The Olympia femoral stem is a stainless steel, anatomically shaped, polished and three-dimensionally tapered implant designed for use in cemented total hip arthroplasty (THA). The primary aim of this study was to determine the long-term survivorship, radiographic outcome, and patient reported outcome measures (PROMs) of the Olympia stem. Between May 2003 and December 2005, 239 patients (264 THAs) underwent a THA with an Olympia stem in our institution. PROMs were assessed using the Oxford Hip Score (OHS), EuroQol-5 dimensions (EQ-5D) score and patient satisfaction at mean 10-years following THA. Patient records and radiographs were then reviewed at a mean of 16.5 years (SD 0.7, 15.3 to 17.8) following THA to identify occurrence of complications or revision surgery for any cause. Mean patient age at surgery was 68.0 years (SD 10.9, 31–93 years). There were 156 women (65%, 176 THAs). Osteoarthritis was the indication for THA in 204 patients (85%). Stem survivorship at 10 years was 99.2% (95 % confidence interval [CI], 97.9%-100%) and at 15 years was 97.5% (94.6%–100%). The 15-year stem survival for aseptic loosening was 100%. Only one occurrence of
Conventional methods of treating ankle fractures
in the elderly are associated with high rates of complication. We describe
the results of treating these injuries in 48 frail elderly patients
with a long calcaneotalotibial nail. The mean age of the group was 82 years (61 to 96) and 41 (85%)
were women. All were frail, with multiple medical comorbidities
and their mean American Society of Anaesthesiologists score was
3 (3 to 4). None could walk independently before their operation.
All the fractures were displaced and unstable; the majority (94%,
45 of 48) were low-energy injuries and 40% (19 of 48) were open. . The overall mortality at six months was 35%. Of the surviving
patients, 90% returned to their pre-injury level of function. The
mean pre- and post-operative Olerud and Molander questionnaire scores
were 62 and 57 respectively. Complications included superficial
infection (4%, two of 48); deep infection (2%, one of 48); a broken
or loose distal locking screw (6%, three of 48); valgus malunion
(4%, two of 48); and one below-knee amputation following an unsuccessful
vascular operation. There were no cases of nonunion, nail breakage
or
Using data from the Norwegian Hip Fracture Register,
8639 cemented and 2477 uncemented primary hemiarthroplasties for
displaced fractures of the femoral neck in patients aged > 70 years
were included in a prospective observational study. A total of 218
re-operations were performed after cemented and 128 after uncemented
procedures. Survival of the hemiarthroplasties was calculated using
the Kaplan-Meier method and hazard rate ratios (HRR) for revision
were calculated using Cox regression analyses. At five years the
implant survival was 97% (95% confidence interval (CI) 97 to 97)
for cemented and 91% (95% CI 87 to 94) for uncemented hemiarthroplasties.
Uncemented hemiarthroplasties had a 2.1 times increased risk of
revision compared with cemented prostheses (95% confidence interval
1.7 to 2.6, p < 0.001). The increased risk was mainly caused
by revisions for
The purpose of this study was to identify changing
trends in the pattern of distribution of the type and demographics
of fractures of the hip in the elderly between 2001 and 2010. A
retrospective cross-sectional comparison was conducted between 179
fractures of the hip treated in 2001, 357 treated in 2006 and 454
treated in 2010. Patients aged <
60 years and those with pathological
and
Over the last few decades, the All-Poly Monoblock Tibia has been relegated to a minimum use in the major healthcare systems of the western world. The main reason for this has been the perception that this tibial component is inferior in its ability to withstand stresses. This perception originated and subsequently gained ground, due to certain historical reasons, leading to the widespread use of the modular metal-backed tibial component despite a higher cost. The recent economic downturn has enforced even the rich western healthcare systems to look for cost-effective solutions. The author works in India, where the society is still highly price-sensitive and takes value for money very seriously. Further, the routine ADL of the Indian population requires them to adopt high flexion postures such as cross-legged sitting and squatting. The author has used the All-Poly Tibia extensively, which is the most economical of tibial components. Further, he has developed a surgical technique which has resulted in his patients achieving high flexion (greater than 135 degrees) in more than 75% cases. This paper presents the 10 year results of a series of 500 cases of Primary TKR in which the All-Poly Monoblock Tibia had been used. All the patients had cross-legged sitting activity as part of their ADL, thus presumably generating significant pressures on the joint surfaces. Of the original 500 cases, we could follow up 434 cases. We report a 96% survival rate of the implant in this series. There was not a single aseptic plastic failure. The revisions required were due to infection,
Introduction. The legion knee revision system was designed as a follow and improvement to the Genesis II knee system- allowing for a surgeon directed femoral rotation as opposed to the in-built femoral rotation in the previous system. This is a prospective review of consecutive patients who underwent knee revision surgery using the legion knee system. Methods. Clinical and functional assessments were carried out preoperatively, one year and 2 years post op. Radiographic evaluation was done at 1 and 2years follow up. Standard knee scoring systems (American Knee Scores-AKS, and Oxford score were used for the clinical and functional evaluation of these patients. The WOMAC score was also used to assess for pain, stiffness and social function in these patients. The radiographic assessment included review of standing AP, lateral and skyline views. Figgie's method was used to measure the joint line reproduction. A difference of 5 mm (pre = op/post-op) was deemed satisfactory. Results. Seventy-five consecutive patients underwent revision knee system- 38 male: 34 females with a mean age of 71.2 (50–87 yrs.). Mean BMI-26.03, (Range 11–50). We had a 2-year follow up for 32 patients Surgery was carried out at a single centre and performed by members of the Bristol knee group. Indications for surgery in these patients- were aseptic loosening (38), instability (15), pain and stiffness (7), polyarthropathy (2), ligament laxity (3),
Introduction. treatment of femoral neck fractures in the physically active elderly, is still an open question. The comparison of total replacement and partial hip replacement showed substantial superiority of the first approach than the latter. We can not disregard the problems that THR can lead in the elderly: more surgical time, greater blood loss, major sacrifice of bone in osteoporotic subjects. The Tribofit® acetabular system, has the objective to overcome these problems with the implantation of a single 3mm soft, pliable buffer made of polycarbonate-urethane between the large diameter metal femoral head and the subchondral bone, thus replacing the articular cartilage. The surgical technique includes the reaming of the cartilage layer, the creation of a circumferential groove and the snap-fit insertion of the buffer. The purpose of the prospective study was to evaluate the effectiveness of this approach in the treatment of femoral neck fractures in the elderly. Materials and Methods. from September 2008 to July 2010 we performed 45 implants with the Tribofit® Acetabular Buffer (Active Implants®, Memphis TN, USA). The inclusion criteria for the study were: femoral neck fracture patients over 75 years of age, physically independent before the injury, with good life expectancy, mild or absent arthritis, absence of morphological alterations of the acetabulum. The average age of these patients was 81,2 (75–89), the sex distribution was 36 females and 9 males, with 22 fractures of the left hip and 23 of the right. In all cases an uncemented straight femoral stem was implanted. We recorded per-operative blood loss and intra-per-operative problems encountered. Follow-up were performed at 1, 3, 6 and 12 months post-op with radiographic control and clinical examination. The clinical outcome was objectively measured by the Harris Hip Score, pain Visual Analogue Scale and SF-36 questionnaire. Results. Of the 45 patients, 4 died of unrelated causes and 3 were lost to follow-up (2 due to cognitive impairment and 1 due to
Background. Extendable proximal femoral replacements(PFR) are used in children with bone tumours in proximity to the proximal femoral physis, previously treated by hip disarticulation. Long-axis growth is preserved, allowing limb salvage. Since 1986, survival outcomes after limb salvage and amputation have been known to be equal. Method. Retrospective review of all patients <16years undergoing extendable PFR at Royal National Orthopaedic Hospital (UK) between 04/1996 and 01/2006, recording complications, failures, procedures undertaken and patient outcomes. Results. 8 patients (mean age 8.9±3 years) underwent extendable PFR for Ewing's Sarcoma(5), Osteosarcoma(1), Chondrosarcoma(1) and rhabdomyosarcoma(1). 2 primary PFRs failed (infection of unknown source & local recurrence, both at 26months); 2 required revision for full extension (1 became infected at revision, requiring 2 stage revision). 3 patients had the original prosthesis in situ at last follow-up (mean 7.2;range 3–10.5years). 1 patient had no implant complications, but died (neutropaenic sepsis) 63 days after implant insertion. 2 were treated for recurrence but disease free at last review. 5 were continuously disease free. 5 patients were lengthened a mean 3.7cm; 2 were not lengthened.1 had incomplete data. 5 patients suffered subluxation/dislocation (mean 15.6months), 3 recurrently. Each underwent a mean 1.6 open & 1.4 closed procedures for the displaced joint. 3 patients had 4 open reductions and acetabuloplasties and 2 patients were converted to THR, with 3 major complications: 2 sciatic nerve palsies and 1 (THR) infection. The 5th patient was due for acetabuloplasty but had hip disarticulation for recurrence. Acetabular erosion occurred in 3; 2 were revised to THR (3.5 & 6.8years). 3 patients suffered
National Institute of Clinical Excellence guidelines
state that cemented stems with an Orthopaedic Data Evaluation Panel
(ODEP) rating of >
3B should be used for hemiarthroplasty when treating
an intracapsular fracture of the femoral neck. These recommendations
are based on studies in which most, if not all stems, did not hold
such a rating. This case-control study compared the outcome of hemiarthroplasty
using a cemented (Exeter) or uncemented (Corail) femoral stem. These
are the two prostheses most commonly used in hip arthroplasty in
the UK. Data were obtained from two centres; most patients had undergone
hemiarthroplasty using a cemented Exeter stem (n = 292/412). Patients
were matched for all factors that have been shown to influence mortality
after an intracapsular fracture of the neck of the femur. Outcome
measures included: complications, re-operations and mortality rates
at two, seven, 30 and 365 days post-operatively. Comparable outcomes
for the two stems were seen. There were more intra-operative complications in the uncemented
group (13% This study therefore supports the use of both cemented and uncemented
stems of proven design, with an ODEP rating of 10A, in patients
with an intracapsular fracture of the neck of the femur. Cite this article:
Our aim in this pilot study was to evaluate the fixation of, the bone remodelling around, and the clinical outcome after surgery of a new, uncemented, fully hydroxyapatite-coated, collared and tapered femoral component, designed specifically for elderly patients with a fracture of the femoral neck. We enrolled 50 patients, of at least 70 years of age, with an acute displaced fracture of the femoral neck in this prospective single-series study. They received a total hip replacement using the new component and were followed up regularly for two years. Fixation was evaluated by radiostereometric analysis and bone remodelling by dual-energy x-ray absorptiometry. Hip function and the health-related quality of life were assessed using the Harris hip score and the EuroQol-5D. Up to six weeks post-operatively there was a mean subsidence of 0.2 mm (−2.1 to +0.5) and a retroversion of a mean of 1.2° (−8.2° to +1.5°). No component migrated after three months. The patients had a continuous loss of peri-prosthetic bone which amounted to a mean of 16% (−49% to +10%) at two years. The mean Harris hip score was 82 (51 to 100) after two years. The two-year results from this pilot study indicate that this new, uncemented femoral component can be used for elderly patients with osteoporotic fractures of the femoral neck.
Although the use of constrained cemented arthroplasty to treat distal femoral fractures in elderly patients has some practical advantages over the use of techniques of fixation, concerns as to a high rate of loosening after implantation of these prostheses has raised doubts about their use. We evaluated the results of hinged total knee replacement in the treatment of 54 fractures in 52 patients with a mean age of 82 years (55 to 98), who were socially dependent and poorly mobile. Within the first year after implantation 22 of the 54 patients had died, six had undergone a further operation and two required a revision of the prosthesis. The subsequent rate of further surgery and revision was low. A constrained knee prosthesis offers a useful alternative treatment to internal fixation in selected elderly patients with these fractures, and has a high probability of surviving as long as the patient into whom it has been implanted.
We studied the epidemiology of 401 fractures of the shaft of the humerus in 397 patients aged 16 years or older. The incidence was 14.5 per 100 000 per year with a gradually increasing age-specific incidence from the fifth decade, reaching almost 60 per 100 000 per year in the ninth decade. Most were closed fractures in elderly patients which had been sustained as the result of a simple fall. The age distribution in women was characterised by a peak in the eighth decade while that in men was more even. Simple fractures were by far the most common and most were located in the middle or proximal shaft. The incidence of palsy of the radial nerve was 8% and fractures in the middle and distal shaft were most likely to be responsible. Only 2% of the fractures were open and 8% were pathological. These figures are representative of a population with a low incidence of high-energy and penetrating trauma, which probably reflects the situation in most European countries.
United Kingdom National Institute for Health
and Clinical Excellence guidelines recommend the use of total hip replacement
(THR) for displaced intracapsular fractures of the femoral neck
in cognitively intact patients, who were independently mobile prior
to the injury. This study aimed to analyse the risk factors associated
with revision of the implant and mortality following THR, and to
quantify risk. National Joint Registry data recording a THR performed
for acute fracture of the femoral neck between 2003 and 2010 were
analysed. Cox proportional hazards models were used to investigate
the extent to which risk of revision was related to specific covariates.
Multivariable logistic regression was used to analyse factors affecting
peri-operative mortality (<
90 days). A total of 4323 procedures
were studied. There were 80 patients who had undergone revision
surgery at the time of censoring (five-year revision rate 3.25%, 95%
confidence interval 2.44 to 4.07) and 137 patients (3.2%) patients
died within 90 days. After adjusting for patient and surgeon characteristics,
an increased risk of revision was associated with the use of cementless
prostheses compared with cemented (hazard ratio (HR) 1.33, p = 0.021).
Revision was independent of bearing surface and head size. The risk
of mortality within 90 days was significantly increased with higher
American Society of Anesthesiologists (ASA) grade (grade 3: odds
ratio (OR) 4.04, p <
0.001; grade 4/5: OR 20.26, p <
0.001;
both compared with grades 1/2) and older age (≥ 75 years: OR 1.65,
p = 0.025), but reduced over the study period (9% relative risk reduction
per year). THR is a good option in patients aged <
75 years and with
ASA 1/2. Cementation of the femoral component does not adversely
affect peri-operative mortality but improves survival of the implant
in the mid-term when compared with cementless femoral components.
There are no benefits of using head sizes >
28 mm or bearings other
than metal-on-polyethylene. More research is required to determine
the benefits of THR over hemiarthroplasty in older patients and
those with ASA grades >
2.
We performed a retrospective study of a departmental database to assess the efficacy of a new model of orthopaedic care on the outcome of patients with a fracture of the proximal femur. All 1578 patients admitted to a university teaching hospital with a fracture of the proximal femur between December 2007 and December 2009 were included. The allocation of Foundation doctors years 1 and 2 was restructured from individual teams covering several wards to pairs covering individual wards. No alterations were made in the numbers of doctors, their hours, out-of-hours cover, or any other aspect of standard patient care. Outcome measures comprised 30-day mortality and cause, complications and length of stay. Mortality was reduced from 11.7% to 7.6% (p = 0.007, Cox’s regression analysis); adjusted odds ratio was 1.559 (95% confidence interval 1.128 to 2.156). Reductions were seen in These findings may have implications for all specialties caring for patients on several wards, and we believe they justify a prospective trial to further assess this effect.
We evaluated the cost and consequences of proximal femoral fractures requiring further surgery because of complications. The data were collected prospectively in a standard manner from all patients with a proximal femoral fracture presenting to the trauma unit at the John Radcliffe Hospital over a five-year period. The total cost of treatment for each patient was calculated by separating it into its various components. The risk factors for the complications that arose, the location of their discharge and the mortality rates for these patients were compared to those of a matched control group. There were 2360 proximal femoral fractures in 2257 patients, of which 144 (6.1%) required further surgery. The mean cost of treatment in patients with complications was £18 709 (£2606.30 to £60.827.10), compared with £8610 (£918.54 to £45 601.30) for uncomplicated cases (p <
0.01), with a mean length of stay of 62.8 (44.5 to 79.3) and 32.7 (23.8 to 35.0) days, respectively. The probability of mortality after one month in these cases was significantly higher than in the control group, with a mean survival of 209 days, compared with 496 days for the controls. Patients with complications were statistically less likely to return to their own home (p <
0.01). Greater awareness and understanding are required to minimise the complications of proximal femoral fractures and consequently their cost.
Prospective data on hip fracture from 3686 patients at a United Kingdom teaching hospital were analysed to investigate the risk factors, financial costs and outcomes associated with deep or superficial wound infections after hip fracture surgery. In 1.2% (41) of patients a deep wound infection developed, and 1.1% (39) had a superficial wound infection. A total of 57 of 80 infections (71.3%) were due to No statistically significant pre-operative risk factors were detected. Length of stay, cost of treatment and pre-discharge mortality all significantly increased with deep wound infection. The one-year mortality was 30%, and this increased to 50% in those who developed an infection (p <
0.001). A deep infection resulted in doubled operative costs, tripled investigation costs and quadrupled ward costs. MRSA infection increased costs, length of stay, and pre-discharge mortality compared with non-MRSA infection.