Advertisement for orthosearch.org.uk
Results 1 - 20 of 196
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 83 - 83
1 Dec 2022
Bornes T Kubik J Klinger C Altintas B Dziadosz D Ricci W
Full Access

Tibial plateau fracture reduction involves restoration of alignment and articular congruity. Restorations of sagittal alignment (tibial slope) of medial and lateral condyles of the tibial plateau are independent of each other in the fracture setting. Limited independent assessment of medial and lateral tibial plateau sagittal alignment has been performed to date. Our objective was to characterize medial and lateral tibial slopes using fluoroscopy and to correlate X-ray and CT findings.

Phase One: Eight cadaveric knees were mounted in extension. C-arm fluoroscopy was used to acquire an AP image and the C-arm was adjusted in the sagittal plane from 15° of cephalad tilt to 15 ° of caudad tilt with images captured at 0.5° increments. The “perfect AP” angle, defined as the angle that most accurately profiled the articular surface, was determined for medial and lateral condyles of each tibia by five surgeons. Given that it was agreed across surgeons that more than one angle provided an adequate profile of each compartment, a range of AP angles corresponding to adequate images was recorded. Phase Two: Perfect AP angles from Phase One were projected onto sagittal CT images in Horos software in the mid-medial compartment and mid-lateral compartment to determine the precise tangent subchondral anatomic structures seen on CT to serve as dominant bony landmarks in a protocol generated for calculating medial and lateral tibial slopes on CT. Phase Three: 46 additional cadaveric knees were imaged with CT. Tibial slopes were determined in all 54 specimens.

Phase One: Based on the perfect AP angle on X-ray, the mean medial slope was 4.2°+/-2.6° posterior and mean lateral slope was 5.0°+/-3.8° posterior in eight knees. A range of AP angles was noted to adequately profile each compartment in all specimens and was noted to be wider in the lateral (3.9°+/-3.8°) than medial compartment (1.8°+/-0.7° p=0.002). Phase Two: In plateaus with a concave shape, the perfect AP angle on X-ray corresponded with a line between the superiormost edges of the anterior and posterior lips of the plateau on CT. In plateaus with a flat or convex shape, the perfect AP angle aligned with a tangent to the subchondral surface extending from center to posterior plateau on CT. Phase Three: Based on the CT protocol created in Phase Two, mean medial slope (5.2°+/-2.3° posterior) was significantly less than lateral slope (7.5°+/-3.0° posterior) in 54 knees (p<0.001). In individual specimens, the difference between medial and lateral slopes was variable, ranging from 6.8° more laterally to 3.1° more medially. In a paired comparison of right and left knees from the same cadaver, no differences were noted between sides (medial p=0.43; lateral p=0.62).

On average there is slightly more tibial slope in the lateral plateau than medial plateau (2° greater). However, individual patients may have substantially more lateral slope (up to 6.8°) or even more medial slope (up to 3.1°). Since tibial slope was similar between contralateral limbs, evaluating slope on the uninjured side provides a template for sagittal plane reduction of tibial plateau fractures.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 77 - 77
7 Nov 2023
Dey R Nortje M du Toit F Grobler G Dower B
Full Access

Hip abductor tears(AT) have long been under-recognized, under-reported and under-treated. There is a paucity of data on the prevalence, morphology and associated factors. Patients with “rotator cuff tears of the hip” that are recognized and repaired during total hip arthroplasty(THA) report comparable outcomes to patients with intact abductor tendons at THA.

The study was a retrospective review of 997 primary THA done by a single surgeon from 2012–2022. Incidental findings of AT identified during the anterolateral approach to the hip were documented with patient name, gender, age and diagnosis. The extent and size of the tears of the Gluteus medius and Minimus were recorded. Xrays and MRI's were collected for the 140 patients who had AT and matched 1:1 with respect to age and gender against 140 patients that had documented good muscle quality and integrity. Radiographic measurements (Neck shaft angle, inter-teardrop distance, Pelvis width, trochanteric width and irregularities, bodyweight moment arm and abductor moment arm) were compared between the 2 groups in an effort to determine if any radiographic feature would predict AT.

The prevalence of AT were 14%. Females had statistically more tears than males(18vs10%), while patients over the age of 70y had statistically more tears overall(19,7vs10,4%), but also more Gluteus Medius tears specifically(13,9vs5,3%). Radiographic measurements did not statistically differ between the tear and control group, except for the presence of trochanteric irregularities. MRI's showed that 50% of AT were missed and subsequently identified during surgery.

Abductor tears are still underrecognized and undertreated during THA which can results in inferior outcomes. The surgeon should have an high index of suspicion in elderly females with trochanteric irregularities and although an MRI for every patient won't be feasible, one should always be prepared and equipped to repair the abductor tendons during THA.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 92 - 92
23 Feb 2023
Lee S Lin J Lynch J Smith P
Full Access

Dysmorphic pelves are a known risk factor for malpositioned iliosacral screws. Improved understanding of pelvic morphology will minimise the risk of screw misplacement, neurovascular injuries and failed fixation. Existing classifications for sacral anatomy are complex and impractical for clinical use. We propose a CT-based classification using variations in pelvic anatomy to predict the availability of transosseous corridors across the sacrum. The classification aims to refine surgical planning which may reduce the risk of surgical complications.

The authors postulated 4 types of pelves. The “superior most point of the sacroiliac joint” (sSIJ) typically corresponds with the mid-lower half of the L5 vertebral body. Hence, “the anterior cortex of L5” (L5a) was divided to reference 3 distinct pelvic groups. A 4th group is required to represent pelves with a lumbosacral transitional vertebra. The proposed classification:

A – sSIJ is above the midpoint of L5a

B – sSIJ is between the midpoint and the lowest point of L5a

C – sSIJ is below the lowest point of L5a

D – pelves with a lumbosacral transitional vertebra

Specific measures such as the width of the S1 and S2 axial and coronal corridors and the S1 lateral mass angles were used to differentiate between pelvic types.

Three-hundred pelvic CT scans were classified into their respective types. Analysis of the specific measures mentioned above illustrated the significant difference between each pelvic type. Changes in the size of S1 and S2 axial corridors formed a pattern that was unique for each pelvic type. The intra- and inter-observer ratings were 0.97 and 0.95 respectively.

Distinct relationships between the sizes of S1 and S2 axial corridors informed our recommendations on trans-sacral or iliosacral fixation, number and orientation of screws for each pelvic type. This classification utilises variations in the posterior pelvic ring to offer a planning guide for the insertion of iliosacral screws.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 25 - 25
7 Nov 2023
du Plessis R Roche S du Plessis J Dey R de Kock W de Wet J
Full Access

The Latarjet procedure is a well described method to stabilize anterior shoulder instability. There are concerns of high complication rates, one of these being a painful shoulder without instability due to screw irritation. The arthroscopic changes in the shoulder at time of screw removal compared to those pre-Latarjet have not been described in the literature.

We conducted a retrospective review of arthroscopic videos between 2015 and 2022 of 17 patients at the time of their Latarjet screw removal and where available (n=13) compared them to arthroscopic findings at time of index Latarjet. Instability was an exclusion criterion. X-rays prior to screw removal were assessed independently by two observers blinded to patient details for lysis of the graft. Arthroscopic assessment of the anatomy and pathological changes were made by two shoulder surgeons via mutual consensus. An intraclass correlation coefficient (ICC) was analyzed as a measure for the inter-observer reliability for the radiographs.

Our cohort had an average age of 21.5±7.7 years and an average period of 16.2±13.1 months between pre- and post-arthroscopy. At screw removal all patients had an inflamed subscapularis muscle with 88% associated musculotendinous tears and 59% had a pathological posterior labrum. Worsening in the condition of subscapularis muscle (93%), humeral (31%) and glenoid (31%) cartilage was found when compared to pre-Latarjet arthroscopes. Three failures of capsular repair were seen, two of these when only one anchor was used. X-ray review demonstrated 79% of patients had graft lysis. Excellent inter-rater reliability was observed with an ICC value of 0.82.

Our results show a high rate of pathological change in the subscapularis muscle, glenoid labrum and articular cartilage in the stable but painful Latarjet. 79% of patients had graft lysis with prominent screws on X-ray.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 114 - 114
23 Feb 2023
Chai Y Boudali A Farey J Walter W
Full Access

Human error is usually evaluated using statistical descriptions during radiographic annotation. The technological advances popularized the “non-human” landmarking techniques, such as deep learning, in which the error is presented in a confidence format that is not comparable to that of the human method. The region-based landmark definition makes an arbitrary “ground truth” point impossible. The differences in patients’ anatomies, radiograph qualities, and scales make the horizontal comparison difficult. There is a demand to quantify the manual landmarking error in a probability format.

Taking the measurement of pelvic tilt (PT) as an example, this study recruited 115 sagittal pelvic radiographs for the measurement of two PTs. We proposed a method to unify the scale of images that allows horizontal comparisons of landmarks and calculated the maximum possible error using a density vector. Traditional descriptive statistics were also applied.

All measurements showed excellent reliabilities (intraclass correlation coefficients > 0.9). Eighty-four measurements (6.09%) were qualified as wrong landmarks that failed to label the correct locations. Directional bias (systematic error) was identified due to cognitive differences between observers. By removing wrong labels and rotated pelves, the analysis quantified the error density as a “good doctor” performance and found 6.77°-11.76° maximum PT disagreement with 95% data points.

The landmarks with excellent reliability still have a chance (at least 6.09% in our case) of making wrong landmark decisions. Identifying skeletal contours is at least 24.64% more accurate than estimating landmark locations. The landmark at a clear skeletal contour is more likely to generate systematic errors. Due to landmark ambiguity, a very careful surgeon measuring PT could make a maximum 11.76° random difference in 95% of cases, serving as a “good doctor benchmark” to qualify good landmarking techniques.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 55 - 55
10 Feb 2023
Goddard-Hodge D Baker J
Full Access

Reduced cervical spine canal AP diameter is linked to the development of spinal cord injury and myelopathy. This is of particular interest to clinicians in New Zealand, given a unique socio-ethnic make-up and prevalent participation in collision sport. Our study builds upon previous unpublished evidence, by analysing normal cervical spine CT scans to explore morphological differences in the sub-axial cervical spine canal, between New Zealand European, Māori and Paciāca individuals.

670 sub-axial cervical vertebrae (C3-C7) were analysed radiographically using high resolution CT trauma scans, showing no acute pathology with respect to the cervical spine. All measurements were made uPlising mulP-planar reconstruction software to obtain slices parallel to the superior endplate at each vertebral level. Maximal canal diameter was measured in the AP and transverse planes. Statistical analysis was performed using analysis of variance (ANOVA).

We included 250 Maori, 250 NZ European and 170 Paciāca vertebrae (455 male, 215 female). Statistically and clinically signiācant differences were found in sagittal canal diameter between all ethnicities, at all spinal levels. NZ European vertebrae demonstrated the largest AP diameter and Paciāca the smallest, at all levels. Transverse canal diameter showed no signiācant difference between ethnicities, however the raatio of AP:transverse diameter was signiācantly different at all spinal levels except C3. Subjective morphological differences in the shape of the vertebral canal were noted, with Māori and Paciāca patients tending towards a flatter, curved canal shape.

A previous study of 166 patients (Coldham, G. et al. 2006) found cervical canal AP diameter to be narrower in Māori and Paciāca patients than in NZ Europeans. Our study, evaluating the normal population, conārms these differences are likely reflecPve of genuine variation between these ethniciPes. Future research is required to critically evaluate the morphologic differences noted during this study.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 30 - 30
10 May 2024
Davies O Mowbray J Maxwell R Hooper G
Full Access

Introduction

The Oxford Unicompartmental Knee Replacement (OUKA) is the most popular unicompartmental knee replacement (UKR) in the New Zealand Joint Registry with the majority utilising cementless fixation. We report the 10-year radiological outcomes.

Methods

This is a prospective observational study. All patients undergoing a cementless OUKA between May 2005 and April 2011 were enrolled. There were no exclusions due to age, gender, body mass index or reduced bone density.

All knees underwent fluoroscopic screening achieving true anteroposterior (AP) and lateral images for radiographic assessment. AP assessment for the presence of radiolucent lines and coronal alignment of the tibial and femoral components used Inteliviewer radiographic software. The lateral view was assessed for lucencies as well as sagittal alignment.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 40 - 40
23 Feb 2023
Critchley O Guest C Warby S Hoy G Page R
Full Access

Glenoid bone grafting in reverse total shoulder arthroplasty (RTSA) has emerged as an effective method of restoring bone stock in the presence of complex glenoid bone loss, yet there is limited published evidence on efficacy. The aim of this study was to conduct an analysis of clinical and radiographic outcomes associated with glenoid bone grafting in primary RTSA.

Patients who underwent a primary RTSA with glenoid bone grafting were retrospectively identified from the databases of two senior shoulder surgeons. Inclusion criteria included minimum of 12 months clinical and/or radiographical follow up. Patients underwent preoperative clinical and radiographic assessment. Graft characteristics (source, type, preparation), range of movement (ROM), patient-reported outcome measures (Oxford Shoulder Scores [OSS]), and complications were recorded. Radiographic imaging was used to analyse implant stability, graft incorporation, and notching by two independent reviewers.

Between 2013 and 2021, a total of 53 primary RTSA procedures (48 patients) with glenoid bone grafting were identified. Humeral head autograft was used in 51 (96%) of cases. Femoral head allograft was utilised in two cases. Depending on the morphology of glenoid bone loss, a combination of structural (corticocancellous) and non-structural (cancellous) grafts were used to restore glenoid bone stock and the joint line. All grafts were incorporated at review. The mean post-operative OSS was significantly higher than the pre-operative OSS (40 vs. 22, p < 0.001). ROM was significantly improved post-operatively. One patient is being investigated for residual activity-related shoulder pain. This patient also experienced scapular notching resulting in the fracturing of the inferior screw. One patient experienced recurrent dislocations but was not revised.

Overall, at short term follow up, glenoid bone grafting was effective in addressing glenoid bone loss with excellent functional and clinical outcomes when used for complex bone loss in primary RTSA. The graft incorporation rate was high, with an associated low complication rate.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 9 - 9
7 Nov 2023
Blankson B Dunn R Noconjo L
Full Access

Adolescent idiopathic scoliosis (AIS) is a complex three-dimensional deformity of the spine characterized by a Cobb angle of at least 10 degrees. The goal of surgery is to not only prevent progression but restore sagittal and coronal balance, protecting cardiopulmonary function and improving cosmesis.

We reviewed the impact of deformity correction surgery in terms of radiology and patient reported outcome(PROMs).

The senior authors prospectively maintained database from 2003 –2022 was retrospectively analysed in terms of pre- and post-operative patient reported outcome measures (SRS 22) as well as radiological parameters.

44 patients with AIS were identified with pre and post op PROMS. The average age at surgery was 15yrs with 84% female. 38% had a Lenke 1 curve and 3 patients had Lenke 6 curves. 73% had posterior surgery.

There was a total improvement in SRS 22 scores by 7.8%. Patients reported significant satisfaction with treatment 4.8/5 and improvement in self-image with a change of 0.4 (p<0.001). However, no difference in function, pain and mental health were recorded.

Overall, proximal thoracic (PT) curves improved from 24 degrees to 11 degrees (p<0.001), Main thoracic (MT) curve 55 degrees to 19 degrees and Thoracolumbar/Lumbar curves (TL/L) 45 degreesto 11 degrees. Pre-operative flexibility and post-operative correction were 0.40 and 0.41 respectively for PT curve. MT was 0.32 and 0.67. That for TL/L was 0.57 and 0.71 respectively.

Surgery yields significant main curve correction correlating with high patient reported satisfaction rate. Although total SRS 22 score yielded 7.8% improvement, sub-analysis of self-image showed the most significant improvement.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 65 - 65
1 Feb 2020
Garcia-Rey E Garcia-Cimbrelo E
Full Access

Introduction. Pelvic tilt can vary over time due to aging and the possible appearance of sagittal spine disorders. Cup position in total hip arthroplasty (THA) can be influenced due to these changes. We assessed the evolution of pelvic tilt and cup position after THA and the possible appearance of complications for a minimum follow-up of ten years. Materials and methods. 343 patients received a cementless THA between 2006 and 2009. All were diagnosed with primary osteoarthritis and their mean age was 63.3 years (range, 56 to 80). 168 were women and 175 men. 250 had no significant lumbar pathology, 76 had significant lumbar pathology and 16 had lumbar fusion. Radiological analysis included sacro-femoral-pubic (SFP), acetabular abduction (AA) and anteversion cup (AV) angles. Measurements were done pre-operatively and at 6 weeks, and at five and ten years post-operatively. Three measurements were recorded and the mean obtained at all intervals. All radiographs were evaluated by the same author, who was not involved in the surgery. Results. There were nine dislocations: six were solved with closed reduction, and three required cup revision. All the mean angles changed over time; the SFP angle from 59.2º to 60º (p=0.249), the AA angle from 44.5º to 46.8º (p=0.218), and the AV angle from 14.7º to 16.2º (p=0.002). The SFP angle was lower in older patients at all intervals (p<0.001). The SFP angle changed from 63.8 to 60.4º in women and from 59.4º to 59.3º in men, from 58.6º to 59.6º (p=0.012). The SFP angle changed from 62.7º to 60.9º in patients without lumbar pathology, from 58.6º to 57.4º in patients with lumbar pathology, and from 57.0º to 56.4º in patients with a lumbar fusion (p=0.919). The SFP cup angle was higher in patients without lumbar pathology than in the other groups (p<0.001), however, it changed more than in patients with lumbar pathology or fusion at ten years after THA (p=0.04). Conclusions. Posterior pelvic tilt changed with aging, influencing the cup position in patients after a THA. Changes due to lumbar pathology could influence the appearance of complications at mid and long-term


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 127 - 127
1 May 2016
Laky B Heuberer P Brandl G Kriegleder B Anderl W Pauzenberger L
Full Access

In the past century several shoulder reconstruction systems with different types of prostheses and fixation methods have been developed to improve shoulder arthroplasty, especially to cover a wide range of pathologies and revision situations. The aim of this prospective trial was to report clinical and radiological mid-term results of a stemless humeral head replacement with metaphyseal hollow screw fixation. A consecutive series of 147 shoulders in 138 patients (84 female, 54 male; mean age of 67 years, range 40–84) undergoing stemless humeral head arthroplasty were considered for this single-centre trial. We prospectively followed 120 shoulders (40 hemi- and 80 total-arthroplasties) for an average of five years or until a reoperation. Patient's clinical and functional outcome was evaluated according to the Constant score and active range of motions (ROM) was measured. Patient's satisfaction with the treatment was evaluated. Additionally, operating times and complications were recorded. Radiological assessment for radiolucencies or implant migration was performed. The mean Constant score significantly increased from 35 points preoperatively to 62 points at the last follow-up (p<0.001). All subcomponents (pain, daily activity, ROM, strength) of the Constant score were significantly (p<0.001) higher at follow-up. Active flexion improved from 90° to 150° (p<0.001), active abduction from 78° to 120° (p<0.001), and active external rotation from 20° to 40° (p<0.001) between preoperative and last clinical assessment. Furthermore, 54% of the patients were very satisfied, 34% satisfied, and 12% unsatisfied. Operating times of the new stemless prosthesis were significantly shorter compared to a stemmed prosthesis. Over the follow-up period, all humeral head components were radiological centred, changing radiolucencies were detected; however no implant loosening occurred. Revision surgery for implant loosening only occurred in the metal-backed glenoid component with hollow screw fixation; otherwise no complication due to implant loosening was detected. The promising five-year results suggest that the concept of this stemless humeral head replacement might be an expedient alternative to existing shoulder replacements. Anatomical cutting of the humeral head and hollow screw fixation allow a familiar access to the glenoid combined with a shaft independent, less complex bone-sparing surgery along with shorter operating times and favourable revision situation


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 138 - 138
1 Sep 2012
Patel N Wright J Afsharpad A Bajekal R
Full Access

Background. There is much research on metal on metal hip resurfacing arthroplasty (HRA) but few studies have reported the outcome with respect to implant characteristics from non-specialist centres. Aim. To report the survival, clinical and radiological outcomes of a single surgeon series of HRA with an average follow-up of 5 years. Methods. All consecutive HRAs performed by a single surgeon between 2002–2010 at a district general hospital were examined clinically and radiologically. The median follow-up was 61 months (12–102). Clinical assessment included the Oxford Hip Score (OHS) and University of Los Angeles (UCLA) Activity Score. Radiological assessment included implant position and various bony changes. Survival was defined as a need for revision of either component. Results. There were 75 HRA procedures (59 patients): 70 Birmingham, 2 Conserve, 2 Adept and 1 ASR. The median age was 58 years (25–75) with 46.7% (35) male and 53.3% (40) female. 4.2% (3) patients were lost to follow-up. The mean acetabular and femoral implant sizes were 54.8mm (48–64) and 48.2mm (42–58) respectively. The mean acetabular and femoral inclination angle was 45.4° (20.8–75.2°) and 138° (133–149.5°) respectively. Survival rate was 92% with 6 revisions due to aseptic loosening (3) and fracture (3). These failures were all predominantly female (5) with significantly smaller mean acetabular (50mm, p=0.036) and femoral (43.3mm, p=0.038) implant sizes. Moreover, they had a higher mean acetabular inclination angle of 47.8° (p=0.27). The mean OHS was 43.5 (25–48) and the mean UCLA activity score was 6.7 (3–10). Radiological findings included heterotopic ossification in 21.6% (16), radiolucent lines in 6.8% (5), femoral neck thinning in 2.7% (2) and notching in 5.4% (4). Discussion. HRA has been shown to have comparable clinical and radiological short-medium term outcomes in a non-specialist centre using different implants. Failed procedure rate is high and patients were predominantly female, with significantly smaller implants and a higher acetabular inclination angle. Vigilance is therefore required in case selection and in follow-up for such patients


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 48 - 48
7 Nov 2023
Naidoo V Du Plessis J Milner B
Full Access

Distal radius fractures are common in South Africa. Accurate, decisive radiographic parameter interpretation is key in appropriate management. Digital radiographic facilities are rare in the public setting and goniometer usage is known to be low, thus, visual estimates are the primary form of radiographic assessment. Previous research associated orthopaedic experience with accuracy of distal radius fracture parameter estimation but, oftentimes, doctors treating orthopaedic patients are not experienced in orthopaedics.

A cross-sectional questionnaire including four distal radius fracture radiographs administered to 149 orthopaedic doctors at three Johannesburg teaching hospitals. Participants grouped into ranks of: consultants (n=36), registrars (n=41), medical officers (n=20) and interns (n=52). Participants visually estimated values of distal radius fracture parameters, stated whether they would accept the position of the fractures and stated their percentage of routine usage of goniometers in real practice.

The registrar group was most accurate in visually estimating radial height, whilst the interns were least accurate (p=0.0237). The consultant, registrar and medical officer groups were equally accurate in estimating radial inclination whilst the intern group was the least accurate (p<0.0001). The consultant and registrar group were equally accurate at estimating volar tilt, whilst the medical officer and intern groups were least accurate (p<0.0001). The Gwet's AC agreement was 0.1612 (p=0.047) for acceptance of position of the first radiograph, 0.8768 (p<0.0001) for the second, 0.8884 (p<0.0001) for the third and 0.8064 (p<0.0001) for the fourth. All groups showed no difference in goniometer usage, using them largely 0–25% of practice (p=0.1937).

The study found that accuracy in visual estimations of distal radius fracture parameters was linked to orthopaedic experience but not linked to routine practice goniometer usage, which was minimal across all groups. Inter-rater agreement on acceptability of fracture position is potentially dependent on severity of deviation from acceptable parameters.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 29 - 29
10 Feb 2023
Gupta A Jomaa M Ker A Hollman F Singh N Maharaj J Cutbush K
Full Access

Massive posterosuperior cuff tears (mRCT) retracted to the glenoid are surgically challenging and often associated with high retear rates. Primary repair is a less-favourable option and other salvage procedures such as SCR and tendon transfers are used. This study presents clinical and radiological outcomes of muscle advancement technique for repair of mRCT.

Sixty-one patients (mean age 57±6, 77% males and 23% females) (66 shoulders) underwent all-arthroscopic rotator cuff repair that included supraspinatus and infraspinatus subperiosteal dissection off scapular bony fossae, lateral advancement of tendon laminae, and tension-free double-layer Lasso Loop repair to footprint.

Pre-and post-operative range of motion (ROM), cuff strength, VAS, Constant, ASES, and UCLA scores were assessed. Radiologic assessment included modified Patte and Goutallier classifications. All patients had MRI at 6 months to evaluate healing and integrity of repair was assessed using Sugaya classification with Sugaya 4 and 5 considered retears.

Advanced fatty degeneration (Goutallier 3-4) was present in 44% and 20% of supraspinatus and infraspinatus. Tendon retraction was to the level of or medial to glenoid in 22%, and just lateral in 66%. 50.8% mRCT extended to teres minor. Subscapularis was partially torn (Lafosse 1-3) in 46% and completely torn (Lafosse 4-5) in 20%.

At mean follow-up (52.4 weeks), a significant increase in ROM, Relative Cuff Strength (from 57% to 90% compared to contralateral side), VAS (from 4 ±2.5 to 1±1.7), Constant (50±17.8 to 74 ±13.0), ASES (52 ±17.5 to 87 ±14.9), and UCLA (16± 4.9 to 30 ±4.9) scores were noted. There were six retears (10%), one failure due to P. acnes infection. 93% returned to pre-injury work and 89% of cases returned to pre-injury sport. Satisfaction rate was 96%.

Muscle advancement technique for mRCT is a viable option with low retear rates, restoration of ROM, strength, and excellent functional outcomes.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 24 - 24
1 Apr 2022
Giotikas D Guryel E
Full Access

Introduction

Stryde® lengthening nail has been recently withdrawn because of concerns about osteolysis and other bone lesions that have been observed early after implantation. The present study analyses the incidence and features of these bone lesions in our patients.

Materials and Methods

This is a retrospective review of a series of patients from two centres specializing in limb reconstruction. Inclusion criteria was a history of surgery with Stryde® lengthening nail with more than one year follow-up available.

All postoperative x-rays were and clinical notes were reviewed.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 72 - 72
1 Dec 2022
Kendal J Fruson L Litowski M Sridharan S James M Purnell J Wong M Ludwig T Lukenchuk J Benavides B You D Flanagan T Abbott A Hewison C Davison E Heard B Morrison L Moore J Woods L Rizos J Collings L Rondeau K Schneider P
Full Access

Distal radius fractures (DRFs) are common injuries that represent 17% of all adult upper extremity fractures. Some fractures deemed appropriate for nonsurgical management following closed reduction and casting exhibit delayed secondary displacement (greater than two weeks from injury) and require late surgical intervention. This can lead to delayed rehabilitation and functional outcomes. This study aimed to determine which demographic and radiographic features can be used to predict delayed fracture displacement.

This is a multicentre retrospective case-control study using radiographs extracted from our Analytics Data Integration, Measurement and Reporting (DIMR) database, using diagnostic and therapeutic codes. Skeletally mature patients aged 18 years of age or older with an isolated DRF treated with surgical intervention between two and four weeks from initial injury, with two or more follow-up visits prior to surgical intervention, were included. Exclusion criteria were patients with multiple injuries, surgical treatment with fewer than two clinical assessments prior to surgical treatment, or surgical treatment within two weeks of injury. The proportion of patients with delayed fracture displacement requiring surgical treatment will be reported as a percentage of all identified DRFs within the study period. A multivariable conditional logistic regression analysis was used to assess case-control comparisons, in order to determine the parameters that are mostly likely to predict delayed fracture displacement leading to surgical management. Intra- and inter-rater reliability for each radiographic parameter will also be calculated.

A total of 84 age- and sex-matched pairs were identified (n=168) over a 5-year period, with 87% being female and a mean age of 48.9 (SD=14.5) years. Variables assessed in the model included pre-reduction and post-reduction radial height, radial inclination, radial tilt, volar cortical displacement, injury classification, intra-articular step or gap, ulnar variance, radiocarpal alignment, and cast index, as well as the difference between pre- and post-reduction parameters. Decreased pre-reduction radial inclination (Odds Ratio [OR] = 0.54; Confidence Interval [CI] = 0.43 – 0.64) and increased pre-reduction volar cortical displacement (OR = 1.31; CI = 1.10 – 1.60) were significant predictors of delayed fracture displacement beyond a minimum of 2-week follow-up. Similarly, an increased difference between pre-reduction and immediate post reduction radial height (OR = 1.67; CI = 1.31 – 2.18) and ulnar variance (OR = 1.48; CI = 1.24 – 1.81) were also significant predictors of delayed fracture displacement.

Cast immobilization is not without risks and delayed surgical treatment can result in a prolong recovery. Therefore, if reliable and reproducible radiographic parameters can be identified that predict delayed fracture displacement, this information will aid in earlier identification of patients with DRFs at risk of late displacement. This could lead to earlier, appropriate surgical management, rehabilitation, and return to work and function.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 3 - 3
23 Feb 2023
Holzer L Finsterwald M Sobhi S Yates P
Full Access

This study aimed to analyze the effect of two different techniques of cement application: cement on bone surface (CoB) versus cement on bone surface and implant surface (CoBaI) on the short-term effect of radiolucent lines (RLL) in primary fully cemented total knee arthroplasties (TKA) with patella resurfacing.

379 fully cemented TKAs (318 patients) were included in this monocentric study. Preoperative and postoperative at week 4 and 12 month after surgery all patients had a clinical and radiological examination and were administered the Oxford Knee Score (OKS). Cement was applied in two different ways among the two study groups: cement on bone surface (CoB group) or cement on bone surface and implant surface (CoBaI group). The evaluation of the presence of RLL or osteolysis was done as previously described using the updated Knee Society Radiographic Evaluation System.

The mean OKS and range of motion improved significantly in both groups at the 4-week and 12-month follow-up, with no significant difference between the groups (CoB vs. CoBaI). RLL were present in 4.7% in the whole study population and were significantly higher in the CoBaI group (10.5%) at the 4-week follow-up. At the 12-month follow-up RLL were seen in 29.8% of the TKAs in the CoBaI group, whereas the incidence was lower in the CoB group (24.0% (n.s.)). There were two revisions in each group. None of these due to aseptic loosening.

Our study indicated that the application of bone cement on bone surface only might be more beneficial than onto the bone surface and onto the implant surface as well in respect to the short-term presence of RLL in fully cemented primary TKA.

The long-term results will be of interest, especially in respect to aseptic loosening and might guide future directions of bone cement applications in TKA.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 40 - 40
1 Apr 2019
Elkabbani M El-Sayed MA Tarabichi S Malkawi AS Schulte M
Full Access

Aim. The objective of this study was to evaluate the intermediate term clinical and radiological results of a new short stem hip implant. Methods. In 20 consecutive patients suffering from osteoarthritis with 25 affected hip joints (five cases were bilateral), the clinical and radiological results of 25 hip arthroplasties performed in one hospital between October 2009 and May 2014 through a minimally invasive anterolateral approach using a cementless short stem prosthesis type Aida and a cementless cup type Ecofit with a ceramic on ceramic pairing were evaluated prospectively. The median age of patients at time of surgery was 60 years (range, 42–71 years), 15 male (4 were bilateral) and 5 female patients (one was bilateral) were included in the study. The median clinical follow up was 30 months (range, 2–88 months), and the median radiological follow up was 30 months (range, 2–88 months). Results. Harris Hip Score improved from a median preoperative value of 53 to a median postoperative value of 96 (range, 73–100) at follow up. 22 hips (88%) showed an excellent postoperative Harris Hip Score, 2 hips (8%) a good postoperative Harris Hip Score, and one hip (4%) a fair postoperative Harris Hip Score. Only two patients complained of postoperative thigh pain. Regarding patient satisfaction, 15 patients (60%) were very satisfied, 10 patients (40%) were satisfied. None was unsatisfied. Radiological analysis showed that 19 stems (76%) were with stable bony ingrowth, two cases (8%) showed stable fibrous ingrowth. Four cases need further follow up for proper evaluation of stem fixation.(See Figures 1,2,3). Conclusion. The intermediate term survival of this new short stem is very promising, and achieving the goals of a standard hip arthroplasty. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 104 - 104
23 Feb 2023
Gupta V Zhou Y Manson J Watt J
Full Access

Surgical site infections (SSIs) after spinal fusion surgery increase healthcare costs, morbidity and mortality. Routine measures of obesity fail to consider site specific fat distribution. We aimed to assess the association between the spine adipose index and deep surgical site infection and determine a threshold value for spine adipose index that can assist in preoperative risk stratification in patients undergoing posterior instrumented lumbar fusion (PILF).

A multicentre retrospective case-control study was completed. We reviewed patients who underwent PILF from January 1, 2010 to December 31, 2018. All patients developing a deep primary incisional or organ-space SSI within 90 days of surgery as per US Centre for Disease Control and Prevention criteria were identified. We gathered potential pre-operative and intra-operative deep infection risk factors for each patient. Spine adipose index was measured on pre-operative mid-sagittal cuts of T2 weighted MRI scans. Each measurement was repeated twice by three authors in a blinded fashion, with each series of measurement separated by a period of at least six weeks.

Forty-two patients were included in final analysis, with twenty-one cases and twenty-one matched controls. The spine adipose index was significantly greater in patients developing deep SSI (p =0.029), and this relationship was maintained after adjusting for confounders (p=0.046). Risk of developing deep SSI following PILF surgery was increased 2.0-fold when the spine adipose index was ≥0.51. The spine adipose index had excellent (ICC >0.9; p <0.001) inter- and intra-observer reliabilities.

The spine adipose index is a novel radiographic measure and an independent risk factor for developing deep SSI, with 0.51 being the ideal threshold value for pre-operative risk stratification in patients undergoing PILF surgery.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 32 - 32
1 Dec 2022
Fransen B Bengoa F Neufeld M Sheridan G Garbuz D Howard L
Full Access

With the introduction of highly crosslinked polyethylene (HXLPE) in total hip arthroplasty (THA), orthopaedic surgeons have moved towards using larger femoral heads at the cost of thinner liners to decrease the risk of instability. Several short and mid-term studies have shown minimal liner wear with the use HXLPE liners, but the safety of using thinner HXPLE liners to maximize femoral head size remains uncertain and concerns that this may lead to premature failure exist. Our objective was to analyze the outcomes for primary THA done with HXLPE liners in patients who have a 36-mm head or larger and a cup of 52-mm or smaller, with a minimum of 10-year follow-up. Additionally, linear and volumetric wear rates of the HXLPE were evaluated in those with a minimum of seven-year follow-up. We hypothesized that there would be minimal wear and good clinical outcome.

Between 2000 and 2010, we retrospectively identified 55 patients that underwent a primary THA performed in a high-volume single tertiary referral center using HXLPE liners with 36-mm or larger heads in cups with an outer diameter of or 52-mm or smaller. Patient characteristics, implant details including liner thickness, death, complications, and all cause revisions were recorded. Patients that had a minimum radiographic follow-up of seven years were assessed radiographically for linear and volumetric wear. Wear was calculated using ROMAN, a validated open-source software by two independent researchers on anteroposterior X-rays of the pelvis.

A total of 55 patients were identified and included, with a mean age of 74.8 (range 38.67 - 95.9) years and a mean BMI of 28.98 (range 18.87 - 63-68). Fifty-one (94.4%) of patients were female. Twenty-six (47.7%) patients died during the follow-up period. Three patients were revised, none for liner wear, fracture or dissociation. Twenty-two patients had a radiographic follow-up of minimum seven years (mean 9.9 years, min-max 7.5 –13.7) and were included in the long-term radiographic analysis. Liner thickness was 5.5 mm at 45 degrees in all cases but one, who had a liner thickness of 4.7mm, and all patients had a cobalt-chrome head. Cup sizes were 52mm (n=15, 68%) and 50mm (n=7, 32%). Mean linear liner wear was 0.0470 mm/year (range 0 - 0.2628 mm) and mean volumetric wear was 127.69 mm3/year (range 0 - 721.23 mm3/year).

Using HXLPE liners with 36-mm heads or bigger in 52-mm cups or smaller is safe, with low rates of linear and volumetric wear in the mid to long-term follow-up. Patients did not require revision surgery for liner complications, including liner fracture, dissociation, or wear. Our results suggest that the advantages of using larger heads should outweigh the potential risks of using thin HXLPE liners.