Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 2 - 2
10 May 2024
Chen W Tay ML Bolam S Rosser K Monk AP Young SW
Full Access

Introduction. A key outcome measured by national joint registries are revision events. This informs best practice and identifies poor-performing surgical devices. Although registry data often record reasons for revision arthroplasty, interpretation is limited by lack of standardised definitions of revision reasons and objective assessment of radiologic and laboratory parameters. Our study aim was to compare reasons for unicompartmental knee arthroplasty (UKA) revision reported to the New Zealand Joint Registry (NZJR) with reasons identified by independent clinical review. Methods. A total of 2,272 patients undergoing primary medial and lateral UKA at four large tertiary hospitals between 2000 and 2017 were included. A total of 158 patients underwent subsequent revision with mean follow-up of 8 years. A systematic review of clinical findings, radiographs and operative data was performed to identify revision cases and to determine the reasons for revision using a standardised protocol. These were compared to reasons reported to the NZJR using Chi-squared and Fisher exact tests. Results. Osteoarthritis progression was the most common reason for revision on systematic clinical review (30%), however this was underreported to the registry (4%, p<0.001). A larger proportion of revisions reported to the registry were for ‘unexplained pain’ (30% of cases vs. 4% on clinical review, p<0.001). A reason for revision was not reported to the registry for 24 (15%) of cases. Discussion and Conclusion. We found significant inaccuracies in registry-reported reasons for revision following UKA. These included over-reporting of ‘unexplained pain’, under-reporting of osteoarthritis progression, and failure to identify a reason for revision. Efforts to improve registry capture of revision reasons for UKA should focus on increasing accuracy in these three areas. This could be addressed through standardised recording methods and tailored revision reason options for UKA for surgeons to select when recording the reasons


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 85 - 85
7 Nov 2023
Arakkal A Daoub M Nortje M Hilton T Le Roux J Held M
Full Access

The aim of this retrospective cohort study was to investigate the reasons for total knee arthroplasty (TKA) revisions at a tertiary hospital over a four-year period. The study aimed to identify the primary causes of TKA revisions and shed light on the implications for patient care and outcomes. The study included 31 patients who underwent revisions after primary knee arthroplasty between January 2017 and December 2020. A retrospective approach was employed, utilizing medical records and radiological findings to identify the reasons for TKA revisions. The study excluded oncology patients to focus on non-oncologic indications for revision surgeries. Patient demographics, including age and gender, were recorded. Data analysis involved categorizing the reasons for revision based on clinical assessments and radiological evidence. Among the 31 patients included in the study, 9 were males and 22 were females. The age of the patients ranged from 43 to 81, with a median age of 65 and an interquartile range of 18.5. The primary reasons for TKA revisions were identified as aseptic loosening (10 cases) and prosthetic joint infection (PJI) (13 cases). Additional reasons included revision from surgitech hemicap (1 case), patella osteoarthritis (1 case), stiffness (2 cases), patella maltracking (2 cases), periprosthetic fracture (1 case), and patella resurfacing (1 case). The findings of this retrospective cohort study highlight aseptic loosening and PJI as the leading causes of TKA revisions in the examined patient population. These results emphasize the importance of optimizing surgical techniques, implant selection, and infection control measures to reduce the incidence of TKA revisions. Future research efforts should focus on preventive strategies to enhance patient outcomes and mitigate the need for revision surgeries in TKA procedures


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 12 - 12
10 Feb 2023
Boyle A Zhu M Frampton C Poutawera V Vane A
Full Access

Multiple joint registries have reported better implant survival for patients aged >75 years undergoing total hip arthroplasty (THA) with cemented implant combinations when compared to hybrid or uncemented implant combinations. However, there is considerable variation within these broad implant categories, and it has therefore been suggested that specific implant combinations should be compared. We analysed the most common contemporary uncemented (Corail/Pinnacle), hybrid (Exeter V40/Trident) and cemented (Exeter V40/Exeter X3) implant combinations in the New Zealand Joint Registry (NZJR) for patients aged >75 years. All THAs performed using the selected implants in the NZJR for patients aged >75 years between 1999 and 2018 were included. Demographic data, implant type, and outcome data including implant survival, reason for revision, and post-operative Oxford Hip Scores were obtained from the NZJR, and detailed survival analyses were performed. Primary outcome was revision for any reason. Reason for revision, including femoral or acetabular failure, and time to revision were recorded. 5427 THAs were included. There were 1105 implantations in the uncemented implant combination group, 3040 in the hybrid implant combination group and 1282 in the cemented implant combination group. Patient reported outcomes were comparable across all groups. Revision rates were comparable between the cemented implant combination (0.31 revisions/100 component years) and the hybrid implant combination (0.40 revisions/100 component years) but were statistically significantly higher in the uncemented implant combination (0.80/100 component years). Femoral-sided revisions were significantly greater in the uncemented implant combination group. The cemented implant and hybrid implant combinations provide equivalent survival and functional outcomes in patients aged over 75 years. Caution is advised if considering use of the uncemented implant combination in this age group, predominantly due to a higher risk of femoral sided revisions. The authors recommend comparison of individual implants rather than broad categories of implants


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 78 - 78
10 Feb 2023
Hannah A Henley E Frampton C Hooper G
Full Access

This study aimed to examine the changing trends in the reasons for total hip replacement (THR) revision surgery, in one country over a twenty-one year period, in order to assess whether changes in arthroplasty practices have impacted revision patterns and whether an awareness of these changes can be used to guide clinical practice and reduce future revision rates. The reason for revision THR performed between January 1999 and December 2019 was extracted from the New Zealand Joint Registry (NZJR). The results were then grouped into seven 3-year periods to allow for clearer visualization of trends. The reasons were compared across the seven time periods and trends in prosthesis use, patient age, gender, BMI and ASA grade were also reviewed. We compared the reasons for early revision, within one year, with the overall revision rates. There were 20,740 revision THR registered of which 7665 were revisions of hips with the index procedure registered during the 21 year period. There has been a statistically significant increase in both femoral fracture (4.1 – 14.9%, p<0.001) and pain (8.1 – 14.9%, p<0.001) as a reason for hip revision. While dislocation has significantly decreased from 57.6% to 17.1% (p<0.001). Deep infection decreased over the first 15 years but has subsequently seen further increases over the last 6 years. Conversely both femoral and acetabular loosening increased over the first 12 years but have subsequently decreased over the last 9 years. The rate of early revisions rose from 0.86% to 1.30% of all revision procedures, with a significant rise in revision for deep infection (13-33% of all causes, p<0.001) and femoral fracture (4-18%, p<0.001), whereas revision for dislocation decreased (59-30%, p<0.001). Adjusting for age and gender femoral fracture and deep infection rates remained significant for both (p<0.05). Adjusting for age, gender and ASA was only significant for infection. The most troubling finding was the increased rate of deep infection in revision THR, with no obvious linked pattern, whereas, the reduction in revision for dislocation, aseptic femoral and acetabular loosening can be linked to the changing patterns of the use of larger femoral heads and improved bearing surfaces


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 95 - 95
10 Feb 2023
Mowbray J Frampton C Maxwell R Hooper G
Full Access

Cementless fixation is an alternative to cemented unicompartmental knee replacement (UKR), with several advantages over cementation. This study reports on the 15-year survival and 10-year clinical outcomes of the cementless Oxford unicompartmental knee replacement (OUKR). This prospective study describes the clinical outcomes and survival of first 693 consecutive cementless medial OUKRs implanted in New Zealand. The sixteen-year survival was 89.2%, with forty-six knees being revised. The commonest reason for revision was progression of arthritis, which occurred in twenty-three knees, followed by primary dislocation of the bearing, which occurred in nine knees. There were two bearing dislocations secondary to trauma and a ruptured ACL, and two tibial plateau fractures. There were four revisions for polyethylene wear. There were four revisions for aseptic tibial loosening, and one revision for impingement secondary to overhang of the tibial component. There was only one revision for deep infection and one revision where the indication was not stated. The mean OKS improved from 23.3 (7.4 SD) to 40.59 (SD 6.8) at a mean follow-up of sixteen years. In conclusion, the cementless OUKR is a safe and reproducible procedure with excellent sixteen-year survival and clinical outcomes


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 11 - 11
23 Feb 2023
Hardwick-Morris M Twiggs J Miles B Walter WL
Full Access

Iliopsoas tendonitis occurs in up to 30% of patients after hip resurfacing arthroplasty (HRA) and is a common reason for revision. The primary purpose of this study was to validate our novel computational model for quantifying iliopsoas impingement in HRA patients using a case-controlled investigation. Secondary purpose was to compare these results with previously measured THA patients. We conducted a retrospective search in an experienced surgeon's database for HRA patients with iliopsoas tendonitis, confirmed via the active hip flexion test in supine, and control patients without iliopsoas tendonitis, resulting in two cohorts of 12 patients. The CT scans were segmented, landmarked, and used to simulate the iliopsoas impingement in supine and standing pelvic positions. Three discrete impingement values were output for each pelvic position, and the mean and maximum of these values were reported. Cup prominence was measured using a novel, nearest-neighbour algorithm. The mean cup prominence for the symptomatic cohort was 10.7mm and 5.1mm for the asymptomatic cohort (p << 0.01). The average standing mean impingement for the symptomatic cohort was 0.1mm and 0.0mm for the asymptomatic cohort (p << 0.01). The average standing maximum impingement for the symptomatic cohort was 0.2mm and 0.0mm for the asymptomatic cohort (p << 0.01). Impingement significantly predicted the probability of pain in logistic regression models and the simulation had a sensitivity of 92%, specificity of 91%, and an AUC ROC curve of 0.95. Using a case-controlled investigation, we demonstrated that our novel simulation could detect iliopsoas impingement and differentiate between the symptomatic and asymptomatic cohorts. Interestingly, the HRA patients demonstrated less impingement than the THA patients, despite greater cup prominence. In conclusion, this tool has the potential to be used preoperatively, to guide decisions about optimal cup placement, and postoperatively, to assist in the diagnosis of iliopsoas tendonitis


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 21 - 21
23 Feb 2023
Sandow M Page R Hatton A Peng Y
Full Access

The 2021 Australian Orthopaedic Association National Joint Replacement Registry report indicated that total shoulder replacement using both mid head (TMH) length humeral components and reverse arthroplasty (RTSA) had a lower revision rate than stemmed humeral components in anatomical total shoulder arthroplasty (aTSA) - for all prosthesis types and diagnoses. The aim of this study was to assess the impact of component variables in the various primary total arthroplasty alternatives for osteoarthritis in the shoulder. Data from a large national arthroplasty registry were analysed for the period April 2004 to December 2020. The study population included all primary aTSA, RTSA, and TMH shoulder arthroplasty procedures undertaken for osteoarthritis (OA) using either cross-linked polyethylene (XLPE) or non-cross-linked polyethylene (non XLPE). Due to the previously documented and reported higher revision rate compared to other anatomical total shoulder replacement options, those using a cementless metal backed glenoid components were excluded. The rate of revision was determined by Kaplan-Meir estimates, with comparisons by Cox proportional hazard models. Reasons for revision were also assessed. For a primary diagnosis of OA, aTSA with a cemented XLPE glenoid component had the lowest revision rate with a 12-year cumulative revision rate of 4.7%, compared to aTSA with cemented non-XLPE glenoid component of 8.7%, and RTSA of 6.8%. The revision rate for TMH was lower than aTSA with cemented non-XLPE, but was similar to the other implants at the same length of follow-up. The reason for revision for cemented aTSR was most commonly component loosening, not rotator cuff deficiency. Long stem humeral components matched with XLPE in aTSA achieve a lower revision rate compared to shorter stems, long stems with conventional polyethylene, and RTSA when used to treat shoulder OA. In all these cohorts, loosening, not rotator cuff failure was the most common diagnosis for revision


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 1 - 1
10 May 2024
Scherf E Willis J Frampton C Hooper G
Full Access

Introduction. The mobile-bearing (MB) total knee arthroplasty (TKA) design was introduced with the aim of reducing polyethylene wear and component loosening seen in the fixed-bearing (FB) design. A recent joint registry study has revealed increased risk for all-cause revision, but not revision for infection, in MB-TKA. We used the New Zealand Joint Registry (NZJR) to compare all-cause revision rates, and revision rates for aseptic loosening of MB-TKA compared with fixed bearing (FB) TKA. Methods. All patients who underwent a primary TKA registered in the NZJR between the 1st January 1999 to 31st December 2021 were identified. Analysis compared MB to FB designs, with sub analysis of implants from a single company. We identified 135,707 primary TKAs, with 104,074 (76.7%) FB-TKAs and 31,633 (23.3%) MB-TKAs recorded. We examined all-cause revision rates, reasons for revision and performed survival analyses. Results. For all-comers, MB-TKA had an all-cause revision rate of 0.43/100-component-years (OCY) compared with 0.42/OCY for FB-TKA (p=0.09). The all-cause revision rate was higher for those age < 65 years (MB TKA 0.60/OCY vs. FB-TKA 0.59/OCY) compared to those > 65 years at time of primary TKA (MB-TKA 0.29/OCY vs. FB-TKA 0.32/OCY), however there was no statistically significant difference between implant design in either age group (p=0.16 and p=0.64; respectively). Similarly, there was no difference in revision rates for aseptic loosening between implant designs. Kaplan-Meier survival analysis demonstrates no statistically significant difference in revision-free survival of implants, with both MB-TKA and FB-TKA demonstrating ∼93% revision free survival at 23 years. Conclusions. Both FB- and MB-TKA demonstrated excellent survivorship, with no significant difference in all-cause revision rates or revision for aseptic loosening between implant designs


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 40 - 40
10 Feb 2023
Tse C Mandler S Crawford H Field A
Full Access

The purpose of this study is to evaluate risk factors for distal construct failure (DCF) in posterior spinal instrumented fusion (PSIF) in adolescent idiopathic scoliosis (AIS). We observed an increased rate of DCF when the pedicle screw in the lowest instrumented vertebra (LIV) was not parallel to the superior endplate of the LIV, however this has not been well studied in the literature. We hypothesise a more inferiorly angled LIV screw predisposes to failure and aim to find the critical angle that predisposes to failure. A retrospective cohort study was performed on all patients who underwent PSIF for AIS at the Starship Hospital spine unit from 2010 to 2020. On a lateral radiograph, the angle between the superior endplate of the LIV was measured against its pedicle screw trajectory. Data on demographics, Cobb angle, Lenke classification, instrumentation density, rod protrusion from the most inferior screw, implants and reasons for revision were collected. Of 256 patients, 10.9% (28) required at least one revision. The rate of DCF was 4.6% of all cases (12 of 260) and 25.7% of revisions were due to DCF. The mean trajectory angle of DCF patients compared to all others was 13.3° (95%CI 9.2° to 17.4°) vs 7.6° (7° to 8.2°), p=0.0002. The critical angle established is 11°, p=0.0076. Lenke 5 and C curves, lower preoperative Cobb angle, titanium only rod constructs and one surgeon had higher failure rates than their counterparts. 9.6% of rods protruding less than 3mm from its distal screw disengaged. We conclude excessive inferior trajectory of the LIV screw increases the rate of DCF and a screw trajectory greater than 11° predisposes to failure. This is one factor that can be controlled by the surgeon intraoperatively and by avoiding malposition of the LIV screw, a quarter of revisions can potentially be eliminated


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 40 - 40
1 Dec 2022
Schmidt-Braekling T Thavorn K Poitras S Gofton W Kim P Beaulé P Grammatopoulos G
Full Access

With an ageing population and an increasing number of primary arthroplasties performed, the revision burden is predicted to increase. The aims of this study were to 1. Determine the revision burden in an academic hospital over a 11-year period; 2. identify the direct hospital cost associated with the delivery of revision service and 3. ascertain factors associated with increased cost. This is an IRB-approved, retrospective, single tertiary referral center, consecutive case series. Using the hospital data warehouse, all patients that underwent revision hip or knee arthroplasty surgery between 2008-2018 were identified. 1632 revisions were identified (1304 patients), consisting of 1061 hip and 571 knee revisions. The majority of revisions were performed for mechanical-related problems and aseptic loosening (n=903; 55.3%); followed by periprosthetic joint infection (n=553; 33.9%) and periprosthetic fractures (176; 10.8%). Cost and length of stay was determined for all patient. The direct in-hospital costs were converted to 2020 inflation-adjusted Canadian dollars. Several patients- (age; gender; HOMR- and ASA-scores; Hemoglobin level) and surgical- (indication for surgery; surgical site) factors were tested for possible associations. The number of revisions increased by 210% in the study period (2008 vs. 2018: 83 vs. 174). Revision indications changed over study period; with prevalence of fracture increasing by 460% (5 in 2008 vs. 23 in 2018) with an accompanying reduction in mechanical-related reasons, whilst revisions for infection remained constant. The mean annual cost over the entire study period was 3.9 MMCAD (range:2.4–5.1 MMCAD). The cost raised 150% over the study period from 2.4 MMCAD in 2008 to 3.6 MMCAD. Revisions for fractured had the greatest length of stay, the highest mean age, HOMR-score, ASA and cost associated with treatment compared to other revision indications (p < 0 .001). Patient factors associated with cost and length of stay included ASA- and HOMR-scores, Charlson-Comorbidity score and age. The revision burden increased 1.5-fold over the years and so has the direct cost of care delivery. The increased cost is primarily related to the prolonged hospital stay and increased surgical cost. For tertiary care units, these findings indicate a need to identify strategies on improving efficiencies whilst improving the quality of patient care (e.g. efficient ways of reducing acute hospital stay) and reducing the raise of the economic burden on a publicly funded health system


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 42 - 42
1 Dec 2022
Fransen B Howard L MacDonell T Bengoa F Garbuz D Sheridan G Neufeld M
Full Access

Increased femoral head size reduces the rate of dislocation after total hip arthroplasty (THA). With the introduction of highly crosslinked polyethylene (HXLPE) liners in THA there has been a trend towards using larger size femoral heads in relatively smaller cup sizes, theoretically increasing the risk of liner fracture, wear, or aseptic loosening. Short to medium follow-up studies have not demonstrated a negative effect of using thinner HXLPE liners. However, there is concern that these thinner liners may prematurely fail in the long-term, especially in those with thinner liners. The aim of this study was to evaluate the long-term survival and revision rates of HXLPE liners in primary THA, as well as the effect of liner thickness on these outcomes. We hypothesized that there would be no significant differences between the different liner thicknesses. We performed a retrospective database analysis from a single center of all primary total hip replacements using HXLPE liners from 2010 and earlier, including all femoral head sizes. All procedures were performed by fellowship trained arthroplasty surgeons. Patient characteristics, implant details including liner thickness, death, and revisions (all causes) were recorded. Patients were grouped for analysis for each millimeter of PE thickness (e.g. 4.0-4.9mm, 5.0-5.9mm). Kaplan-Meier survival estimates were estimated with all-cause and aseptic revisions as the endpoints. A total of 2354 patients (2584 hips) were included (mean age 64.3 years, min-max 19-96). Mean BMI was 29.0 and 47.6% was female. Mean follow-up was 13.2 years (range 11.0-18.8). Liner thickness varied from 4.9 to 12.7 mm. Seven patients had a liner thickness <5.0mm and 859 had a liner thickness of <6.0mm. Head sizes were 28mm (n=85, 3.3%), 32mm (n=1214, 47.0%), 36mm (n=1176, 45.5%), and 40mm (n=109, 4.2%), and 98.4% were metal heads. There were 101 revisions, and in 78 of these cases the liner was revised. Reason for revision was instability/dislocation (n=34), pseudotumor/aseptic lymphocyte-dominant vasculitis associated lesion (n=18), fracture (n=17), early loosening (n=11), infection (n=7), aseptic loosening (n=4), and other (n=10). When grouped by liner thickness, there were no significant differences between the groups when looking at all-cause revision (p=0.112) or aseptic revision (p=0.116). In our cohort, there were no significant differences in all-cause or aseptic revisions between any of the liner thickness groups at long-term follow-up. Our results indicate that using thinner HXPE liners to maximize femoral head size in THA does not lead to increased complications or liner failures at medium to long term follow-up. As such, orthopedic surgeons can consider the use of larger heads at the cost of liner thickness a safe practice to reduce the risk of dislocation after THA when using HXLPE liners


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 68 - 68
1 Oct 2022
Bos K Spekenbrink-Spooren A Reijman M Bierma-Zeinstra S Croughs P v. Oldenrijk J
Full Access

Aim. Aim was to compare revision rates when using single versus dual antibiotic loaded cement (ABLC) in hip fracture arthroplasty and aseptic revision hip or knee arthroplasty using data from the Dutch national joint registry (LROI). Methods. All primary cemented (hemi-)arthroplasties for acute hip fractures and cemented aseptic hip or knee revision arthroplasties, were incorporated in 3 datasets. All registered implants between 2007 and 2018 were included (minimum 2 years follow-up). Primary end-point was subsequent revision rates for infection and for any reason in the single and dual ABLC groups. Cumulative crude incidence of revision was calculated using competing risk analysis. Results. A total of 22,308 hip fracture arthroplasties, 2,529 hip revision and 7,124 knee revision arthroplasties were registered and analyzed in the study period. The majority of hip fracture patients (97.1%) was treated with single ABLC. For hip and knee revision arthroplasties dual ABLC was used in 33.8% and 25.7%. The revision rate for infection in the fracture arthroplasty group was not different between groups (0.5% versus 0.8%, p=0.27). The re-revision rate following hip or knee revision based on single versus dual ABLC was not different between groups (3.2% versus 2.8%, p=0.82 for hip revision and 1.8% versus 2.5%, p=0.36 for knee revision). In addition, the re-revision rate for any reason was not different in all three datasets. The crude cumulative revision and re-revision rates for any reason based on single ABLC versus dual ABLC showed no differences in all three datasets. The crude cumulative 7-year re-revision rate for any reason following revision THA with Gentamicin ABLC use was 11.8%, with Gentamicin + Clindamycin ABLC use 13.1% and with Erythromycin + Colistin ABLC use 14.8% (ns). The crude cumulative 9-year re-revision rate for any reason following revision TKA with Gentamicin ABLC use was 17.7% and with Gentamicin + Clindamycin ABLC use 16.5% (ns). Conclusions. In conclusion, we could not show a difference in revision rate for hip fracture arthroplasty or re-revision rates for revision hip- or knee arthroplasty with the use of dual ABLC compared to single ABLC bone cement, with 7and 9 year follow up. The low percentage of dual ABLC in hip fracture arthroplasties in our registry do not enable us to make a reliable estimation of the added value in this patient category. The results of this study do not confirm the potential benefit of dual ABLC use in revision cases


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 25 - 25
1 Feb 2021
Cascardo C Gehrke C Moore D Karadsheh M Flierl M Baker E
Full Access

Introduction. Dual mobility (DM) total hip arthroplasty (THA) prostheses are designed to increase stability. In the setting of primary and revision THA, DM THA are used most frequently for dysplasia and instability diagnoses, respectively. As the use of DM THA continues to increase, with 8,031 cases logged in the American Joint Replacement Registry from 2012–2018, characterizing in vivo damage and clinical failure modes are important to report. Methods. Under IRB-approved implant retrieval protocol, 43 DM THA systems from 41 patients were included. Each DM THA component was macroscopically examined for standard damage modes. Clinically-relevant data, including patient demographics and surgical elements, were collected from medical records. Fretting and corrosion damage grading is planned, according to the Goldberg et al. classification system. Results. In this 43-retrieved implant series, there were 23 female and 17 male patients (n=1, unknown), with an average body mass index of 29 (range, 19–49), and average ages at index and revision of 63 years (range, 34–80) and 64 years (range, 38–88), respectively. The average duration of implantation was 12.9 months (range, 0.1–72.0). Reasons for revision included infection (n=11, 26%), mechanical complication (n=10, 23%), intraprosthetic dislocation (n=6, 14%), periprosthetic fracture (n=5, 12%), pain (n=4, 9%), acetabular-associated loosening (n=3, 7%), unknown (n=3, 7%), hematoma (n=2, 5%), leg length discrepancy (n=1, 2%), and inflammatory reaction (n=1, 2%); some cases included multiple reasons for revision. On articular surfaces, scratching was the most commonly observed damage mode on all components, with more than 40% of acetabular cup and femoral heads showing scratching damage (Figure 1A). Abrasion, burnishing, and pitting damage were also observed in more than 10% of acetabular cup and acetabular liner components; further, approximately 20% of polyethylene acetabular liners exhibited edge deformation damage. On backside surfaces, polyethylene acetabular liners showed the greatest damage, with more than 60% of components exhibiting abrasion, scratching, or pitting damage (Figure 1B). Conclusion. This series showed various reasons for revision as well as in vivo damage of retrieved DM systems following short-to-midterm implantation. Damage was observed on both articular and backside surfaces of the five components of DM THA. Modularity of DM THA prostheses may amplify rates of in vivo damage. Future studies are needed to confirm these results and clinical significance. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 8 - 8
1 Dec 2021
Kamp MC van der Weegen W Liu W Goosen J( Rijnen W
Full Access

Aim. National Joint Replacement Registries, which are important sources for periprosthetic joint infection (PJI) data, report an average PJI incidence ranging from 0.5 to 2.0%. Unfortunately, national registries including the Dutch Arthroplasty Register (LROI), are not specifically designed to register PJI. In the Netherlands, the LROI is a nationwide population-based registry with an overall completeness of more than 95%. 3. To ensure usability and reliability of PJI data from the LROI, it is important to evaluate the quality and completeness of these data. From 2013 onwards, eight hospitals in the South-East of the Netherlands, collected their PJI data in a detailed regional infection cohort (RIC), specifically designed for this purpose. This study aimed to determine the accuracy and completeness of PJI registration (hip and knee arthroplasty) in the LROI, by comparing the LROI with the RIC. Method. All patients registered with an acute PJI in the RIC between 2014–2018 were selected for the study and were matched with the LROI. According to the Workgroup of American Musculoskeletal Infections Society (MSIS), an acute PJI was defined as at least two phenotypically identical pathogens, isolated in cultures from at least two separate tissues, obtained from the affected peri-prosthetic tissue during the DAIR treatment (debridement, antibiotics, irrigation, and retention). Only PJI occurring within 90 days after primary hip or knee arthroplasty were included. The LROI data and completeness was based on the entered procedures and documented reason for revision infection, which was not specially based on the MSIS criteria. After checks on missing and incorrectly data, the completeness of registration in the LROI was calculated by comparing the number of registrations in the LROI with data from the RIC (gold standard). Results. Of the 639 primary total hip and knee arthroplasty with a suspected PJI registered in the RIC between 2014–2018, 352 cases met the definition of acute PJI. The overall incidence was 1%. When compared with the LROI, 164 of these cases were also registered in the LROI as PJI revision, resulting in a 53% underestimation of PJI for the LROI. Conclusions. LROI data on acute PJI shows a significant underestimation, which is comparable to scarce other literature sources. To ensure reliability and usability of national PJI data, a specifically part of the LROI has to be designed for registering PJI similar to the regional cohort


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 91 - 91
1 Feb 2020
Baral E Purcel R Wright T Westrich G
Full Access

Introduction. Long term data on the survivorship of cemented total knee arthroplasty (TKA) has demonstrated excellent outcomes; however, with younger, more active patients, surgeons have a renewed interest in improved biologic fixation obtained from highly porous, cementless implants. Early designs of cementless total knees systems were fraught with high rates of failure for aseptic loosening, particularly on the tibial component. Prior studies have assessed the bone ingrowth extent for tibial tray designs reporting near 30% extent of bone ingrowth . (1,2). While these analyses were performed on implants that demonstrated unacceptably high rates of clinical failure, a paucity of data exists on the extent on bone ingrowth in contemporary implant designs with newer methods for manufacturing the porous surfaces. We sought to evaluate the extent of attached bone on retrieved cementless tibial trays to determine if patient demographics, device factors, or radiographic results correlate to the extent of bone ingrowth in these contemporary designs. Methods. Using our IRB approved retrieval database, 17 porous tibial trays were identified and separated into groups based on manufacturer: Zimmer Natural Knee (1), Zimmer NexGen (10), Stryker Triathlon (4) and Biomet Vanguard Regenerex (2). Differences in manufacturing methods for porous material designs were recorded. Patient demographics and reason for revision are described in Table 1. Radiographs were used to measure tibiofemoral alignment and the tibial mechanical axis alignment. Components were assessed using visual light microscopy and Photoshop to map bone ingrowth extent across the porous surface. ImageJ was used to threshold and calculate values for bone, scratched metal, and available surface for bone ingrowth (Fig. 1). Percent extent was determined as the bone ingrowth compared to the surface area excluding any scratched regions from explantation. Statistics were performed among tray designs as well as between the lateral and medial pegs, if designs had pegs available for bony ingrowth. Results. Mean bone ingrowth extent was 51.4% for the tibial tray for the entire cohort. Bone ingrowth extent was statistically greater in the Zimmer NexGen design (63.8%; p=.027) compared to the other three designs (Table 2). Four sets of pegs were excluded from analysis due to lack of porous coatings or pegs having been removed at revision surgery. Across all designs, the medial peg had 45.2% ingrowth and the lateral peg had 66.1% ingrowth. The medial peg for the NexGen design had significantly less bone ingrowth compared to the lateral peg (58.7% vs. 75.4%; p=0.044). No significant differences were found in tibiofemoral alignment or tibial mechanical axis alignment between the implant groups. No significant differences were found among implants revised for aseptic loosening versus any other reason for revision (54% vs 30%; p=.18). Discussion. Our results demonstrate high rates of bone ingrowth extent in contemporary designs, further supporting porous design rationales and a role for additive manufacturing to form enhanced porosity. We plan on exploring staining techniques to confirm our visual inspection. Contemporary designs have shown successful rates for improved longevity for cementless total knee systems. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_9 | Pages 3 - 3
1 Jun 2021
Dejtiar D Wesseling M Wirix-Speetjens R Perez M
Full Access

Introduction. Although total knee arthroplasty (TKA) is generally considered successful, 16–30% of patients are dissatisfied. There are multiple reasons for this, but some of the most frequent reasons for revision are instability and joint stiffness. A possible explanation for this is that the implant alignment is not optimized to ensure joint stability in the individual patient. In this work, we used an artificial neural network (ANN) to learn the relation between a given standard cruciate-retaining (CR) implant position and model-predicted post-operative knee kinematics. The final aim was to find a patient-specific implant alignment that will result in the estimated post-operative knee kinematics closest to the native knee. Methods. We developed subject-specific musculoskeletal models (MSM) based on magnetic resonance images (MRI) of four ex vivo left legs. The MSM allowed for the estimation of secondary knee kinematics (e.g. varus-valgus rotation) as a function of contact, ligament, and muscle forces in a native and post-TKA knee. We then used this model to train an ANN with 1800 simulations of knee flexion with random implant position variations in the ±3 mm and ±3° range from mechanical alignment. The trained ANN was used to find the implant alignment that resulted in the smallest mean-square-error (MSE) between native and post-TKA tibiofemoral kinematics, which we term the dynamic alignment. Results. Dynamic alignment average MSE kinematic differences to the native knees were 1.47 mm (± 0.89 mm) for translations and 2.89° (± 2.83°) for rotations. The implant variations required were in the range of ±3 mm and ±3° from the starting mechanical alignment. Discussion. In this study we showed that the developed tool has the potential to find an implant position that will restore native tibiofemoral kinematics in TKA. The proposed method might also be used with other alignment strategies, such as to optimize implant position towards native ligament strains. If native knee kinematics are restored, a more normal gait pattern can be achieved, which might result in improved patient satisfaction. The small changes required to achieve the dynamic alignment do not represent large modifications that might compromise implant survivorship. Conclusion. Patient-specific implant position predicted with MSM and ANN can restore native knee function in a post-TKA knee with a standard CR implant


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 51 - 51
1 May 2019
Barrack R
Full Access

In years past, the most common reason for revision following knee replacement was polyethylene wear. A more recent study indicates that polyethylene wear is relatively uncommon as a cause for total knee revision counting for only 10% or fewer of revisions. The most common reason for revision currently is aseptic loosening followed closely by instability and infection. The time to revision was surprisingly short. In a recent series only 30% of knees were greater than 5 years from surgery at the time of revision. The most common time interval was less than 2 years. This is likely because of the higher incidence of infection and instability that occurs most commonly at a relatively early time frame. Evaluation of a painful total knee should take into account these findings. All total knees that are painful within 5 years of surgery should be assumed to be infected until proven otherwise. Therefore, virtually all should be aspirated for cell count, differential, and culture. Alpha-defensin is also available in cases in which a patient may have been on antibiotics within a month or less, as well as cases in which diagnosis is a challenge for some reason. Instability can be diagnosed with physical exam focusing on mid-flexion instability which can be usually determined with the patient seated and the knee in mid-flexion, with the foot flat on the floor at which point sagittal plane laxity can be discerned. This is also frequently associated with symptoms of giving way and recurring effusions and difficulty descending stairs. A new phenomenon of tibial de-bonding has been described, which can be a challenge to diagnose. Radiographs can appear normal when loosening occurs between the implant and the cement mantle. This seems to be more common with the use of higher viscosity cement. Obviously this is technique dependent since good results have been reported with the use of high viscosity cement. Component malposition can cause stiffness and pain and relatively good results have been reported by component revision when malrotation has been confirmed with CT scan. When infection, instability and loosening are not present, extra-articular causes should be ruled out including lumbar spine, vascular compromise, complex regional pain syndromes and fibromyalgia, and peri-articular causes such as bursitis, tendonitis, tendon impingement among others. One of the most common causes of pain following total knee is unrealistic patient expectations. Performing total knee replacement in early stages of arthritis with only mild to moderate symptoms and radiographic changes has been associated with persistent pain and dissatisfaction. It may be prudent to obtain the immediate preoperative x-rays to determine if early intervention was undertaken and patients have otherwise normal appearing total knee x-rays and a negative work up. A recent study indicated that this was likely a cause or a major contributing factor to persistent pain following otherwise a well performed knee replacement. A national multicenter study of the appropriateness of indications for TKA also indicated that early intervention was a major cause of persistent pain, dissatisfaction, and failure to improve following total knee replacement


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 133 - 133
1 Feb 2017
MacDonald D Caton T Higgs G Malkani A Chen A Mont M Kurtz S
Full Access

Background. Sequentially annealed, highly crosslinked polyethylene (HXLPE) has been used clinically in total knee arthroplasty (TKA) for over a decade[1]. However, little is known about the reasons for HXLPE revision, its surface damage mechanisms, or its in vivo oxidative stability relative to conventional polyethylene. We asked whether retrieved sequentially annealed HLXPE tibial inserts exhibited: (1) similar reasons for revision; (2) enhanced resistance to surface damage; and (3) enhanced oxidative stability, when compared with tibial inserts fabricated from conventional gamma inert sterilized polyethylene (control). Methods. Four hundred and fifty-six revised tibial inserts in two cohorts (sequentially annealed and conventional UHMWPE control) were collected in a multicenter retrieval program between 2000 and 2016. We controlled for implantation time between the two cohorts by excluding tibial inserts with a greater implantation time than the longest term sequentially annealed retrieval (9.5 years). The mean implantation time (± standard deviation) for the sequentially annealed components was 1.9 ± 1.7 years, and for the control inserts, 3.4 ± 2.7 years (Figure 1). Reasons for HXLPE revision were assessed based on medical records, radiographs, and examinations of the retrieved components. Surface damage mechanisms were assessed using the Hood method[2]. Oxidation was measured at the bearing surface, the backside surface, the anterior and posterior faces, as well as the post (when available) using FTIR (ASTM F2102). Surface damage and oxidation analyses were available for 338 of the components. We used nonparametric statistical testing to analyze for differences in oxidation and surface damage when adjusting for polyethylene formulation as a function of implantation time. Results. The tibial inserts in both cohorts were revised most frequently for loosening, infection, and instability. Instability was observed more frequently in inserts without a stabilizing post. In both cohorts, the most commonly observed surface damage mechanisms were burnishing, pitting, and scratching. Delamination was rare and only observed in 2 sequentially annealed inserts and 7 inserts in the control cohort. We observed six cases of posterior condyle fracture, which was always associated with instability (Figure 2). 5/6 of the fracture cases did not have a stabilizing post. Oxidation indices of the sequentially annealed inserts were, on average, low (ASTM oxidation index < 1) and not significantly different than the control inserts on the bearing surface and anterior/posterior face (Figure 3). Discussion. The findings of this study document the reasons for revision, surface damage mechanisms, and oxidative behavior of sequentially annealed HXLPE for TKA. We observed evidence of low in vivo oxidation in both retrieved sequentially annealed HXLPE and control tibial inserts. We found no association between the levels of oxidation and clinical performance of the HXLPE tibial components. However, because of the short-term follow-up, analysis of longer-term retrievals may be appropriate


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 25 - 25
1 Aug 2020
Salimian A Howatt J Dervin G Kim P
Full Access

The Oxford mobile bearing knee prosthesis (Zimmer Biomet Inc, Warsaw, Ind) is considered a good treatment option for isolated medial compartment knee arthrosis. From February 2001 until August 2016, 1719 primary Oxford medial unicompartmental knee replacement procedures were completed at our center by a group of seven surgeons. We undertook this study to examine the long-term survivorship of the Oxford unicompartmental knee replacement looking at survivorship and reasons for failure. A retrospective consecutive case series review was completed, and all revisions and re-operations were identified. Conversion to total knee replacement (TKA) was considered a failure. Kaplan-Meier survival analysis was used to calculate the 15-year survivorship of the group overall. We specifically looked at age, gender, BMI and surgeon caseload in addition to the reasons for failure. A statistical analysis was performed and differences in survivorship were compared for the variables listed. A logistic cox regression was performed to explore predictors of revision. Overall 15-year survivorship was 89.9%. Female survivorship of 88.1% was statistically worse than the male group at 91.8% (p=0.018). Younger patients (75yrs of age (p= 0.036). There was a large range in surgical case load by individual surgeons (range 17–570 knees). There were no statistically significant differences in age, BMI, or gender when comparing the individual surgeon groups. There was a large range in 15-year survivorship between individual surgeons (range 78.3% – 95%). Overall the most common reason for revision was due to wear of the unreplaced portion of the knee (lateral and/or patella-femoral joint) followed by aseptic loosening, polyethylene dislocation, infection or persistent pain. The 15-year survivorship results of the Oxford medial unicompartmental knee replacement at our center compares favourably to other published series and large registry data series. We found a reduction in survivorship in female patients and younger patients (< 5 5yrs). There were also significant differences in survivorship based on the individual surgeon. A more selective patient approach yielded the best long-term survivorship and equivalent to that of total knee replacement. We therefore suggest using a more selective approach when choosing patients for a medial unicompartmental knee replacement with the Oxford mobile bearing prosthesis in order to enhance long-term survivorship


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 68 - 68
1 Apr 2019
Van Citters D Currier B
Full Access

Introduction. While advances in joint-replacement technology have made total ankle arthroplasty a viable treatment for end-stage arthritis, revision rates for ankle replacements are higher than in hip or knee replacements [1]. The questions asked in this study were (1) what retrieved ankle devices demonstrate about ankle arthroplasty failures, and (2) how do these failures compare to those seen in the hip and the knee?. Materials and Methods. An IRB-approved retrieval laboratory received retrieved polyethylene inserts and surgeon-supplied reason for revision from 70 total-ankles (7 designs, including five currently-marketed designs) from 2002 to the present. All retrievals were rated for clinical damage. Polyethylene inserts received six months or less after retrieval (n=45) were analyzed for oxidation using Fourier Transform Infrared (FTIR) spectroscopy, reported as maximum ketone oxidation index [2]. Insert sterilization method was verified using trans-vinylene index [3]. Oxidation measured in the 45 ankle inserts versus their time in vivo was compared to oxidation rates previously published for gamma-sterilized hip and knee polyethylene retrievals [6]. Statistical analysis was performed using IBM SPSS v.22. Results. The ankle devices were retrieved most commonly for loosening (n=22) followed by polyethylene fracture (n=9). These failure modes occurred after statistically different in vivo time (loosening: mean=4.4±3.6 years; polyethylene insert fracture: mean=9.5±4.1 years; p=0.002). Presence of clinical fatigue (cracking and/or delamination) was identified in 24 of the 70 retrieved inserts, and its presence correlated with in vivo time (Spearman's rho =0.449, p<0.001). Thirteen of these fatigued inserts were analyzed by FTIR. TVI analysis confirmed the sterilization method of the fatigued inserts: 12 gamma, 1 non-gamma sterilized. All 13 fatigued inserts had maximum ketone oxidation index (KOI) of 1.2 or higher. Presence of fatigue correlated with measured oxidation (Spearman's rho =0.685, p<0.001). Six of the 9 inserts that fractured in vivo were analyzed by FTIR. All were gamma-sterilized, and all had oxidation of 1.2 or higher. Oxidation rate determined for most of the 45 ankle inserts was at or above oxidation rates previously published for gamma-sterilized hip and knee polyethylene retrievals [6]. Discussion. This retrieval study concurs with the ankle arthroplasty literature that loosening is the most common reason for ankle revision [4]. Ankle inserts retrieved as a result of implant loosening had lower oxidation and no fatigue damage resulting from their shorter in vivo time. Fatigued and/or fractured inserts were in vivo for longer times, allowing more oxidation to occur. The effect of oxidation on polyethylene tensile strength and ductility has been reported for tibial inserts [5]. Oxidation above the critical value [5] has a dramatic effect on the ability of the polyethylene to resist fatigue damage and fracture, since the toughness of the polyethylene drops to near zero. All fatigued and fractured ankle inserts had oxidation that exceeded this critical oxidation. Most ankle inserts, whether gamma or non-gamma sterilized, oxidized at or above the oxidation rates previously published for gamma-sterilized hip and knee polyethylene retrievals [6]