Advertisement for orthosearch.org.uk
Results 1 - 12 of 12
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 350 - 350
1 Sep 2012
Aksahin E Guzel A Yuksel H Celebi L Erdogan A Aktekin C Bicimoglu A
Full Access

Aim. The purpose of this study was to analyze the patellofemoral kinematics in neglected adult developmental dysplasia of the hip patients with patellofemoral symptoms and tried to clarify the affect of the severity of dislocation, the amount of limb length discrepancy, the deviation of mechanical axis and the changes in femoral anteversion on patellofemoral alignment. Methods. The dynamic patellofemoral CT results of 39 patients with DDH suffering from knee pain were reviewed. The mean age was 40.07 (range: 22–61). 14 of them were bilateral and 25 were unilateral neglected DDH patients. The CT results of 12 patients suffering from unilateral patellofemoral pain following the treatment of locked intramedullary nailing was taken as control group. In this patients atraumatic and asymptomatic normal site was taken as control group. Results. In unilateral neglected DDH patients there was significantly higher medial patellar displacement in 0, 15, 30, 60 degrees flexion in the knee at the site of dislocation. Again in uninvolved site medial patellar displacement in 15, 30, 60 degrees flexion was higher with respect to control group. In the involved extremity the PTA angle in 0, 15, 30, 60 degrees flexion were significantly higher than in control group. This increase in PTA angle corresponding to medial patellar tilt was observed only in involved extremity. In the knees of patients with bilateral DDH there was significant medial patellar displacement in every flexion degrees with respect to control group. Besides in bilateral DDH patients, the PTA angle in 15, 30, 60 degrees flexion were significantly higher than control group corresponding to medial patellar tilt. The amount of leg length discrepancy and the severity of dislocation as well as mechanical axis deviation were not affecting the patellofemoral parameters in both unilateral and bilateral DDH patients. Conclusion. Both in unilateral and bilateral DDH patients there are major changes in patellar tracking on femur during knee flexion. Increased medial shift and medial patellar tilt were seen in these patient groups. The neglected DDH patients suffering from knee pain should be analyzed not only for tibiofemoral abnormalities but also for patellofemoral malignment


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 516 - 516
1 Sep 2012
Kang S Han H Lee D
Full Access

The purpose of this study was to validate the usefulness of SPECT/CT as an evaluation method for determining treatment and prognosis for patellofemoral cartilage lesions, based on MRI and arthroscopic findings. From August 2009 to February 2010, SPECT/CT was performed on 80 patients (24 male and 56 female, average 53.3 years old) with chronic anterior knee pain who had no degenerative changes or patellar malalignment on plain radiographs. Radioisotope uptake findings on patellofemoral joint from SPECT/CT were classified into three grades by one nuclear medicine specialist. In the patients who demonstrated poor improvements after conservative treatments, MRI and arthroscopy were performed. Patellofemoral cartilage conditions under arthroscopic finding (ICRS grades) were compared with SPECT/CT grading. In all cases, there were increased uptakes on patellofemoral joints. Eighteen cases showed low uptake (Group 1), 22 cases showed medium uptake (Group 2) and 40 cases high uptake (Group 3). At the follow-up examination after mean 1.7 months, 16 cases of Group 1 (89%), 14 cases of Group 2 (64%) and 28 cases of Groups3 (70%) responded positively to the conservative treatments. For those 22 cases showing poor improvement, MRI and arthroscopy were done. Damage or thinning of patellofemoral cartilage, subchondral cyst, edema and fissuring were observed in every case that underwent MRI. Every arthroscopic case was found that there was patellofemoral cartilage damage. Each of ICRS grade I and grade II was found in 2 cases from Group 1. Two cases of grade II, 4 cases of grade III, and 2 cases of grade IV were found in Group 2. Two cases of grade II, 4 cases of grade III, and 6 cases of grade IV were found in Group 3. There was significant difference in the success rate of conservative treatment between SPECT/CT grade 1 and 2 or 3. And there was significant association between SPECT/CT grade and ICRS grade (P=0.034). SPECT/CT could be a useful modality in determining the treatment and prognosis for patellofemoral cartilage lesions compared with MRI and arthroscopic findings


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_1 | Pages 11 - 11
1 Jan 2019
Clement ND Howard TA Immelman RJ MacDonald D Patton JT Lawson G Burnett R
Full Access

The primary aim of this study was to compare the knee specific functional outcome of partial compared with total knee replacement (TKR) for the management of patellofemoral osteoarthritis. Fifty-four consecutive Avon patellofemoral replacements were identified and propensity score matched to a group of 54 patients undergoing a TKR with patella resurfacing for patellofemoral osteoarthritis. The Oxford knee score (OKS), the Short Form (SF-) 12 and patient satisfaction were collected (mean follow up 9.2 years). Survival was defined by revision or intention to revise. There was no significant difference in the OKS (p>0.60) or SF-12 (p>0.28) between the groups. The TKR group was significantly less likely to be satisfied with their knee (95.1% versus 78.3%, OR 0.18, p=0.03). Length of stay was significantly (p=0.008) shorter for the Avon group (difference 1.8 days, 95% CI 0.4 to 3.2). The 10 year survival for the Avon group was 92.3% (95% CI 87.1 to 97.5) and for the TKR group was 100% (95% CI 93.8 to 100). There was no statistical difference in the survival rate (Log Rank p=0.10). The Avon patellofemoral replacement have a shorter length of stay with a functional outcome and satisfaction rate that is equal to that of TKR. The benefits of the Avon need to be balanced against the increased rate of revision when compared with TKR


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 511 - 511
1 Sep 2012
Rienmüller A Guggi T Von Knoch F Drobny T Preiss S
Full Access

Introduction. Patellofemoral complications remain a very common post-operative problem in association with total knee arthoplasty (TKA). As malrotation of the femoral component is often considered crucial for the outcome, we analyzed absolute rotational femoral alignment in relation to patellar tracking pre- and postoperatively and matched the results with the two year functional outcome. Methods. Femoral rotation and component rotation was assessed by axial radiography using condylar twist angle (CTA). The lateral patellar displacement, patellar tilt and Insall-Salvati index were measured on conventional radiographs. All assessments were done pre-operatively and at 2-year follow up. The series included 48 consecutive TKA (21 men, 27 women) performed at a single high-volume joint-replacement-center in 2008. All operations were performed using a tibia first-ligament balancing technique without patella resurfacing. The implant used was a condylar unconstrained ultracongruent rotating platform design. Outcome was assessed using the international knee society score (KSS) and the Kujala Score for anterior knee pain. Results. Preoperative CTA showed 6.4±2. 5° (X±SD) of internal femoral rotation (IR) (range, 1° of external rotation (ER) to 12° of IR) compared to postoperative CTA of 3.9°±2.98° (X±SD) of IR (range, 9.5° IR to 3.8°of ER) Preoperative patella lateral displacement showed a mean of 1.1mm (−2mm, 6mm), compared to postoperative patella lateral displacement with a mean of 1.7mm (−3mm, 6mm). Postoperative mean patella tilt was 6.65° (1.8°, 11.7°) postoperatively compared to 8.55° (4.3°,11.5°) preoperatively. No correlation was found between CTA post surgery and patella positioning (r=0.034, 95% CI). IR of the femoral component >3°did not show increased patella lateral displacement/tilt compared to 0° or ER. No correlation was found between the Kujala score and internal rotation of the component (r=0.082, p=0.05). At 2 year post OP KSS reached > 185 of max. 200 points in over 82% of patients. Conclusion. The influence of IR of the femoral component on patellofemoral kinematics remains controversial. As demonstrated, IR does not imperatively lead to patella maltracking and/or patellofemoral symptoms. Functional outcome in this series shows that relative rotation of the femoral component in accordance with natural variations as seen in the pre-operative assessment allows for good and excellent results


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_4 | Pages 1 - 1
1 Mar 2020
Keenan O Holland G Maempel J Keating J Scott C
Full Access

Though knee osteoarthritis (OA) is diagnosed and monitored radiographically, full thickness cartilage loss (FTCL) has rarely been correlated with radiographic classification. This study aims to analyse which classification system correlates best with FTCL and assessing their reliability. Prospective study of 300 consecutive patients undergoing total knee arthroplasty (TKA) for OA. Two blinded examiners independently graded preoperative radiographs using 5 systems: Kellgren-Lawrence (KL); International Knee Documentation Committee (IKDC); Fairbank; Brandt; and Ahlback. Interobserver agreement was assessed using the intraclass correlation coefficient. Intraoperatively, anterior cruciate ligament (ACL) status and FTCL in 16 regions of interest were recorded. Radiographic classification and FTCL were correlated using the Spearman correlation coefficient. On average, each knee had 6.8±3.1 regions of FTCL, most common medially. The commonest patterns of FTCL were medial with patellofemoral (48%) and tricompartmental (30%). ACL status was associated with pattern of FTCL (p=0.02). All classification systems demonstrated moderate ICC, but this was highest for IKDC: whole knee 0.68 (95%CI 0.60–0.74); medial compartment 0.84 (0.80–0.87); and lateral compartment 0.79 (0.73–0.83). Correlation with FTCL was strongest for Ahlback (Spearman rho 0.27–0.39) and KL (0.30–0.33), though all systems demonstrated medium correlation. The Ahlback was the most discriminating in severe OA. Osteophyte presence in the medial compartment had high positive predictive value for FTCL, but not in the lateral compartment. The Ahlback and KL systems had the highest correlation with confirmed cartilage loss. However, the IKDC system displayed best interobserver reliability, with favourable correlation with FTCL in medial and lateral compartments, though less discriminating in severe disease


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_7 | Pages 6 - 6
1 May 2019
Scott C Clement N Yapp L MacDonald D Patton J Burnett R
Full Access

Anterior knee pain (AKP) is the commonest complication of total knee arthroplasty (TKA). This study aims to assess whether sagittal femoral component position is an independent predictor of AKP after cruciate retaining single radius TKA without primary patellofemoral resurfacing. From a prospective cohort of 297 consecutive TKAs, 73 (25%) patients reported AKP and 89 (30%) reported no pain at 10 years. Patients were assessed pre-operatively and at 1, 5 and 10 years using the short form 12 and Oxford Knee Score (OKS). Variables assessed included demographic data, indication, reoperation, patella resurfacing, and radiographic criteria. Patients with AKP (mean age 67.0 (38–82), 48 (66%) female) had mean Visual Analogue Scale (VAS) Pain scores of 34.3 (range 5–100). VAS scores were 0 in patients with no pain (mean age 66.5 (41–82), 60 (67%) female). Femoral component flexion (FCF), anterior femoral offset ratio, and medial proximal tibial angle all differed significantly between patients with AKP and no pain (p<0.001), p=0.007, p=0.009, respectively). All PROMs were worse in the AKP group at 10 years (p<0.05). OKSs were worse from 1 year (p<0.05). Multivariate analysis confirmed FCF and Insall ratio <0.8 as independent predictors of AKP (R. 2. = 0.263). Extension of ≥0.5° predicted AKP with 87% sensitivity. AKP affects 25% of patients following single radius cruciate retaining TKA, resulting in inferior patient-reported outcome measures at 10 years. Sagittal plane positioning and alignment of the femoral component are important determinants of long-term AKP with femoral component extension being a major risk factor


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 894 - 901
1 Jul 2022
Aebischer AS Hau R de Steiger RN Holder C Wall CJ

Aims

The aim of this study was to investigate the rate of revision for distal femoral arthroplasty (DFA) performed as a primary procedure for native knee fractures using data from the Australian Orthopaedic Association National Joint Arthroplasty Registry (AOANJRR).

Methods

Data from the AOANJRR were obtained for DFA performed as primary procedures for native knee fractures from 1 September 1999 to 31 December 2020. Pathological fractures and revision for failed internal fixation were excluded. The five prostheses identified were the Global Modular Arthroplasty System, the Modular Arthroplasty System, the Modular Universal Tumour And Revision System, the Orthopaedic Salvage System, and the Segmental System. Patient demographic data (age, sex, and American Society of Anesthesiologists grade) were obtained, where available. Kaplan-Meier estimates of survival were used to determine the rate of revision, and the reasons for revision and mortality data were examined.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 549 - 549
1 Sep 2012
Pengas I Pillai A Gayed W Assiotis A Mcnicholas M
Full Access

The patella is a complex sesamoid bone within the quadriceps enhancing mechanical advantage of the extensor mechanism. Depending on activity, the patella magnifies either force or displacement; behaving as a lever, by redirecting quadriceps force it also acts as a pulley. Aim. We describe and validate a device for obtaining consistent dynamic weight bearing views of the patellofemoral joint (PFJ). Materials and Methods. Weight bearing (WB) axial views of 48 knees (24 patients) were performed using the device. The sulcus angle (SA), congruence angle (CA), lateral patellofemoral angle (LPFA), facet angle (FA) and patellofemoral displacement (PD) were measured. These were compared with similar measurements made on prone (PR) and axial (AX) radiographs of same knees. Results. Variance (V=SD2) and Standard error of mean (SEM/95% CI) for all measurements in each of the three views were analysed. For the Sulcus Angle, Congruence angle and LPFA, the WB view had the lowest SEM and the least variance in comparison to PR and AX views (SEM 1.05/V 30.14, SEM 2.52/V 172.39 and SEM 1.34/V 47.61 respectively for the SA, SEM 3.09/V 256, SEM 2.79/V 210.25 and SEM 3.37/V 306.25 respectively for the CA, SEM 0.67/V 11.9, SEM 1.20/V39.06 and SEM 1.03/V 28.83 respectively for the LPFA). SEM and Variance for FA measurements were similar for WB and AX views but superior to PR views (SEM 1.62/V 70.56, SEM 1.6/V 68.9 and SEM 2.3/V 148.84 respectively). Mean PFD was maximum on the WB view compared to the PR and AX views (36.0, −45.62 and 22.23 respectively) with lowest SEM and V (SEM 8.73/V 2052.0, SEM 18.65/V 92959.67 and SEM 9.70/V 2540.16 respectively). Conclusion. The WB view as introduced and reported here has consistently lower Variance, SEM and SD in comparison to Axial and Prone views for all measurements of the PFJ. WB view also gives a more accurate dynamic measure of Patello Femoral displacement. The view is easily obtained and readily reproduced


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 525 - 525
1 Sep 2012
Kumar V Garg B Malhotra R
Full Access

Introduction. We compared standard NexGen Cruciate substituting-flex prosthesis with gender-specific NexGen Cruciate substituting flex prosthesis in patients undergoing bilateral total knee arthroplasty with regard to Coverage of the bone by femoral component, Clinical outcome, Radiographic outcome, Survival and complication rates, with special emphasis on patellofemoral complications. Material & Methods. 30 female patients with osteo-arthritis of the knees with similar deformity and preoperative range of motion were randomized to have one knee replaced with a gender non-specific Nexgen Cruciate substituting (Zimmer) prosthesis and the other with Gender Cruciate substituting (Zimmer) prosthesis. Follow-up clinical evaluation was done at 6, and 12 months postoperatively and then at yearly interval using “Knee Society” Recommendations. Clinical assessment of the patellofemoral joint of the replaced knees was done with the help of “Hospital for Special Surgery” patellar scoring system. The overall patient satisfaction after surgery was evaluated with use of the British Orthopaedic Association patient satisfaction score. Results. The mean age was 63.8 years (range 49–76 years). 14 patients had standard NexGen Cruciate substituting-flex gender knee prosthesis on right side and 16 patients had on left side. On the other sides, standard NexGen Cruciate substituting-flex prosthesis implant was used. Preop Clinical findings were similar in both groups. The average Preop range of motion was identical in both the groups. The average follow up was 2.5 years (2–3.8 years). The mean post-operative Knee Society knee scores were 88,90,94, (70 to 100) and 87,92, 93 (70 to 100) points and the function scores were 83,85,88 (60 to 100) and 84.86.88 (60 to 100) points for the standard implants and the gender-specific designs, respectively at 6 months, 1 year and 2 year follow up. Mean improvement in patella score was 65, 71.1 and 73.3 points in Gender group at the end of 6 month, 1 yr and 2 yr respectively as compared to 65.6, 71.1 and 72.2 in Nexgen group. No patient had malpositioning of components or radiolucencies at the end of 2 year follow up. Mean improvement in BOA functional score was 20.6, 22.6 and 24.1 points in Gender group at the end of 6 months, 1 year and 2 year respectively as compared to 20.7, 21.8 and 23.2 in Nexgen group. In those with a standard prosthesis, the femoral component was closely matched in 30 knees, overhung in 17 and undercovered the bone in 13. In those with a gender-specific prosthesis, it was closely matched in 45 knees and undercovered the bone in 15. Conclusion. Although gender specific knee matched the femoral anatomy of Indian female knees better than the standard nexgen Knee, we found no significant differences between the two groups with regard to the clinical and radiological results, patient satisfaction or complication rate


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 534 - 534
1 Sep 2012
Heinert G Preiss S Klauser W Kendoff D Sussmann P
Full Access

Introduction. Patellar tracking in total knee replacements has been extensively studied, but little is known about patellar tracking in isolated patellofemoral replacements. We compared patellar tracking and the position of the patellar groove in the natural knee, followed by implantation of the femoral component of a PFR (patella unresurfaced) and after implantation of the femoral & patellar component of the PFR. Methods. Computer navigation was used to track the patella in eight whole lower extremities of four cadavers in the natural knee, in the same knee with the femoral component of the PFR (PFR-P) and with the femoral and patellar component of the PFR (PFR+P, patella resurfaced) (Depuy Sigma PFR). The form and position of the trochlea in the natural knee and the patellar groove of the femoral component was also analysed. Values are means+/−SD, two tailed Student's t-test for paired samples. Results. With a PFR-P the patella had a slightly more lateral tilt (0.8+/−0.8° to 2.8+/−2.5° at 40–100° of flexion, p<0.05 vs. Nat), this was more pronounced with the PFR+P (2.0+/−0.7° to 4.9+/−1.8° at 20–90° flexion, p<0.05 vs. Nat., p<0.05 vs. PFR-P at 20–80° flexion). No differences in patella rotation were seen between the three groups. In the PFR-P group the patella tracked a little more medially compared to the natural knee (0.6+/− 0.7mm to 1.3+/−2.6mm, p<0.05 at 20°,80°,90° flexion). The difference was more pronounced after patella resurfacing (PFR+P) (2.1+/−2.0mm to 3.0+/−2.2mm, p<0.05 vs. Nat. at 10°–100°, p<0.05 vs. PFR-P from 10–100°). When analysed relative to the patellar groove of the trochlea/femoral component the patella in the natural knee tracked slightly lateral to the groove (2.0+/−1.7mm to 2.9+/−2.0mm at 50–100° p<0.05), so did the patella of PFR-P (2.0+/−2.3mm to 2.3+/−2.3mm at 60–90° flexion, p<0.05), whilst the PFR+P tracked right on the groove (0.6+/−3.7mm medially to 0.6+/−2.9mm laterally, p<0.05 vs Nat at 10–30° & 70–100°, p<0.05 vs. PFR-P at 10–100°). Distance from the patellatot the epicondylar axis was slightly larger in the PFR-P group (0.6+/− 0.7mm to 1.3+/−1.4mm, p<0.05 vs. Natu at 20,80 & 90°. This was more pronounced with patellar resurfacing (2.1+/−2.0 to 3.0+/−2.2mm, p<0.05 vs. Nat at 10–100°, p<0.05 vs. PFR-P at 20–100°) The patella groove on the natural knee and the implanted femoral component of the implanted PFR had the same radius, inclination relative to the femoral mechanical axis, antero-posterior position and medio-lateral orientation. As intended by the designers the groove of the patellar component extended about 13mm further superiorly and 0.5mm more inferiorly. Discussion. The patella groove on the femoral component of the PFR reproduces the natural trochlear anatomy well. Patella tracking in the PFR-P shows only minor differences compared to the natural knee. Resurfacing of the patella in the PFR+P group causes the patella to tilt a little more laterally and track a little more medially, the distance to the epicondylar axis is slightly larger but this allows the patella to engage better in the patellar groove of the femoral component


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1138 - 1143
1 Sep 2019
MacDonald DRW Caba-Doussoux P Carnegie CA Escriba I Forward DP Graf M Johnstone AJ

Aims

The aim of this study was to compare the incidence of anterior knee pain after antegrade tibial nailing using suprapatellar and infrapatellar surgical approaches

Patients and Methods

A total of 95 patients with a tibial fracture requiring an intramedullary nail were randomized to treatment using a supra- or infrapatellar approach. Anterior knee pain was assessed at four and six months, and one year postoperatively, using the Aberdeen Weightbearing Test – Knee (AWT-K) score and a visual analogue scale (VAS) score for pain. The AWT-K is an objective patient-reported outcome measure that uses weight transmitted through the knee when kneeling as a surrogate for anterior knee pain.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 349 - 353
1 Mar 2007
Goh S Yang KY Koh JSB Wong MK Chua SY Chua DTC Howe TS

We carried out a retrospective review over ten months of patients who had presented with a low-energy subtrochanteric fracture. We identified 13 women of whom nine were on long-term alendronate therapy and four were not. The patients treated with alendronate were younger, with a mean age of 66.9 years (55 to 82) vs 80.3 years (64 to 92) and were more socially active. The fractures sustained by the patients in the alendronate group were mainly at the femoral metaphyseal-diaphyseal junction and many had occurred after minimal trauma. Five of these patients had prodromal pain in the affected hip in the months preceding the fall, and three demonstrated a stress reaction in the cortex in the contralateral femur.

Our study suggests that prolonged suppression of bone remodelling with alendronate may be associated with a new form of insufficiency fracture of the femur. We believe that this finding is important and indicates the need for caution in the long-term use of alendronate in the treatment of osteoporosis.