Advertisement for orthosearch.org.uk
Results 1 - 14 of 14
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 51 - 51
1 Jul 2022
Bayley M Salar O Middleton S Mandalia V
Full Access

Abstract. Purpose. Recently several authors have suggested a correlation between posterior tibial slope (PTS) and sagittal stability of the knee. However, there is a lack of consensus in the literature relating to measurement, normal values and important values to guide treatment. We performed a systematic literature review looking at PTS and cruciate ligament surgery. Our aim was to define a gold standard measurement technique, determine normal ranges and important values for consideration during cruciate ligament surgery. Methods. Electronic searches of MEDLINE (PubMed), CINAHL, Cochrane, Embase, ScienceDirect, and NICE in June 2020 were completed. Inclusion criteria were original studies in peer-reviewed English language journals. A quality assessment of included studies was completed using the Methodological Index for Non-Randomized Studies (MINORS) Criteria. Results. Two-hundred and twenty-one papers were identified; following exclusions 34 papers were included for data collection. The mean MINORS score for non-comparative studies was 13.8 and for comparative studies 20.4, both indicating fair to good quality studies. A large variation in PTS measurement technique was identified, resulting in a wide range of values reported. In addition, there appears to be significant variation between different races, ages and genders. Conclusion. We demonstrated a lack of consensus in the literature relating to various facets of PTS. Cautiously, we suggest normal ranges of 6–12º using the proximal tibia axis at 5 and 15cms below the joint. Potentially 12º is an important cute-off for slope reducing osteotomy as an adjunct to revision ACL reconstruction


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 71 - 71
1 Jul 2022
Santini A Jamal J Wong P Lane B Wood A Bou-Gharios G Frostick S Roebuck M
Full Access

Abstract. Introduction. Risk factors for osteoarthritis include raised BMI and female gender. Whether these two factors influenced synovial gene expression was investigated using a triangulation and modelling strategy which generated 12 datasets of gene expression in synovial tissue from three knee pathologies with matching BMI groups, obese and overweight, and gender distributions. Methodology. Intra-operative synovial biopsies were immersed in RNAlater at 4oC before storage at -80oC. Total RNA was extracted using RNAeasy with gDNA removal. Following RT- PCR and quality assessment, cDNA was applied to Affymetrix Clariom D microarray gene chips. Bioinformatics analyses were performed. Linear models were prepared in limma with gender and BMI factors incorporated sequentially for each pathology comparison, generating 12 models of probes differentially expressed at FDR p<0.05 and Bayes number, B>0. Data analysis of differently expressed genes utilized Ingenuity Pathway Analysis and Cytoscape with Cluego and Cytohubba plug-ins. Results. Expression of 453 synovial genes was influenced by BMI and gender, 360 encode proteins such as HIF-1a, HSF1, HSPA4, HSPA5. Top canonical pathways include Unfolded protein response, Protein Ubiquiitation and Clathrin mediated endocytosis signalling linked by modulation of heat shock proteins, comparable to pathology dependent regulation. In addition BMI and gender modulate gene expression in the NRF2-mediated oxidative stress response pathway with down regulation of Glutathione-S-transferases potentially down regulating antioxidant defences. Conclusion. The enhanced risk of osteoarthritis induced by an elevated BMI and female gender maybe include differential expression of heat shock proteins and genes in the NRF2 pathway


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 68 - 68
1 Jul 2022
Jamal J Wong P Lane B Wood A Bou-Gharios G Santini A Frostick S Roebuck M
Full Access

Abstract. Introduction. It is increasingly evident that synovium may play a larger role in the aetiology of osteoarthritis. We compared gene expression in whole tissue synovial biopsies from end-stage knee osteoarthritis and knee trauma patients with that of their paired explant cultures to determine how accurately cultured cells represent holistic synovial function. Methodology. Synovial tissue biopsies were taken from 16 arthroplasty patients and 8 tibial plateau fracture patients with no osteoarthritis. Pairs of whole tissue fragments were either immediately immersed in RNAlater Stabilisation Solution at 4o C before transfer to -80o C storage until RNA extraction; or weighed, minced and cultured at 500mg tissues/5ml media in a humidified incubator at 37oC, 5% CO2. After sub-culturing total RNA was extracted using RNAeasy Plus Mini Kit with gDNA removal. Following RT-PCR and quality assessment, cDNA was applied to Affymetrix Clariom D microarray gene chips. Bioinformatics analyses were performed. Results. PCA analysis illustrates the clear separation of expression array data from cultured cells compared with their parental whole tissues and no segregation between cells derived from osteoarthritic or trauma tissues. A differentially expressed gene heat map demonstrated the hierarchical independence of cultured cells from their paired sample parental tissues. The biological pathways enriched by these gene expression differences emphasise the activities of macrophages and lymphocytes lost from culture. Conclusion. Adherent synovial cells grown from different knee pathologies lose the expression patterns characteristic of their originating pathology. Interpretation of data needs caution as the cells are not representative of whole synovium


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 70 - 70
1 Jul 2022
Wong P Jamal J Santini A Lane B Wood A Bou-Gharios G Frostick S Roebuck M
Full Access

Abstract. Introduction. Synovitis impacts osteoarthritis symptomatology and progression. The transcription factors controlling synovial gene expression have not been described. This study analyses gene expression in synovium samples from 16 patients with osteoarthritis with 9 undergoing arthroscopic and 8 knee trauma surgery for non-arthritic pathologies. Methodology. Intra-operative synovial biopsies were immersed in RNAlater at 4oC before storage at -80oC. Total RNA was extracted using RNAeasy. After purification, RT-PCR and quality assessment, cDNA was applied to Affymetrix Clariom D microarray gene chips. Bioinformatics analyses were performed. Linear models were prepared in limma with gender and BMI factors incorporated sequentially for each pathology comparison, generating 12 models of probes differentially expressed at FDR p<0.05 and Bayes number, B>0. Data analysis of differently expressed genes utilized Ingenuity Pathway Analysis and Cytoscape with Cluego and Cytohubba plug-ins. Results. Amongst the 2084 genes with significantly differential expression (DEG), 135 had transcription regulator capabilities and 121 a nuclear location. IPA analysis of OATKR and arthroscopic tissue comparison DEG identified 12 nuclear transcription factors linked to 31 DEG whose encoded proteins located within cytoplasmic and cell membrane compartments. All 12 were significantly up-regulated and acting in pathways up-regulating transcription of DNA and RNA, cell survival and angiogenesis while down-regulating senescence and apoptosis. NFE2L2, integral to the TGF-beta signalling pathway, was identified as a bottleneck gene. Conclusion. This analysis indicates the complexity of synovial gene expression regulation and offers target genes and pathways for evaluation during osteoarthritis pathogenesis


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1313 - 1322
1 Dec 2022
Yapp LZ Clement ND Moran M Clarke JV Simpson AHRW Scott CEH

Aims

The aim of this study was to assess factors associated with the estimated lifetime risk of revision surgery after primary knee arthroplasty (KA).

Methods

All patients from the Scottish Arthroplasty Project dataset undergoing primary KA during the period 1 January 1998 to 31 December 2019 were included. The cumulative incidence function for revision and death was calculated up to 20 years. Adjusted analyses used cause-specific Cox regression modelling to determine the influence of patient factors. The lifetime risk was calculated as a percentage for patients aged between 45 and 99 years using multiple-decrement life table methodology.


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 468 - 474
1 May 2024
d'Amato M Flevas DA Salari P Bornes TD Brenneis M Boettner F Sculco PK Baldini A

Aims

Obtaining solid implant fixation is crucial in revision total knee arthroplasty (rTKA) to avoid aseptic loosening, a major reason for re-revision. This study aims to validate a novel grading system that quantifies implant fixation across three anatomical zones (epiphysis, metaphysis, diaphysis).

Methods

Based on pre-, intra-, and postoperative assessments, the novel grading system allocates a quantitative score (0, 0.5, or 1 point) for the quality of fixation achieved in each anatomical zone. The criteria used by the algorithm to assign the score include the bone quality, the size of the bone defect, and the type of fixation used. A consecutive cohort of 245 patients undergoing rTKA from 2012 to 2018 were evaluated using the current novel scoring system and followed prospectively. In addition, 100 first-time revision cases were assessed radiologically from the original cohort and graded by three observers to evaluate the intra- and inter-rater reliability of the novel radiological grading system.


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 622 - 634
1 Jun 2023
Simpson CJRW Wright E Ng N Yap NJ Ndou S Scott CEH Clement ND

Aims

This systematic review and meta-analysis aimed to compare the influence of patellar resurfacing following cruciate-retaining (CR) and posterior-stabilized (PS) total knee arthroplasty (TKA) on the incidence of anterior knee pain, knee-specific patient-reported outcome measures, complication rates, and reoperation rates.

Methods

A systematic review of MEDLINE, PubMed, and Google Scholar was performed to identify randomized controlled trials (RCTs) according to search criteria. Search terms used included: arthroplasty, replacement, knee (Mesh), TKA, prosthesis, patella, patellar resurfacing, and patellar retaining. RCTs that compared patellar resurfacing versus unresurfaced in primary TKA were included for further analysis. Studies were evaluated using the Scottish Intercollegiate Guidelines Network assessment tool for quality and minimization of bias. Data were synthesized and meta-analysis performed.


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 87 - 97
1 Jan 2021
Burssens A De Roos D Barg A Welck MJ Krähenbühl N Saltzman CL Victor J

Aims. Patients with a deformity of the hindfoot present a particular challenge when performing total knee arthroplasty (TKA). The literature contains little information about the relationship between TKA and hindfoot alignment. This systematic review aimed to determine from both clinical and radiological studies whether TKA would alter a preoperative hindfoot deformity and whether the outcome of TKA is affected by the presence of a postoperative hindfoot deformity. Methods. A systematic literature search was performed in the databases PubMed, EMBASE, Cochrane Library, and Web of Science. Search terms consisted of “total knee arthroplasty/replacement” combined with “hindfoot/ankle alignment”. Inclusion criteria were all English language studies analyzing the association between TKA and the alignment of the hindfoot, including the clinical or radiological outcomes. Exclusion criteria consisted of TKA performed with a concomitant extra-articular osteotomy and case reports or expert opinions. An assessment of quality was conducted using the modified Methodological Index for Non-Randomized Studies (MINORS). The review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines and registered in the PROSPERO database (CRD42019106980). Results. A total of 17 studies were found to be eligible for review. They included six prospective and ten retrospective studies, and one case-control study. The effects of TKA showed a clinical improvement in the hindfoot deformity in three studies, but did not if there was osteoarthritis (OA) of the ankle (one study) or a persistent deformity of the knee (one study). The radiological alignment of the hindfoot corrected in 11 studies, but did not in the presence of a rigid hindfoot varus deformity (in two studies). The effects of a hindfoot deformity on TKA included a clinical association with instability of the knee in one study, and a shift in the radiological weightbearing axis in two studies. The mean MINORS score was 9.4 out of 16 (7 to 12). Conclusion. TKA improves both the function and alignment of the hindfoot in patients with a preoperative deformity of the hindfoot. This may not apply if there is a persistent deformity of the knee, a rigid hindfoot varus deformity, or OA of the ankle. Moreover, a persistent deformity of the hindfoot may adversely affect the stability and longevity of a TKA. These findings should be interpreted with caution due to the moderate methodological quality of the studies which were included. Therefore, further prospective studies are needed in order to determine at which stage correction of a hindfoot deformity is required to optimize the outcome of a TKA. Cite this article: Bone Joint J 2021;103-B(1):87–97


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 838 - 847
1 Jul 2019
Robinson PG Clement ND Hamilton D Blyth MJG Haddad FS Patton JT

Aims

Robotic-assisted unicompartmental knee arthroplasty (UKA) promises accurate implant placement with the potential of improved survival and functional outcomes. The aim of this study was to present the current evidence for robotic-assisted UKA and describe the outcome in terms of implant positioning, range of movement (ROM), function and survival, and the types of robot and implants that are currently used.

Materials and Methods

A search of PubMed and Medline was performed in October 2018 in line with the Preferred Reporting Items for Systematic Review and Meta-Analysis statement. Search terms included “robotic”, “knee”, and “surgery”. The criteria for inclusion was any study describing the use of robotic UKA and reporting implant positioning, ROM, function, and survival for clinical, cadaveric, or dry bone studies.


The Bone & Joint Journal
Vol. 99-B, Issue 8 | Pages 1053 - 1060
1 Aug 2017
Longo UG Ciuffreda M Casciaro C Mannering N Candela V Salvatore G Denaro V

Aims

Different methods of anterior cruciate ligament (ACL) reconstruction have been described for skeletally immature patients before closure of the growth plates. However, the outcome and complications following this treatment remain unclear. The aim of this systematic review was to analyse the outcome and complications of different techniques which may be used for reconstruction of the ACL in these patients.

Materials and Methods

We performed a systematic review of the literature according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. This involved a comprehensive search of PubMed, Medline, CINAHL, Cochrane, Embase and Google Scholar databases using the following combinations of keywords, “knee”, “anterior cruciate ligament”, “reconstruction”, “injury”, “children”, “adolescent”, “skeletally immature”, “open physis” and “surgery”.


Bone & Joint Research
Vol. 4, Issue 10 | Pages 163 - 169
1 Oct 2015
Barlow T Griffin D Barlow D Realpe A

Objectives

A patient-centred approach, usually achieved through shared decision making, has the potential to help improve decision making around knee arthroplasty surgery. However, such an approach requires an understanding of the factors involved in patient decision making. This review’s objective is to systematically examine the qualitative literature surrounding patients’ decision making in knee arthroplasty.

Methods

A systematic literature review using Medline and Embase was conducted to identify qualitative studies that examined patients’ decision making around knee arthroplasty. An aggregated account of what is known about patients’ decision making in knee arthroplasties is provided.


Bone & Joint Research
Vol. 3, Issue 10 | Pages 297 - 304
1 Oct 2014
Fitch DA Sedacki K Yang Y

Objectives

This systematic review and meta-analysis was conducted to determine the mid- to long-term clinical outcomes for a medial-pivot total knee replacement (TKR) system. The objectives were to synthesise available survivorship, Knee Society Scores (KSS), and reasons for revision for this system.

Methods

A systematic search was conducted of two online databases to identify sources of survivorship, KSS, and reasons for revision. Survivorship results were compared with values in the National Joint Registry of England, Wales, and Northern Ireland (NJR).


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1052 - 1061
1 Aug 2014
Thienpont E Schwab PE Fennema P

We conducted a meta-analysis, including randomised controlled trials (RCTs) and cohort studies, to examine the effect of patient-specific instruments (PSI) on radiological outcomes after total knee replacement (TKR) including: mechanical axis alignment and malalignment of the femoral and tibial components in the coronal, sagittal and axial planes, at a threshold of > 3º from neutral. Relative risks (RR) for malalignment were determined for all studies and for RCTs and cohort studies separately.

Of 325 studies initially identified, 16 met the eligibility criteria, including eight RCTs and eight cohort studies. There was no significant difference in the likelihood of mechanical axis malalignment with PSI versus conventional TKR across all studies (RR = 0.84, p = 0.304), in the RCTs (RR = 1.14, p = 0.445) or in the cohort studies (RR = 0.70, p = 0.289). The results for the alignment of the tibial component were significantly worse using PSI TKR than conventional TKR in the coronal and sagittal planes (RR = 1.75, p = 0.028; and RR = 1.34, p = 0.019, respectively, on pooled analysis). PSI TKR showed a significant advantage over conventional TKR for alignment of the femoral component in the coronal plane (RR = 0.65, p = 0.028 on pooled analysis), but not in the sagittal plane (RR = 1.12, p = 0.437). Axial alignment of the tibial (p = 0.460) and femoral components (p = 0.127) was not significantly different.

We conclude that PSI does not improve the accuracy of alignment of the components in TKR compared with conventional instrumentation.

Cite this article: Bone Joint J 2014; 96-B:1052–61.


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1057 - 1063
1 Aug 2013
Zeng Y Shen B Yang J Zhou ZK Kang PD Pei FX

The purpose of this study was to undertake a meta-analysis to determine whether there is lower polyethylene wear and longer survival when using mobile-bearing implants in total knee replacement when compared with fixed-bearing implants. Of 975 papers identified, 34 trials were eligible for data extraction and meta-analysis comprising 4754 patients (6861 knees). We found no statistically significant differences between the two designs in terms of the incidence of radiolucent lines, osteolysis, aseptic loosening or survival. There is thus currently no evidence to suggest that the use of mobile-bearing designs reduce polyethylene wear and prolong survival after total knee replacement.

Cite this article: Bone Joint J 2013;95-B:1057–63.