Advertisement for orthosearch.org.uk
Results 1 - 20 of 67
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 52 - 52
1 Mar 2021
Harris A O'Grady C Sensiba P Vandenneucker H Huang B Cates H Christen B Hur J Marra D Malcorps J Kopjar B
Full Access

Patients ≤ 55 years have a high primary TKA revision rate compared to patients >55 years. Guided motion knee devices are commonly used in younger patients yet outcomes remain unknown. In this sub-group analysis of a large multicenter study, 254 TKAs with a second-generation guided motion knee implant were performed between 2011–2017 in 202 patients ≤ 55 years at seven US and three European sites. Revision rates were compared with Australian Joint Registry (AOANJRR) 2017 data. Average age 49.7 (range 18–54); 56.4% females; average BMI 34 kg/m2; 67.1% obese; patellae resurfaced in 98.4%. Average follow-up 4.2 years; longest follow-up six years; 27.5% followed-up for ≥ five years. Of eight revisions: total revision (one), tibial plate replacements (three), tibial insert exchanges (four). One tibial plate revision re-revised to total revision. Revision indications were mechanical loosening (n=2), infection (n=3), peri-prosthetic fracture (n=1), and instability (n=2). The Kaplan-Meier revision estimate was 3.4% (95% C.I. 1.7% to 6.7%) at five years compared to AOANJRR rate of 6.9%. There was no differential risk by sex. The revision rate of the second-generation guided motion knee system is lower in younger patients compared to registry controls


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 56 - 56
17 Apr 2023
Arif M Makaram N Macpherson G Ralston S
Full Access

Patients with Paget's Disease of Bone (PDB) more frequently require total hip arthroplasty (THA) and total knee arthroplasty (TKA). However, controversy remains regarding their outcome. This project aims to evaluate the current literature regarding outcomes following THA and TKA in PDB patients. MEDLINE, EMBASE and Cochrane databases were searched on February 15th, 2022. Inclusion criteria comprised studies evaluating outcomes following THA/TKA in PDB patients. Quality of included studies was assessed using the Newcastle-Ottawa Scale. 19 articles (published between 1976–2022) were included, comprising 58,695 patients (48,766 controls and 10,018 PDB patients), from 209 potentially relevant titles. No study was of high quality. PDB patient pooled mortality was 32.5% at mean 7.8(0.1-20) years following THA and 31.0% at mean 8.5(2-20) years following TKA. PDB patient revision rate was 4.4% at mean 7.2(0-20) years following THA and 2.2% at mean 7.4(2-20) years following TKA. Renal complications, respiratory complications, heterotopic ossification, and surgical site infection were the most common medical and surgical complications. The largest systematic review, to date, evaluating outcomes following THA and TKA in PDB patients. All functional outcome scores improved. PDB patient revision rate was comparable to UK National Joint Registry. However, there is a significant need for prospective matched case-control studies to robustly compare outcomes in PDB patients with unaffected counterparts


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 14 - 14
17 Nov 2023
Raghu A Kapilan M Sahae I Tai S
Full Access

Abstract. Background. 1. 63,284 patients presented with neck of femur fractures in England in 2020 (NHFD report 2021)2. To maximise theatre efficiency during the first wave of COVID-19, NHSE guidance recommended the use of HA for most patients requiring arthroplasty.3. The literature reports an incidence of Hemiarthroplasty dislocations of 1–15%. Aims. 1. To study the number and possible causes of dislocations in patients with Primary hemiarthroplasty for fracture neck of femur2. To compare our data with national and international data in terms of dislocation and revision rates for Hemiarthroplasty. Methods. Retrospective study Duration- 1st April 2021–31st March 20223. Inclusion criteria- Patients with neck of femur fracture treated with Hemiarthroplasty. Exclusion criteria- Patients treated with other surgical options for neck of femur fractures. Results. 1. No. of neck of femur patients- 4442. No. of patients treated with Hemiarthroplasty- 2143. No. of dislocations- 44. 75% were female, 75% had AMTS>7, 50% were operated within 36 hours of trauma, 75% dislocated within a month of surgery, 75% of the dislocations were revised. 5. One dislocation was due to >72 hour delay to surgery, second dislocation was due to smaller offset and shortening, third was due to acetabular dysplasia, fourth was due to larger head used. Discussion-1. Our 1.86% dislocation rate matches that in the literature of 1–6%2. 75% dislocated within a month of surgery matches that in the literature that maximum dislocations occur within one month. 3. Closed reduction as definitive method of management of dislocation 25% matches that in the literature of 22–25%4. 75% dislocations revised similar to literature of 75–80% revision rate. Conclusion. Pre-operative templating can reduce surgical error involving limb length discrepancy and shortening to prevent dislocations. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Results in patients undergoing total hip arthroplasty (THA) for femoral head osteonecrosis (ON) when compared with primary osteoarthritis (OA) are controversial. Different factors like age, THA type or surgical technique may affect outcome. We hypothesized that patients with ON had an increased revision rate compared with OA. We analysed clinical outcome, estimated the survival rate for revision surgery, and their possible risk factors, in two groups of patients. In this retrospective cohort analysis of our prospective database, we assessed 2464 primary THAs implanted between 1989 and 2017. Patients with OA were included in group 1, 2090 hips; and patients with ON in group 2, 374 hips. In group 2 there were more men (p<0.001), patients younger than 60 years old (p<0.001) and with greater physical activity (p<0.001). Patients with lumbar OA (p<0.001) and a radiological acetabular shape type B according to Dorr (p<0.001) were more frequent in group 1. Clinical outcome was assessed according to the Harris Hip Score and radiological analysis included postoperative acetabular and femoral component position and hip reconstruction. Kaplan-Meier survivorship analysis was used to estimate the cumulative probability of not having revision surgery for different reasons. Univariate and multivariate Cox regression models were used to assess risk factors for revision surgery. Clinical improvement was better in the ON at all intervals. There were 90 hips revised, 68 due to loosening or wear, 52 (2.5%) in group 1, and 16 (4.3%) in group 2. Overall, the survival rate for revision surgery for any cause at 22 years was 88.0 % (95% CI, 82-94) in group 1 and 84.1% (95% CI, 69 – 99) in group 2 (p=0.019). Multivariate regression analysis showed that hips with conventional polyethylene (PE), compared with highly-cross linked PEs or ceramic-on-ceramic bearings, (p=0.01, Hazard Ratio (HR): 2.12, 95% CI 1.15-3.92), and cups outside the Lewinnek´s safe zone had a higher risk for revision surgery (p<0.001, HR: 2.57, 95% CI 1.69-3.91). Modern highly-cross linked PEs and ceramic-on-ceramic bearings use, and a proper surgical technique improved revision rate in patients undergoing THA due to ON compared with OA


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 20 - 20
17 Nov 2023
van Duren B France J Berber R Matar H James P Bloch B
Full Access

Abstract. Objective. Up to 20% of patients can remain dissatisfied following TKR. A proportion of TKRs will need early revision with aseptic loosening the most common. The ATTUNE TKR was introduced in 2011 as successor to its predicate design The PFC Sigma (DePuy Synthes, Warsaw, In). However, following reports of early failures of the tibial component there have been ongoing concerns of increased loosening rates with the ATTUNE TKR. In 2017 a redesigned tibial baseplate (S+) was introduced, which included cement pockets and an increased surface roughness to improve cement bonding. Given the concerns of early tibial loosening with the ATTUNE knee system, this study aimed to compare revision rates and those specific to aseptic loosening of the ATTUNE implant in comparison to an established predicate as well as other implant designs used in a high-volume arthroplasty centre. Methods. The Attune TKR was introduced to our unit in December 2011. Prior to this we routinely used a predicate design with an excellent long-term track record (PFC Sigma) which remains in use. In addition, other designs were available and used as per surgeon preference. Using a prospectively maintained database, we identified 10,202 patients who underwent primary cemented TKR at our institution between 01/04/2003–31/03/2022 with a minimum of 1 year follow-up (Mean 8.4years, range 1–20years): 1) 2406 with ATTUNE TKR (of which 557 were S+) 2) 4652 with PFC TKR 3) 3154 with other cemented designs. All implants were cemented using high viscosity cement. The primary outcome measures were all-cause revision, revision for aseptic loosening, and revision for tibial loosening. Kaplan-Meier survival analysis and Cox regression models were used to compare the primary outcomes between groups. Matched cohorts were selected from the ATTUNE subsets (original and S+) and PFC groups using the nearest neighbor method for radiographic analysis. Radiographs were assessed to compare the presence of radiolucent lines in the Attune S+, standard Attune, and PFC implants. Results. At a mean of 8.4 years follow-up, 308 implants underwent revision equating to 3.58 revisions per 1000 implant-years. The lowest risk of revision was noted in the ATTUNE cohort with 2.98 per 1000-implant-years where the PFC and All Other Implant groups were 3.15 and 4.4 respectively. Aseptic loosing was the most common cause for revision across all cemented implants with 76% (65/88) of involving loosening of the tibia. Survival analysis comparing the ATTUNE cohort to the PFC and All Other Cemented Implant cohorts showed no significant differences for: all-cause revision, aseptic loosening, or tibial loosening (p=0.15,0.77,0.47). Radiolucent lines were detected in 4.6%, 5.8%, and 5.0% of the ATTUNE S+, standard ATTUNE, and PFC groups respectively. These differences were not significant. Conclusion. This study represents the largest non-registry review of the original and S+ ATTUNE TKR in comparison to its predicate design as well as other cemented implants. There appears to be no significant increased revision rate for all-cause revision or aseptic loosening. Radiographic analysis also showed no significant difference in peri-implant radiolucency. It appears that concerns of early loosening may be unfounded. Declaration of Interest. (a) fully declare any financial or other potential conflict of interest


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 143 - 143
1 Nov 2021
McCarthy C Mahon J Sheridan G Welch-Phillips A O'Byrne J Kenny P
Full Access

Introduction and Objective. Ceramic on Ceramic bearings in Total Hip Arthroplasty (THA) afford a low friction coefficient, low wear rates and extreme hardness. Significant complications include hip squeak, ceramic fracture and poor polyethylene performance in revision procedures due to imbedding of abrasive microscopic ceramic fragments. We report on the results of this bearing at a minimum of 10 years. Materials and Methods. A single-centre retrospective review of 449 THAs was performed. Primary outcome measures included aseptic revision and all-cause revision rates at a minimum of 10 years post operatively. Evaluation of functionality was performed with WOMAC and SF-36 scores which were performed pre-operatively and at intervals of 6 months, one year, 2 years, 5 years and 10 years post operatively. Results. There was a 6.2% (n=28) all-cause and 5.3% (n=24) aseptic revision rate for ceramic on ceramic total hip arthroplasty at minimum of 10 years with a mean time to revision 4.8 years (range 2 months − 11.6 years). Notably, there were 2 revisions for ceramic head fracture, one for ceramic liner fracture, 3 for aseptic loosening and 3 revisions for squeaking. Pain of unknown origin was the most common reason for revision. There was an improvement in postoperative WOMAC scores from a mean of 59.8 (range 15–95) pre-operatively to a mean of 15.6 (range 0–78) at 10 years. Conclusions. This study showed good functional outcomes but high revision rates for CoC THA at a minimum of 10 years. The role for CoC bearings in THA has been called into question in recent years and may continue to decline in popularity, even in younger patients. Further large scale studies are important to assess the long-term outcomes of this bearing surface


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 129 - 129
1 Nov 2021
Vermue H Tack P Jan V
Full Access

Introduction and Objective. Total knee arthroplasty (TKA) is a frequently and increasingly performed surgery in the treatment of disabling knee osteoarthritis. The rising number of procedures and related revisions pose an increasing economic burden on health care systems. In an attempt to lower the revision rate due to component malalignment and soft tissue imbalance in TKA, robotic assistance (RA) has been introduced in the operating theatre. The primary objective of this study is to provide the results of a theoretical, preliminary cost-effectiveness analysis of RA TKA. Materials and Methods. A Markov state-transition model was designed to model the health status of sixty-seven-year-old patients in need of TKA due to primary osteoarthritis over a twenty-year period following their knee joint replacement. Transitional probabilities and independent variables were extracted from existing literature. Patients’ state in the transition model was able to change on an annual basis. The main differences between the conventional and RA TKA were the outlier rate in the coronal plane and the cost of the procedure. In RA TKA, it was hypothesized that there were lower revision rates due to a lower outlier rate compared to conventional TKA. Results. The value attributed to the utility both for primary and revision surgery has the biggest impact on the ICER, followed by the rate of successful primary surgery and the cost of RA-technology. Only 2.18–2.34% of the samples yielded from the probabilistic sensitivity analysis proved to be cost-effective (threshold set at $50000/QALY). A calculated surgical volume of at least 191–253 cases per robot per year is needed to prove cost-effective taking the predetermined parameter values into account. Conclusions. Robot-assisted TKA might be a cost-effective procedure compared to conventional TKA if a minimum of 191 cases are performed on a yearly basis, depending on the cost of the robot. The cost-benefit of the robotic TKA surgery is mainly based on a decreased revision rate. This study is based on the assumption that alignment is a predictor of success in total knee arthroplasty. Until there is data confirming the assertion that alignment predicts success robot-assisted surgery cannot be recommended


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 23 - 23
2 Jan 2024
Dragonas C Waseem S Simpson A Leivadiotou D
Full Access

The advent of modular implants aims to minimise morbidity associated with revision of hemiarthroplasty or total shoulder arthroplasty (TSA) to reverse shoulder arthroplasty (RSR) by allowing retention of the humeral stem. This systematic review aimed to summarise outcomes following its use and reasons why modular humeral stems may be revised. A systematic review of Pubmed, Medline and EMBASE was performed according to PRISMA guidelines of all patients undergoing revision of a modular hemiarthroplasty or TSA to RSR. Primary implants, glenoid revisions, surgical technique and opinion based reports were excluded. Collected data included demographics, outcomes and incidence of complications. 277 patients were included, with a mean age of 69.8 years (44-91) and 119 being female. Revisions were performed an average of 30 months (6-147) after the index procedure, with the most common reason for revision being cuff failure in 57 patients. 165 patients underwent modular conversion and 112 underwent stem revision. Of those that underwent humeral stem revision, 18 had the stem too proximal, in 15 the stem was loose, 10 was due to infection and 1 stem had significant retroversion. After a mean follow up of 37.6 months (12-91), the Constant score improved from a mean of 21.8 to 48.7. Stem revision was associated with a higher complication rate (OR 3.13, 95% CI 1.82-5.39). The increased use of modular stems has reduced stem revision, however 40% of these implants still require revision due to intra-operative findings. Further large volume comparative studies between revised and maintained humeral stems post revision of modular implants can adequately inform implant innovation to further improve the stem revision rate


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 5 - 5
14 Nov 2024
Panagiota Glynou S Musbahi O Cobb J
Full Access

Introduction. Knee arthroplasty (KA), encompassing Total Knee Replacement (TKR) and Unicompartmental Knee Replacement (UKR), is one of the most common orthopedic procedures, aimed at alleviating severe knee arthritis. Postoperative KA management, especially radiographic imaging, remains a substantial financial burden and lacks standardised protocols for its clinical utility during follow-up. Method. In this retrospective multicentre cohort study, data were analysed from January 2014 to March 2020 for adult patients undergoing primary KA at Imperial NHS Trust. Patients were followed over a five-year period. Four machine learning models were developed to evaluate if post-operative X-ray frequency can predict revision surgery. The best-performing model was used to assess the risk of revision surgery associated with different number of X-rays. Result. The study assessed 289 knees with a 2.4% revision rate. The revision group had more X-rays on average than the primary group. The best performing model was Logistic Regression (LR), which indicated that each additional X-ray raised the revision risk by 52% (p<0.001). Notably, having four or more X-rays was linked to a three-fold increase in risk of revision (OR=3.02; p<0.001). Our results align with the literature that immediate post-operative X-rays have limited utility, making the 2nd post-operative X-ray of highest importance in understanding the patient's trajectory. These insights can enhance management by improving risk stratification for patients at higher revision surgery risk. Despite LR being the best-performing model, it is limited by the dataset's significant class imbalance. Conclusion. X-ray frequency can independently predict revision surgery. This study provides insights that can guide surgeons in evidence-based post-operative decision-making. To use those findings and influence post-operative management, future studies should build on this predictive model by incorporating a more robust dataset, surgical indications, and X-ray findings. This will allow early identification of high-risk patients, allowing for personalised post-operative recommendations


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 98 - 98
2 Jan 2024
Mehta S Goel A Mahajan U Reddy N Bhaskar D
Full Access

Dislocation post THA confers a higher risk of re-dislocation (Kotwal et al, 2009). The dual mobility (DM) cup design (1974) was aimed at improving the stability by increasing the femoral head to neck ratio (Cuthbert et al., 2019) combining the ideas of low friction arthroplasty with increased jump distance associated with a big head arthroplasty. Understand the dislocation rates, rates of aseptic loosening, infection rate and revision rates between the 2 types of constructs to provide current and up-to date evidence. Medline, pubmed, embase and Cochrane databases were used based on PRISMA guidelines. RevMan software was used for the meta-analysis. Studies (English literature) which used DM construct with atleast 6 months follow-up used as intervention and non DM construct as control were included. 2 independent reviewers conducted the review with a third reviewer in case of difference in opinion regarding eligibility. Primary outcome was dislocation rate and secondary outcome was rate of revision. 564 articles identified out of which 44 articles were screened for full texts and eventually 4 systematic review articles found eligible for the study. Thus, study became a review of systematic reviews. From the 4 systematic reviews, another 35 studies were identified for data extraction and 13 papers were used for meta-analysis. Systematic reviews evaluated, projected an average follow up of 6-8 years with significantly lower dislocation rates for DM cups. The total number of patients undergoing DM cup primary THA were 30,559 with an average age 71 years while the control group consisted of 218,834 patients with an average age of 69 years. DM group had lower rate of dislocation (p < 0.00001), total lower rate of cup revision (p < 0.00001, higher incidence of fracture (p>0.05). DM THA is a viable alternative for conventional THA. The long-term results of DM cups in primary THA need to be further evaluated using high quality prospective studies and RCTs


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 1 - 1
17 Nov 2023
Mehta S Goel A Mahajan U Reddy R Bhaskar D
Full Access

Abstract. Introduction. Dislocation post THA confers a higher risk of re-dislocation (Kotwal et al, 2009). The dual mobility (DM) cup design (1974) was aimed at improving the stability by increasing the femoral head to neck ratio (Cuthbert et al., 2019) combining the ideas of low friction arthroplasty with increased jump distance associated with a big head arthroplasty. Aims. Understand the dislocation rates, rates of aseptic loosening, infection rate and revision rates between the 2 types of constructs to provide current and up-to date evidence. Methods. Medline, pubmed, embase and Cochrane databases were used based on PRISMA guidelines. RevMan software was used for the meta-analysis. Studies (English literature) which used DM construct with atleast 6 months follow-up used as intervention and non DM construct as control were included. 2 independent reviewers conducted the review with a third reviewer in case of difference in opinion regarding eligibility. Primary outcome was dislocation rate and secondary outcome was rate of revision. Results. 564 articles identified out of which 44 articles were screened for full texts and eventually 4 systematic review articles found eligible for the study. Thus, study became a review of systematic reviews. From the 4 systematic reviews, another 35 studies were identified for data extraction and 13 papers were used for meta-analysis. Systematic reviews evaluated, projected an average follow up of 6–8 years with significantly lower dislocation rates for DM cups. The total number of patients undergoing DM cup primary THA were 30,559 with an average age 71 years while the control group consisted of 218,834 patients with an average age of 69 years. DM group had lower rate of dislocation (p < 0.00001), total lower rate of cup revision (p < 0.00001, higher incidence of fracture (p>0.05). Conclusion. DM THA is a viable alternative for conventional THA. The long-term results of DM cups in primary THA need to be further evaluated using high quality prospective studies and RCTs. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 21 - 21
17 Nov 2023
Matar H van Duren B Berber R Bloch B James P Manktelow A
Full Access

Abstract. Objectives. Total hip replacement (THR) is one of the most successful and cost-effective interventions in orthopaedic surgery. Dislocation is a debilitating complication of THR and managing an unstable THR constitutes a significant clinical challenge. Stability in THR is multifactorial and is influenced by surgical, patient and implant related factors. It is established that larger diameter femoral heads have a wider impingement-free range of movement and an increase in jump distance, both of which are relevant in reducing the risk of dislocation. However, they can generate higher frictional torque which has led to concerns related to increased wear and loosening. Furthermore, the potential for taper corrosion or trunnionosis is also a potential concern with larger femoral heads, particularly those made from cobalt-chrome. These concerns have meant there is hesitancy among surgeons to use larger sized heads. This study presents the comparison of clinical outcomes for different head sizes (28mm, 32mm and 36mm) in primary THR for 10,104 hips in a single centre. Methods. A retrospective study of all consecutive patients who underwent primary THR at our institution between 1st April 2003 and 31st Dec 2019 was undertaken. Institutional approval for this study was obtained. Demographic and surgical data were collected. The primary outcome measures were all-cause revision, revision for dislocation, and all-cause revision excluding dislocation. Continuous descriptive statistics used means, median values, ranges, and 95% confidence intervals where appropriate. Kaplan-Meier survival curves were used to estimate time to revision. Cox proportional hazard regression analysis was used to compare revision rates between the femoral head size groups. Adjustments were made for age at surgery, gender, primary diagnosis, ASA score, articulation type, and fixation method. Results. 10,104 primary THRs were included; median age 68.6 years with 61.5% females. A posterior approach was performed in 71.6%. There were 3,295 hips with 28 mm heads (32.6%), 4,858 (48.1%) with 32 mm heads and 1,951 (19.3%) with 36 mm heads. Overall rate of revision was 1.7% with the lowest rate recorded for the 36mm group (2.7% vs. 1.3% vs. 1.1%). Cox regression analysis showed a decreased risk of all-cause revision for 32mm & 36mm head sizes as compared to 28mm; this was statistically significant for the 32mm group (p = 0.01). Risk of revision for dislocation was significantly reduced in both 32mm (p = 0.03) and 36mm (p = 0.03) head sizes. Analysis of all cause revision excluding dislocation showed no significant differences between head sizes. Conclusion. There was a significantly reduced risk of revision for all causes, but particularly revision for dislocation with larger head sizes (36mm & 32mm vs. 28mm). Concerns regarding increased risk of early revision for aseptic loosening, polyethylene wear or taper corrosion with larger heads appear to be unfounded in this cohort of 10,104 patients with a mean of 6.0-year follow-up. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 83 - 83
1 Mar 2021
McAleese T Quinn M Graves S Clark G
Full Access

Abstract. Objectives. Patella resurfacing in primary total knee arthroplasty (TKA) remains a contentious issue. Australian rates of patellar resurfacing are 66.6%, significantly higher compared to UK rates of 8–15% and Swedish rates of 2%. Resurfacing has gained popularity in Australia since registry data has shown decreased revision rates with no increase in patellar component related complications. We present for discussion an analysis of 113,694 total knee arthroplasties using commonly implanted prostheses in the UK. Methods. We included all TKA's since the Australian register's conception on 01/09/1999 for a primary diagnosis of osteoarthritis involving the use of either the Triathlon or Duracon implant with and without patellar components. The primary outcome of the study was time to revision for Triathlon's resurfaced and non-resurfaced prosthesis compared to the Duracon's equivalent data. We also analysed the reasons for revision between the 4 groups, type of revision and complication rates. We then compared minimally stabilised and posterior stabilised prostheses. Results. The cumulative revision rate for Triathlon prostheses with resurfacing after 12 years was 3.2% (95% CI, 2.9% to 3.6%) compared to 5.6% (95% CI, 5.0% to 6.2%) without resurfacing. Duracon's equivalent data was 6.3% with resurfacing and 5.9% without resurfacing. Triathlon prosthesis with resurfacing have much lower rates of revision due to loosening, patellofemoral pain, patellar erosion compared to unresurfaced Triathlon prostheses. Conclusion. Triathlon with re-surfacing has lower revision rates regardless of age or BMI. Previous concerns regarding patellofemoral loosening, tibial wear, maltracking relate to Duracon only, indicating the importance of implant specific studies. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 22 - 22
17 Nov 2023
van Duren B Firth A Berber R Matar H Bloch B
Full Access

Abstract. Objectives. Obesity is prevalent with nearly one third of the world's population being classified as obese. Total knee arthroplasty (TKA) is an effective treatment option for high BMI patients achieving similar outcomes to non-obese patients. However, increased rates of aseptic loosening in patients with a high BMI have been reported. In patients with high BMI/body mass there is an increase in strain placed on the implant fixation interfaces. As such component fixation is a potential concern when performing TKA in the obese patient. To address this concern the use of extended tibial stems in cemented implants or cementless fixation have been advocated. Extend tibial stems are thought to improve implant stability reducing the micromotion between interfaces and consequently the risk of aseptic loosening. Cementless implants, once biologic fixation is achieved, effectively integrate into bone eliminating an interface. This retrospective study compared the use of extended tibial stems and cementless implants to conventional cemented implants in high BMI patients. Methods. From a prospectively maintained database of 3239 primary Attune TKA (Depuy, Warsaw, Indiana), obese patients (body mass index (BMI) >30 kg/m²) were retrospectively reviewed. Two groups of patients 1) using a tibial stem extension [n=162] and 2) cementless fixation [n=163] were compared to 3) a control group (n=1426) with a standard tibial stem cemented implant. All operations were performed by or under the direct supervision of specialist arthroplasty surgeons. Analysis compared the groups with respect to class I, II, and III (BMI >30kg/m², >35 kg/m², >40 kg/m²) obesity. The primary outcome measures were all-cause revision, revision for aseptic loosening, and revision for tibial loosening. Kaplan-Meier survival analysis and Cox regression models were used to compare the primary outcomes between groups. Where radiographic images at greater than 3 months post-operatively were available, radiographs were examined to compare the presence of peri-implant radiolucent lines. Results. The mean follow-up of 4.8, 3.4, and 2.5 years for cemented, stemmed, and cementless groups respectively. In total there were 34 all-cause revisions across all the groups with revision rates of 4.55, 5.50, and 0.00 per 1000-implant-years for cemented, stemmed, and cementless groups respectively. Survival Analysis did not show any significant differences between the three groups for all-all cause revision. There were 6 revisions for aseptic loosening (5 tibial and 1 femoral); all of which were in the standard cemented implant group. In contrast there were no revisions in the stemmed or cementless implant groups, however, this was not significant on survival analysis. Analysis looking at class I, II, and III obesity also did not show any significant differences in survival for all cause revision or aseptic loosening. Conclusion. This retrospective analysis showed that there were no revisions required for aseptic loosening when either a cemented stemmed or cementless implant were used in obese patients. These findings are in line with other studies showing that cementless fixation or extended stem implants are a reasonable option in obese patients who represent an increasing cohort of patients requiring TKR. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 40 - 40
17 Apr 2023
Saiz A Kong S Bautista B Kelley J Haffner M Lee M
Full Access

With an aging population and increase in total knee arthroplasty, periprosthetic distal femur fractures (PDFFs) have increased. The differences between these fractures and native distal femur fractures (NDFF) have not been comprehensively investigated. The purpose of this study was to compare the demographic, fracture, and treatment details of PDFFs compared to NDFFs. A retrospective study of patients ≥ 18 years old who underwent surgical treatment for either a NDFF or a PDFF from 2010 to 2020 at a level 1 trauma center was performed. Demographics, AO/OTA fracture classification, quality of reduction, fixation constructs, and unplanned revision reoperation were compared between PDFF patients and NDFF patients using t-test and Fisher's exact test. 209 patients were identified with 70 patients having a PDFF and 139 patients having a NDFF. Of note, 48% of NDFF had a concomitant fracture of the ipsilateral knee (14%) or tibial plateau (15%). The most common AO/OTA classification for PDFFs was 33A3.3 (71%). NDFFs had two main AO/OTA classifications of 33C2.2 (28%) or 33A3.2. (25%). When controlling for patient age, bone quality, fracture classification, and fixation, the PDFF group had increased revision reoperation rate compared to NDFF (P < 0.05). PDFFs tend to occur in elderly patients with low bone quality, have complete metaphyseal comminution, and be isolated; whereas, NDFF tend to occur in younger patients, have less metaphyseal comminution, and be associated with other fractures. When controlling for variables, PDFF are at increased risk of unplanned revision reoperation. Surgeons should be aware of these increased risks in PDFFs and future research should focus on these unique fracture characteristics to improve outcomes


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 107 - 107
1 Nov 2018
Sheridan G Kelly R McDonnell S Kenny P
Full Access

This was a retrospective study of registry data from a National Orthopaedic Hospital for all THRs with 10-year follow-up data. Inclusion criteria were all THRs with a minimum of 10-year follow-up data. All metal-on-metal (MoM) THRs and MoM resurfacings were excluded from the analysis due to the high rate of revision associated with these bearings. Univariate and multivariate analyses controlling for confounding variables were performed to compare outcomes. A total of 1,697 THRs were performed in 1,553 patients. The four significant predictors for revision were fixation type (p<0.01), surface bearing type (p<0.01), age (P<0.05) and head size (p<0.05). Gender, BMI and approach had no effect on revision rates. The lowest 10-year all-cause revision rates were seen in cemented THRs at 1.7%. Ceramic-on-poly bearings had the lowest revision rate at only 1.2%. Metal-on-poly bearings had a 1.7% revision rate. Ceramic on ceramic bearings had a 7.1% revision rate with 1 revision for squeak and 1 revision for ceramic head fracture. The causes for revision in order of decreasing frequency were as follows: Infection (n=13, 0.7%), dislocation (n=7, 0.4%), periprosthetic fracture (n=3, 0.2%) and aseptic loosening (n=2, 0.1%). There were 2 re-revisions at 10 years in total. The smaller 22.225mm head sizes had a significantly lower revision rate than other head sizes (p<0.05). Ceramic-on-poly bearings, cemented fixation and smaller head sizes perform better in the experience of this registry. However, with multivariate analysis, these differences were shown to be insignificant


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 65 - 65
1 Dec 2021
Addai D Zarkos J Pettit M Kumar KHS Khanduja V
Full Access

Abstract. Objectives. Outcomes following different types of surgical intervention for FAI are well reported individually but comparative data is deficient. The purpose of this study was to conduct a systematic review (SR) and meta-analysis to analyse the outcomes following surgical management of FAI by hip arthroscopy (HA), anterior mini open approach (AMO) and surgical hip dislocation (SHD). Methods. This SR was registered with PROSPERO. An electronic database search of Pubmed, Medline and EMBASE for English and German language articles over the last 20 years was carried out according to the PRISMA guidelines. We specifically analysed and compared changes in patient reported outcome measures PROMs, α-angle, rate of complications, rate of revision and conversion to total hip arthroplasty (THA). Results. A total of 48 articles included for final analysis with a total of 4384 hips in 4094 patients. All subgroups showed a significant correction in mean alpha angle post-operatively with a mean change of 28.8° (95% CI, 21°-36.5°; p <0.01) after AMO, 21.1° (95% CI, 15.1°-27°; p <0.01) after SHD and 20.39° (95% CI, 15.66°-25.12°; p <0.01) after HA. AMO group showed a significantly higher increase in PROMs (3.7; 95% CI, 3.2–4.2; p <0.01) versus arthroscopy (2.47; 95% CI, 2.22–2.73; p <0.01) and SHD (2.4; 95% CI, 1.5–3.3; p <0.01). However, the rate of complications following AMO was significantly higher than HA and SHD. Conclusion. All three surgical approaches offered significant improvements in outcomes and radiological correction of cam deformities. All three groups showed similar rates of revision procedures and SHD had the highest rate of conversion to a THA. Revision rates was similar for all three revision procedures


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 72 - 72
1 Dec 2021
Komperla S Giles W Flatt E Gandhi MJ Eyre-Brook AE Jones V Papanna M Eves T Thyagarajan D
Full Access

Abstract. Shoulder replacements have evolved and current 4th generation implants allow intraoperative flexibility to perform anatomic, reverse, trauma, and revision shoulder arthroplasty. Despite high success rates with shoulder arthroplasty, complication rates high as 10–15% have been reported and progressive glenoid loosening remains a concern. Objectives. To report medium term outcomes following 4th generation VAIOS® shoulder replacement. Methods. We retrospectively analysed prospectively collected data following VAIOS® shoulder arthroplasty performed by the senior author between 2014–2020. This included anatomical (TSR), reverse(rTSR), revision and trauma shoulder replacements. The primary outcome was implant survival (Kaplan-Meier analysis). Secondary outcomes were Oxford Shoulder Scores (OSS), radiological outcomes and complications. Results. 172 patients met our inclusion criteria with 114 rTSR, 38 anatomical TSR, and 20 hemiarthroplasty. Reverse TSR- 55 primary, 31 revision, 28 for trauma. Primary rTSR- 0 revisions, average 3.35-year follow-up. Revision rTSR-1 revision (4.17%), average 3.52-year follow-up. Trauma rTSR- 1 revision (3.57%), average 4.56-year follow-up OSS: Average OSS improved from 15.39 to 33.8 (Primary rTSR) and from 15.11 to 29.1 (Revision rTSR). Trauma rTSR-Average post-operative OSS was 31.4 Anatomical TSR38 patients underwent primary anatomical TSR, 8 were revisions following hemiarthroplasty. In 16/38 patients, glenoid bone loss was addressed by bone grafting before implantation of the metal back glenoid component. Mean age at time of surgery was 68.3 years (53 – 81 years). Mean follow-up was 34 months (12 – 62 months). The average Oxford shoulder score improved from 14 (7–30) to 30 (9–48). There were 3 revisions (7.8%); two following subscapularis failure requiring revision conversion to reverse shoulder replacement and one for glenoid graft failure. Conclusions. The medium-term results of the VAIOS® system suggest much lower revision rates across multiple configurations of the system than previously reported, as well as a low incidence of scapular notching. This system allows conversion to rTSR during primary and revision surgery


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 71 - 71
1 Dec 2021
Giles W Komperla S Flatt E Gandhi M Eyre-Brook A Jones V Papanna M Eves T Thyagarajan D
Full Access

Abstract. Background/Objectives. The incidence of reverse total shoulder replacement (rTSR) implantation is increasing globally, but apprehension exists regarding complications and associated challenges. We retrospectively analysed the senior author's series of rTSR from a tertiary centre using the VAIOS shoulder system, a modular 4th generation implant. We hypothesised that the revision rTSR cohort would have less favourable outcomes and more complications. Methods. 114 patients underwent rTSR with the VAIOS system, over 7 years. The primary outcome was implant survival. Secondary outcomes were Oxford shoulder scores (OSS), radiographic analysis (scapular notching, tuberosity osteolysis, and periprosthetic radiolucent lines) and complications. Results. There were 55 Primary rTSR, 31 Revision rTSR and 28 Trauma rTSR. Implant survival: Primary rTSR- 0 revisions, average 3.35-year follow-up. Revision rTSR-1 revision (4.17%), average 3.52-year follow-up. Trauma rTSR- 1 revision (3.57%), average 4.56-year follow-up OSS: Average OSS improved from 15.39 to 33.8 (Primary rTSR) and from 15.11 to 29.1 (Revision rTSR). Average post-operative OSS for the Trauma rTSR was 31.4 Radiological analysis and complications: Low incidence of scapular notching One hairline fracture below the tip of stem, noted incidentally, which required no treatment. One periprosthetic fracture after alcohol related fall. Treated non-surgically One joint infection requiring two-stage revision to rTSR. One dislocation noted at 2 year follow up. This patient had undergone nerve grafting within 6 months of rTSR for axillary nerve injury sustained during the original fracture dislocation. One acromial fracture with tibial and distal humeral fracture after a fall. Conclusions. The 4th generation modular VAIOS implant is a reliable option for various indications. The revision rTSR cohort had favourable outcomes with low complication rates. In this series, early-to-medium term results suggest lower revision rates and good functional outcomes when compared to published reports. We plan to monitor long-term implant survivorship and patient reported outcomes. Declaration of Interest. (a) fully declare any financial or other potential conflict of interest


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 102 - 102
1 Nov 2018
Waddell J
Full Access

We have undertaken a series of clinical trials over the last 20 years to look at different bearing surface combinations in young adults. We continue to follow these patients well beyond the planned duration of the trials and new information is constantly becoming available. The first trial compared ceramic-on-ceramic with ceramic-on-standard-polyethylene. These patients have now been followed for 20 years with significant wear in the polyethylene group but virtually identical revision rates. The second trial ceramic-on-ceramic, cobalt-chrome-on-standard-polyethylene and cobalt-chrome-on-cross-linked-polyethylene. In this group the ceramic-on-ceramic patients have the lowest revision rate; the ceramic-on-polyethylene group demonstrates a lower wear rate than cobalt-chrome-on-polyethylene. The third trial looks at cobalt-chrome versus zirconium on either cross-linked polyethylene or conventional polyethylene. At 10 years there remains no evidence of improved performance from the zirconium surface as compared to cobalt-chrome. The cross-linked polyethylene group is clearly outperforming the conventional polyethylene in terms of wear rate but at 10 years the revision rates remain the same in all groups. Cross liked polyethylene appears to be the major determining factor in prosthetic longevity and appears to be more important than the counter face material