Aims. The optimum clearance between the bearing surfaces of hip arthroplasties is unknown. Theoretically, to minimize wear, it is understood that clearances must be low enough to maintain optimal contact pressure and fluid film lubrication, while being large enough to allow lubricant recovery and reduce contact patch size. This study aimed to identify the relationship between diametrical clearance and volumetric wear, through the analysis of retrieved components. Methods. A total of 81 metal-on-metal
Objectives. Previous studies have suggested that metal-on-metal (MoM)
Aims. To determine ten-year failure rates following 36 mm metal-on-metal
(MoM)
Objectives. Porous metal surfaces have been a popular option for acetabular component fixation in total hip arthroplasty (THA). New THA component designs are introduced periodically with the expectation of better wear properties and survivorship. Since its approval for use in 2002 there have been few clinical outcome studies published on the
Aims. The aim of this study was to determine whether the rates of revision
for metal-on-metal (MoM) total hip arthroplasties (THAs) with Pinnacle
components varied according to the year of the initial operation,
and compare these with the rates of revision for other designs of
MoM THA. Patients and Methods. Data from the National Joint Registry for England and Wales included
36 mm MoM THAs with
Background. One of the potential complications of polyethylene liner (PL) is its dissociation from the metal shell. This is a rare but catastrophic complication of total hip replacement (THR). Objective. was to analyze the retrieved dissociated components (PL and shell) (Depuy
This study utilized data from the NJR dataset on all Corail/
Aims. Our aim was to report survivorship data and lessons learned with
the Corail/
Background. Large head metal on metal total hip arthroplasty MOM THA have been consistently shown substantial improvement in wear performance compared with metal on polyethylene articulations. Large diameter femoral heads theoretically can reduce dislocation risk by increasing range of motion before impingement, increasing prosthetic jump distance. However, early failure associated with adverse local tissue reactions (ALTRs) to metal debris is an emerging problem after MOM THA. The purpose of this study was to evaluate mid-term results of MOM THA. Materials and Methods. Twenty-five patients, 28 hips were included in this study. The average age of the patients at the time of surgery was 66.9 years. Three patients were men and 22 were women. MOM THAs were performed using 28
Introduction. Numerous studies have reported on clinically significant volumes of material loss and corrosion at the head-stem junction of metal-on-metal (MOM) hips; less is understood about metal-on-polyethylene (MOP) hips. We compared the effect of bearing type (MOM vs MOP) on taper material loss for a hip system of a single design (DePuy Pinnacle). Methods. We recruited retrieved MOM (n=30) and MOP (n=22) bearing hips that were consecutively received at our centre. We prospectively collected associated clinical and imaging data. We measured the severity of corrosion and volumes of material loss at each head taper surface and used multivariate statistical analysis to investigate differences between the two bearing types. Results. The median rate of material loss for the MOM and MOP groups was 0.81 mm. 3. /year (0.01–3.45) and 0.03 mm. 3. /year (0–1.07) respectively (p<0.001). 29 out of 30 MOM hips were revised for adverse metal reactions, compared with 1 out of 22 MOP hips. Discussion. MOP hips lost significantly less material from their taper junctions than MOM hips. We suggest that the metal-metal interaction at the bearing surface of MOM hips enhances the corrosive environment at the head-stem junction. Conclusion. Our results can reassure patients with MOP
There is little evidence on the cost effectiveness
of different brands of hip prostheses. We compared lifetime cost effectiveness
of frequently used brands within types of prosthesis including cemented
(Exeter V40 Contemporary, Exeter V40 Duration and Exeter V40 Elite
Plus Ogee), cementless (Corail
Total hip arthroplasty (THA) has proved to be an effective treatment modality for sickle-cell hip arthropathy (mosaic-like dense bone due to infarcts). However, mode of failure, survival rates and challenges associated with revision hip arthroplasty in sickle-cell disease patients are mostly unknown. We retrospectively evaluated prospectively collected data from all patients with sickle-cell disease who underwent revision hip arthroplasty from 2016. Patient, surgery, medical and surgical complications related data were collected. The
Variations in component positioning of total hip replacements can lead to edge loading of the liner, and potentially affect device longevity. These effects are evaluated using ISO 14242:4 edge loading test results in a dynamic system. Mediolateral translation of one of the components during testing is caused by a compressed spring, and therefore the kinematics will depend on the spring stiffness and damping coefficient, and the mass of the translating component and fixture. This study aims to describe the sensitivity of the liner plastic strain to these variables, to better understand how tests using different simulator designs might produce different amounts of liner rim deformation. A dynamic explicit deformable finite element model with 36mm
Aims. “Get It Right First Time” (GIRFT) and NHS England’s Best Practice Tariff (BPT) have published directives advising that patients over the ages of 65 (GIRFT) and 69 years (BPT) receiving total hip arthroplasty (THA) should receive cemented implants and have brought in financial penalties if this policy is not observed. Despite this, worldwide, uncemented component use has increased, a situation described as a ‘paradox’. GIRFT and BPT do, however, acknowledge more data are required to support this edict with current policies based on the National Joint Registry survivorship and implant costs. Methods. This study compares THA outcomes for over 1,000 uncemented Corail/
In a cross sectional cohort study three different metal on metal total hip systems were assessed. Two monoblock acetabular designs; the Durom socket (Zimmer, Warsaw, In) and the Birmingham socket (Smith and Nephew, Memphis, TN), and one modular metal on metal total hip system (Pinnacle, Depuy Orthopaedics, Warsaw, In) in patients who have received these implants in the our region. 56 patients were recruited in total. All patients were assessed clinically, radiologically and biochemically. Whole blood Cobalt, Chromium and titanium levels were tested. The median head size used in the Birmingham group was 52mm (Range 44mm to 56mm), and in the Durom group, 48mm (Range 42 to 54mm). The median head size used in the modular
This study used model-based radiostereometric analysis (MBRSA) to compare migration of a recently introduced cementless hip stem to an established hip stem of similar design. Novel design features of the newer hip stem included a greater thickness of hydroxyapatite coating and a blended compaction extraction femoral broach. Fifty-seven patients requiring primary total hip arthroplasty (THA) were enrolled at a single centre. Patients were randomized to receive either an Avenir collarless stem and Trilogy IT cup (ZimmerBiomet) or a Corail collarless stem and
Purpose. To determine whether there is a difference in the metal ion levels among three different metal-on-metal total hip systems: two monoblock large heads and one modular metal-on-metal total hip replacement system in patients who received these implants in our region. Method. A group of 56 patients were recruited that had either undergone total hip replacement (THR) with a Birmingham resurfacing socket, the Durom resurfacing socket, or a
We conducted a retrospective study to assess
the prevalence of adverse reactions to metal debris (ARMD) in patients
operated on at our institution with metal-on-metal (MoM) total hip
replacements with 36 mm heads using a
Introduction and Aims. There are many surgical, implant design and patient factors that should be considered in preclinical testing of hip replacement which are not being considered in current standards. The aim of this study was to develop a preclinical testing method that consider surgical positioning, implant design and patient factors and predict the occurrence and severity of edge loading under the combination of such conditions. Then, assess the safety and reliability of the implant by predicting the wear, deformation and damage of the implant bearings under worst case conditions. Methods. Ceramic-on-ceramic (CoC, 36mm, BIOLOX. ®. delta,
Purpose of the study. We reviewed one hundred and twenty patients who had primary total hip replacement using Corail/