Abstract
In the past century several shoulder reconstruction systems with different types of prostheses and fixation methods have been developed to improve shoulder arthroplasty, especially to cover a wide range of pathologies and revision situations. The aim of this prospective trial was to report clinical and radiological mid-term results of a stemless humeral head replacement with metaphyseal hollow screw fixation.
A consecutive series of 147 shoulders in 138 patients (84 female, 54 male; mean age of 67 years, range 40–84) undergoing stemless humeral head arthroplasty were considered for this single-centre trial. We prospectively followed 120 shoulders (40 hemi- and 80 total-arthroplasties) for an average of five years or until a reoperation. Patient's clinical and functional outcome was evaluated according to the Constant score and active range of motions (ROM) was measured. Patient's satisfaction with the treatment was evaluated. Additionally, operating times and complications were recorded. Radiological assessment for radiolucencies or implant migration was performed.
The mean Constant score significantly increased from 35 points preoperatively to 62 points at the last follow-up (p<0.001). All subcomponents (pain, daily activity, ROM, strength) of the Constant score were significantly (p<0.001) higher at follow-up. Active flexion improved from 90° to 150° (p<0.001), active abduction from 78° to 120° (p<0.001), and active external rotation from 20° to 40° (p<0.001) between preoperative and last clinical assessment. Furthermore, 54% of the patients were very satisfied, 34% satisfied, and 12% unsatisfied. Operating times of the new stemless prosthesis were significantly shorter compared to a stemmed prosthesis. Over the follow-up period, all humeral head components were radiological centred, changing radiolucencies were detected; however no implant loosening occurred. Revision surgery for implant loosening only occurred in the metal-backed glenoid component with hollow screw fixation; otherwise no complication due to implant loosening was detected.
The promising five-year results suggest that the concept of this stemless humeral head replacement might be an expedient alternative to existing shoulder replacements. Anatomical cutting of the humeral head and hollow screw fixation allow a familiar access to the glenoid combined with a shaft independent, less complex bone-sparing surgery along with shorter operating times and favourable revision situation.