The Olympia femoral stem is a stainless steel, anatomically shaped, polished and three-dimensionally tapered implant designed for use in cemented total hip arthroplasty (THA). The primary aim of this study was to determine the long-term survivorship, radiographic outcome, and patient reported outcome measures (PROMs) of the Olympia stem. Between May 2003 and December 2005, 239 patients (264 THAs) underwent a THA with an Olympia stem in our institution. PROMs were assessed using the Oxford Hip Score (OHS), EuroQol-5 dimensions (EQ-5D) score and patient satisfaction at mean 10-years following THA. Patient records and radiographs were then reviewed at a mean of 16.5 years (SD 0.7, 15.3 to 17.8) following THA to identify occurrence of complications or revision surgery for any cause. Mean patient age at surgery was 68.0 years (SD 10.9, 31–93 years). There were 156 women (65%, 176 THAs). Osteoarthritis was the indication for THA in 204 patients (85%). Stem survivorship at 10 years was 99.2% (95 % confidence interval [CI], 97.9%-100%) and at 15 years was 97.5% (94.6%–100%). The 15-year stem survival for aseptic loosening was 100%. Only one occurrence of
Conventional methods of treating ankle fractures
in the elderly are associated with high rates of complication. We describe
the results of treating these injuries in 48 frail elderly patients
with a long calcaneotalotibial nail. The mean age of the group was 82 years (61 to 96) and 41 (85%)
were women. All were frail, with multiple medical comorbidities
and their mean American Society of Anaesthesiologists score was
3 (3 to 4). None could walk independently before their operation.
All the fractures were displaced and unstable; the majority (94%,
45 of 48) were low-energy injuries and 40% (19 of 48) were open. . The overall mortality at six months was 35%. Of the surviving
patients, 90% returned to their pre-injury level of function. The
mean pre- and post-operative Olerud and Molander questionnaire scores
were 62 and 57 respectively. Complications included superficial
infection (4%, two of 48); deep infection (2%, one of 48); a broken
or loose distal locking screw (6%, three of 48); valgus malunion
(4%, two of 48); and one below-knee amputation following an unsuccessful
vascular operation. There were no cases of nonunion, nail breakage
or
Our aim in this pilot study was to evaluate the fixation of, the bone remodelling around, and the clinical outcome after surgery of a new, uncemented, fully hydroxyapatite-coated, collared and tapered femoral component, designed specifically for elderly patients with a fracture of the femoral neck. We enrolled 50 patients, of at least 70 years of age, with an acute displaced fracture of the femoral neck in this prospective single-series study. They received a total hip replacement using the new component and were followed up regularly for two years. Fixation was evaluated by radiostereometric analysis and bone remodelling by dual-energy x-ray absorptiometry. Hip function and the health-related quality of life were assessed using the Harris hip score and the EuroQol-5D. Up to six weeks post-operatively there was a mean subsidence of 0.2 mm (−2.1 to +0.5) and a retroversion of a mean of 1.2° (−8.2° to +1.5°). No component migrated after three months. The patients had a continuous loss of
Using data from the Norwegian Hip Fracture Register,
8639 cemented and 2477 uncemented primary hemiarthroplasties for
displaced fractures of the femoral neck in patients aged > 70 years
were included in a prospective observational study. A total of 218
re-operations were performed after cemented and 128 after uncemented
procedures. Survival of the hemiarthroplasties was calculated using
the Kaplan-Meier method and hazard rate ratios (HRR) for revision
were calculated using Cox regression analyses. At five years the
implant survival was 97% (95% confidence interval (CI) 97 to 97)
for cemented and 91% (95% CI 87 to 94) for uncemented hemiarthroplasties.
Uncemented hemiarthroplasties had a 2.1 times increased risk of
revision compared with cemented prostheses (95% confidence interval
1.7 to 2.6, p < 0.001). The increased risk was mainly caused
by revisions for
The purpose of this study was to identify changing
trends in the pattern of distribution of the type and demographics
of fractures of the hip in the elderly between 2001 and 2010. A
retrospective cross-sectional comparison was conducted between 179
fractures of the hip treated in 2001, 357 treated in 2006 and 454
treated in 2010. Patients aged <
60 years and those with pathological
and
Over the last few decades, the All-Poly Monoblock Tibia has been relegated to a minimum use in the major healthcare systems of the western world. The main reason for this has been the perception that this tibial component is inferior in its ability to withstand stresses. This perception originated and subsequently gained ground, due to certain historical reasons, leading to the widespread use of the modular metal-backed tibial component despite a higher cost. The recent economic downturn has enforced even the rich western healthcare systems to look for cost-effective solutions. The author works in India, where the society is still highly price-sensitive and takes value for money very seriously. Further, the routine ADL of the Indian population requires them to adopt high flexion postures such as cross-legged sitting and squatting. The author has used the All-Poly Tibia extensively, which is the most economical of tibial components. Further, he has developed a surgical technique which has resulted in his patients achieving high flexion (greater than 135 degrees) in more than 75% cases. This paper presents the 10 year results of a series of 500 cases of Primary TKR in which the All-Poly Monoblock Tibia had been used. All the patients had cross-legged sitting activity as part of their ADL, thus presumably generating significant pressures on the joint surfaces. Of the original 500 cases, we could follow up 434 cases. We report a 96% survival rate of the implant in this series. There was not a single aseptic plastic failure. The revisions required were due to infection,
We used an inverted shoulder arthroplasty in 43 consecutive patients with a mean age of 78 years (65 to 97) who had sustained a three- or four-part fracture of the upper humerus. All except two were reviewed with a mean follow-up of 22 months (6 to 58). The clinical outcome was satisfactory with a mean active anterior elevation of 97° (35° to 160°) and a mean active external rotation in abduction of 30° (0° to 80°). The mean Constant and the mean modified Constant scores were respectively 44 (16 to 69) and 66% (25% to 97%). Complications included three patients with reflex sympathetic dystrophy, five with neurological complications, most of which resolved, and one with an anterior dislocation. Radiography showed
Introduction. The legion knee revision system was designed as a follow and improvement to the Genesis II knee system- allowing for a surgeon directed femoral rotation as opposed to the in-built femoral rotation in the previous system. This is a prospective review of consecutive patients who underwent knee revision surgery using the legion knee system. Methods. Clinical and functional assessments were carried out preoperatively, one year and 2 years post op. Radiographic evaluation was done at 1 and 2years follow up. Standard knee scoring systems (American Knee Scores-AKS, and Oxford score were used for the clinical and functional evaluation of these patients. The WOMAC score was also used to assess for pain, stiffness and social function in these patients. The radiographic assessment included review of standing AP, lateral and skyline views. Figgie's method was used to measure the joint line reproduction. A difference of 5 mm (pre = op/post-op) was deemed satisfactory. Results. Seventy-five consecutive patients underwent revision knee system- 38 male: 34 females with a mean age of 71.2 (50–87 yrs.). Mean BMI-26.03, (Range 11–50). We had a 2-year follow up for 32 patients Surgery was carried out at a single centre and performed by members of the Bristol knee group. Indications for surgery in these patients- were aseptic loosening (38), instability (15), pain and stiffness (7), polyarthropathy (2), ligament laxity (3),
Introduction. treatment of femoral neck fractures in the physically active elderly, is still an open question. The comparison of total replacement and partial hip replacement showed substantial superiority of the first approach than the latter. We can not disregard the problems that THR can lead in the elderly: more surgical time, greater blood loss, major sacrifice of bone in osteoporotic subjects. The Tribofit® acetabular system, has the objective to overcome these problems with the implantation of a single 3mm soft, pliable buffer made of polycarbonate-urethane between the large diameter metal femoral head and the subchondral bone, thus replacing the articular cartilage. The surgical technique includes the reaming of the cartilage layer, the creation of a circumferential groove and the snap-fit insertion of the buffer. The purpose of the prospective study was to evaluate the effectiveness of this approach in the treatment of femoral neck fractures in the elderly. Materials and Methods. from September 2008 to July 2010 we performed 45 implants with the Tribofit® Acetabular Buffer (Active Implants®, Memphis TN, USA). The inclusion criteria for the study were: femoral neck fracture patients over 75 years of age, physically independent before the injury, with good life expectancy, mild or absent arthritis, absence of morphological alterations of the acetabulum. The average age of these patients was 81,2 (75–89), the sex distribution was 36 females and 9 males, with 22 fractures of the left hip and 23 of the right. In all cases an uncemented straight femoral stem was implanted. We recorded per-operative blood loss and intra-per-operative problems encountered. Follow-up were performed at 1, 3, 6 and 12 months post-op with radiographic control and clinical examination. The clinical outcome was objectively measured by the Harris Hip Score, pain Visual Analogue Scale and SF-36 questionnaire. Results. Of the 45 patients, 4 died of unrelated causes and 3 were lost to follow-up (2 due to cognitive impairment and 1 due to
INTRODUCTION. The advantages of large diameter metal on metal total hip arthroplasty (MoM THA) and hip resurfacing arthroplasty are decreased wear rate, preservation of bone stock, anatomical restoration and enhanced stability. Large amounts of metal wear particles and metal ions are released which may induce adverse reactions including local soft tissue toxicity, hypersensitivity reactions, bone loss and risk of carcinogenesis. Aseptic loosening can be the result of a
Background. Extendable proximal femoral replacements(PFR) are used in children with bone tumours in proximity to the proximal femoral physis, previously treated by hip disarticulation. Long-axis growth is preserved, allowing limb salvage. Since 1986, survival outcomes after limb salvage and amputation have been known to be equal. Method. Retrospective review of all patients <16years undergoing extendable PFR at Royal National Orthopaedic Hospital (UK) between 04/1996 and 01/2006, recording complications, failures, procedures undertaken and patient outcomes. Results. 8 patients (mean age 8.9±3 years) underwent extendable PFR for Ewing's Sarcoma(5), Osteosarcoma(1), Chondrosarcoma(1) and rhabdomyosarcoma(1). 2 primary PFRs failed (infection of unknown source & local recurrence, both at 26months); 2 required revision for full extension (1 became infected at revision, requiring 2 stage revision). 3 patients had the original prosthesis in situ at last follow-up (mean 7.2;range 3–10.5years). 1 patient had no implant complications, but died (neutropaenic sepsis) 63 days after implant insertion. 2 were treated for recurrence but disease free at last review. 5 were continuously disease free. 5 patients were lengthened a mean 3.7cm; 2 were not lengthened.1 had incomplete data. 5 patients suffered subluxation/dislocation (mean 15.6months), 3 recurrently. Each underwent a mean 1.6 open & 1.4 closed procedures for the displaced joint. 3 patients had 4 open reductions and acetabuloplasties and 2 patients were converted to THR, with 3 major complications: 2 sciatic nerve palsies and 1 (THR) infection. The 5th patient was due for acetabuloplasty but had hip disarticulation for recurrence. Acetabular erosion occurred in 3; 2 were revised to THR (3.5 & 6.8years). 3 patients suffered
National Institute of Clinical Excellence guidelines
state that cemented stems with an Orthopaedic Data Evaluation Panel
(ODEP) rating of >
3B should be used for hemiarthroplasty when treating
an intracapsular fracture of the femoral neck. These recommendations
are based on studies in which most, if not all stems, did not hold
such a rating. This case-control study compared the outcome of hemiarthroplasty
using a cemented (Exeter) or uncemented (Corail) femoral stem. These
are the two prostheses most commonly used in hip arthroplasty in
the UK. Data were obtained from two centres; most patients had undergone
hemiarthroplasty using a cemented Exeter stem (n = 292/412). Patients
were matched for all factors that have been shown to influence mortality
after an intracapsular fracture of the neck of the femur. Outcome
measures included: complications, re-operations and mortality rates
at two, seven, 30 and 365 days post-operatively. Comparable outcomes
for the two stems were seen. There were more intra-operative complications in the uncemented
group (13% This study therefore supports the use of both cemented and uncemented
stems of proven design, with an ODEP rating of 10A, in patients
with an intracapsular fracture of the neck of the femur. Cite this article:
Although the use of constrained cemented arthroplasty to treat distal femoral fractures in elderly patients has some practical advantages over the use of techniques of fixation, concerns as to a high rate of loosening after implantation of these prostheses has raised doubts about their use. We evaluated the results of hinged total knee replacement in the treatment of 54 fractures in 52 patients with a mean age of 82 years (55 to 98), who were socially dependent and poorly mobile. Within the first year after implantation 22 of the 54 patients had died, six had undergone a further operation and two required a revision of the prosthesis. The subsequent rate of further surgery and revision was low. A constrained knee prosthesis offers a useful alternative treatment to internal fixation in selected elderly patients with these fractures, and has a high probability of surviving as long as the patient into whom it has been implanted.
Radiological evidence of post-traumatic osteoarthritis
(PTOA) after fracture of the tibial plateau is common but end-stage arthritis
which requires total knee arthroplasty is much rarer. The aim of this study was to examine the indications for, and
outcomes of, total knee arthroplasty after fracture of the tibial
plateau and to compare this with an age and gender-matched cohort
of TKAs carried out for primary osteoarthritis. Between 1997 and 2011, 31 consecutive patients (23 women, eight
men) with a mean age of 65 years (40 to 89) underwent TKA at a mean
of 24 months (2 to 124) after a fracture of the tibial plateau.
Of these, 24 had undergone ORIF and seven had been treated non-operatively.
Patients were assessed pre-operatively and at 6, 12 and >
60 months
using the Short Form-12, Oxford Knee Score and a patient satisfaction
score. Patients with instability or nonunion needed total knee arthroplasty
earlier (14 and 13.3 months post-injury) than those with intra-articular
malunion (50 months, p <
0.001). Primary cruciate-retaining implants
were used in 27 (87%) patients. Complication rates were higher in
the PTOA cohort and included wound complications (13% Total knee arthroplasty undertaken after fracture of the tibial
plateau has a higher rate of complications than that undertaken
for primary osteoarthritis, but patient-reported outcomes and satisfaction
are comparable. Cite this article:
It is becoming increasingly common for a patient
to have ipsilateral hip and knee replacements. The inter-prosthetic (IP)
distance, the distance between the tips of hip and knee prostheses,
has been thought to be associated with an increased risk of IP fracture.
Small gap distances are generally assumed to act as stress risers,
although there is no real biomechanical evidence to support this. The purpose of this study was to evaluate the influence of IP
distance, cortical thickness and bone mineral density on the likelihood
of an IP femoral fracture. A total of 18 human femur specimens were randomised into three
groups by bone density and cortical thickness. For each group, a
defined IP distance of 35 mm, 80 mm or 160 mm was created by choosing
the appropriate lengths of component. The maximum fracture strength
was determined using a four-point bending test. The fracture force of all three groups was similar (p = 0.498).
There was a highly significant correlation between the cortical
area and the fracture strength (r = 0.804, p <
0.001), whereas
bone density showed no influence. This study suggests that the IP distance has little influence
on fracture strength in IP femoral fractures: the thickness of the
cortex seems to be the decisive factor. Cite this article:
Patients with transfemoral amputation (TFA) often
experience problems related to the use of socket-suspended prostheses.
The clinical development of osseointegrated percutaneous prostheses
for patients with a TFA started in 1990, based on the long-term
successful results of osseointegrated dental implants. Between1999 and 2007, 51 patients with 55 TFAs were consecutively
enrolled in a prospective, single-centre non-randomised study and
followed for two years. The indication for amputation was trauma
in 33 patients (65%) and tumour in 12 (24%). A two-stage surgical
procedure was used to introduce a percutaneous implant to which
an external amputation prosthesis was attached. The assessment of
outcome included the use of two self-report questionnaires, the
Questionnaire for Persons with a Transfemoral Amputation (Q-TFA)
and the Short-Form (SF)-36. The cumulative survival at two years’ follow-up was 92%. The
Q-TFA showed improved prosthetic use, mobility, global situation
and fewer problems (all p <
0.001). The physical function SF-36
scores were also improved (p <
0.001). Superficial infection
was the most frequent complication, occurring 41 times in 28 patients
(rate of infection 54.9%). Most were treated effectively with oral
antibiotics. The implant was removed in four patients because of loosening
(three aseptic, one infection). Osseointegrated percutaneous implants constitute a novel form
of treatment for patients with TFA. The high cumulative survival
rate at two years (92%) combined with enhanced prosthetic use and
mobility, fewer problems and improved quality of life, supports
the ‘revolutionary change’ that patients with TFA have reported
following treatment with osseointegrated percutaneous prostheses. Cite this article:
We studied the epidemiology of 401 fractures of the shaft of the humerus in 397 patients aged 16 years or older. The incidence was 14.5 per 100 000 per year with a gradually increasing age-specific incidence from the fifth decade, reaching almost 60 per 100 000 per year in the ninth decade. Most were closed fractures in elderly patients which had been sustained as the result of a simple fall. The age distribution in women was characterised by a peak in the eighth decade while that in men was more even. Simple fractures were by far the most common and most were located in the middle or proximal shaft. The incidence of palsy of the radial nerve was 8% and fractures in the middle and distal shaft were most likely to be responsible. Only 2% of the fractures were open and 8% were pathological. These figures are representative of a population with a low incidence of high-energy and penetrating trauma, which probably reflects the situation in most European countries.
United Kingdom National Institute for Health
and Clinical Excellence guidelines recommend the use of total hip replacement
(THR) for displaced intracapsular fractures of the femoral neck
in cognitively intact patients, who were independently mobile prior
to the injury. This study aimed to analyse the risk factors associated
with revision of the implant and mortality following THR, and to
quantify risk. National Joint Registry data recording a THR performed
for acute fracture of the femoral neck between 2003 and 2010 were
analysed. Cox proportional hazards models were used to investigate
the extent to which risk of revision was related to specific covariates.
Multivariable logistic regression was used to analyse factors affecting
peri-operative mortality (<
90 days). A total of 4323 procedures
were studied. There were 80 patients who had undergone revision
surgery at the time of censoring (five-year revision rate 3.25%, 95%
confidence interval 2.44 to 4.07) and 137 patients (3.2%) patients
died within 90 days. After adjusting for patient and surgeon characteristics,
an increased risk of revision was associated with the use of cementless
prostheses compared with cemented (hazard ratio (HR) 1.33, p = 0.021).
Revision was independent of bearing surface and head size. The risk
of mortality within 90 days was significantly increased with higher
American Society of Anesthesiologists (ASA) grade (grade 3: odds
ratio (OR) 4.04, p <
0.001; grade 4/5: OR 20.26, p <
0.001;
both compared with grades 1/2) and older age (≥ 75 years: OR 1.65,
p = 0.025), but reduced over the study period (9% relative risk reduction
per year). THR is a good option in patients aged <
75 years and with
ASA 1/2. Cementation of the femoral component does not adversely
affect peri-operative mortality but improves survival of the implant
in the mid-term when compared with cementless femoral components.
There are no benefits of using head sizes >
28 mm or bearings other
than metal-on-polyethylene. More research is required to determine
the benefits of THR over hemiarthroplasty in older patients and
those with ASA grades >
2.
We performed a retrospective study of a departmental database to assess the efficacy of a new model of orthopaedic care on the outcome of patients with a fracture of the proximal femur. All 1578 patients admitted to a university teaching hospital with a fracture of the proximal femur between December 2007 and December 2009 were included. The allocation of Foundation doctors years 1 and 2 was restructured from individual teams covering several wards to pairs covering individual wards. No alterations were made in the numbers of doctors, their hours, out-of-hours cover, or any other aspect of standard patient care. Outcome measures comprised 30-day mortality and cause, complications and length of stay. Mortality was reduced from 11.7% to 7.6% (p = 0.007, Cox’s regression analysis); adjusted odds ratio was 1.559 (95% confidence interval 1.128 to 2.156). Reductions were seen in These findings may have implications for all specialties caring for patients on several wards, and we believe they justify a prospective trial to further assess this effect.