PROBLEM. Since the COVID-19 pandemic of 2020, there has been a marked rise in the use of telemedicine to evaluate patients following total knee arthroplasty (TKA). Telemedicine is helpful to maintain patient contact, but it cannot provide objective functional TKA data. External monitoring devices can be used, but in the past have had mixed results due to patient compliance and data continuity, particularly for monitoring over numerous years. This novel stem is a translational product with an embedded sensor that can remotely monitor patient activity following TKA. SOLUTION. The Canturio™ TE∗ System (Canary Medical) functions structurally as a tibial extension for the Persona® cemented tibial plate (Zimmer Biomet). The stem is instrumented with internal motion sensors (3-D accelerometer and gyroscope) and telemetry that collects and transmits kinematic data. Raw data is converted by analytics into clinically relevant gait metrics using a proprietary algorithm. The Canturio™ TE∗ will monitor the patient's gait daily for the first year and then with lower frequency thereafter to conserve battery power enabling the potential for 20 years of longitudinal data collection and analysis. A base station in the OR activates the device and links the stem and data to the patient. A base station in the patient's home collects and uploads data to the Cloud Based Canary Data Management Platform (Canary Medical). The Canary Cloud is structured as an FDA regulated and HIPPA-compliant database with cybersecurity protocols integrated into the architecture. A third base station is an accessory used in the health care professional's office to perform an on-demand gait analysis of a patient. A dashboard allows the health care professional and patient to monitor objective data of the patient's activity and progress post treatment. MARKET. The early target market for this device includes total joint surgeons who are early adopters of technology and currently utilize technology in their practice. The kinematic data provided by the Canturio™ TE∗ System will enable clinicians to augment patient care by reviewing their objective gait metrics. In the future, this data has the potential to be integrated with other Zimmer Biomet technologies, such as the Rosa™ Knee robotic platform, mymobility™, and sensored devices like iAssist™, to provide the surgeon with a complete pre-surgical functional assessment, intraoperative data, and post-operative functional data. PRODUCT.
BACKGROUND. Trochlear geometry of modern femoral implants is designed for the mechanical alignment (MA) technique for Total Knee Arthroplasty (TKA). The biomechanical goal is to create a proximalised and more valgus trochlea to better capture the patella and optimize tracking. In contrast, Kinematic alignment (KA) technique for TKA respects the integrity of the soft tissue envelope and therefore aims to restore native articular surfaces, either femoro-tibial or femoro-patellar. Consequently, it is possible that current implant designs are not suitable for restoring patient specific trochlea anatomy when they are implanted using the kinematic technique. This could cause patellar complications, either anterior knee pain, instability or accelerated wear or loosening. The aim of our study is therefore to explore the extent to which native trochlear geometry is restored when the
Introduction. John Insall described medial release to balance the varus knee; the release he described included releasing the superficial MCL in severe varus cases. However, this release can create instability in the knee. Furthermore, this conventional wisdom does not correct the actual pathology which normally exists at the joint line, and instead it focuses on the distal end of the ligament where there is no pathology. We have established a new protocol consisting of 5 steps to balance the varus knee without releasing the superficial MCL and we tried this algorithm on a series of 115 patients with varus deformity and compared it to the outcome with a similar group that we have performed earlier using the traditional Insall technique. Material and method. 115 TKR were performed by the same surgeon using Zimmer
Background. Multiple retrospective studies have compared UC with traditional bearings and shown comparable results and outcomes when looking at clinical and radiologic variables, complications rates, and implant survivorship; however, debate still exists regarding the optimum bearing surface. The present study seeks to determine whether there are any preoperative patient demographic or medical factors or anatomic variables including femoral condylar offset and tibial slope that may predict use of a UC bearing when compared to a standard CR group. Methods. The study cohort consisted of 117 patients (41 males, 76 females) who underwent primary TKA with the senior author. The implants utilized were either the CR or UC polyethylene components of the Zimmer
Introduction. Early complication post total knee replacement reported to be higher in obese patient in general. Also the outcome of cruciate retaining and PS knee has been fully discussed before and there was no major difference in the outcomes for all the patients overall regardless of their weight. However, the purpose of this paper is to find out if the CR knee has superiority over PS knee in terms of clinical and functional outcomes and if early complication postTKR such as fracture and instability is more common in PS implant than in CR knee. This is a retrospective study comparing two groups of obese patients. The first using PS implant and the other using CR implant. These two groups were matched for age, body mass and severity of deformity. Materials & Methods. At our institution we have been using
Introduction. Early complication post total knee replacement reported to be higher in obese patient in general. Also the outcome of cruciate retaining and PS knee has been fully discussed before and there was no major difference in the outcome. However, the purpose of this paper is to find out if early complication postTKR such as fracture and instability is more common in PS implant than in CR knee. This is a retrospective study comparing two groups of obese patients. The first using PS implant and the other using CR implant. These two groups were matched for age, body mass and severity of deformity. We clearly showed that there is significant increase in peri-prosthetic fracture and instability in the group that use PS implant. Materials & Methods. At our institution we have been using
PURPOSE. Total knee arthroplasty (TKA) is a successful technique for treating painful osteoarthritic knees. However, the patients' satisfaction is not still comparable with total hip arthroplasty. Basically, the conditions with operated joints were anterior cruciate ligament (ACL) deficient knees, thus, the abnormal kinematics is one of the main reason for the patients' incomplete satisfaction. Bi-cruciate stabilized (BCS) TKA was established to reproduce both ACL and posterior cruciate ligament (PCL) function and expected to improve the abnormal kinematics. However, there were few reports to evaluate intraoperative kinematics in BCS TKA using navigation system. Hence, the aim in this study is to reveal the intraoperative kinematics in BCS TKA and compare the kinematics with conventional posterior stabilized (PS) TKA. Materials and Methods. Twenty five consecutive subjects (24 women, 1 men; average age, 77 years; age range, 58–85 years) with varus osteoarthritis undergoing navigated BCS TKA (Journey II, Smith&Nephew) were enrolled in this study. An image-free navigation system (Stryker 4.0 image-free computer navigation system; Stryker) was used for the operation. Registration was performed after minimum medial soft tissue release, ACL and PCL resection, and osteophyte removal. Then, kinematics including tibiofemoral rotational angles from maximum extension to maximum flexion were recorded. The measurements were performed again after implantation. We compared the kinematics with the kinematics of paired matched fifty subjects who underwent conventional posterior stabilized (PS) TKA (25 subjects with Triathlon, Stryker; 25 subjects with
Purpose. Analysis of the morphology of the distal femur, and by extension of the femoral components in total knee arthroplasty (TKA), has been related to the aspect ratio, which represents the width of the femur. Little is known about variations in trapezoidicity (i.e whether the femur is more rectangular or more trapezoidal). This study aimed to quantify additional morphological characteristics of the distal femur and identify anatomical features associated with higher risks of over- or under-sizing of components in TKA. Method. We analyzed the shape of 114 arthritic knees at the time of primary TKA using the pre-operative CT scans. The maximum AP dimension was measured. The mediolateral dimensions were measured on the theoretical distal resection slice at three levels: the posterior region (MLP), the central region (MLC) and the anterior region (MLA) (Fig 1). The ‘aspect’ ratio (MLC/AP) ratio quantified how wide or narrow the shape is. The ‘trapezoidicity’ ratio (MLP/MLA) ratio quantified how rectangular or trapezoidal the shape is. We also quantified the medial and lateral ‘narrowing angles’ in the anterior and central zones (α and β) (Fig 2). The post-operative prosthetic overhang was calculated from CT-scan. We compared the morphological characteristics with those of twelve TKA models scanned using a three-dimensional optical scanning machine (ATOS II, GOM mbH, Braunschweig, Germany) and its photogrammetric analysis software (TRITOP, GOM mbH, Braunschweig, Germany). Results. There were significant variations in both the aspect ratio (1.16±0.07; range 0.98–1.31) and the trapezoidicity ratio (1.21±0.08; range 1.06– 1.46). Femoral trapezoidicity was mostly due to an inward curve of the medial cortex. The multivariate analysis indicated that prosthetic overhang was correlated to the ‘aspect ratio’ (more overhang in narrow femurs, p=0.002), to the ‘trapezoidicity ratio’ (more overhang in trapezoidal femurs, p=0.002), and to the Tibio Femoral Angle (more overhang in valgus knees, p=0.035). The geometries of the twelve specimen components can be compared directly with the morphological findings of this study. Some components had excessively low trapezoidicity ratios (i.e. were too rectangular) such as DePuy LCS and Stryker Scorpio. Other designs had trapezoidicity ratios closer to anatomic values such as Zimmer Nexgen, Zimmer
Introduction. Previous studies of long-term CoCr alloy femoral components for TKA have identified 3rd body abrasive wear and inflammatory cell induced corrosion (ICIC). The extent of femoral condyle surface damage in contemporary CoCr femoral components is currently unclear. The purpose of this study was to investigate the prevalence and morphology of damage (3rd body scratches and ICIC) at the bearing surface in retrieved TKA femoral components from contemporary designs. Methods. 308 CoCr femoral TKA components were collected as part of an ongoing, multi-institutional orthopedic implant retrieval program. The collection included contemporary designs from Stryker (Triathlon n=48, NRG n=10, Scorpio n=31), Depuy Synthes (PFC n=27) and Zimmer (NexGen n=140,