The attitudes of orthopaedic surgeons regarding radiology reporting is not well-described in the literature. We surveyed Orthopaedic Surgeons in Australia and New Zealand to assess if they routinely review formal radiology reports. An anonymized, 14 question online survey was distributed to consultant surgeons of the Australian and New Zealand Orthopaedic Associations (AOA, NZOA). Two hundred respondents completed the survey (Total number of Fellows: 283 NZOA, 1185 AOA). 18.5% of respondents always reviewed the formal Radiology report, 44.5% most of the time, 35% sometimes and 2% never. By imaging modality, MRI reports were the most frequently reviewed (92%), followed by ultrasound (74%) and nuclear medicine (63%). Only 10% of surgeons consulted formal reports for plain radiography. 55% of surgeons were still likely to disagree with the MRI report, followed by 46% for plain radiography. In cases of disagreement, only 21% of surgeons would always contact the reporting
Introduction. Derotation osteotomies are commonly performed in paediatric orthopaedic and limb reconstruction practice. The purpose of this study was to determine whether the use of a digital inclinometer significantly improves the accuracy in attaining the desired correction. Materials & Methods. We designed an electronic survey regarding derotation femoral osteotomy (DFO) including methods of intra-operative angular correction assessment and acceptable margins of error for correction. This was distributed to 28 paediatric orthopaedic surgeons in our region. A DFO model was created, using an anatomic sawbone with foam covering. 8 orthopaedic surgeons each performed two 30-degree DFOs, one using K-wires and visual estimation (VE), and the other using a Digital Inclinometer (DI). Two
Abstract. Purpose. Intracanal rib head penetration is a well-known entity in dystrophic scoliotic curves in neurofibromatosis type 1. There is potential for spinal cord injury if this is not recognised and managed appropriately. No current CT-based classification system is currently in use to quantify rib head penetration. This study aims to propose and evaluate a novel CT-based classification for rib head penetration primarily for neurofibromatosis but which can also be utilised in other conditions of rib head penetration. Materials and methods. The grading was developed as four grades: normal rib head (RH) position—Grade 0, subluxed ext-racanal RH position—Grade 1, RH at pedicle—Grade 2, intracanal RH—Grade 3. Grade 3 was further classified depending on the head position in the canal divided into thirds. Rib head penetration into proximal third (from ipsilateral side)—Grade 3A, into the middle third—Grade 3B and into the distal third—Grade 3C. Seventy-five axial CT images of Neurofibromatosis Type 1 patients in the paediatric age group were reviewed by a
The diagnosis of infection following shoulder arthroplasty is notoriously difficult. The prevalence of prosthetic shoulder infection after arthroplasty ranges from 3.9 – 15.4% and the most common infective organism is Cutibacterium acnes. Current preoperative diagnostic tests fail to provide a reliable means of diagnosis including WBC, ESR, CRP and joint aspiration. Fluoroscopic-guided percutaneous synovial biopsy (PSB) has previously been reported in the context of a pilot study and demonstrated promising results. The purpose of this study was to determine the diagnostic accuracy of percutaneous synovial biopsy compared with open culture results (gold standard). This was a multicenter prospective cohort study involving four sites and 98 patients who underwent revision shoulder arthroplasty. The cohort was 60% female with a mean age was 65 years (range 36-83 years). Enrollment occurred between June 2014 and November 2021. Pre-operative fluoroscopy-guided synovial biopsies were carried out by musculoskeletal
Bone age is a radiographical assessment used in pediatric medicine due to its relative objectivity in determining biological maturity compared to chronological age and size.1 Currently, Greulich and Pyle (GP) is one of the most common methods used to determine bone age from hand radiographs.2–4 In recent years, new methods were developed to increase the efficiency in bone age analysis like the shorthand bone age (SBA) and the automated artificial intelligence algorithms. The purpose of this study is to evaluate the accuracy and reliability of these two methods and examine if the reduction in analysis time compromises their accuracy. Two hundred thirteen males and 213 females were selected. Each participant had their bone age determined by two separate raters using the GP (M1) and SBA methods (M2). Three weeks later, the two raters repeated the analysis of the radiographs. The raters timed themselves using an online stopwatch while analyzing the radiograph on a computer screen. De-identified radiographs were securely uploaded to an automated algorithm developed by a group of
Abstract. Purpose. No clinical CT based classification system is currently in use for Lumbar Foraminal Stenosis. MRI scanners are not easily available, are expensive and may be contraindicated in an increasing number of patients. This study aims to propose and evaluate the reproducibility of a novel CT based classification for lumbar foraminal stenosis. Materials and Methods. The grading was developed as 4 grades. Normal foramen – Grade 0, Anteroposterior(AP)/Superoinferior (SI)(single plane) fat compression – Grade 1, Both AP/SI compression (two planes) – Grade 2 (both AP and SI) without distortion of nerve root, Grade 2 with distortion of nerve root – Grade 3. 800 lumbar foramen of a cohort of 100 random patients over the age of 60 who had undergone both CT and MRI scans were reviewed by two
Ceramic-on-ceramic bearings provide a solution to the osteolysis seen with traditional metal-on-polyethylene bearings. Sporadic reports of ceramic breakage and squeaking concern some surgeons and this bearing combination can show in vivo signs of edge loading wear which was not predicted from in vitro studies. Taper damage or debris in the taper between the ceramic and metal may lead to breakage of either a ceramic head or insert. Fastidious surgical technique may help to minimise the risk of ceramic breakage. Squeaking is usually a benign complication, most frequently occurring when the hip is fully flexed. Rarely, it can occur with each step of walking when it can be sufficiently troublesome to require revision surgery. The etiology of squeaking is multifactorial in origin. Taller, heavier and younger patients with higher activity levels are more prone to hips that squeak. Cup version and inclination are also relevant factors. Osteolysis following metal-on-UHMW polyethylene Total Hip Arthroplasty (THA) is well reported. Earlier generation ceramic-on-ceramic bearings did produce some osteolysis, but in flawed implants. As third and now fourth generation ceramic THAs come into mid- and long-term service, the orthopaedic community has begun to see reports of high survival rates and very low incidence of osteolysis in these bearings. The technique used by
Background. It has been suggested that routine follow-up of primary THR patients could be performed by GPs in primary care, rather than by orthopaedic specialists. Essential radiographic follow-up would likely be based on radiographic reports, rather than on inspection of the radiographs themselves. Aim. To look at the quality of the radiographic reports to determine their usefulness as a method of radiographic follow-up of THRs. Methods. The immediate pre-revision radiographs of a consecutive series of 50 patients, who had undergone revision surgery in 2 hospitals, were examined by a senior orthopaedic registrar, supervised by a Consultant with a revision THR practice, and compared to the findings of the corresponding
Ceramic-on-ceramic bearings provide a solution to the osteolysis seen with traditional metal-on-polyethylene bearings. Sporadic reports of ceramic breakage and squeaking concern some surgeons and this bearing combination can show in vivo signs of edge loading wear which was not predicted from in vitro studies. Taper damage or debris in the taper between the ceramic and metal may lead to breakage of either a ceramic head or insert. Fastidious surgical technique may help to minimise the risk of ceramic breakage. Squeaking is usually a benign complication, most frequently occurring when the hip is fully flexed. Rarely, it can occur with each step of walking when it can be sufficiently troublesome to require revision surgery. The etiology of squeaking is multifactorial origin. Taller, heavier and younger patients with higher activity levels are more prone to hips that squeak. Cup version and inclination are also relevant factors. Fifty-five ceramic bearings revised at our center were collected over 12 years. Median time to revision was 2.7 years. Forty-six (84%) cases had edge loading wear. The median femoral head wear volume overall was 0.2mm. 3. /yr, for anterosuperior edge loading was 2.0mm. 3. /yr, and the median volumetric wear rate for posterior edge loading was 0.15mm. 3. /yr (p=0.005). Osteolysis following metal-on-polyethylene total hip arthroplasty (THA) is well reported. Earlier generation ceramic-on-ceramic bearings did produce some osteolysis, but in flawed implants. As 3rd and now 4th generation ceramic THAs come into mid- and long-term service, the orthopaedic community has begun to see reports of high survival rates and very low incidence of osteolysis in these bearings. The technique used by
Myxofibrosarcoma (MFS) is the second most common subtype of soft tissue sarcoma (STS) and is associated with a high rate of local recurrence after resection. These tumours frequently present with peri-lesional edema, termed “tumour tails” on staging MRI scans [1]. Tumour tails(TT) may contain satellite neoplastic cells or can represent benign reactive edema. There are no clear radiological features to distinguish malignant from reactive peri-lesional edema which limits accurate surgical planning, resulting in either high rates of inadvertently positive resection margins and local recurrences or overly-aggressive resections which negatively impact function and increase morbidity [2]. The objective of this pilot study was to prospectively study a cohort of MFS patients with TTs in an attempt to identify radiological features that predict which type of edema is malignant and requires resection together with the main tumour mass. Patients diagnosed with MFS on biopsy at an orthopaedic oncology referral centre between January 1-December 31 2018 who also had TTs on staging MRI scans were prospectively recruited for the study. Tumours were treated with wide surgical excision, including the TTs, and (neo)adjuvant radiotherapy as per institutional protocol. Staging MRI scans were reviewed in a blinded fashion by two musculoskeletal
Ultrasound (US) is the standard imaging modality used to screen for developmental dysplasia of the hip in infants. Currently,
Introduction. In the evaluation of patients with pre-arthritic hip disorders, making the correct diagnosis and identifying the underlying bone pathology is of upmost importance to achieve optimal patient outcomes. 3-dimensional imaging adds information for proper preoperative planning. CT scans have become the gold standard for this, but with the associated risk of radiation exposure to this generally younger patient cohort. Purpose. To determine if 3D-MR reconstructions of the hip can be used to accurately demonstrate femoral and acetabular morphology in the setting of femoroacetabular impingement (FAI) and development dysplasia of the hip (DDH) that is comparable to CT imaging. Materials and Methods. We performed a retrospective review of 14 consecutive patients with a diagnosis of FAI or DDH that underwent both CT and MRI scans of the same hip with 3D reconstructions. 2 fellowship trained musculoskeletal
Surgical reattachment of torn rotator cuff tendons can lead to satisfactory clinical outcome but failures remain common. Ortho-R product is a freeze-dried formulation of chitosan (CS) that is solubilized in platelet-rich plasma (PRP) to form injectable implants. The purpose of the current pilot study was to determine Ortho-R implant acute residency, test safety of different implant doses, and assess efficacy over standard of care in a sheep model. The infraspinatus tendon (ISP) was detached and immediately repaired in 22 skeletally mature ewes. Repair was done with four suture anchors in a suture bridge configuration (n = 6 controls). Freeze-dried formulations containing 1% w/v chitosan (number average molar mass 35 kDa and degree of deacetylation 83%) with 1% w/v trehalose (as lyoprotectant) and 42.2 mM calcium chloride (as clot activator) were solubilized with autologous leukocyte-rich PRP and injected at the tendon-bone interface and on top of the repaired site (n = 6 with a 1 mL dose and n = 6 with a 2 mL dose). Acute implant residency was assessed histologically at 1 day (n = 2 with a 1 mL dose and n = 2 with a 2 mL dose). Outcome measures included MRI assessment at baseline, 6 weeks and 12 weeks, histopathology at 12 weeks and clinical pathology. MRI images and histological slides were scored by 2 blinded readers (veterinarian and human
Introduction. Total knee arthroplasty (TKA) is one of the most successful surgeries to relieve pain and dysfunction caused by severe arthritis. However, it is a still big problem that there is a possibility of death in pulmonary embolism (PE) after TKA. We previously reported that there was more incidence of asymptomatic PE than estimated in general by detail examinations. But it was difficult to whom we decided to perform additional examinations except the patients with some doubtful symptoms. Therefore, we investigated detail of PE patients after primary TKA to find out anything key point in PE. Methods. Consecutive ninety-nine patients who underwent primary TKA from January 2015 to March 2018 were applied. There were 23 male and 76 females included, and the mean age was 73.7 years old. There were 96 cases of osteoarthritis, 2 cases of osteonecrosis and one of rheumatoid arthritis. A single knee surgery team performed all operations with cemented type prostheses and air tourniquet during operation. There were 35 cases of one-staged bilateral TKA and 64 of unilateral TKA. Detail examinations with contrast enhanced CT (CE-CT) and venous ultrasonography (US) were performed at the 3rd day after surgery. Next, we applied ultra sound cardiogram (UCG) to the patients diagnosed as PE by CE-CT, we checked right ventricular overload (RVO) to treat PE. These images were read by a single senior
Introduction. Osteloysis following metal-on-UHMW polyethylene Total Hip Arthroplasty (THA) is well reported, as is lack of osteolysis following Ceramic-on-Ceramic (CoC)THA. Early ceramic failures did report some osteolysis, but in flawed implants. As 3rd and now 4th generation ceramic THAs come into mid- and long-term use, the orthopaedic community has begun to see reports of high survival rates and very low incidence of osteolysis in these bearings. Osteolysis reported after 3rd generation CoC THA often included metallosis due to neck rim impingement. In our department we have revised only 2 hips in over 6000 CoC THAs for osteolysis. Both had evidence of metallosis as well as ceramic wear. The technique used by Radiologists for identifying the nature of lesions on CT is the Hounsfield score which will identify the density of the tissue within the lucent area. It is common for
INTRODUCTION. Mechanical loosening of total hip replacement (THR) is primarily diagnosed using radiographs, which are diagnostically challenging and require review by experienced
The aim of this prospective study was to determine the prevalence of bone marrow oedema (BME) in asymptomatic knees of athletes and to investigate the factors associated with appearance of BME in this group. A total of 25 asymptomatic athletes who competed at an international, national or county level during their most recent sport season were recruited in this study and had MRI scan of both knees (n=50). MRI scans were reported independently by two experienced musculoskeletal
Manual postoperative CT calculation of anteversion and inclination of the acetabular cup can be inaccurate and depends on the observer's experience. The aim of this study is to describe and present a validation of a new CT-image-based dedicate software (EGIT) for calculation of the acetabular component placement. The software principle is based on a three-dimensional reconstruction of a patient's bones from anatomical data collected postoperatively on the patient's CT scan. 15 Patient to be operated for THR were enrolled in this study. All patients were evaluated with post operative CT-scan. Measurement of Cup positioning were performed with two different methods: a manual method, performed by an expert
Introduction. Literature in respect to the MRI appearances of surgically confirmed spring ligament pathology is sparse. The authors conducted a retrospective review of MRI examinations comprising 13 patients with surgically proven spring ligament abnormality. Methods. Records for operations performed for planovalgus foot deformity with operation notes confirming presence of spring ligament abnormality were obtained for patients treated 2010–11. Of 32 procedures 13 patients (3 male, 10 female) mean age 48.5 (range, 21–86 years) underwent preoperative MRI scanning using a standard musculoskeletal protocol on a T1.5 unit. Scans were retrospectively reviewed by one of the senior authors and consultant musculoskeletal
The standard of wide tumour-like resection for chronic osteomyelitis (COM) has been challenged recently by adequate debridement. This paper reviews the evolution of surgical debridement for long bone COM, and presents the outcome of adequate debridement in a tertiary bone infection unit. We analyzed the retrospective record review from 2014 to 2020 of patients with long bone COM. All were managed by multidisciplinary infection team (MDT) protocol. Adequate debridement was employed for all cases, and no case of wide resection was included.Aims
Methods