendon re-rupture (ATRR) poses a significant risk of postoperative complication, even after a successful initial surgical repair. This study aimed to identify risk factors associated with Achilles tendon re-rupture following operative fixation. Methods. This retrospective cohort study analyzed a total of 43,287 patients from national health claims data spanning 2008 to 2018, focusing on patients who underwent surgical treatment for primary Achilles tendon rupture. Short-term ATRR was defined as cases that required revision surgery occurring between six weeks and one year after the initial surgical repair, while omitting cases with simultaneous infection or skin necrosis. Variables such as age, sex, the presence of Achilles tendinopathy, and comorbidities were systematically collected for the analysis. We employed multivariate stepwise logistic regression to identify potential risk factors associated with short-term ATRR. Results. From 2009 to 2018, the short-term re-rupture rate for Achilles tendon surgeries was 2.14%. Risk factors included male sex, younger age, and the presence of Achilles tendinopathy. Conclusion. This large-scale, big-data study reaffirmed known risk factors for short-term Achilles tendon re-rupture, specifically identifying male sex and younger age. Moreover, this study discovered that a prior history of Achilles tendinopathy emerges as an independent risk factor for re-rupture, even following initial operative fixation. Cite this article: Bone Joint Res 2024;13(7):315–320


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1184 - 1188
1 Nov 2023
Jennison T Ukoumunne OC Lamb S Goldberg AJ Sharpe I

Aims. The number of revision total ankle arthroplasties (TAAs) which are undertaken is increasing. Few studies have reported the survival after this procedure. The primary aim of this study was to analyze the survival of revision ankle arthroplasties using large datasets. Secondary aims were to summarize the demographics of the patients, the indications for revision TAA, further operations, and predictors of survival. Methods. The study combined data from the National Joint Registry and NHS Digital to report the survival of revision TAA. We have previously reported the failure rates and risk factors for failure after TAA, and the outcome of fusion after a failed TAA, using the same methodology. Survival was assessed using life tables and Kaplan Meier graphs. Cox proportional hazards regression models were fitted to compare failure rates. Results. A total of 228 patients underwent revision TAA. The mean follow-up was 2.6 years (SD 2.0). The mean time between the initial procedure and revision was 2.3 years (SD 1.8). The most commonly used implant was the Inbone which was used in 81 patients. A total of 29 (12.7%) failed; nine (3.9%) patients underwent a further revision, 19 (8.3%) underwent a fusion, and one (0.4%) had an amputation. The rate of survival was 95.4% (95% confidence interval (CI) 91.6 to 97.5) at one year, 87.7% (95% CI 81.9 to 91.7; n = 124) at three years and 77.5% (95% CI 66.9 to 85.0; n = 57) at five years. Revision-specific implants had a better survival than when primary implants were used at revision. A total of 50 patients (21.9%) had further surgery; 19 (8.3%) underwent reoperation in the first 12 months. Cox regression models were prepared. In crude analysis the only significant risk factors for failure were the use of cement (hazard ratio (HR) 3.02 (95% CI 1.13 to 8.09)) and the time since the primary procedure (HR 0.67 (95% CI 0.47 to 0.97)). No risk factors for failure were identified in multivariable Cox regression modelling. Conclusion. Revision TAAs have good medium term survival and low rates of further surgery. New modular revision implants appear to have improved the survival compared with the use of traditional primary implants at revision. Cite this article: Bone Joint J 2023;105-B(11):1184–1188


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1270 - 1276
1 Jul 2021
Townshend DN Bing AJF Clough TM Sharpe IT Goldberg A

Aims. This is a multicentre, non-inventor, prospective observational study of 503 INFINITY fixed bearing total ankle arthroplasties (TAAs). We report our early experience, complications, and radiological and functional outcomes. Methods. Patients were recruited from 11 specialist centres between June 2016 and November 2019. Demographic, radiological, and functional outcome data (Ankle Osteoarthritis Scale, Manchester Oxford Questionnaire, and EuroQol five-dimension five-level score) were collected preoperatively, at six months, one year, and two years. The Canadian Orthopaedic Foot and Ankle Society (COFAS) grading system was used to stratify deformity. Early and late complications and reoperations were recorded as adverse events. Radiographs were assessed for lucencies, cysts, and/or subsidence. Results. In all, 500 patients reached six-month follow-up, 420 reached one-year follow-up, and 188 reached two-year follow-up. The mean age was 67.8 years (23.9 to 88.5). A total of 38 patients (7.5%) presented with inflammatory arthritis. A total of 101 (20.0%) of implantations used patient-specific instrumentation; 167 patients (33.1%) underwent an additional procedure at the time of surgery. A total of seven patients died of unrelated causes, two withdrew, and one was lost to follow-up. The mean follow-up was 16.2 months (6 to 36). There was a significant improvement from baseline across all functional outcome scores at six months, one, and two years. There was no significant difference in outcomes with the use of patient-specific instrumentation, type of arthritis, or COFAS type. Five (1.0%) implants were revised. The overall complication rate was 8.8%. The non-revision reoperation rate was 1.4%. The 30-day readmission rate was 1.2% and the one-year mortality 0.74%. Conclusion. The early experience and complications reported in this study support the current use of the INFINITY TAA as a safe and effective implant in the treatment of end-stage ankle arthritis. Cite this article: Bone Joint J 2021;103-B(7):1270–1276


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_12 | Pages 17 - 17
10 Jun 2024
Porter A Nicolas AP Hakeem S Abdul N Elamin D Douglas-Harris M Ramaskandhan J Siddique M
Full Access

Background. Total Ankle Replacement (TAR) is an established treatment option for end-stage ankle arthritis. We analysed at minimum, 10-year patient-reported and clinical outcomes of 156 TARs from a single centre. We specifically compared outcomes between patients under 60 and over 60 at time of surgery. Methods. Data was collected retrospectively from our departmental patient database. It included all patients who underwent a TAR by a single surgeon between 2006 and 2010 and patients were divided into those under 60 and those over 60 at the time of surgery. Patient reported outcomes (PROMs), including WOMAC, SF-36 and patient satisfaction scores and complications were analysed preoperatively and at one, two, five and over 10 years postoperatively. Results. There were 156 patients included in this analysis, 61 were under 60 (mean age 50.29) and 95 were over 60 (mean age 69.12). A total of 12 patients had revision surgery, (nine in the under 60 group) and 52 patients were deceased at the time of analysis (10 in the under 60 group). At one year the over 60 group had less pain and better functional scores (p=0.02, p=0.017). At two, five and ten years there was no statistical difference in pain and function between groups. At two years the over 60s reported less stiffness and quicker return to activities of daily living (p=0.007, p=0.001). However, at five and 10 years there was no statistical difference in any domain. Conclusions. This study demonstrates that age does not correlate with a significant difference in pain or functional outcomes in patients who have TAR, at over 10 years follow up. The higher revision rates in the younger group may correlate with higher functional demand and lower mortality rate


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 6 - 6
8 May 2024
Miller D Senthi S Winson I
Full Access

Background. Total ankle replacements (TARs) are becoming increasingly more common in the treatment of end stage ankle arthritis. As a consequence, more patients are presenting with the complex situation of the failing TAR. The aim of this study was to present our case series of isolated ankle fusions post failed TAR using a spinal cage construct and anterior plating technique. Methods. A retrospective review of prospectively collected data was performed for 6 patients that had isolated ankle fusions performed for failed TAR. These were performed by a single surgeon (IW) between March 2012 and October 2014. The procedure was performed using a Spinal Cage construct and grafting in the joint defect and anterior plating. Our primary outcome measure was clinical and radiographic union at 1 year. Union was defined as clinical union and no evidence of radiographic hardware loosening or persistent joint lucent line at 1 year. Results. The mean follow-up was 37.3 months (SD 13.2). Union was achieved in 5 of the 6 patients (83%). One patient had a non-union that required revision fusion incorporating the talonavicular joint that successfully went on to unite across both joints. Another patient had radiographic features of non-union but was clinically united and asymptomatic and one required revision surgery for a bulky symptomatic lateral malleolus with fused ankle joint. Conclusion. The failing TAR presents a complex clinical situation. After removal of the implant there is often a large defect which if compressed leads to a leg length discrepancy and if filled with augment can increase the risk of non-union. Multiple methods have been described for revision, with many advocating fusion of both the ankle joint and subtalar joint. We present our case series using a spinal cage and anterior plating that allows preservation of the subtalar joint and a high rate of union


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_11 | Pages 2 - 2
4 Jun 2024
Townshend D Bing A Clough T Sharpe I Blundell C Davenport J Davies H Davis J Dhar S Goldberg A Karski M Hepple S Kakwani R McKinley J Murty A Ragland M Shalaby H Smith R Taylor H
Full Access

Introduction. This is a multi-centre, prospective, observational study of 503 INFINITY fixed bearing total ankle arthroplasties. We report the minimum two-year results of this prosthesis which was introduced to the UK Market in 2014 and is now the most used ankle arthroplasty in the National Joint Registry of England and Wales. Methods. Patients were recruited from 11 centres in the United Kingdom between June 2016 and November 2019. Demographic, radiographic, and functional outcome data (Ankle Osteoarthritis Scale, Manchester Oxford Foot Ankle Questionnaire and Euroquol 5D-5L) were collected preoperatively, at 6 months, 1 year and 2 years and 5 years. The average age was 67.8 (range 23.9 to 88.5) and average BMI 29.3 (18.9 to 48.0). The COFAS grading system was used to stratify deformity. There were 261 (51.9%) COFAS Type 1, 122 (24.2%) COFAS Type 2, 31 (6.2%) COFAS 3 and 89 (17.7%) COFAS type 4. 38 patients (7.6%) presented with inflammatory arthritis. 99 (19.7%) implantations utilised patient specific instrumentation. Complications and reoperations were recorded as adverse events. Radiographs were assessed for lucencies, cysts and/or subsidence. Results. The mean follow up was 34.2 months (range 24–64). 15 patients have died, 8 withdrawn and 3 lost to follow up. 8 implants (1.6%) have been revised. According to the Glazebrook classification there were low grade complications in 6.6%, medium grade in 1.4% and high grade in 1.6%. There have been an additional 13 non revision re-operations (2.6%) at the latest follow up. There was a significant (p < 0.01) improvement across all functional outcome scores at a minimum of 2yr follow up. Discussion and conclusion. This large cohort has shown a low early revision rate and high functional outcomes with a low-profile fixed bearing prosthesis


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_11 | Pages 22 - 22
4 Jun 2024
Woods A Henari S Kendal A Rogers M Brown R Sharp R Loizou CL
Full Access

Background. Open or arthroscopic ankle fusion (AAF) is a successful operative treatment for end-stage ankle arthritis. Evidence suggest that AAFs have better outcomes. In addition to the operative technique other patient-factors can influence outcomes. The most significant complication of ankle fusion is a non-union. To better understand the risk factors related to this we undertook a retrospective investigation of primary AAFs. Methods. We reviewed all AAFs conducted at our institution over a 10-year period. Patients excluded if they had simultaneous fusion of neighbouring joints or were lost to follow-up. The primary outcome variable was radiographic union. Other operative complications were analysed as secondary outcomes. Two hundred and eighty-four eligible AAFs in 271 patients were performed over the study period. Results. The overall non-union rate was 7.7 %. Univariate logistic regression analysis found that smoking (6.2% non-union in non-smokers vs 24% in smokers) and prior triple fusion (5.5% non-union in the absence of prior triple fusion vs 70% in the presence of a prior triple fusion) were independent risk factors for non-union. Multivariate analysis showed that only prior triple fusion was predictive (OR 40.0 [9.4,170.3], p < 0.0001). Increasing age, obesity (BMI >30), surgical grade (trainee vs consultant), diabetes or the degree of weightbearing status post-operatively were not significant risk factors of non-union. The leading cause of reoperation was the removal of metal (18%). There were 5 superficial (1.8%) and 4 deep (1.4%) infections. Kaplan-Meier survival analysis showed a 75% ‘survivorship’ of the subtalar joint at 10 years following an arthroscopic ankle fusion. Conclusion. This is the largest case series of AAFs in the literature and the first to demonstrate that patients who had an AAF performed after a previous triple fusion have unacceptably high non-union rates and may benefit from other surgical options. This study data could also useful for patient consenting purposes


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_13 | Pages 20 - 20
17 Jun 2024
Jagani N Harrison W Davenport J Karski M Ring J Smith R Clough T
Full Access

Aims. Retrospective review of a consecutive series of 1,168 total ankle replacements (TAR) performed at Wrightington, to analyse modes of failure and clinical outcomes following TAR failure. Methods. All patients undergoing TAR between November 1993 – June 2019 were collated (4–25 year follow-up; mean 13.7 years). 6 implants were used (300 STAR, 100 Buechal Pappas, 509 Mobility, 118 Zenith, 41 Salto and 100 Infinity). 5 surgeons, all trained in TAR, performed the surgery. Modes of failure were collated and clinical and radiological outcomes recorded for the revisional surgery following failure of the TAR. Results. 156 (13.4%) TARs failed (47STAR 15.6%, 16BP 16%, 77Mobility 15.1%, 6Salto 14.6%, 10Zenith 8.5% and 0Infinity 0%). Mean time to failure 5.8 years (0.1- 21.4 years). The 4 most common modes of failure were 44.9% aseptic loosening, 11.5% gutter pain, 10.9% infection and 10.3% recurrent edge loading. 50 underwent conversion to tibiotalocalcaneal (TTC) fusion with nail with 9 (18%) failing to fuse. 31 underwent revision TAR with 2 (6.5%) subsequently failed. 22 underwent ankle fusion with 10 (45%) failing to fuse. 21 underwent polyethylene exchange of which 8 (38%) had further poly failure. 20 (12.8%) were managed conservatively, 2 (1.3%) required below knee amputation and 6 were listed but lost to follow-up. 81 of the 1168 (7%) consecutive cohort were lost to follow-up. Conclusions. 13.4% of the TAR cohort have failed at average follow-up 13.7 years. There was no difference in failure modes across the implant designs. Whilst the fixed bearing has the shortest follow-up, it may be performing better as there have been no failures so far. Prior to October 2016, most revisions were to fusion (TTC 18% failure rate, ankle 45% failure rate), whereas post 2016, 57% patients elected for revision TAR (6.5% failure)


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 220 - 226
1 Feb 2020
Clough TM Ring J

Aims. Arthroplasty for end-stage hallux rigidus (HR) is controversial. Arthrodesis remains the gold standard for surgical treatment, although is not without its complications, with rates of up to 10% for nonunion, 14% for reoperation and 10% for metatarsalgia. The aim of this study was to analyze the outcome of a double-stemmed silastic implant (Wright-Medical, Memphis, Tennessee, USA) for patients with end-stage HR. Methods. We conducted a retrospective review of 108 consecutive implants in 76 patients, between January 2005 and December 2016, with a minimum follow-up of two years. The mean age of the patients at the time of surgery was 61.6 years (42 to 84). There were 104 females and four males. Clinical, radiological, patient reported outcome measures (PROMS) data, a visual analogue score (VAS) for pain, and satisfaction scores were collected. Results. The survivorship at a mean follow-up of 5.3 years (2.1 to 14.1) was 97.2%. The mean Manchester Oxford Foot and Ankle Questionnaire (MOXFQ) scores improved from 78.1 to 11.0, and VAS scores for pain from 7/10 to 1.3/10. The rate of satisfaction was 90.6%. Three implants (2.8%) required revision; one for infection, one-month postoperatively, and two for stem breakage at 10.4 and 13.3 years postoperatively. There was a 1.9% reoperation rate other than revision, 23.1% of patients developed a minor complication, and 21.1% of patients had non-progressive and asymptomatic cysts on radiological review. Conclusion. We report a 97.2% survivorship at a mean follow-up of 5.3 years with this implant. We did not find progressive osteolysis, as has been previously reported. These results suggest that this double-stemmed silastic implant provides a predictable and reliable alternative with comparable outcomes to arthrodesis for the treatment of end-stage HR. Cite this article: Bone Joint J 2020;102-B(2):220–226


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1611 - 1618
1 Oct 2021
Kavarthapu V Budair B

Aims. In our unit, we adopt a two-stage surgical reconstruction approach using internal fixation for the management of infected Charcot foot deformity. We evaluate our experience with this functional limb salvage method. Methods. We conducted a retrospective analysis of prospectively collected data of all patients with infected Charcot foot deformity who underwent two-stage reconstruction with internal fixation between July 2011 and November 2019, with a minimum of 12 months’ follow-up. Results. We identified 23 feet in 22 patients with a mean age of 56.7 years (33 to 70). The mean postoperative follow-up period was 44.7 months (14 to 99). Limb salvage was achieved in all patients. At one-year follow-up, all ulcers have healed and independent full weightbearing mobilization was achieved in all but one patient. Seven patients developed new mechanical skin breakdown; all went on to heal following further interventions. Fusion of the hindfoot was achieved in 15 of 18 feet (83.3%). Midfoot fusion was achieved in nine of 15 patients (60%) and six had stable and painless fibrous nonunion. Hardware failure occurred in five feet, all with broken dorsomedial locking plate. Six patients required further surgery, two underwent revision surgery for infected nonunion, two for removal of metalwork and exostectomy, and two for dynamization of the hindfoot nail. Conclusion. Two-stage reconstruction of the infected and deformed Charcot foot using internal fixation and following the principle of ‘long-segment, rigid and durable internal fixation, with optimal bone opposition and local antibiotic elusion’ is a good form of treatment provided a multidisciplinary care plan is delivered. Cite this article: Bone Joint J 2021;103-B(10):1611–1618