Advertisement for orthosearch.org.uk
Results 1 - 11 of 11
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_18 | Pages 6 - 6
1 Nov 2016
Lim J Foster N Ridley D Johnston L Clift B
Full Access

The use of Birmingham hip resurfacing (BHR) remains controversial due to the increased revision rate in female patients. We compared the outcomes of BHR in female patients to an age matched total hip arthroplasty(THA) cohort. We reviewed the pain, function and total Harris Hip Scores(HHS), and Kaplan-Meir survivorship for BHR and THA cohorts from a prospective regional arthroplasty database. There were 234 patients in each cohort, with mean age of 51 years. The BHR cohort had significantly better function and total HHS at all points of the 5-year study, but not for the post-operative pain score. The 5-year revision rate for the BHR cohort was significantly higher than the THA cohort (6.8% vs 3.4%, p=0.001). The main reason for revision in the BHR cohort was aseptic loosening (n=8), followed by metallosis (n=3). The 5-year Kaplan-Meier survivorship was 92.6% (95% CI±1.7%) and 96.4% (95% CI±1.3%) for the BHR and THA cohort (p=0.001). BHR can give significantly better functional outcomes than THA. The vast majority of female patients were happy with BHR and did not need further surgery at the 5-year stage. This is somewhat at odds with the recent reputation of the procedure. The 10-year result of the same cohort is warranted to provide further data. Our study is not a recommendation to still offer BHR to female patients, but rather to inject a note of realism into the debate. There are implications for future implant development in that these results do validate resurfacing as a functionally valuable option for active patients


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 133 - 133
1 Sep 2012
Weston-Simons J Pandit H Haliker V Price A Dodd C Popat M Murray D
Full Access

Introduction. The peri-operative analgesic management of patients having either Total Knee Replacement (TKR) or Unicompartmental Knee Replacement (UKR) is an area that continues to have prominence, driven in part by the desire to reduce hospital stay, while maintaining high patient satisfaction. This is particularly relevant in the current climate of healthcare cost savings. We evaluated the role of “top up” intra-articular local anaesthetic injection after identifying that an appreciable number of patients in the unit suffered “breakthrough pain” on the first post-op day, when the effects of local analgesia are wearing off. Method. 43 patients, who were scheduled to have a cemented Oxford UKR, were prospectively recruited and randomised. All patients had the same initial anaesthetic regime of general anaesthesia, femoral nerve block and intra-operative intra-articular infiltration of the cocktail. All patients had a 16G multi-holed epidural catheter placed intra-articularly prior to wound closure. Patients had the same operative technique, post operative rehabilitation and rescue analgesia. An independent observer recorded post-operative pain scores using a visual analogue score (1–10) every 6 hours and any rescue analgesia that was required. On the morning after surgery, 22 patients, (Group I), received 20 mls of 0.5% bupivicaine through the catheter whilst 21 patients, (Group II), had 20 mls of normal saline by the same observer, (who was blinded to the contents of the solution being injected), after which the catheter was removed. Results. When comparing these two groups there was no statistical difference found in their pain scores on the day of operation. However, patients in Group I had a significantly better pain score initially post top up and then at 6 hours (2.4 (0–8) vs 5.7 (2–9), Mann-Whitney p<0.001). This cohort of patients required less rescue analgesia (22% vs 75%, Mann-Whitney p<0.001). In addition, Group I had statistically significant higher patient satisfaction outcome scores after the infiltration, (p<0.001), with 16 reporting very good satisfaction in comparison to 1 in Group II. There were no complications in either group. Discussion. Our study has shown that injection of local anaesthesia via an intra-articular catheter does reduce pain scores when compared to placebo. This implies that this technique may have a role in providing optimal pain relief after UKR


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1069 - 1073
1 Aug 2009
Hamid N Loeffler BJ Braddy W Kellam JF Cohen BE Bosse MJ

The purpose of this study was to compare the clinical and radiological outcome of patients with intact, broken and removed syndesmosis screws after Weber B or C ankle fracture with an associated injury to the syndesmosis. We hypothesised that there would be no difference. Of a possible 142 patients who fulfilled our inclusion criteria, 52 returned for clinical and radiological assessment at least one year after surgery. Of these, 27 had intact syndesmosis screws, ten had broken screws, and 15 had undergone elective removal of the screw. The mean American Orthopaedic Foot and Ankle Society ankle/hindfoot score was 83.07 (. sd. 13.59) in the intact screw group, 92.40 (. sd. 12.69) in the broken screw group, and 85.80 (. sd. 11.33) in the removed screw group (p = 0.0466). There was no difference in clinical outcome of patients with intact or removed syndesmotic screws. Paradoxically, patients with a broken syndesmosis screw had the best clinical outcome. Our data do not support the removal of intact or broken syndesmosis screws, and we caution against attributing post-operative ankle pain to breakage of the syndesmosis screw


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 836 - 841
1 Jun 2015
Jónsson BY Mjöberg B

A total of 20 patients with a depressed fracture of the lateral tibial plateau (Schatzker II or III) who would undergo open reduction and internal fixation were randomised to have the metaphyseal void in the bone filled with either porous titanium granules or autograft bone. Radiographs were undertaken within one week, after six weeks, three months, six months, and after 12 months.

The primary outcome measure was recurrent depression of the joint surface: a secondary outcome was the duration of surgery.

The risk of recurrent depression of the joint surface was lower (p < 0.001) and the operating time less (p < 0.002) when titanium granules were used.

The indication is that it is therefore beneficial to use porous titanium granules than autograft bone to fill the void created by reducing a depressed fracture of the lateral tibial plateau. There is no donor site morbidity, the operating time is shorter and the risk of recurrent depression of the articular surface is less.

Cite this article: Bone Joint J 2015; 97-B:836–41


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 956 - 962
1 Jul 2014
Ahearn N Oppy A Halliday R Rowett-Harris J Morris SA Chesser TJ Livingstone JA

Unstable bicondylar tibial plateau fractures are rare and there is little guidance in the literature as to the best form of treatment. We examined the short- to medium-term outcome of this injury in a consecutive series of patients presenting to two trauma centres. Between December 2005 and May 2010, a total of 55 fractures in 54 patients were treated by fixation, 34 with peri-articular locking plates and 21 with limited access direct internal fixation in combination with circular external fixation using a Taylor Spatial Frame (TSF). At a minimum of one year post-operatively, patient-reported outcome measures including the WOMAC index and SF-36 scores showed functional deficits, although there was no significant difference between the two forms of treatment. Despite low outcome scores, patients were generally satisfied with the outcome. We achieved good clinical and radiological outcomes, with low rates of complication. In total, only three patients (5%) had collapse of the joint of > 4 mm, and metaphysis to diaphysis angulation of greater than 5º, and five patients (9%) with displacement of > 4 mm. All patients in our study went on to achieve full union.

This study highlights the serious nature of this injury and generally poor patient-reported outcome measures following surgery, despite treatment by experienced surgeons using modern surgical techniques. Our findings suggest that treatment of complex bicondylar tibial plateau fractures with either a locking plate or a TSF gives similar clinical and radiological outcomes.

Cite this article: Bone Joint J 2014;96-B:956–62.


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 111 - 114
1 Jan 2013
Altay MA Ertürk C Altay N Öztürk IA Baykara I Sert C Isikan UE

We compared the intracompartmental pressures (ICPs) of open and closed tibial fractures with the same injury pattern in a rabbit model. In all, 20 six-month-old New Zealand White male rabbits were used. They were randomised into two equal groups of ten rabbits; an open fracture group (group 1) and a closed fracture group (group 2). Each anaesthetised rabbit was subjected to a standardised fracture of the proximal half of the right tibia using a custom-made device. In order to create a grade II open fracture in group 1, a 10 mm segment of fascia and periosteum was excised. The ICP in the anterior compartment was monitored at six-hourly intervals for 48 hours. Although there was a statistically significant difference in ICP values within each group (both p < 0.001), there was no significant difference between the groups for all measurements (all p ≥ 0.089). In addition, in both groups there was a statistically significant increase in ICP within the first 24 hours, whereas there was a statistically significant decrease within the second 24 hours (p < 0.001 for both groups). We conclude that open tibial fractures should be monitored for the development of acute compartment syndrome to the same extent as closed fractures.

Cite this paper: Bone Joint J 2013;95-B:111–14.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1488 - 1494
1 Nov 2007
Gorodetskyi IG Gorodnichenko AI Tursin PS Reshetnyak VK Uskov ON

We undertook a trial on 60 patients with AO 31A2 fractures of the hip who were randomised after stabilisation of the fracture into two equal groups, one of which received post-operative treatment using a non-invasive interactive neurostimulation device and the other with a sham device. All other aspects of their rehabilitation were the same. The treatment was continued for ten days after operation.

Outcome measurements included the use of a visual analogue scale for pain, the brief pain inventory and Ketorolac for post-operative control of pain, and an overall assessment of outcome by the surgeon. There were significantly better results for the patients receiving treatment by active electrical stimulation (repeated measures analysis of variance, p < 0.001). The findings of this pilot trial justify a larger study to determine if these results are more generally applicable.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 116 - 122
1 Jan 2010
Parker MI Pryor G Gurusamy K

We undertook a prospective randomised controlled trial involving 400 patients with a displaced intracapsular fracture of the hip to determine whether there was any difference in outcome between treatment with a cemented Thompson hemiarthroplasty and an uncemented Austin-Moore prosthesis. The surviving patients were followed up for between two and five years by a nurse blinded to the type of prosthesis used.

The mean age of the patients was 83 years (61 to 104) and 308 (77%) were women. The degree of residual pain was less in those treated with a cemented prosthesis (p < 0.0001) three months after surgery. Regaining mobility was better in those treated with a cemented implant (p = 0.005) at six months after operation. No statistically significant difference was found between the two groups with regard to mortality, implant-related complications, re-operations or post-operative medical complications.

The use of a cemented Thompson hemiarthroplasty resulted in less pain and less deterioration in mobility than an uncemented Austin-Moore prosthesis with no increase in complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 12 | Pages 1617 - 1622
1 Dec 2008
Axelrad TW Steen B Lowenberg DW Creevy WR Einhorn TA

Heterotopic ossification occurring after the use of commercially available bone morphogenetic proteins has not been widely reported. We describe four cases of heterotopic ossification in patients treated with either recombinant bone morphogenetic protein 2 or recombinant bone morphogenetic protein 7. We found that while some patients were asymptomatic, heterotopic ossification which had occurred around a joint often required operative excision with good results.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1073 - 1078
1 Aug 2008
Little NJ Verma V Fernando C Elliott DS Khaleel A

We compared the outcome of patients treated for an intertrochanteric fracture of the femoral neck with a locked, long intramedullary nail with those treated with a dynamic hip screw (DHS) in a prospective randomised study.

Each patient who presented with an extra-capsular hip fracture was randomised to operative stabilisation with either a long intramedullary Holland nail or a DHS. We treated 92 patients with a Holland nail and 98 with a DHS. Pre-operative variables included the Mini Mental test score, patient mobility, fracture pattern and American Society of Anesthesiologists grading. Peri-operative variables were anaesthetic time, operating time, radiation time and blood loss. Post-operative variables were time to mobilising with a frame, wound infection, time to discharge, time to fracture union, and mortality.

We found no significant difference in the pre-operative variables. The mean anaesthetic and operation times were shorter in the DHS group than in the Holland nail group (29.7 vs 40.4 minutes, p < 0.001; and 40.3 vs 54 minutes, p < 0.001, respectively). There was an increased mean blood loss within the DHS group versus the Holland nail group (160 ml vs 78 ml, respectively, p < 0.001). The mean time to mobilisation with a frame was shorter in the Holland nail group (DHS 4.3 days, Holland nail 3.6 days, p = 0.012). More patients needed a post-operative blood transfusion in the DHS group (23 vs seven, p = 0.003) and the mean radiation time was shorter in this group (DHS 0.9 minutes vs Holland nail 1.56 minutes, p < 0.001). The screw of the DHS cut out in two patients, one of whom underwent revision to a Holland nail. There were no revisions in the Holland nail group. All fractures in both groups were united when followed up after one year.

We conclude that the DHS can be implanted more quickly and with less exposure to radiation than the Holland nail. However, the resultant blood loss and need for transfusion is greater. The Holland nail allows patients to mobilise faster and to a greater extent. We have therefore adopted the Holland nail as our preferred method of treating intertrochanteric fractures of the hip.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1210 - 1217
1 Sep 2007
Peyser A Weil YA Brocke L Sela Y Mosheiff R Mattan Y Manor O Liebergall M

Limited access surgery is thought to reduce post-operative morbidity and provide faster recovery of function. The percutaneous compression plate (PCCP) is a recently introduced device for the fixation of intertrochanteric fractures with minimal exposure. It has several potential mechanical advantages over the conventional compression hip screw (CHS). Our aim in this prospective, randomised, controlled study was to compare the outcome of patients operated on using these two devices.

We randomised 104 patients with intertrochanteric fractures (AO/OTA 31.A1–A2) to surgical treatment with either the PCCP or CHS and followed them for one year postoperatively.

The mean operating blood loss was 161.0 ml (8 to 450) in the PCCP group and 374.0 ml (11 to 980) in the CHS group (Student’s t-test, p < 0.0001). The pain score and ability to bear weight were significantly better in the PCCP group at six weeks post-operatively. Analysis of the radiographs in a proportion of the patients revealed a reduced amount of medial displacement in the PCCP group (two patients, 4%) compared with the CHS group (10 patients, 18.9%); Fisher’s exact test, p < 0.02.

The PCCP device was associated with reduced intra-operative blood loss, less postoperative pain and a reduced incidence of collapse of the fracture.