Aims. The aim of this study was to identify patient- and surgery-related
risk factors for sustaining an early periprosthetic fracture following
primary total hip arthroplasty (THA) performed using a double-tapered
cementless femoral component (Bi-Metric femoral stem; Biomet Inc.,
Warsaw, Indiana). Patients and Methods. A total of 1598 consecutive hips, in 1441 patients receiving
primary THA between January 2010 and June 2015, were retrospectively
identified. Level of pre-operative osteoarthritis, femoral Dorr
type and cortical index were recorded. Varus/valgus placement of
the stem and canal fill ratio were recorded post-operatively. Periprosthetic
fractures were identified and classified according to the Vancouver
classification. Regression analysis was performed to identify risk
factors for early periprosthetic fracture. Results. The mean follow-up was 713 days (1 to 2058). A total of 48 periprosthetic
fractures (3.0%) were identified during the follow-up and median
time until fracture was 16 days, (interquartile range 10 to 31.5).
Patients with femoral Dorr type C had a 5.2 times increased risk
of
The accurate reconstruction of hip anatomy and
biomechanics is thought to be important in achieveing good clinical
outcomes following total hip arthroplasty (THA). To this end some
newer hip designs have introduced further modularity into the design
of the femoral component such that neckshaft angle and anteversion,
which can be adjusted intra-operatively. The clinical effect of
this increased modularity is unknown. We have investigated the changes
in these anatomical parameters following conventional THA with a
prosthesis of predetermined neck–shaft angle and assessed the effect
of changes in the hip anatomy on clinical outcomes. . In total, 44 patients (mean age 65.3 years (standard deviation
(. sd. ) 7); 17 male/27 female; mean body mass index 26.9 (kg/m²)
(. sd. 3.1)) underwent a pre- and
Introduction. In recent years the relationship between hyponatraemia and bone metabolism, falls and fractures has become more established. In this study hyponatraemia was an independent risk factor for increased
It has been suggested that cemented fixation of total hip arthroplasty
(THA) is associated with an increased peri-operative mortality compared
with cementless THA. Our aim was to investigate this through a nationwide
matched cohort study adjusting for age, comorbidity, and socioeconomic
background. A total of 178 784 patients with osteoarthritis who underwent
either cemented or cementless THA from the Swedish Hip Arthroplasty
Register were matched with 862 294 controls from the general population.
Information about the causes of death, comorbidities, and socioeconomic
background was obtained. Mortality within the first 90 days after
the operation was the primary outcome measure.Aims
Patients and Methods
Introduction. A recent paper suggested implanting an uncemented acetabular shell which is 6mm or greater than the native femoral head in total hip arthroplasty (THA) significantly increased the risk of postoperative pain. We retrospectively analyzed 265 Delta ceramic-on-ceramic (DCoC) THA comparing the native femoral head size to the implanted shell and reviewing if the patient suffered with
We carried out a retrospective cohort study of 3309 patients undergoing primary total hip replacement to examine the impact of tobacco use and body mass index on the length of stay in hospital and the risk of short term
Autologous retransfusion and no-drainage are
both blood-saving measures in total hip replacement (THR). A new combined
intra- and
Introduction. In rheumatoid (RA) patients undergoing total joint arthroplasty, evidence suggests methotrexate should be continued without increase in
Malnutrition is a potentially modifiable risk factor that may contribute to complications following geriatric hip fracture surgery. The purpose of this study was to investigate the association between preoperative hypoalbuminemia, a marker for malnutrition, and complications during the thirty days following surgery for geriatric hip fracture. The American College of Surgeons National Surgical Quality Improvement Program was used to conduct a retrospective cohort study of geriatric patients (>65 years) undergoing surgery for hip fracture. Patients without preoperative serum albumin concentration were excluded. Outcomes were compared between patients with and without hypoalbuminemia (defined as serum albumin concentration <3.5g/dL). All comparisons were adjusted for baseline differences between populations. 17,651 Patients were identified. Of these, 8,272 (46.9%) underwent hemiarthroplasty, 759 (4.3%) total joint arthroplasty, 324 (1.9%) percutaneous fixation, 2,445 (13.9%) plate/screw fixation, and 5,833 (33.1%) intramedullary fixation. The prevalence of hypoalbuminemia was 45.9% (Figure 1). The risk for death was strongly associated with serum albumin concentration, with a linear increase in risk observed as albumin fell below 3.5 g/dL (p<0.001; Figure 2). Following adjustment for all demographic, comorbidity, and procedural characteristics, patients with hypoalbuminemia had higher rates of death (9.94% versus 5.53%, adjusted relative risk [RR]=1.54, p<0.001), pneumonia (5.30% versus 3.77%, adjusted RR=1.20, p=0.012), sepsis (1.19% versus 0.53%, adjusted RR=1.90, p<0.001), and hospital readmission (10.91% versus 9.03%, adjusted RR=1.11, p<0.036; Table 1). The present study suggests that hypoalbuminemia is a powerful independent risk factor for death following surgery for geriatric hip fracture. This association persists over-and-above any associations of death with age, sex, body mass index, and comorbidities. Based on these data, we propose that the nutritional status of hip fracture patients should receive greater attention, and that randomized trials testing for efficacy of aggressive postoperative nutritional interventions may be warranted. For any figures or tables, please contact the authors directly by clicking on ‘Info & Metrics’ above to access author contact details.
Acetabular component positioning is commonly referenced with the pelvis in the supine position in direct anterior approach THA. Changes in pelvic tilt (PT) from the pre-operative supine to the
Venous thromboembolism (VTE) is a preventable cause of morbidity and mortality in patients undergoing elective hip arthroplasty surgery. The balance of
We investigated the revision rates of primary total hip replacement (THR) reported in the National Joint Registry (NJR) by types of bearing surfaces used. We analysed THR procedures across all orthopaedic units in England and Wales. Our analyses estimated all-cause and cause-specific revision rates. We identified primary THRs with heads and monobloc cups or modular acetabular component THRs with head and shell/liner combinations. We used flexible parametric survival models to estimate adjusted hazard ratios (HR). A total of 1,026,481 primary THRs performed between 2003–2019 are included in the primary analysis (Monobloc: n=378,979 and Modular: n=647,502) with 20,869 (2%) of these primary THRs subsequently undergoing a revision episode (Monobloc: n=7,381 and Modular: n=13,488). Compared to implants with a cobalt chrome head and highly crosslinked polyethylene (HCLPE) cup, the all-cause risk of revision for monobloc acetabular implant was higher for patients with cobalt chrome or stainless steel head and non-HCLPE cup. The risk of revision was lower for patients with a delta ceramic head and HCLPE cup implant, at any
Hip bearing surfaces materials are typically broadly reported in national registry (metal-on-polyethylene, ceramic-on-ceramic etc). We investigated the revision rates of primary total hip replacement (THR) reported in the National Joint Registry (NJR) by detailed types of bearing surfaces used. We analysed THR procedures across all orthopaedic units in England and Wales. Our analyses estimated all-cause and cause-specific revision rates. We identified primary THRs with heads and monobloc cups or modular acetabular component THRs with detailed head and shell/liner bearing material combinations. We used flexible parametric survival models to estimate adjusted hazard ratios (HR). A total of 1,026,481 primary THRs performed between 2003–2019 were included in the primary analysis (Monobloc cups: n=378,979 and Modular cups: n=647,502) with 20,869 (2%) of these primary THRs subsequently undergoing a revision episode (Monobloc: n=7,381 and Modular: n=13,488). Compared to implants with a cobalt chrome head and highly crosslinked polyethylene (HCLPE) cup, the overall risk of revision for monobloc acetabular implant was higher for patients with cobalt chrome or stainless steel head and non-HCLPE cup. The risk of revision was lower for patients with a delta ceramic head and HCLPE cup implant, at any
The postoperative pain after hip arthroscopy remains a major challenge in the immediate postoperative period. Adequate postoperative analgesia has been associated with increased patient satisfaction and decreased consumption of opioids. We evaluated the efficacy of pericapsular nerve group block (PENG) versus fascia iliaca block (FIB) in reducing
The significance of periprosthetic fractures about a total hip arthroplasty (THA) is becoming increasingly important. Recent studies have demonstrated
The MAKO Robotic arm is a haptic robotic system that can be used to optimise performance during total hip arthroplasty (THA). We present the outcome of the first 40 robotic cases performed in an NHS foundation trust along with the technique of performing robotic THA in our unit. Forty consecutive patients undergoing robotic THA (rTHA) were compared to a case matched group of patients undergoing manual THA (m-THA). 2:1 blinded case matching was performed for age, sex, implants used (Trident uncemented socket and cemented Exeter stem, Stryker Mahwah, NJ, US) and surgeon grade. Comparisons were made for radiological positioning of implants, including leg length assessment, and patient reported functional outcome (PROMS). Pre- and
Disease specific or generic Patient Reported Outcome Measures (PROMs) can be completed by patients using paper and postal services (pPROMS) or via computer, tablet or smartphone (ePROMs) or by hybrid data collection, which uses both paper and electronic questionnaires. We have investigated whether there are differences in scores depending on the method of PROMs acquisition for the Oxford Hip Score (OHS) and the EQ-5D scores, at one and two years post operatively. Patients for this study were identified retrospectively from a prospectively compiled arthroplasty database held at the study centre. Patient demographics, mode of preferred data collection and pre- and
Competitive dancers represent a unique patient population in the setting of hip arthroplasty given the high degree of hip strength and mobility required by their profession. We sought to determine the clinical outcomes and ability to return to competitive dance after total hip arthroplasty (THA) or hip resurfacing arthroplasty (HRA) among competitive dancers. Active competitive dancers who underwent primary THA or HRA at a single institution with minimum one-year follow-up were included in the study. Primary outcomes included (1) the rate of return to competitive dance, (2) three PROMs (modified Harris Hip Score [mHHS], Hip Disability and Osteoarthritis Outcome Score for Joint Replacement [HOOS-JR], and Lower Extremity Activity Scale [LEAS]), and (3)
Identification of patients at risk of not achieving minimally clinically important differences (MCID) in patient reported outcome measures (PROMs) is important to ensure principled and informed pre-operative decision making. Machine learning techniques may enable the generation of a predictive model for attainment of MCID in hip arthroscopy. Aims: 1) to determine whether machine learning techniques could predict which patients will achieve MCID in the iHOT-12 PROM 6 months after arthroscopic management of femoroacetabular impingement (FAI), 2) to determine which factors contribute to their predictive power. Data from the UK Non-Arthroplasty Hip Registry database was utilised. We identified 1917 patients who had undergone hip arthroscopy for FAI with both baseline and 6 month follow up iHOT-12 and baseline EQ-5D scores. We trained three established machine learning algorithms on our dataset to predict an outcome of iHOT-12 MCID improvement at 6 months given baseline characteristics including demographic factors, disease characteristics and PROMs. Performance was assessed using area under the receiver operating characteristic (AUROC) statistics with 5-fold cross validation. The three machine learning algorithms showed quite different performance. The linear logistic regression model achieved AUROC = 0.59, the deep neural network achieved AUROC = 0.82, while a random forest model had the best predictive performance with AUROC 0.87. Of demographic factors, we found that BMI and age were key predictors for this model. We also found that removing all features except baseline responses to the iHOT-12 questionnaire had little effect on performance for the random forest model (AUROC = 0.85). Disease characteristics had little effect on model performance. Machine learning models are able to predict with good accuracy 6-month