Abstract

Introduction

Derotation osteotomies are commonly performed in paediatric orthopaedic and limb reconstruction practice. The purpose of this study was to determine whether the use of a digital inclinometer significantly improves the accuracy in attaining the desired correction.

Materials & Methods

We designed an electronic survey regarding derotation femoral osteotomy (DFO) including methods of intra-operative angular correction assessment and acceptable margins of error for correction. This was distributed to 28 paediatric orthopaedic surgeons in our region. A DFO model was created, using an anatomic sawbone with foam covering. 8 orthopaedic surgeons each performed two 30-degree DFOs, one using K-wires and visual estimation (VE), and the other using a Digital Inclinometer (DI). Two radiologists reported pre and post procedure rotational profile CT scans to assess the achieved rotational correction.

Results

There was a 68% response rate to the survey. The most popular methods of estimating intra-operative correction were reported to be K-wires and rotation marks on bone. The majority of respondents reported that a 6–10 degree margin of error was acceptable for a 30-degree derotation. This was therefore set as the upper limit for acceptable error margin in the simulation study. The mean error in rotation in the VE group of simulated DFO was 19.7 degrees, with error>5 degrees and error>10 degrees in 7 (88%) and 6 (75%) cases respectively. Mean error in DI group was 3.1 degrees, with error>5 degrees in 1 case (13%).

Conclusions

Our results show that the compared to conventional techniques, the use of an inclinometer significantly improves the accuracy of femoral de-rotation and significantly reduces the incidence of unacceptable errors in correction. We would suggest that digital inclinometers be used to assess intra-operative correction during derotation osteotomies.