Gunshot-induced fractures of the
Resection of the
Advances in cancer therapy have prolonged cancer patient survival even in the presence of disseminated disease and an increasing number of cancer patients are living with metastatic bone disease (MBD). The
Advances in cancer therapy have prolonged patient survival even in the presence of disseminated disease and an increasing number of cancer patients are living with metastatic bone disease (MBD). The
Objective. To three-dimensionally reconstruct the
Introduction. The human body is a complex and continually adapting organism. It is theorised that the morphology of the
Introduction. Many uncemented femoral implant designs have had successful outcomes in total hip arthroplasty (THA). Different uncemented stem designs achieve initial and long term stability through shape, size, coating and fit. There is increasing emphasis on bone preservation, particularly in younger and more active patients. The desire to optimize load transfer has led to the development of short stems that seek to achieve fixation in the
BACKGROUND. In vitro tests have shown that when a force is applied to the
Aim. To review the results of patients who underwent fixation of complex proximal femur fractures using the
Introduction. Although total hip arthroplasty is a very successful operation, complications such as: dislocation, aseptic loosening, and periprosthetic fracture do occur. These aspects have been studied in large populations for traditional stem designs, but not for more recent short stems. The design rationale of short stems is to preserve bone stock, without compromising stability. However, due to their smaller bone contact area, high peak stresses and areas of stress shielding could appear in the
Slipped capital femoral epiphysis (SCFE) is traditionally treated with in situ fixation using a threaded screw, leading to physeal arrest while stabilizing the femoral head. Recently, there has been interest in alternative methods of fixation for SCFE, aiming to allow growth and remodelling of the femoral neck postoperatively. One such option is the Free Gliding SCFE Screw (Pega Medical), which employs a telescopic design intended to avoid physeal compression. The objective of this study is to evaluate radiographic changes of the
Bone-marrow oedema can occur both in isolation and in association with necrosis of bone, but it has not been shown whether each respond to the same methods of treatment. We treated 16 patients with isolated oedema and 17, in which it was associated with necrosis of the
Failure of cephalomedullary fixation for proximal femur fractures is an uncommon event associated with significant morbidity to the patient and cost to the healthcare system. This institution changed nailing system from the PFNA (DePuy Synthes) to InterTan (Smith and Nephew) in February 2020. To assess for non-inferiority, a retrospective review was performed on 247 patients treated for unstable proximal femur fractures (AO 31 A2; A3). Patients were identified through manual review of fluoroscopic images. Stable fracture patterns were excluded (AO 31 A1). Pre/post operative imaging, demographic data, operative time and ASA scores assessed. Internal/external imaging and national joint registry data were reviewed for follow up. No significant difference was found in overall failure rate of PFNA vs InterTan (4.84% vs 3.23%; p = 0.748). Overall, short nails were more likely to fail by cut-out than long nails (7.5% vs 1.2%; p = 0.015). Nails which failed by varus cut-out had a higher tip/apex distance (TAD) (26.2mm vs 17.0mm; p < 0.001). Of concern, varus cut-out occurred in two InterTan nails with TAD of <25mm. The PFNA enjoyed a shorter operative time for both the short (59.1 vs 71.8 mins; p = 0.022) and long nails (98.8 vs 114.3 mins; p = 0.016) with no difference in 120-day survival rate. Overall failure rates of the PFNA and InterTan nailing systems were comparable. However, the failure rate of short nails in this study is concerning. Using long nails with a lag screw design for unstable intertrochanteric femoral fractures may reduce failure rates. Cumulative frequency analysis suggests stringent tip-apex distances of less than 21mm may reduce failure rates in lag-screw design cephulomedullary nails. This dataset suggests that unstable intertrochanteric fractures may be more reliably managed with a long cephalomedullary device.
Introduction:. Extensive bone defects of the
Fractures of the
The integration of statistical shape models (SSMs) for generating a patient-specific model from sparse data is widely spread. The SSM needs to be initially registered to the coordinate-system in which the data is acquired and then be instantiated based on the point data using some regressing techniques such as principal component analysis (PCR). Besides PCR, partial least squares regression (PLSR) could also be used to predict a patient-specific model. PLSR combines properties of PCR and multiple linear regression and could be used for shape prediction based on morphological parameters. Both methods were compared on the basis of two SSMs, each of them constructed from 30 surface models of the
Controversy exists whether to treat unstable pertrochanteric hip fractures with either intra-medullary or extra-medullary devices. A prospective randomised control trial was performed to compare the outcome of unstable pertrochanteric hip fractures stabilised with either a sliding hip screw or long Gamma Nail. The hypothesis was that there is no difference in outcome between the two modes of treatment. Over a four year period, 210 patients presenting with an unstable pertrochanteric hip fracture (AO/OTA 31 A2) were recruited into the study. Eligible patients were randomised on admission to either long Gamma Nail or sliding hip screw. Follow-up was arranged for three, six, and twelve months. Primary outcome measures were implant failure or ‘cut-out’. Secondary measures included mortality, length of hospital stay, transfusion rate, change in mobility and residence, and EuroQol outcome score. Five patients required revision surgery for implant cut-out (2.5%), of which three were long Gamma Nails and two were sliding hip screws (no significant difference). There were no incidences of implant failure or deep infection. Tip apex distance was found to correlate with implant cut-out. There was no statistically significant difference in either the EuroQol outcome scores or mortality rates between the two groups when corrected for mini mental score. There was no difference in transfusion rates, length of hospital stay, and change in mobility or residence. There was a clear cost difference between the implants. The sliding hip screw remains the gold standard in the treatment of unstable pertrochanteric fractures of the
Lag screw cut-out following fixation of unstable intertrochanteric fractures in osteoporotic bone remains an unsolved challenge. A novel new device is the X-Bolt which is an expanding type bolt that may offer superior fixation in osteoporotic bone compared to the standard DHS screw type device. The aim of this study was to test if there was a difference in cut-out using the X-Bolt implant compared with the standard DHS systemIntroduction
Aims
Through the paediatric LCP Hip plating system (Synthes GmBH Eimattstrasse 3 CH- 4436 Oberdorff), the highly successful technique of the locking compression plate used in adult surgery, has been incorporated in a system dedicated to pediatrics. We are presenting the outcome of the paediatric LCP hip plating system used for a variety of indications in our institution. We retrospectively reviewed the notes and radiographs of all those children who have had Paediatric LCP Plate for the fixation of proximal femoral osteotomy and proximal femur fractures in our institution, between October 2007 and July 2010, for their clinical progress, mobilization status, radiological healing and any complications. Forty-three Paediatric LCP hip plates were used in forty patients (24 males and 13 females) for the fixation of proximal femoral osteotomies (n=40) and proximal femur fractures (n=3). The osteotomies were performed for a variety of indications including Perthes disease, developmental dysplasia of hip, Cerebral Palsy, Down's syndrome, coxa vara, Leg length discrepancy and previous failed treatment of Slipped Upper Femoral Epiphysis. Twenty-five children were allowed touch to full weight bearing post operatively. Two were kept non-weight bearing for 6 weeks. The remaining 13 children were treated in hip spica due to simultaneous pelvic osteotomy or multilevel surgery for cerebral palsy. All osteotomies and fractures radiologically healed within 6 months (majority [n=40] within 3 months). There was no statistically significant difference (p= 0.45) in the neck shaft angle between the immediately postoperative and final x-rays after completion of bone healing. Among the children treated without hip spica, 1 child suffered a periprosthetic fracture. Of the children treated in hip spica, 2 had pressure sores, 3 had osteoporotic distal femur fractures and 2 had posterior subluxations requiring further intervention. There were no implant related complications. The Paediatric LCP Hip Plate provides a stable and reliable fixation of the proximal femoral osteotomy performed for a variety of paediatric orthopaedic conditions.
Survival of sepsis has been documented worldwide, but little is documented about the long-term health outcomes of multifocal sepsis from acute musculoskeletal infection - the first study of its kind in New Zealand. Children admitted to the Paediatric Intensive Care Unit (PICU) from 1. st. January 2002 to 31. st. December 2017 with a musculoskeletal focus of infection were identified from hospital coding data. Notes review from discharge to present day determined survival and morbidity. Present-day clinical assessment of the musculoskeletal and respiratory systems along with questionnaires on health-related quality of life, mental health and sleep were performed. Seventy patients were studied. Seven children died acutely (five Pasifika and two Māori children) indicating 10% mortality. Long-term survival was favourable with no recorded deaths after discharge. Recurrence/chronic infection occurred in 23%, a mean of 1.1 year after discharge. Growth disturbance occurred in 18%, a mean of 3 years after discharge. The hip joint and