Aims. The amount of glenoid bone loss is an important factor in deciding between soft-tissue and bony reconstruction when managing anterior shoulder instability. Accurate and reproducible measurement of glenoid bone loss is therefore vital in evaluation of shoulder instability and recommending specific treatment. The aim of this systematic review is to identify the range methods and measurement techniques employed in clinical studies treating glenoid bone loss. Methods. A systematic review of the PubMed, MEDLINE, and Embase databases was undertaken to cover a ten-year period from February 2011 to February 2021. We identified clinical studies that incorporated bone loss assessment in the methodology as part of the decision-making in the management of patients with anterior shoulder instability. The Preferred
Classification systems for the reporting of surgical complications have been developed and adapted for many surgical subspecialties. The purpose of this systematic review was to examine the variability and frequency of reporting terms used to describe complications in ankle fracture fixation. We hypothesized that the terminology used would be highly variable and inconsistent, corroborating previous results that have suggested a need for standardized reporting terminology in orthopaedics. Ankle fracture outcome studies meeting predetermined inclusion and exclusion criteria were selected for analysis by two independent observers. Terms used to define adverse events were identified and recorded. If a difference occurred between the two observers, a third observer was enlisted. Results of both observers were compared. All terms were then compiled and assessed for variability and frequency of use throughout the studies involved.
Minimum clinically important differences (MCIDs) are critical to understanding changes in patient-reported outcome measure (PROM) scores after total joint arthroplasty (TJA). The usage and adoption of MCIDs not been well-studied. This study was performed to IDENTIFY trends in PROM and MCID use after TJA over the past decade. All articles published in the calendar years of 2010 and 2020 in CORR, JBJS, and the Journal of Arthroplasty were reviewed. Articles relating to clinical outcomes in primary total hip arthroplasty (THA) or total knee arthroplasty (TKA) were included. For each article, all reported PROMs and (if present) accompanying MCIDs were recorded. The use of PROMs and MCIDs were compared between articles published in 2010 and 2020.Abstract
Introduction
Methods
Specifically designed control interventions can account for expectation effects in clinical trials. For the interpretation of efficacy trials of physical, psychological, and self-management interventions for people living with pain, the design, conduct, and reporting of control interventions is crucial. To establish a quality standard in the field, core recommendations are presented alongside additional considerations and a reporting checklist for control interventions.Background
Objectives
Quality measures play a substantial role in the Centers for Medicare and Medicaid Services' hospital payment and public reporting programs. The purpose of this study was to assess whether public measurement of total hip and knee arthroplasty risk-standardized readmission (RSRRs) and complication rates (RSCRs) was temporally associated with decreasing rates of adverse outcomes among Medicare beneficiaries. We evaluated annual trends in hospital-level risk-standardized complication and readmission rates in the fiscal years 2010–11 and 2016–17 for patients undergoing hospital-based inpatient hip/knee replacement procedures. We calculated hospital-level rates using the same measures and methodology used in public reporting. We examined annual trends in the distribution of hospital-level outcomes through density plots (similar to histograms).Introduction
Methods
MRI scanning is the establish method of defining intra- and extra-articular diagnoses of patients with non-arthritic knee problems. Discrepancies in reporting have been noted in previous historic studies and anecdotally. The aim of this study was to analyse the reporting of intra-articular pathology and discrepancies in knee MRI reports by two clinician groups, consultant radiologists and consultant knee surgeons in a district hospital setting. A retrospective case-controlled cohort study was conducted using data collected from an outpatient physiotherapy-led knee clinic. Seventy-four patients in the cohort were referred for an MRI scan of their knee(s) following a clinical examination and history. MRI reports from both the consultant knee surgeon and the radiologist were entered into a database with other clinical details. Reports were analysed to determine number of diagnoses and degree of agreement. Each report was deemed to either completely agree, completely disagree or partially agree.Abstract
Introduction
Methods
Different techniques have been described to address massive bone loss of the acetabulum in revision hip surgery. aMace has gained popularity as it provides customization aiming to restore hip centre and provide good initial stability in cases of large non-contained defects. It takes into account quality of host bone. Its porous defect filling scaffold provides an excellent surface for osteointegration. Our aim was to assess the short and mid-term outcomes of patients who underwent revision surgery using aMace system. Ethical approval was obtained. A retrospective study included all patients who had aMace between June 2013 and October 2022 allowing for a minimum of 12-months follow-up. Patients’ demographics, indication, bone-loss severity, reconstruction details, re-operation, complications, mortality, pain and function were assessed. 52 cases were performed by 13 surgeons with median 51 months follow-up. Median age was 72.7 years. 86.5% were female. Average BMI was 25.3. Average ASA grade was 3. 65% were classified as Paprosky IIIB and 32% were IIIA. 73% were found to have poor bone quality on CT. Main indication for aMace was massive bone loss/discontinuity secondary to aseptic loosening in 88.5%. 77% underwent single-stage revision. 53.8% had 2 or more previous revisions. 71% underwent stem revision in the same setting. 77% received a dual mobility bearing. Re-operation rate was 5.7% for instability and femoral PPF. LLD was reported in 9.6%. Permanent Sciatic nerve palsy occurred in 3.8% of the cases. 30-days mortality was 1.9%. Statistically significant post-op improvements in pain and mobility were reported (p<0.001). None of the acetabular components have been revised. Our study shows satisfactory surgical outcomes with a relatively low complication rate and significant pain and mobility improvements in the early to mid-term stages. We recommend these costly cases to be done in highly specialist centres adopting MDT approach.
The histopathology of periprosthetic tissues has been important to understanding the relationship between wear debris and arthroplasty outcome. In a landmark 1977paper, Willert and Semlitsch (1) used a semiquantitative rating to show that tissue reactions largely reflected the extent of particulate debris. Notably, small amounts of debris, including metal, could be eliminated without “overstraining the tissues” but excess debris led to deleterious changes. Currently, a plethora of terms is used to describe tissues from metal-on-metal (M-M) hips and corroded modular connections. We reviewed the evaluation and reporting of local tissue reactions over time, and asked if a dose response has been found between metal and tissue features, and how the use of more standardized terms and quantitative methodologies could reduce the current confusion in terminology. The PubMed database was searchedbetween 2000 and 2015 for papers using “metal sensitivity /allergy /hypersensitivity, Adverse Local Tissue Reaction (ALTR): osteolysis, metallosis, lymphocytic infiltration, Aseptic Lymphocytic Vasculitis-Associated Lesions (ALVAL), Adverse Reaction to Metal Debris (ARMD) or pseudotumor/ pseudotumour” as well as metal-on-metal / metal-metal AND hip arthroplasty/replacement. Reports lacking soft tissue histological analysis were excluded. 131 articles describing M-M tissue histology were found. In earlier studies, the terms metal sensitivity / hypersensitivity /allergy implied or stated the potential for a Type IV delayed type hypersensitivity response as a reason for revision. More recently those terms have largely been replaced by broader terms such as ALTR, ALVAL and ARMD. ALVAL and metal hypersensitivity were often used interchangeably, both as failure modes and histological findings. Several histology scoring systems have been published but were only used in a limited number of studies. Correlations of histological features with metal levels or component wear were inconclusive, typically because of a high degree of variability. Interestingly, there were very few descriptions that concluded that the observed reactions were benign / normal or anticipated i.e. regardless of the histological features, extent of debris or failure mode, the histology was interpreted as showing an adverse reaction.Methods
Results
Review the complications reporting in 4 prominent spinal journals over the last decade. Computerised search of the Medline database and hand search was undertaken to evaluate the complication reporting in 4 spinal journals (Spine, European Spine Journal, Journal of Neurosurgery Spine and Journal of Bone and joint surgery) from 2000 to 2009. The articles were divided based on the level of NICE evidence classification A to D. A total of 88 articles reported spinal complications. Of these 5.9% was level B, 8.8% was level C and 85.3% was level D. There were no RCT's reported relating to complications (Level A) and majority of complications were case reports or expert opinions (level D). For the proportion of level D the rank order of the journals was; Spine (4.8%), European spine journal (3.8%), Journal of neurosurgery spine (5.1%) and Journal of bone and joint surgery was (1.8%). There was no increase in the rate of reporting over the decade. A detailed discussion of the reporting will be presented. Papers focusing primarily on complications and its management are still not the focus in most surgical journals. This review over the last 10 years confirms that only rare and uncommon complications are reported in the form of case reports. Meta analysis or case series of complication is rarely reported. More focus must be emphasised on reporting mortality and morbidity for education.
Low back pain is a very common complaint in medicolegal cases. However, and contrary to many other conditions, there are no objective medical exams that are able to help establish impairment rating. Testing the function of the trunk may, however, help back pain assessment. Many different principles of trunk function testing have been described.
Range of motion (ROM) Isometric strength measures Isokinetic strength testing Isoinertial strength and velocity measures Of all these techniques, isoinertial testing provides the closest simulation of natural movement and therefore seems the most appropriate for clinical trunk testing and assessment of spinal function. Functional assessment may enable a good estimation of remaining functional status and therefore permits a reasonable measure of the functional loss compared with age and sex matched databases. Nevertheless, for this measure to be reliable and valid one must be sure that the subject exerted a maximal performance: a maximal voluntary effort. Only then can the measured function be used to assess handicap. Different techniques have been elaborated to recognize maximal effort. The most accepted appears to be reliability (or reproducibility) of performance which postulates that impaired subjects will generate lower but reproducible performance. It has been well-validated in different areas of strength testing: hand grip, elbow flexors, knee extensors, shoulder press and posturography. In trunk testing, it has been established for isokinetic and isoinertial measures. A possible reliable submaximal performance has been shown to be possible in some specific conditions which are not usually found in low back pain sufferers. Furthermore, the measure of the coefficient of variance (CV), sometimes proposed, is not a reliable way to assess reproducibility of performance. The meaning of submaximal performance must be carefully understood, it may be the result of many factors like misunderstanding of instructions, fear of reinjury, anxiety, psychological distress and in some cases symptom amplification or malingering. The latter hypothesis can only rarely be determined with a reasonable degree of certainty. Instrumented function assessment can help to determine the degree of impairment in case of maximal effort. That is it’s major interest and use. A submaximal effort will not help to determine impairment but does not necessarily indicate a conscious attempt at symptom magnification or malingering, and requires further investigation. It cannot by itself inform the sincerity of the complainant. Functional assessment can be used to find a fair compensation in case of maximal effort. It cannot be used to chase so called “malingerers” if this effort is not realised. There is no such thing as a lie-detector of back function.
uni- or bilateral single level nerve root decompression Three month post-operative visual analogue scores (VAS, 10 = maximum pain, 0 = no pain) of less than 2 was required as an indicator that the pre-operative diagnosis had been correct (i.e. the surgery had significantly improved the patient’s pain). The MRI report of these patients was then scrutinised to see if the decompressed nerve root had been reported as significantly compressed on the pre-operative scan.
However, in this sample a large minority of MRIs had no formal report. Of those that were reported, there was underreporting of potential surgical targets by radiologists. This implies that there could be a high incidence of false negative MRI reporting with potentially treatable conditions being unrecognised.
The goals of perioperative management are to relieve pain, achieve early mobilization after surgery, reduce length of hospital stay, and obtain adequate patient satisfaction. Several treatment options combining systemic analgesics and/or regional analgesia with or without opioids are available for postoperative pain; however, a gold standard has not been established although there is a progressive shift towards multimodal approaches to improve analgesia while minimizing opioid-related side effects. EX-TRA-05 (DAVID-ART) was a randomised, double-blind, parallel, pivotal study, evaluating the analgesic efficacy and safety of the innovative oral combination of dexketoprofen/tramadol 25mg/75mg in comparison with the individual components (tramadol given at the higher dose of 100mg) on moderate to severe acute pain after total hip replacement. Repeated doses of study drug were administered every 8 hours and pain intensity (PI) was to be scored according to a 100mm visual analogue scale (VAS) on a programmed e-diary every 2 hours over a 56-hour period (i.e. along 7 repeated doses). A placebo arm was included at the first administration to validate the pain model. Rescue medication, metamizole 500mg, was available during the treatment period. The study primary endpoint was the mean sum of the pain intensity difference values throughout the first 8 hours (SPID8), which considered the 3 active treatment arms and placebo (ITT population; N=641). In this phase, a clear superiority of the combination over the single agents was demonstrated (p<0.05). An additional analysis was performed during the entire 0–56h repeated-dose period excluding those patients who had received placebo at the first dose (N=161). The estimated mean (SE) differences on PI-VAS over 24, 32 and 56 hours post first dose (0–24h, 0–32h, and 0–56h) between the combination and each single agent were evaluated. Patients who received active analgesic from the first dose (mITT population; N=480) were aged 29–80 years (42% were ≥65 years). At randomisation, pain was moderate (≥40–60mm) in 51% patients and severe (>60mm) in 49%. For dexketoprofen/tramadol, mean (SD) PI-VAS values were 22 (4.0) over 24 hours; 21 (4.1) over 32 hours; and 19 (3.8) over 56 hours. The estimated differences versus dexketoprofen 25mg and tramadol 100mg were respectively 10 (0.7) and 7.6 (0.7) over 24 hours; 9.8 (0.6) and 7.2 (0.6) over 32 hours; and 8.1 (0.5) and 6.3 (0.5) over 56 hours (p<0.0001 for all comparisons), which confirmed the superiority of the combination versus both single agents throughout the periods analysed. This significant higher decrease of PI favouring dexketoprofen/tramadol 25mg/75mg over dexketoprofen 25mg and tramadol 100mg, all given every 8 hours, during the first 56 hours post dose confirmed the superior analgesia shown after the first 0–8h post-dose period. The combination of dexketoprofen/tramadol 25mg/75mg is able to provide a level of analgesia above that achievable by each component alone, with a sustained effect when used as a multiple-dose regimen. The addition of this new combo to the analgesic armamentarium may contribute to facilitate early mobilization after surgery, thus positively impacting perioperative co-morbidities and length of in-hospital stay.
To promote cultural awareness and acceptance of clinical governance by developing a simple, reproducible model for reporting critical incidents and near misses within our department. An A4 sized departmental proforma was developed to parallel the Trust’s official adverse incident register. Prospective reporting of adverse events using the proforma was encouraged between August 2000 and June 2001. Incidents were discussed in an anonymised and a blame-free setting, at the monthly multidisciplinary clinical governance meeting and appropriate action taken. In the 6 months prior to commencing this study only 4 adverse events were reported with no discernible action taken. Following the introduction of the proforma 61 critical incidents and near misses were reported in the period August 2000 to June 2001. As a result of effective reporting of adverse events we have developed a number of protocols to improve patient care. A simple model for reporting critical incidents and near misses has been established. This has fostered a cultural change within the department and all members of staff feel more comfortable with reporting such incidents. The process is seen as educational and an important part of continuing professional and departmental development. Protocols and changes in organisational practice have been developed to reduce and prevent the occurrence of adverse events and offer our patients continuous improvement in care.
The purpose of this study was to show the feasibility of setting up a computerized register of complications for a whole Department of Orthopaedic Surgery and Traumatology, based on a simple, user-friendly and upto-date scientific approach.
The Ionising Radiation (Medical Exposure) Regulations 2000 is concerned with: “the making of safety measures in regard to radioactive substances and the emission of ionising radiation”. Responsibility is placed upon the Practitioner, Operator, Referrer and employer. A clinical evaluation of the outcome of each medical exposure must be recorded.” In Ayr Hospital Radiologist report A&E radiographs but not those in fracture clinic unless a specific request was made. Therefore the Surgeon/Trainee must record their interpretation. An audit was completed to review the rate of documentation of the interpretation of radiographs in the clinical records of consecutive patients attending fracture clinics Notes and radiographs were reviewed from 6 separate fracture clinics. 106 patients attended during the time period and were seen by 9 different surgeons; 5 consultants and 4 training grade surgeons. 46 out of 106 patients were x-rayed and interpretation recorded in 38 cases. No interpretation was found in 8 cases, giving an overall compliance of 82.6% with no difference between different grades of surgeon: Consultants 79.2% (19/24); Trainees 86.4% (19/22). These finding were presented at a departmental audit meeting and the audit loop was then closed by a second period of audit with an improvement in the consultants compliance to 100% (22/22) p=0.05 and no significant change in the trainees performance 75% (18/24).
We performed a systematic review of the literature
to evaluate the use and interpretation of generic and disease-specific
functional outcome instruments in the reporting of outcome after
the surgical treatment of disruptions of the pelvic ring. A total
of 28 papers met our inclusion criteria, with eight reporting only
generic outcome instruments, 13 reporting only pelvis-specific outcome
instruments, and six reporting both. The Short-Form 36 (SF-36) was
by far the most commonly used generic outcome instrument, used in
12 papers, with widely variable reporting of scores. The pelvis-specific
outcome instruments were used in 19 studies; the Majeed score in
ten, Iowa pelvic score in six, Hannover pelvic score in two and
the Orlando pelvic score in one. Four sets of authors, all testing construct
validity based on correlation with the SF-36, performed psychometric
testing of three pelvis-specific instruments (Majeed, IPS and Orlando
scores). No testing of responsiveness, content validity, criterion
validity, internal consistency or reproducibility was performed. The existing literature in this area is inadequate to inform
surgeons or patients in a meaningful way about the functional outcomes
of these fractures after fixation.