Low-energy fractures complications are a major public health issue that make osteoporosis even worse. In sub-Saharan Africa, the
Conferences centered around surgery suffers from gender disparity with male faculty having a more dominant presence in meetings compared to female faculty. Orthopedic Surgery possibly suffers the most from this problem of all surgical specialties, and is reflective of a gender disparity in the field. The objective of this study was to investigate the
Os acromiale is a developmental defect caused by failure of fusion of the anterior epiphysis of the acromion between the ages of 22 and 25. The
Adverse spinopelvic characteristics (ASC) have been associated with increased dislocation risk following primary total hip arthroplasty (THA). A stiff lumbar spine, a large posterior standing tilt when standing and severe sagittal spinal deformity have been identified as key risk factors for instability. It has been reported that the rate of dislocation in patients with such ASC may be increased and some authors have recommended the use of dual mobility bearings or robotics to reduce instability to within acceptable rates (<2%). The aims of the prospective study were to 1: Describe the true incidence of ASC in patients presenting for a THA 2. Assess whether such characteristics are associated with greater symptoms pre-THA due to the concomitant dual pathology of hip and spine and 3. Describe the early term dislocation rate with the use of ≤36mm bearings. This is an IRB-approved, two-center, multi-surgeon, prospective, consecutive, cohort study of 220 patients undergoing THA through anterolateral- (n=103; 46.8%), direct anterior- (n=104; 27.3%) or posterior- approaches (n=13; 5.9%). The mean age was 63.8±12.0 years (range: 27.7-89.0 years) and the mean BMI 28.0±5.0 kg/m. 2. (range: 19.4-44.4 kg/m. 2. ). There were 44 males (47.8%) and 48 females (52.2%). The mean follow-up was 1.6±0.5 years. Overall, 54% of femoral heads was 32 mm, and 46% was 36mm. All participants underwent lateral spinopelvic radiographs in the standing and deep-flexed seated positions were taken to determine lumbar lordosis (LL), sacral slope (SS), pelvic tilt (PT), pelvic-femoral angle (PFA) and pelvic incidence (PI) in both positions. Spinal stiffness was defined as lumbar flexion <20° when transitioning between the standing and deep-seated position; adverse standing PT was defined as >19° and adverse sagittal lumbar balance was defined as mismatch between standing PI and LL >10°. Pre-operative patient reported outcomes was measured using the Oxford Hip Score (OHS) and EuroQol Five-Dimension questionnaire (EQ-5D). Dislocation rates were prospectively recorded. Non-parametric tests were used, significance was set at p<0.05. The
Aim. At our tertiary orthopaedic centre, mycobacterial cultures are routinely performed on bone and joint samples sent for bacterial culture. We have previously described the
Aim. Surgical treatment of ankle fractures comes with a substantial risk of complications, including infection. An unambiguously definition of fracture-related infections (FRI) has been missing. Recently, FRI has been defined by a consensus group with a diagnostic algorithm containing suggestive and confirmatory criteria. The aim of the current study was to report the
Overall, hip and knee total joint replacement (TJR) patients experience marked benefit, with reported satisfaction rates of greater than 80% with regard to pain relief and improved function. However, many patients experience ‘nuisance’ symptoms, an annoyance which may cause discomfort, which can negatively impact postoperative satisfaction. The purpose of this study was to evaluate the
In the vast majority of patients, the anatomical and mechanical axes of the tibia in the coronal plane are widely accepted to be equivalent. This philosophy guides the design and placement of orthopaedic implants within the tibia and in both the knee and ankle joints. However, the presence of coronal tibial bowing may result in a difference between these two axes and hence cause suboptimal placement of implanted prostheses. Although the
Physical examination is critical to formation of a differential diagnosis in patients with ulnar-sided wrist pain. Although the specificity and sensitivity of some of those tests have been reported in the literature, the
Introduction. Studies have addressed the issue of increasing
Introduction. Excessive standing posterior pelvic tilt (PT), lumbar spine stiffness, low pelvic Incidence (PI), and severe sagittal spinal deformity (SSD) have been linked to increased dislocation rates. We aimed to compare the
Aim. Our aim was to evaluate the
Orthopaedic injuries in the knee are often associated with vascular injury. When these vascular injuries are missed devastating there are devastating outcomes like limb ablation. Pulse examination in these patients is not sensitive to exclude vascular injuries. That often lead to clinicians opting for Computed Tomography Angiogram (CTA) to exclude vascular. this usually leads to a burden in Radiology Department. This study aimed to evaluate the
Total Knee Arthroplasty (TKA) patients may present with effusion, pain, stiffness and functional impairment. A positive metal hypersensitivity (positive LTT) may be an indication for a revision surgery with a custom-made implant devoid of any hypersensitivity-related metal or an implant with the least possible ion content of the metal hypersensitivity, if no custom-made is available. The purpose of the current study is to assess the
Few epidemiological studies from Asian countries have addressed this issue and reported that FAI is less prevalent in Asian population. The purpose of this study was to determine the
Aim. Low-grade infections are difficult to diagnose. As the presence of a chronic infection requires extensive surgical debridement and antibiotic treatment, it is important to diagnose a SII prior to surgery, especially when the hardware is revised. We investigated whether serum inflammatory markers or nuclear imaging can accurately diagnose a chronic spinal instrumentation infection (SII) prior to surgery. Method. All patients who underwent revision spinal surgery after a scoliosis correction between 2017 and 2019 were retrospectively evaluated. The diagnostic accuracy of serum C-reactive protein (CRP) and Erythrocyte Sedimentation Rate (ESR), . 18. F-fluorodeoxyglucose positron emission tomography combined with computed tomography (FDG-PET/CT) and Technetium-99m-methylene diphosphonate (99mTc-MDP) 3-phase bone scintigraphy (TPBS) to diagnose infection were studied. Patients with an acute infection or inadequate culture sampling were excluded. SII was diagnosed if ≥ 2 of the same microorganism(s) were isolated from intra-operative tissue cultures. Results. 31 patients were included. The indication for hardware extraction was pseudoarthrosis in the majority of patients (n = 15). 22 patients (71%) were diagnosed with SII. In all infected cases, Cutibacterium acnes was isolated, including 5 cases with a polymicrobial infection. Sensitivity, specificity, PPV and NPV was: 4.5%, 100%, 100% and 30.0% for CRP >10.0 mg/L, 5.5%, 100%, 100% and 29% for ESR > 30 mm/h; 56%, 80%, 83% and 50% for FDG-PET/CT and 50%, 100%, 100% and 20% for TPBS, respectively. Conclusions. The
Purpose. Despite the increasing interest and subsequent published literature on hip resurfacing arthroplasty, little is known about the
INTRODUCTION:. Acetabular retroversion has been implicated as a risk factor for the development of early hip osteoarthritis. In clinical practice standard osseous signs such as the cross-over sign (COS) and the posterior wall sign (PWS) are widely used to establish the diagnosis of acetabular retroversion on plain radiographs. Despite standardized radiological evaluation protocols, an increased pelvic tilt can lead to a misdiagnosis of acetabular retroversion in AP radiographs and 2D MR or CT scans. Previous studies have shown that the elimination of observer bias using a standardized methodology based on 3D-CT models and the anterior pelvic plane (APP) for the assessment of COS and PWS results in greater diagnostic accuracy. Using this method a
Background of study. Numbness around the surgical scar can be a source of discomfort in patients undergoing Total Knee Arthroplasty (TKA). Literature reports wide variation in its
Numbness around the surgical scar can be a source of discomfort or dissatisfaction in a proportion of patients undergoing Total Knee Arthroplasty (TKA). Literature reports wide variation in its